TURBO ENERGY Lithium Series Victron Energy Inverter Installation Guide

June 9, 2024
TURBO ENERGY

TURBO ENERGY Lithium Series Victron Energy Inverter

TURBO-ENERGY-Lithium-Series-Victron-Energy-Inverter-
fig-1

Inverter configuration

The configuration between the inverter and the battery is quite simple. In fact, to facilitate the control and operation of the installation, a GX device is used: COLOR CONTROL GX, VENUS GX, CERBO GX.

The connection of the communication is made between the master battery and the Color Control, and from the Color Control to the inverter.TURBO-ENERGY-
Lithium-Series-Victron-Energy-Inverter-fig-3

We can use the REGULADOR MPPT BlueSolar / SmartSolar (VE. Direct)

Underneath, a complete scheme of connection of all devices is shown.TURBO-
ENERGY-Lithium-Series-Victron-Energy-Inverter-fig-5

Battery On and Off

To turn on the battery, press the power button for a few seconds. The BMS will start working and the LED will light up. To turn off the batteries, press the power button for more than 5 seconds.

Setting Lithium Series Dual 48V 5.1 kWh

Each module has 5 DIP switches (SW1, SW2, SW3, SW4, and SW5) that will be set differently based on system requirements, battery connection, and inverter .TURBO-ENERGY-Lithium-Series-Victron-Energy-Inverter-
fig-6

SW1 is for the communication protocol with the inverter. If the CAN protocol is used, 1 and 2 must be ON. SW4 and SW5 are for communication with the inverter and depend on the communication cable and protocol of the inverter. If a pin-to-pin cable is used, the DIP settings are as follows:TURBO-ENERGY-
Lithium-Series-Victron-Energy-Inverter-fig-7

DIPS FOR CONNECTION ON PARALLEL
SW2 and SW3 are for communication between batteries.TURBO-ENERGY-Lithium-
Series-Victron-Energy-Inverter-fig-8TURBO-ENERGY-Lithium-Series-Victron-Energy-Inverter-
fig-8 TURBO-ENERGY-Lithium-Series-
Victron-Energy-Inverter-fig-9 TURBO-
ENERGY-Lithium-Series-Victron-Energy-Inverter-fig-11 TURBO-ENERGY-Lithium-Series-Victron-Energy-Inverter-
fig-12

Make sure DIP switch SW2 is selected correctly. If the battery is connected in parallel mode, but DIP8 is in the ON position, a serious and dangerous fault may occur. On the other hand, if the battery is connected in serial mode, but SW2 DIP8 is in the OFF position, a serious and dangerous fault may occur.

Wired configuration

TURBO-ENERGY-Lithium-Series-Victron-Energy-Inverter-
fig-13

  • The cable needed to make the connection is the RJ45. This is a cable made up of 8 smaller cables each with a different color configuration. A standard pin-to-pin cable with an RJ45 connector should be used.
  • For the connection between the inverter and the battery, the RJ45 cable will be connected to the “Inverter” port of the battery, and to the CAN port of the inverter

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

TURBO ENERGY User Manuals

Related Manuals