FOS technologies Spot 150 Pro Moving Light User Manual

June 11, 2024
FOS technologies

FOS-technologies-LOGO

FOS technologies Spot 150 Pro Moving Light

FOS-technologies-Spot-150-Pro-Moving-Light-PRO

Safety instructions

Thank you for choosing our FOS Spot 150 Pro. FOR YOUR OWN SAFETY, PLEASE READ THIS USER
MANUAL CAREFULLY
BEFORE YOU INITIAL START-UP!

CAUTION! Be careful with your operations. with a high voltage you can suffer a dangerous electric shock when touching the wires! This device has left our premises in absolutely perfect condition. In order to maintain this condition and to ensure a safe operation, it is absolutely necessary for the user to follow the safety instructions and warning notes written in this manual.
CAUTION! Keep this device away from rain and moisture! Unplug mains lead before opening the housing!

Important

  • The manufacturer will not accept liability for any resulting damages caused by the non-observance of this manual or any unauthorized modification to the device.
  • Please consider that damages caused by manual modifications to the device are not subject to warranty.
  • During the operation the housing becomes hot). Allow the fixture to cool approximately 20 minutes prior to manipulate with it.
  • Make sure that the available voltage is not higher than stated on the rear panel.
  • WARNING! This unit does not contain an ON/OFF switch. Always disconnect power input cable to completely remove power from unit when not in use or before cleaning or servicing the fixture.
  • Make sure that the power- cord is never crimped or damaged by sharp edges. Check the device and the power cord from time to time.
  • Always disconnect from the mains, when the device is not in use or before cleaning it. Only handle the power cord by the plug. Never pull out the plug by tugging the power cord.
  • This device falls under protection class I. Therefore it is essential to connect the yellow/green conductor to earth.
  • The electric connection, repairs and servicing must be carried out by a qualified employee.
  • Do not connect this device to a dimmer pack.
  • Do not switch the fixture on and off in short intervals as this would reduce the lamp’s life.
  • During the initial start-up some smoke or smell may arise. This is a normal process and does not necessarily mean that the device is defective.
  • Do not touch the device’s housing bare hands during its operation (housing becomes hot)!
  • For replacement use lamps and fuses of same type and rating only.

CAUTION! EYE DAMAGES!
Avoid looking directly into the light source (meant especially for epileptics)!

UNPACKING

FOS Spot 150 Pro adopts a 150W white LED amp which features high brightness and stability. Please carefully unpack it when you receive the fixture and check whether it is damaged during the transportation. And please check whether the following items are included inside the box:FOS-technologies-
Spot-150-Pro-Moving-Light- \(1\)

FOS Spot 150 Pro is made of a new type of high-temperature strength of engineering plastics and cast aluminum casing with nice outlook. The fixture is designed and manufactured strictly following CE standards, complying with the international standard DMX512 protocol. It’s available independently controlled and linkable with each other for operation. And it is applicable for large-scale live performances, theaters, studio, nightclubs and discos. This manual covers important information on installation and applications. Meanwhile, please keep this manual well for future needs.

TECHNICAL INFORMATION

SPECIFICATIONS:

  • A 150W white LED lamp , 7500K, 50000 hours life span
  • Input Voltage: AC90-260V 50/60Hz
  • Power Consumption: 195W
  • Control Signal: DMX512, master-slave and sound activated or auto operation (7 built-in programs)
  • Control Channel: 14/12 DMX channels USITT DMX. 512
  • Dimensions: 266(DJ177(W) 362(H)mm
  • Packing Dimensions: 350(D) 245(W) 450(H)mm
  • Net Weight: 6.6kgs
  • Gross Weight: 7.6kgs

FEATURES:

  • Low power consumption
  • 13° Beam angle
  • Motorized focus from near to far (2.5M-30M)
  • 3-Facet prism with variable speed and direction
  • 25T/sec high speed LED shutter/strobe effect with variable speed
  • Preset variable/random strobe and dimming pulse effect
  • 1.8′ TFT LCD display (160 128pix)
  • Powercon IN
  • 3-Pin XLR connectors IN/OUT
  • IP20 protection rating
  • 55dB at 3’dB rating
  • 1*1/4 turn fastening Omega clamps
  • 1’Safety attachment point available

MOVEMENT:

  • Smooth and precise resolution for PAN/TILT movement
  • 360 /540°/630° PAN and 90°/180° /270° TILT
  • movement optional
  • Scan position memory, auto reposition after
  • unexpected movement

COLORS;

  • 1 Color wheel with 8 colors plus open.

GOBOS;

  • 1 Rotating Gobo Wheel with 6 gobos plus open
  • 1 Static Gobo Wheel with 10 gobos plus open

FUNCTION:

  • Improved optics and flat beam field
  • Variable direction rainbow effect with speed adjustable
  • Vector mode with blackout MIB function
  • Constant temperature readout and management function
  • Fan cooling system
  • -35-45°C max ambienttemperature

FOS-technologies-Spot-150-Pro-Moving-Light- \(3\)

PHOTOMETRIC DIAGRAM

FOS-technologies-Spot-150-Pro-Moving-Light- \(4\)

OPERATION INSTRUCTIONS

  • FOS Spot 150 Pro is for beam effect for on-site decoration purpose.
  • Don’t turn on the fixture if it’s been through severe temperature difference like after transportation because it might damage the light due to the environment changes. So make sure to operate the fixture until it is in normal temperature.
  • This light should be keep away from strong shaking during any transportation or movement. Don’t pull up the light by only the head, or it might cause damages to the mechanical parts.
  • Don ‘expose the fixture in overheat, moisture or an environment with too much dust when installing it. And
  • don’t lay any power cables on the floor. Or it might cause electronic shock to the people.
  • Make sure the installation place is in good safety condition before installing the fixture.
  • Make sure to put the safety chain and check whether the screws are screwed properly when installing the fixture.
  • Make sure the lens are in good condition. It’s recommended to replace the units if there are any damages or severe scratch.
  • Make sure the fixture is operated by qualified personnel who knows the fixture before using.
  • Keep the original packages if any second shipment is needed.
  • Don ‘try to change the fixtures without any instruction by the manufacturer or the appointed repairing agencies.
  • It is not in warranty range if there are any malfunctions from not following the user manual to operate orany illegal operation, like shock short circuit, electronic shock, lamp broke, etc.

INSTALLATIONS

FOS-technologies-Spot-150-Pro-Moving-Light- \(5\)

Cautions:

  • For added protection mount the fixtures in areas outside walking paths, seating areas, or in areas were the fixture might be reached by unauthorized personnel.
  • Before mounting the fixture to any surface, make sure that the installation are a can hold a minimum point load of 10 times the device’s weight.
  • Fixture installation must always be secured with a secondary safety attachment, such as an appropriate safety cable.
  • Never stand directly below the device when mounting, removing, or servicing the fixture.
  • from a ceiling, or set on a flat level surface (see illustration below). Be sure this fixture is kept at least 0.5m (1.5 ft) away from any flammable materials (decoration etc.).
    Always use and install the supplied safety cable as a safety measure to prevent accidental damage and/or injury in the event the clamp fails.

Mounting points:
Overhead mounting requires extensive experience, including amongst others calculating working load limits, a fine knowledge of the installation material being used, and periodic safety inspection of all installation material and the fixture. If you lack these qualifications, do not attempt the installation yourself. Improper installation can result in bodily injury. Be sure to complete all rigging and installation procedures before connecting the main power cord to the appropriate wall outlet.

Clamp Mounting:
FOS Spot 150 Pro provides a unique mounting bracket assembly that integrates the bottom of the base, and the safety cable rigging point in one unit (see the illustration below). When mounting this fixture to trus be sure to secure an appropriately rated clamp to the included omega bracket using a M10 screw fitted through the center hole of the “Hanging Kit*. As an added safety measure be sure to attached at least one properly rated safety cable to the fixture using on of the safety cable rigging point integrated in the base assembly.

CONTROL CONNECTION

FOS-technologies-Spot-150-Pro-Moving-Light- \(7\)

Connect the provided XL cable to the female 3-pin XL output of your controller and the other side to the male 3-pin XLR input of the moving head. You can chain multiple Moving head together through serial linking. The cable needed should be a two-core, screened cable with XL input and output connectors. Please refer to the diagram below. DMX-512 connection with DMX terminator. For installations where the DMX cable has to run a long distance or is in an electrically noisy environment, such as in a discotheque, it is recommended to use a DMXterminator. This helps in preventing corruption of the digital control signal by electrical noise. The DMX terminator is simply an XL plug with a3 resistor connected between pins 2 and 3, which is then plugged into the output XL socket of the last fixture in the chain. Please see the illustrations below.FOS-technologies-Spot-150-Pro-Moving-Light-
\(8\)

FOS-technologies-Spot-150-Pro-Moving-Light- \(9\) FOS-technologies-Spot-150-Pro-Moving-Light- \(10\)

DMX PROTOCOL

FOS-technologies-Spot-150-Pro-Moving-Light- \(11\) FOS-technologies-Spot-150-Pro-Moving-Light- \(12\) FOS-technologies-Spot-150-Pro-Moving-Light- \(13\) FOS-technologies-Spot-150-Pro-Moving-Light- \(14\) FOS-technologies-Spot-150-Pro-Moving-Light- \(15\) FOS-technologies-Spot-150-Pro-Moving-Light- \(16\)

Maintenance and cleaning

Itis absolutely essential that the fixture is kept clean and that dust, dirt and smoke-fluid residues must not build up on or within the fixture. Otherwise, the fixture’s light-output will be significantly reduced. Regular cleaning will not only ensure the maximum light-output, but will also allow the fixture to function reliably throughout its life.A soft lint-free cloth moistened with any good glass cleaning fluid is recommended, under no circumstances should alcohol or solvents be used!

DANGER!
Disconnect from the mains before starting any maintenance work

  • The front objective lens will require weekly cleaning as smoke fluid tends to building up residues, reducing the light output very quickly. The cooling fans should be cleaned monthly.
  • The interior of the fixture should be cleaned at least annually using a vacuum cleaner or an air jet.
  • Remove dust and dirt from the fans and cooling vents using a soft brush and vacuum cleaner.
  • Important! Check the air filters periodically and clean before they become clogged!
  • Clean two air filters placed in the fixture’s covers and two in the fixture base. Use a vacuum cleaner, or compressed air or you can wash them and put back dry.
  • After replacing the air filters, reset the elapsed time counter in the menu “Information* (Information-••>Air Filters-•>Elapsed Time).

Replacing the fuse. Before replacing the fuse, unplug mains lead.

  1. Remove the fuse holder on the rear panel of the base with a fitting screwdriver from the housing (anti-clockwise).
  2. Remove the old fuse from the fuse holder.
  3. Install the new fuse in the fuse holder (only the same type and rating).
  4. Replace the fuse holder in the housing and fix it.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

FOS technologies User Manuals

Related Manuals