TURBO ENERGY Lithium Series Victron Energy Inverter Installation Guide

June 9, 2024
TURBO ENERGY

TURBO ENERGY Lithium Series Victron Energy Inverter

TURBO-ENERGY-Lithium-Series-Victron-Energy-Inverter-
fig-1

Inverter configuration

The configuration between the inverter and the battery is quite simple. In fact, to facilitate the control and operation of the installation, a GX device is used: COLOR CONTROL GX, VENUS GX, CERBO GX.

The connection of the communication is made between the master battery and the Color Control, and from the Color Control to the inverter.TURBO-ENERGY-
Lithium-Series-Victron-Energy-Inverter-fig-3

We can use the REGULADOR MPPT BlueSolar / SmartSolar (VE. Direct)

Underneath, a complete scheme of connection of all devices is shown.TURBO-
ENERGY-Lithium-Series-Victron-Energy-Inverter-fig-5

Battery On and Off

To turn on the battery, press the power button for a few seconds. The BMS will start working and the LED will light up. To turn off the batteries, press the power button for more than 5 seconds.

Setting Lithium Series Dual 48V 5.1 kWh

Each module has 5 DIP switches (SW1, SW2, SW3, SW4, and SW5) that will be set differently based on system requirements, battery connection, and inverter .TURBO-ENERGY-Lithium-Series-Victron-Energy-Inverter-
fig-6

SW1 is for the communication protocol with the inverter. If the CAN protocol is used, 1 and 2 must be ON. SW4 and SW5 are for communication with the inverter and depend on the communication cable and protocol of the inverter. If a pin-to-pin cable is used, the DIP settings are as follows:TURBO-ENERGY-
Lithium-Series-Victron-Energy-Inverter-fig-7

DIPS FOR CONNECTION ON PARALLEL
SW2 and SW3 are for communication between batteries.TURBO-ENERGY-Lithium-
Series-Victron-Energy-Inverter-fig-8TURBO-ENERGY-Lithium-Series-Victron-Energy-Inverter-
fig-8 TURBO-ENERGY-Lithium-Series-
Victron-Energy-Inverter-fig-9 TURBO-
ENERGY-Lithium-Series-Victron-Energy-Inverter-fig-11 TURBO-ENERGY-Lithium-Series-Victron-Energy-Inverter-
fig-12

Make sure DIP switch SW2 is selected correctly. If the battery is connected in parallel mode, but DIP8 is in the ON position, a serious and dangerous fault may occur. On the other hand, if the battery is connected in serial mode, but SW2 DIP8 is in the OFF position, a serious and dangerous fault may occur.

Wired configuration

TURBO-ENERGY-Lithium-Series-Victron-Energy-Inverter-
fig-13

  • The cable needed to make the connection is the RJ45. This is a cable made up of 8 smaller cables each with a different color configuration. A standard pin-to-pin cable with an RJ45 connector should be used.
  • For the connection between the inverter and the battery, the RJ45 cable will be connected to the “Inverter” port of the battery, and to the CAN port of the inverter