CleanPro T-Bar Clip Grid Mount Recessed Cleanroom LED Luminaire Instruction Manual

June 1, 2024
CleanPro

CleanPro T-Bar Clip Grid Mount Recessed Cleanroom LED Luminaire

CleanPro-T-Bar-Clip-Grid-Mount-Recessed-Cleanroom-LED-Luminaire-
PRODUCT

Specifications

  • Product: T-Bar Clips
  • Manufacturer: L.A. Lighting
  • Country of Origin: USA
  • Compliance: BAA Compliant

Product Usage Instructions

Installation Instructions
Before starting the installation process, ensure you have read and understood all warnings and instructions provided in the manual. Follow these steps to install the T-Bar clips securely:

Step 1: Preparation

  • Disconnect the power source to avoid any electrical shock.
  • Gather the necessary tools, including screws to attach the clips to the luminaire housing.

Step 2: Attaching T-Bar Clips

  1. Lay the luminaire into the T-Bar grid.
  2. Screw the T-Bar clips into the housing of the luminaire.
  3. Screw the clips to the load-bearing main runners of the T-Bar grid.

Step 3: Sealing Holes (for specific applications)
For applications like cleanrooms or wet locations, ensure to seal any holes in the housing appropriately to prevent any ingress of unwanted substances.

Step 4: Compliance Check
Verify local building codes to confirm if additional mounting hardware such as safety cables are required for installation.

Frequently Asked Questions (FAQ)

  • Q: Are T-Bar clips necessary for installing grid-mounted luminaires?
    A: Yes, T-Bar clips are essential for securing grid-mounted luminaires to suspended T-Bar grids as required by local building codes.

  • Q: What should be done if additional mounting hardware is required?
    A: If local building codes mandate additional mounting hardware like safety cables, ensure compliance with those requirements during installation.

IMPORTANT INSTRUCTION

Read all instructions and warnings before attempting installation. Failure to heed warnings may increase the risk of electrical shock, fire, personal injury, or death.

  • Installation requires knowledge of the design and operation of the product’s electrical systems and the hazards involved, and should only be performed by a qualified electrician.
  • Always disconnect power before attempting installation or service. Electrical shock resulting in serious injury or death can occur if power is not disconnected.
  • Make all electrical and grounded connections by the National Electrical Code (NEC) and any applicable local code requirements. All wiring connections should be capped with UL-approved wire connectors.
  • The product must be installed according to local code requirements, including the use of safety cables, T-Bar clips, or other mounting methods when necessary.
  • Verify that the supply voltage is correct by comparing it with the information on the product label.
  • To prevent wiring damage or abrasion, do not expose wiring to the edges of sheet metal or other sharp objects.
  • Only those holes indicated in the installation instructions should be made or altered during installation. Do not make or alter any existing holes in wiring enclosures or electrical components.
  • When drilling holes for mounting a luminaire or installing an LED Retrofit Kit, select drill areas that are clear of wiring and electrical components.
  • Wear gloves and safety glasses at all times when removing luminaire or replacement parts from cartons, installing, servicing, and performing maintenance.
  • Allow the luminaire to cool before handling. Do not touch the enclosure or light source while hot.
  • For cUL units, the LED Retrofit Kit is acceptable as a component of a luminaire where the suitability of the combination shall be determined by CSA or authorities having jurisdiction.
  • This product may contain chemicals known to the State of California to cause cancer, birth defects, and/or other reproductive harm. Thoroughly wash hands after installing, handling, cleaning, or otherwise touching this product.

T-Bar Clip Installation Instructions

  • T-Bar clips are used to secure grid-mounted luminaires to suspended T-Bar grids. Also known as earthquake clips or hurricane clips, they are often required by local building codes. The exact shape of the clips varies depending on the luminaire.
  • L.A. Lighting provides T-Bar clips with all grid-mounted luminaires, as well as the screws needed to attach the clips to the luminaire housing. The installer must provide the screws needed to secure the clips to the T-Bar grid.
  • Installation of T-Bar clips is simple: after the luminaire is laid into the T-Bar grid, the clips are screwed into the housing.
  • The clips are then screwed to the load-bearing main runners of the grid. For applications such as cleanrooms and wet locations, the holes in the housing must then be appropriately sealed. Be sure to check local building codes to determine if additional mounting hardware, such as safety cables, is required

CROSS SECTION

CleanPro-T-Bar-Clip-Grid-Mount-Recessed-Cleanroom-LED-
Luminaire-FIG- \(1\)

PERSPECTIVE DRAWING

CleanPro-T-Bar-Clip-Grid-Mount-Recessed-Cleanroom-
LED-Luminaire-FIG- \(2\)

CleanPro® Cleanroom Products
121 Cheshire Lane, Ste. 400 Minnetonka, MN 55305
888-903-0333
www.gotopac.com

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals