Uponor T-26 Base Thermostat Digital Programmable User Guide

June 11, 2024
uponor

Uponor Base thermostat digital programmable T-26, 230 V
Guick guide

Uponor T 26 Base Thermostat Digital Programmable -

Uponor T 26 Base Thermostat Digital Programmable -
fig1

Pos A Pos B
Floor sensor (optional) Remote sensor (optional)

Icons

| Heat on
---|---
| Frost protection on
| Key lock
| Floor set temperature

Time & temperature schedule

Default screen

  1. Press twice
  2. Use to adjust time
  3. Press H to accept
  4. Use to adjust day of the week
  5. Press A to exit

Uponor T 26 Base Thermostat Digital Programmable -
fig4

  1. Press once

  2. Use to adjust wake time

  3. Use H to accept

  4. Use to adjust temperature

  5. Press H to accept

  6. Press to adjust leave time

  7. Press H to accept

  8. Use to adjust temperature

  9. Press H to accept
    N.B. Uponor recommend reducing the occupied temperature by 4 °C

Uponor T 26 Base Thermostat Digital Programmable -
fig6

  1. Use to adjust return time
  2. Press H to accept
  3. Use to adjust temperature
  4. Press H to accept

Uponor T 26 Base Thermostat Digital Programmable -
fig7

  1. Use to adjust sleep time
  2. Press H to accept
  3. Use to adjust temperature
  4. Press H to accept

Uponor T 26 Base Thermostat Digital Programmable -
fig8

  1. Repeat page 8 to 15 for weekend time and temperature schedule
  2. Press A at end of sequence to store and exit

Uponor T 26 Base Thermostat Digital Programmable -
fig9

Standby mode

  1. Press and hold to switch off

Settings

  1. Press and hold to switch off
  2. Press and hold until the screen shown above is displayed

Sensor selection

Uponor T 26 Base Thermostat Digital Programmable -
fig11

  1. Select function 06 by pressing

  2. Use to select sensor mode
    00 = built in air sensor only
    01 = remote air sensor only
    02 = floor sensor only
    03 = floor sensor and built in air sensor
    04 = floor and remote air sensor

  3. Press A to store and exit

  4. Press to return to main screen

Uponor T 26 Base Thermostat Digital Programmable -
fig12

Floor limiting sensor

  1. Select function 07 by pressing
  2. Use to adjust floor temperature
  3. Press A to store and exit
  4. Press to return to main screen

Uponor T 26 Base Thermostat Digital Programmable -
fig13

Temperature set-point

  1. Press to adjust temperature
  2. Press A to accept
  3. Temperature is now set until the next scheduled change

Uponor T 26 Base Thermostat Digital Programmable -
fig14

Floor temperature

  1. Press and hold A to view floor temperature
  2. Floor temperature will display for 5 seconds

Uponor T 26 Base Thermostat Digital Programmable -
fig15

Frost protection

Press to enable frost protection
Press to disable frost protection

Feature Description Setting
1 Temperature format 00 = °C

01 = °F
2| Switching
differential| 01-03 °C (01 °C default)
3| Frost mode| 00 = enabled (default)
01 = disabled
4| Output delay| 00-15 minutes (00 default)
5| Up/down temp. limit| 00-10 °C (00 °C default)
6| Sensor selection| 00 = built in air sensor (default)
01 = remote air sensor
02 = floor sensor only
03 = floor sensor and built in air sensor
04 = floor sensor and remote air sensor
7| Floor limiting sensor| 20-45 °C (27 °C default)
8| Optimum start| 00-03 (00 hours default)
9| Rate of change| Minutes to raise by 1 °C
10| Mode select| 00 = 5/7 day programming (default)
01 = 7 day programming
02 = 24 h programming
11| Thermostat mode| 00 = manual
01 = programmable (default)

Uponor reserves the right to make changes, without prior notification, to the specification of incorporated components in line with its policy of continuous improvement and development.

Ref: UPN PRT-EV2
Uponor GmbH
Industriestraße 56,
D-97437 Hassfurt, Germany
1095608 v5_04_2022_INT
Production: Uponor/ELO
www.uponor.com