TURBO ENERGY Lithium Series 48V 5.1kWh Slim with Victron Inverter Installation Guide

June 10, 2024
TURBO ENERGY

TURBO ENERGY logo QUICK INSTALLATION GUIDE
Lithium Series 48V 5.1kWh Slim
+
VICTRON INVERTERTURBO ENERGY Lithium Series 48V 5.1kWh Slim with
Victron Inverter

INVERTER VICTRON configuration

The configuration between the inverter and the battery is quite simple. In fact, to facilitate the control and operation of the installation, a GX device is used: COLOR CONTROL GX, VENUS GX, CERBO GX. The connection of the communication is made between the master battery and the Color Control, and from the Color Control to the inverter.TURBO ENERGY Lithium Series 48V
5.1kWh Slim with Victron Inverter - Color Control 2We can use the REGULADOR MPPT BlueSolar / SmartSolar (VE. Direct) Underneath, a complete scheme of connection of all devices is shown.
TURBO ENERGY Lithium Series 48V 5.1kWh Slim with Victron Inverter - complete
scheme

Configuration Lithium Series 48V 5.1 kWh Slim

Each module has 4 DIP (Dual Inline Package) switches that will be configured differently depending on the number of batteries to be connected They are configured according to the binary code, starting with the master.

Address Dial switch position Explain
#1 #2 #3
1 ON OFF
2 OFF ON
3 ON ON
4 OFF OFF
5 ON OFF
6 OFF ON
7 ON ON
8 OFF OFF
9 ON OFF
10 OFF ON
11 ON ON
12 OFF OFF
13 ON OFF
14 OFF ON
15 ON ON

Wired configuration

TURBO ENERGY Lithium Series 48V 5.1kWh Slim with Victron Inverter - Wired
configurationThe cable needed to make the connection is the RJ45. It is a special cable that is composed of 8 smaller cables each with a different color configuration. The battery includes inside the connection cable with the inverter. The cable is included inside the battery box.TURBO ENERGY Lithium
Series 48V 5.1kWh Slim with Victron Inverter - battery
box

Procedure

We need to check the firmware of the equipment that we are going to use.

  • The minimum device version GX is v2.42
  • The minimum version of the inverters MULTIPLUS / MULTIGRID / QUATTRO is 422.
  • The minimum version of the VE. Direct MPPT is 1.29

We connect the CAN wire of communication from the port CAN IN to COLOR CONTROL GX to its input VE CAN, besides adding the TERMINADOR RJ4 in the other VE CAN port.

GX Device Setting

  1. GENERAL → Services → CAN-BUS Profile → CAN-BUS BMS (500Kbit/s)
  2. SYSTEM SETTING → TURBO ENERGY battery on CAN-BUSTURBO ENERGY Lithium Series 48V 5.1kWh Slim with Victron Inverter - Device Setting 2
  3. CONFIGURACIÓN DEL SISTEMA → Service →DVCC ON
  4. CONNECTION VERIFICATION → We can check that connection between Battery and Venus has been successful when the option Turboe appears in the general menu.

VE CONFIGURE 3 Settings

Select the capacity in function of the number of batteries. 50Ah * Nº of batteries ![TURBO ENERGY Lithium Series 48V 5.1kWh Slim with Victron Inverter

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

TURBO ENERGY User Manuals

Related Manuals