AXIS D8208-R Industrial PoE++ Switch User Manual
- June 11, 2024
- AXIS
Table of Contents
AXIS D8208-R Industrial PoE++ Switch
About this document
Note The product is intended for use by network administrators who are responsible for operating and maintaining network equipment. Basic working knowledge of general switch functions, security, the Internet Protocol (IP), and Simple Network Management Protocol (SNMP) is assumed.
This user manual will give you information on how you:
- access the product
- access connected IP devices in the product’s topology view
- configure selected setup examples
- perform maintenance on the product
Product features and their settings are covered in more detail in the product’s context-sensitive built-in help. For more information, see Get to know your product’s built-in help on page 5 .
Solution overview
Get started
Access the product from a browser
Note Install, connect and power up the product as specified in its
Installation Guide.
- Use AXIS IP Utility or AXIS Device Manager to find the product on the network. For information on how to discover and assign an IP address, go to axis.com/support
- Enter the username and password provided on the product label.
- Follow the steps in the setup wizard to:
- Change the password (recommended for security reasons)
- Set the IP address via DHCP or manually
- Configure the DHCP server
- Set the date & time information
- Set the system information
- Click Apply.
- Relogin using the new password.
You will now enter the product’s web page, and will be able to configure and manage the product.
Get to know your product’s web page
- Basic features
- Advanced features
- Toggle button – switch between windowed and full screens
- RJ45 port (PoE+) status indicators
- RJ45 port (non-PoE) status indicators
- SFP port status indicators
- Content area for basic/advanced features
- Save button – save the start-up configuration
- Help button – access the context-sensitive built-in help
- Log out button
- Menu path
Get to know your product’s built-in help
Your product has a context-sensitive built-in help. The help provides more
detailed information on the product’s basic and advanced features and their
settings. To access the help content for any given view, click . Some help
content also includes clickable terms and acronyms that are explained in more
detail in the built-in glossary.
Access devices in your product’s network
Topology view
The topology view allows you to remotely access, manage and monitor all
discovered IP devices in your product’s network, for example via a tablet or a
smart phone. To display the discovered IP devices in a graphical network, go
to Basic > Topology View.
- Arrow button to move the view in four directions
- Zoom in and zoom out buttons
- Drop-down button to access and change device information to be displayed in the view
- Content area for devices discovered in the network
- Settings button to access and change device, group and configuration information
When you click a device icon in the topology view, a device console is opened to allow you access to:
- dashboard console with device information and available device-specific actions, such as login, diagnostics, find switch, PoE configuration and reboot
- notification console with information on alarms and logs triggered by events
- monitor console with information on device traffic
Setup examples
Set up access VLANs
VLANS are typically used on large networks to create multiple broadcast
domains, but they can also be used to segregate network traffic. For example,
video traffic can be part of one VLAN, and other network traffic can be part
of another.
- Go to Advanced > VLANs > Configuration.
- Under Global VLAN Configuration, enter the VLANs you want to create to the Allowed Access VLANs field. For example, if you enter, 1, 10-13, 200, 300, the following VLAN IDs will be created: 1, 10, 11, 12, 13, 200 and 300.
- To assign a created VLAN ID to a given port under Port VLAN Configuration, enter the ID to the Port VLAN field.
- Click Apply.
Reserve an IP address based on MAC address
- Go to Advanced > DHCP Server > Configuration > Pool.
- Click Add New Pool.
- Enter a name for the pool, for example 00:01:02:03:04:05, and click Apply. No spaces are allowed in the name.
- To access the pool settings, click the added name.
- In the Type drop-down menu, select Host.
- Enter other required settings, such as IP address, Subnet Mask and Default Router.
- In the Client Identifier drop-down menu, select MAC.
- In the Hardware Address field, enter F8-16-54-B2-35-63.
- Click Apply.
To save the start-up configuration, click on the product’s web page. See Get to know your product’s web page on page 4 .
Set a PoE schedule
If you have a certain time frame where you want the switch to provide PoE, for example, to your cameras, it can be useful to create a PoE schedule and assign it to one or more PoE ports. You can create up to 16 PoE schedule profiles.
To create a PoE schedule:
-
Go to Advanced > PoE > Configuration > Schedule Profile.
-
In the Profile drop-down menu, select a number for the profile.
-
Change the default profile name as needed.
-
To specify when you want PoE to switch on, select hours (HH) and minutes (MM) in the Start Time drop-down menu.
-
To specify when you want PoE to switch off, select hours (HH) and minutes (MM) in the End Time drop-down menu.
- If you want to use the same schedule for all days of the week, select the start and end times on the Week Day row marked with an asterisk (*).
- If you want to use the same schedule for certain days of the week only, select the start and end times for selected days on the respective Week Day rows.
-
Click Apply.
To assign the created PoE schedule to one or more PoE ports: -
Go to Basic > Basic Settings > PoE > Power Management.
-
Under PoE Port Configuration in the PoE Schedule drop-down menu, select the number of the specified PoE schedule profile.
– If you want to assign the same profile for all ports, select the profile number on the Port row marked with an asterisk (*).
– If you want to assign the same profile for certain ports only, select the profile numbers for selected ports on the respective Port number rows. -
Click Apply.
Check connection status via PoE auto checking
You can use PoE auto checking if you want to periodically check the connection
status between your switch and the PoE enabled network device connected to it.
If, during auto checking, the network device does not respond to the switch,
the switch will automatically restart the PoE port the network device is
connected to.
To enable auto checking via the topology view:
- Go to Basic > Topology View.
- To open the Dashboard console of your switch, click the switch icon.
- Click PoE Config.
- In the PoE Auto Checking drop-down menu, select Enable.
To configure the auto checking parameters:
- Go to Advanced > PoE > Configuration > Auto Checking.
- In the Ping IP Address field, enter the IP address of the device that is connected to the port you want to assign auto checking for.
- Enter the other needed parameters, for example:
- Port: 1
- Ping IP Address: 192.168.0.90
- Startup Time: 60
- Interval Time (sec): 30
- Retry Time: 3
- Failure Action: Reboot Remote PD
- Reboot time (sec): 15
- Click Apply.
How to connect a mode B camera
For the following camera models, you need to change the PoE settings:
- AXIS Q6010-E Network Camera
- AXIS Q6000-E PTZ Dome Network Camera
- AXIS Q6100-E Network Camera
1. Go to Basic > Basic Settings > PoE > Power Management.
2. For the port that your camera is connected to, set PoE Mode to force90w.
3. For the port that your camera is connected to, set LLDP to Disabled.
How to use the console port
The switch has a serial console port that allows you to manage the switch
through the command-line interface.
- Connect the supplied console cable to the console connector on the switch.
- Connect the console cable to the COM-port on your computer.
- On your computer, open a teminal emulator to manage the switch.
Use these COM port settings:
- Baud rate: 115200
- Stop bits: 1
- Data bits: 8
- Parity: N
- Flow control: None
Create Rapid Ring links for network redundancy
If network redundancy is required, you can create redundant links between
switches using Rapid Ring.
In this example, there are 3 switches connected by a redundant link and no
extra VLANS. If any of the uplinks between the switches should fail, the
redundant link is activated and provides network connectivity.
Device Name | Model Name |
---|---|
Switch – 01 | AXIS D8208-R |
Switch – 02 | AXIS D8208-R |
Switch – 03 | AXIS D8208-R |
For the switch you want to use as master:
1. Go to Advanced > Rapid Ring.
2. Under Role, select Master.
3. Click Apply.
For all the other switches:
1. Go to Advanced > Rapid Ring.
2. Under Role, select Member.
3. Click Apply.
To save the start-up configuration, click
Switch ports on/off using VAPIX
Use the following command in VAPIX:
-
To switch the port on:
http://[IP address of the switch]/axis- cgi/nvr/poe/setportmode.cgi?port=[number of the port on the switch]enabled=yes&schemaversion=1 -
To switch the port off:
http://[IP address of the switch]/axis- cgi/nvr/poe/setportmode.cgi?port=[number
of the port on the switch]enabled=no&schemaversion=1
Connect a 1Gbps SFP module
- Go to Advanced > Port Management > Port Configuration.
- For the port that you connected the module to (9 or 10), set Configured to 1 Gbps FDX.
Note If you set the port to Auto, both SFP and SFP+ will work.
Maintenance
Restart the product
Note Any configuration files or scripts you have saved in the product are available after restart.
- Go to Advanced > Maintenance > Restart Device.
- If you want to simulate a power-on (cold restart), select Force Cool Restart. This will impact the traffic routed through the product.
- Click Yes.
After restart, the product will boot normally.
Set a reboot schedule
Note Any configuration files or scripts you have saved in the product are
available after reboot.
- Go to Advanced > Maintenance > Reboot Schedule.
- Set Mode to Enabled.
- Select the weekday and time for reboot.
- Click Apply.
Restore the product to factory default values
Important Any configuration files or scripts you have saved in the product are
restored to factory default values.
1. Go to Advanced > Maintenance > Factory Defaults.
2. If you want to keep the current IP settings, select Keep IP setup.
3. Click Yes.
Note For more information on how to restore the product to factory default values using the mode/reset button, see Buttons.
Upgrade the product firmware
Important The firmware upgrade takes up to 10 minutes. Do not restart or power
off the device during this time.
- Go to Advanced > Maintenance > Firmware > Firmware Upgrade.
- To select the firmware file from a specified location, click Browse.
- If you want to simulate a power-on (cold restart) after firmware upgrade, select Force Cool Restart. This will impact the traffic routed through the product.
- Click Upload.
After firmware upgrade, the product will restart normally.
Revert to alternate firmware image
You can choose to use the alternate (backup) firmware image instead of the
active (primary) firmware image in the product.
Information tables on both images are shown under Advanced > Maintenance >
Firmware > Firmware Selection.
Note
- If the active image is already set as the alternate image, only the Active Image table is shown, and the Activate Alternate Image button is disabled.
- If the alternate image is already set as the active image (either manually or due to corrupted primary image), and a new firmware image is uploaded to the product, the new image will automatically be set as the active image.
- Firmware version and date information may be empty for older firmware releases. This is normal.
To set the alternate image as the active image:
- Go to Advanced > Maintenance > Firmware > Firmware Selection.
- Click Activate Alternate Image.
Product overview
- RJ45 ports (PoE++) 10M/100M/1G x4
- LEDs (front panel)
- Power connectors x2
- RJ45 ports (PoE++) 10M/100M/1G x2
- RJ45 ports (PoE++) 100M/1G/2.5G x2
- Console connector
- DIP switch
- Control button
- Grounding screw
- SFP+ ports x2
- Product label
Buttons
Reset button
To reset the switch to factory default:
1. Start the switch.
2. Press and hold the reset button.
3. When the LEDs light up, release the button.
LED indicators
Power LED
LED | Color | Indication |
---|---|---|
Power1 | Green (lit) | The switch is powered ON. |
N/A | The switch is not receiving power from power1. | |
Power2 | Green (lit) | The switch is powered ON. |
N/A | The switch is not receiving power from power2. |
System LED
LED | Color | Indication |
---|---|---|
System | Green (lit) | The switch is ready. |
N/A | The switch is not ready. |
Alarm LED
LED | Color | Indication |
---|---|---|
Alarm | Red (lit) | The switch has detected an abnormal state, for example |
temperature or voltage out of range.
N/A| The system is normal.
Ring master LED
LED | Color | Indication |
---|---|---|
RM | Green (lit) | Ring Master has been detected in the switch. |
Amber (lit) | Ring Member has been detected in the switch. | |
N/A | Ring master disabled. |
Rapid chain LED
LED | Color | Indication |
---|---|---|
RC | Green (lit) | Rapid Chain has been detected in the switch (active path). |
Amber (lit) | Rapid Chain has been detected in the switch (backup path). | |
Amber (blink) | Error: There is no corresponding rapid chain switch found. | |
N/A | Rapid chain disabled. |
Port status LEDs
LED | Color | Indication |
---|---|---|
RJ45 ports (1–6) | Green (lit) | The port is enabled and established a link to |
connected device, and the connection speed is 1000Mbps.
Green (blink)| The port is transmitting/receiving packets, and the connection
speed is 1000Mbps.
Amber (lit)| The port is enabled and established a link to connected device,
and the connection speed is 10/100Mbps.
Amber (blink)| The port is transmitting/receiving packets, and the connection
speed is 10/100Mbps.
N/A| The port has no active network cable connected, or it is not established
a link to connected device. Otherwise, the port may have been disabled through
the product user interface.
RJ45 ports (7–8)| Green (lit)| The port is enabled and established a link to
connected device, and the connection speed is 2500Mbps.
Green (blink)| The port is transmitting/receiving packets, and the connection
speed is 2500Mbps.
Amber (lit)| The port is enabled and established a link to connected device,
and the connection speed is 100/1000Mbps.
Amber (blink)| The port is transmitting/receiving packets, and the connection
speed is 100/1000Mbps.
N/A| The port has no active network cable connected, or it is not established
a link to connected device. Otherwise, the port may have been disabled through
the product user interface.
PoE ports (1–8)| Green (lit)| PoE is on.
Amber (lit)| PoE is abnormal.
N/A| PoE is off.
SFP+ ports (9–10)| Green (lit)| The port is enabled and established a link to
connected device, and the connection speed is 1000Mbps.
Green (blink)| The port is transmitting/receiving packets, and the connection
speed is 1000Mbps.
Blue(lit)| The port is enabled and established a link to connected device, and
the connection speed is 10Gbps.
Blue (blink)| The port is transmitting/receiving packets, and the connection
speed is 10Gbps.
N/A| The port has no active network cable connected, or it is not established
a link to connected device. Otherwise, the port may have been disabled through
the
product user interface.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>