CO2 pressure regulator for disposable and refillable pressurised gas

cylinders

  • Compatible with disposable pressurised gas cylinders with thread M10x1 (SYSTEM U) and refillable pressurised gas cylinders with thread W21.8 x 1/14“ (SYSTEM M).
  • Fine needle valve for safe and targeted dosing of CO2 in the aquarium.
  • With safety valve.

Safety instructions

  1. Operate only with solenoid valves JBL PROFLORA CO2 VALVE or CO2 sets containing such a valve.
  2. Follow the safety instructions for handling CO2. These can be found on the CO2 pressurised gas cylinders.
  3. Children must be supervised to ensure that they do not play with the appliance and its power supply unit.
  4. Do not use the appliance for any purpose other than that described in these instructions for use.
  5. Do not operate or store the unit in places where there is a risk of frost.
  6. Appliance may only be used indoors.
  7. Appliance may only be used in a dry environment.

    Disposal: Do not dispose of this device and the power unit in the normal household waste. Please follow your local disposal regulations for electrical equipment.

Pressure JBL PROFLORA CO2 REGULATOR BASIC

Parts:
b. Connection adapter (JBL PROFLORA CO2 ADAPT U – M) for refillable CO2 pressurised gas cylinders W21.8 x 1/14 (BASIC version 1).
c. Connection thread for disposable CO2 pressurised gas cylinders: M10 x 1 (SYSTEM U).
d. Connection (screw fitting) for CO2 hose 4 / 6 mm.
e. Needle valve for CO2 quantity.
Description:
With this pressure reducer, JBL has succeeded in creating an inexpensive yet high-quality pressure regulating fitting for refillable as well as for disposable CO2 pressurised gas cylinders. The two pressure gauges have been deliberately omitted in order to keep the cost of the pressure regulator low.
A conversion to disposable or refillable CO₂ pressurised gas cylinders is also possible here by purchasing or removing the JBL PROFLORA CO2
ADAPT U – M thread adapter.
All pressure regulators come equipped with a smooth-running and high precision adjustment screw (needle valve) that allows you to set the CO2  quantity you need conveniently and precisely.

Pressure regulator JBL PROFLORA CO2 REGULATOR AVANCED

Parts :
a. Connection adapter (JBL PROFLORA CO2 ADAPT U – M) for reusable CO2 pressurised gas cylinders W21.8 x 1/14 (ADVANCED version 1).
b. Connection thread for disposable CO2 pressurised gas cylinders: M10 x 1 (SYSTEM U).
c. Pressure gauge (display) for cylinder pressure.
d. Pressure gauge (display) for working pressure.
e. Connection (screw fitting) for CO2 hose 4 / 6 mm.
f. Needle valve for CO2 quantity.
g. Adjustment knob for working pressure.
h. Opening of the pressure relief valve

Description:
State-of-the-art pressure regulator that can be used for both refillable and disposable CO2 pressurised gas cylinders:
The JBL PROFLORA CO2 REGULATOR AVANCED pressure regulator can be converted to disposable CO2 pressurised gas cylinders by simply unscrewing the JBL PROFLORA CO2 ADAPT U – M thread adapter (part a.)
The cylinder connection nut of the pressure regulator is designed as a knurled nut that only needs light tightening by hand, without the use of tools.
The use of tools can lead to damage.
The pressure in the CO2 pressurised gas cylinder and the working pressure can conveniently be read on two separate pressure gauges. The working pressure can be adjusted from 1.2 to 2 bar. A safety valve ensures safety in case of unintentional excess pressure caused by releasing the CO2 into the environment.

Pressure JBL PROFLORA CO2 REGULATOR PROFESSIONAL

Parts:
a. Connection adapter (JBL PROFLORA CO2 ADAPT U – M) for refillable CO2 pressurised gas cylinders W21.8 x 1/14 (ADVANCED version 1).
b. Connection thread for disposable CO2 pressurised gas cylinders: M10 x 1 (SYSTEM U).
c. Pressure gauge (display) for cylinder pressure.
d. Pressure gauge (display) for working pressure.
e. Connection (screw fitting) for CO2 hose 4 / 6 mm.
f. Needle valve for CO2 quantity.
g. Adjustment knob for working pressure.
h. Opening of the pressure relief valve.
i. Valve body.
j. Power supply unit 12 V DC.

Description:
State-of-the-art pressure regulator that can be used for both refillable and disposable CO2 pressurised gas cylinders:
The JBL PROFLORA CO2 REGULATOR PROFESSIONAL pressure regulator can be converted to disposable CO2 pressurised gas cylinders by simply
unscrewing the JBL PROFLORA CO2 ADAPT U – M thread adapter (part a.)
The cylinder connection nut of the pressure regulator is designed as a knurled nut that only needs light tightening by hand, without the use of tools.
The use of tools can lead to damage.

The pressure in the CO2 pressurised gas cylinder and the working pressure can conveniently be read on two separate pressure gauges. The workingpressure can be adjusted from 1.2 to 2 bar. A safety valve ensures safety in case of unintentional excess pressure caused by releasing the CO2 intothe environment.
Pre-assembled and silent 12 V solenoid valve (part i.) of the highest quality. Power consumption of only 0.8 W, optimised for use with CO2 fertilisersystems, saves electricity. An electronic 12 V power supply unit enables use on all common mains voltages worldwide.

Installation

SYSTEM U:
Remove the connection adapter (JBL PROFLORA CO2 ADAPT U – M) using a 6 mm Allen key. Now quickly screw the rear internal thread of the pressure regulator fitting onto the external thread of the JBL PROFLORA CO2 CYLINDER 500 U or JBL PROFLORA CO2 CYLINDER 1200 U disposable CO2 pressurised gas cylinder. After a few turns a brief hissing noise will beheard. Continue to turn briskly until resistance is felt. Then turn about half a turn more until the pressure regulator is hand-tight.

SYSTEM M:
Screw the rear connection nut (JBL PROFLORA CO2 ADAPT U – M) of the pressure regulator onto the external thread of the cylinder valve on the
JBL PROFLORA CO2 CYLINDER 500 M or JBL PROFLORA CO2 CYLINDER 2000 M refillable CO2 pressurised gas cylinder. The connecting nut is a knurled nut intended for use WITHOUT tools! Only tighten it „hand-tight“ without tools. Use of tools can lead to damage. Close the needle valve clockwise if not already closed.
Never operate a vertical or inverted CO2 pressurised gas cylinders!!! This can destroy the pressure regulator!
JBL PROFLORA CO2 REGULATOR PROFESSIONAL: The left pressure gauge now shows the cylinder pressure of about 60 bar and the right pressure gauge the working pressure of about 1.5 bar

Note on the pressure displayed on the pressure regulator

In the CO2 pressurised gas cylinders, the CO2 gas is under high pressure. This pressure depends on the ambient temperature. At room temperature (approx. 20 °C), the left pressure gauge of the pressure regulator shows a pressure of about 50 bar. This increases as the room temperature rises.
Thus at 30 °C, the pressure gauge shows about 70 bar. The pressure in the CO2 pressurised gas cylinder is not a measure of how full the cylinder is.
It will remain constant at the temperature-related value until shortly before the cylinder is empty. How much CO2 is in a CO2 pressurised gas cylinder can only be determined by weighing it. The empty weight (tare) is stamped on  the cylinder. The current weight minus the tare gives the available amount of CO2.
The pressure in the CO2 pressurised gas cylinder is regulated down to an easy to-handle so-called „working pressure“ by the pressure regulator. The right- hand pressure gauge of the pressure regulator shows this working pressure. It is preset to approx. 1.5 bar in the J BL PROFLORA CO2 REGULATOR BASIC pressure regulators. This pressure is ideal for CO2 fertilisation of aquariums. When changing the working pressure, JBL PROFLORA CO2 REGULATOR PROFESSIONAL, it is important that a decrease in CO2 takes place, i.e. the adjustment screw must not be closed, otherwise the new working pressure cannot regulate itself.

Changing cylinders

If the cylinder pressure on the left-hand pressure gauge falls below 30 bar, the refillable CO2 pressurised gas cylinder needs to be refilled within the next 2 – 3 days. The disposable CO2 pressurised gas cylinder may only be changed when it no longer contains CO2. This is when both pressure gauges show 0 bar or no more CO2 bubbles rise in the aquarium.
Disposable CO2 pressurised gas cylinder:
Make sure that the disposable CO2 pressurised gas cylinder is completely empty. There should be no CO2 bubbles rising in the reactor or diffuser.
Disconnect the CO2 hose from the pressure regulator fitting and turn the pressure regulator counterclockwise off the Cylinder. Dispose of the empty cylinder according to your local regulations. Connect a new cylinder as described in chap. 3.
Refillable CO2 pressurised gas cylinder:
Close the cylinder valve and disconnect the CO2 hose from the pressure regulator. Open the adjusting screw and release any pressure still present in the pressure regulator until both pressure gauges indicate 0 bar. Loosen the connecting nut of the pressure regulator from the cylinder valve. Hand over the reusable CO2 pressurised gas cylinder for refilling.
If there is no filled reusable CO2 pressurised gas cylinder available, you can also connect a disposable cylinder. Use the enclosed Allen key (size 6) to remove the cylinder connection nut from the pressure regulator. The thread that comes free will fit the disposable CO2 pressurised gas cylinder.
Connect the filled reusable CO2 pressurised gas cylinder or the disposable CO2 pressurised gas cylinder as described in chapter 3.

Technical data:

| Pressure regulator JBL PROFLORA CO2 REGULATOR BASIC:

  • Pre-assembled thread adapter JBL PROFLORA CO2 ADAPT U – M for cylinder connection thread W21.8 x 1/14“ to M10x1.
  • Preset working pressure: approx. 1.5 bar.
  • Fine needle valve.
  • Connection thread for hose screw connection: 1/8“.
  • Hose screw connection for hose 4/6 mm.

---|---
| Pressure regulator JBL PROFLORA CO2 REGULATOR ADVANCED:

  • Pre-assembled thread adapter JBL PROFLORA CO2 ADAPT U – M for cylinder connection thread W21.8 x 1/14“ to M10x1.
  • Pressure gauge cylinder pressure: 0 – 160 bar.
  • Pressure gauge working pressure: 0 – 4 bar.
  • Adjusting screw for working pressure.
  • Fine needle valve.
  • Connection thread for hose screw connection: 1/8“.
  • Hose screw connection for hose 4/6 mm.

| Pressure regulator JBL PROFLORA CO2 REGULATOR PROFESSIONAL:

  • Pre-assembled thread adapter JBL PROFLORA CO2 ADAPT U – M for cylinder connection thread W21.8 x 1/14“ to M10x1.
  • Pressure gauge cylinder pressure: 0 – 160 bar.
  • Pressure gauge working pressure: 0 – 4 bar.
  • Adjusting screw for working pressure.
  • Precision needle valve.
  • Connection thread for hose screw connection: 1/8“.
  • Hose screw connection for hose 4/6 mm.
  • Pre-assembled solenoid valve JBL PROFLORA CO2 VALVE
    o Voltage: 12 V DC.
    o Power consumption: 0.8 W.
    o Hose screw connection outlet: for hose 4/6 mm.
    o Inlet thread: 1/8“.
    o Closed when currentless (NC).
    o Power supply unit: Primary: 100 – 240 V AC, 47 – 60 Hz, 0.25 A Secondary: 12 V DC, 0.3 A, 3.6 W

Manufacturer Guarantee

In addition to the legal claims of the customer against the seller the guarantee covers the delivery of goods which are free of defects and does not affect the statutory claims for defects in accordance with § 437 BGB.
We, JBL GmbH & Co. KG Dieselstr. 3, 67141 Neuhofen, Germany offer the end user a guarantee of 2 years from the date of purchase for functionality and absence of defects for the products listed below.
Furthermore we offer the end user, after a successful product registration for the device within the statutory warrantee period, under www.jbl. de/?mod=productsregistration&func=landing&lang=en&country=gb, an extended 4 years guarantee from the date of purchase.

JBL PROFLORA CO2 REGULATOR BASIC
JBL PROFLORA CO2 REGULATOR ADVANCED
JBL PROFLORA CO2 REGULATOR PROFESSIONAL

Wear parts, such as seal rings, are excluded from the guarantee.
The guarantee includes the repair at our discretion by replacement (free delivery of a comparable product) or its overhaul in accordance with the technical requirements.
The remaining period of the original guarantee period applies for the part to be overhauled or replaced under this guarantee.
The guarantee does not include the compensation of direct or indirect consequential damages.
The guarantee only applies on sales to customers within the European Union.
The guarantee is void, if the product was not correctly installed, maintained or cleaned, intentionally damaged or modified in any way not according to the intended purpose by the customer or third parties.
Please contact your specialist retailer during the guarantee period by presenting a valid purchase receipt or contact us under www.jbl.de/en/support/ service-kundenservice

BL GmbH & Co. KG
Dieselstr. 3
D-67141 Neuhofen
Germany

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals