Uponor Base thermostat digital programmable T-26, 230 V
Guick guide
Pos A | Pos B |
---|---|
Floor sensor (optional) | Remote sensor (optional) |
Icons
| Heat on
---|---
| Frost protection on
| Key lock
| Floor set temperature
Time & temperature schedule
Default screen
- Press twice
- Use to adjust time
- Press H to accept
- Use to adjust day of the week
- Press A to exit
-
Press once
-
Use to adjust wake time
-
Use H to accept
-
Use to adjust temperature
-
Press H to accept
-
Press to adjust leave time
-
Press H to accept
-
Use to adjust temperature
-
Press H to accept
N.B. Uponor recommend reducing the occupied temperature by 4 °C
- Use to adjust return time
- Press H to accept
- Use to adjust temperature
- Press H to accept
- Use to adjust sleep time
- Press H to accept
- Use to adjust temperature
- Press H to accept
- Repeat page 8 to 15 for weekend time and temperature schedule
- Press A at end of sequence to store and exit
Standby mode
- Press and hold to switch off
Settings
- Press and hold to switch off
- Press and hold until the screen shown above is displayed
Sensor selection
-
Select function 06 by pressing
-
Use to select sensor mode
00 = built in air sensor only
01 = remote air sensor only
02 = floor sensor only
03 = floor sensor and built in air sensor
04 = floor and remote air sensor -
Press A to store and exit
-
Press to return to main screen
Floor limiting sensor
- Select function 07 by pressing
- Use to adjust floor temperature
- Press A to store and exit
- Press to return to main screen
Temperature set-point
- Press to adjust temperature
- Press A to accept
- Temperature is now set until the next scheduled change
Floor temperature
- Press and hold A to view floor temperature
- Floor temperature will display for 5 seconds
Frost protection
Press to enable frost protection
Press to disable frost protection
Feature | Description | Setting |
---|---|---|
1 | Temperature format | 00 = °C |
01 = °F
2| Switching
differential| 01-03 °C (01 °C default)
3| Frost mode| 00 = enabled (default)
01 = disabled
4| Output delay| 00-15 minutes (00 default)
5| Up/down temp. limit| 00-10 °C (00 °C default)
6| Sensor selection| 00 = built in air sensor (default)
01 = remote air sensor
02 = floor sensor only
03 = floor sensor and built in air sensor
04 = floor sensor and remote air sensor
7| Floor limiting sensor| 20-45 °C (27 °C default)
8| Optimum start| 00-03 (00 hours default)
9| Rate of change| Minutes to raise by 1 °C
10| Mode select| 00 = 5/7 day programming (default)
01 = 7 day programming
02 = 24 h programming
11| Thermostat mode| 00 = manual
01 = programmable (default)
Uponor reserves the right to make changes, without prior notification, to the specification of incorporated components in line with its policy of continuous improvement and development.
Ref: UPN PRT-EV2
Uponor GmbH
Industriestraße 56,
D-97437 Hassfurt, Germany
1095608 v5_04_2022_INT