mr steam AromaSteam Fragrance Metering Pump System User Manual

June 11, 2024
Mr.Steam

Installation, Operation & Maintenance
Aroma Steam
Manual’
Fragrance Metering Pump System for
Residential and Day Spa Steam Rooms
Part Number MS AROMA (120V)

Aroma Steam Fragrance Metering Pump System

IMPORTANT: Leave this material with the home owner.
WARNING
This installation, operation and maintenance manual is for general reference. The installation, operation and maintenance manual supplied with the product must be used for installation, operation and maintenance purposes. Failure to use the installation, operation and maintenance manual supplied may result in a property damage or personal injury.

BEFORE INSTALLING

Carefully inspect the Aroma Steam pump and packaging for shipping damage. In the event of shipping damage, please contact the carrier for claim information. Our customer service department can assist you with product replacement.
Read these instructions before installation or service. Although the Aroma Steam pump has been fully qualified for shipment by Mr Steam, the following must be reviewed for proper, safe and enjoyable steam bathing:

  1. Verify that the model and accessories specifications are correct for the application.
  2. The physical size of the unit, clearance for plumbing service- ing, its distance from the steam room and fragrance location must all be considered before final installation.
  3. Consider any controls and accessories before initiating installation. Read the Installation and Operation Manual of all controls and accessories available at www.mrsteam.com technical downloads.

IMPORTANT NOTES:
This document contains important safety, operation and maintenance information. After installation leave this document with the homeowner. Do not discard this document. The following general information should be used in conjunction with consultations with an architect, designer and contractor in determining factors necessary in providing a suitable and safe steam room. Mr Steam Aroma Steam pumps are intended to be operated with Mr Steam steam® , Air Tempo® , tempo Plus® and tempo® controls only, and are to be installed strictly in accordance with the specific instructions contained in this manual and as supplied in the manuals provided with the controls or accessories.
WARNING
This room is equipped with a fragrance dispensing system. Leave the room immediately if you have any adverse or allergic reactions, including difficulty breathing or eye, nasal, throat, or skin irritation and seek medical attention.
Mr. steam° 43-20 34th Street. Long Island City NY 11101 1-800-76 STEAM www.mrsteam.com PUR wows 1/19
IMPORTANT NOTE:
This “peel and stick” warning label shall be posted in a conspicuous location next to the steam room door.

Box Contents

mr steam AromaSteam Fragrance Metering Pump System - Box
Contents

Additional Items included but not shown:

  • 2x Mounting Screws and Anchors for Caddy and Pump
  • Fuse

IMPORTANT NOTE: As you follow these instructions, you will notice warning and caution symbols. This blocked information is important for the safe and efficient installation and use of the pump, fragrance and caddy. These are types of potential hazards that may occur during installation and operation:
WARNING states a hazard may cause serious injury or death if precautions are not followed.
CAUTION signals a situation where minor injury or product damage may occur if you do not follow instructions.
IMPORTANT NOTE: This highlights information that is especially relevant to a problem-free installation.
All information in these instructions is based on the latest product information available at the time of publication. Mr Steam reserves the right to make changes at any time without notice.
WARNING

FLAMMABLE LIQUID AND VAPOR

  • Keep the pump and fragrance away from heat, sparks, electrical outlets, open flames such as candles and hot surfaces.
  • No smoking.
  • Keep Quit of the Reach of Children.
  • Use only non-sparking tools. Take precautionary measures against static discharge.
  • Contains denatured ethyl alcohol
  • In case of fire: Use CO2, dry chemical, alcohol foam, and water spray for extinction.
  • Always store the Mr Steam Aroma fragrances in a secure location. Keep container tightly closed and store in a cool, dry and well-ventilated place.
  • Always use this Caddy.

WARNING

  • Avoid fragrance contact with eyes. May cause mild eye irritation. Ingestion may cause irritation, nausea, vomiting

  • Fragrance vapors may cause drowsiness, allergic reach- tions, difficulty breathing or skin irritation. If condition persists get medical attention.

  • The Fragrance Safety Data Sheet provides comprehend- sive information about Mr Steam Aroma fragrances.

  • Contact 1-800-767-8326 or go online at www.mrsteam. com for a copy of the Safety Data Sheet.

  • Mr Steam fragrances (MS OIL 1- 5) are only for use with the Mr Steam Aroma Steam dispensing pump (part number MS AROMA and MS AROMAC). Never use

  • Merstham fragrances in any other pump, spray or dis- pending device. The use of Mr Steam fragrances in any other device may cause personal injury.

  • The use of any fragrances other than Mr Steam fragrance- es with a Mr Steam Aroma Steam dispensing pump may introduce excessive concentration of fragrances into the steam room, resulting in personal injury.

  • Keep out of the reach of children.

  • Always install the Check Valve. Failure to install theCheck Valve may result in excessive fragrance delivery into the steam room and cause dizziness and/or personal
    injury.

  • The Aroma Steam pump has been factory set to deliver a suitable amount of fragrance into a typical sized residential or Day Spa steam room. Start with the pump volume at a very low setting. Gradually increase the volume setting until a comfortable fragrance level is reached. Do not exceed the “Recommended Setting” indicated on the pump volume

  • Do Not alter or modify any MrSteam product. Doing so may result in a personal injury.

  • Discontinue use of the steam generator and control if the steam generator or control are damaged or otherwise not functioning properly. Doing so may result in an inoperative or hazardous installation

  • ELECTRICAL SHOCK HAZARD. Mr Steam Aroma Steam pumps are connected to 120V line voltage and contain live electrical components. All installation and service to be per- formed by qualified and licensed electricians and plumbers only. Installation or service by unqualified persons or failure to use Mr Steam parts may result in property damage or in a hazardous condition.

  • Install according to Local and National plumbing and electrical codes.

FIRST AID
IN CASE OF EYE CONTACT: Rinse the eyes immediate- ly with plenty of water, also under the eyelids, for at least 15 minutes. If eye irritation persists: Get medical attention
IN CASE OF SKIN CONTACT: Remove/Take off mime- dirtily all contaminated clothing. Rinse skin with soap and water or shower. If skin irritation persists, get media-
Cal attention.
IF SWALLOWED: Do not induce vomiting. Rinse mouth thoroughly with water. If conscious, give large amounts of water. If symptoms persist, call a physician.
IMPORTANT NOTES:

  • Merstham Aroma fragrances are only for use in resident- tail and day spa installations. Do Not use Mr Steam Aroma fragrances in commercial installations.
  • Not for use in acrylic or fiberglass rooms. Check with the room manufacturer to determine compatibility of these fragrances with room construction materials.
  • Do Not alter or modify any Mr Steam product. Doing so will void the warranty.
  • Mr Steam Aroma fragrances must be disposed of as hazardous waste.

Aroma Steam System Overview

mr steam AromaSteam Fragrance Metering Pump System -
Overview

General System Dimensions

mr steam AromaSteam Fragrance Metering Pump System -
Dimensions

WARNING STICKER
The warning label (supplied on page 2) shall be posted in a conspicuous location next to the steam room door.
WARNING
This room is equipped with a fragrance dispensing system.
Leave the room immediately if you have any adverse or allergic reactions, including difficulty breathing or eye, nasal, throat, or skin irritation and seek medical attention.
mr steam 5.0 340 S ng s Getty N 1101 1-80-16 STERN st. i s 15
PUMP LOCATION AND INSTALLATION

  1. Keep the Aroma Steam System away from heat, sparks, Elec- trial outlets, open flames such as candles and hot surfaces.
  2. Locate the Fragrance and Caddy to monitor the consumption of fragrance and for easy replacement.
  3. The Aroma Steam System should not be installed in areas accessible to children. A locked room is strongly recommend- ed (i.e. utility room)
  4. The Aroma Steam System is designed and intended for indoor use only and is to be located indoors in a dry clean location and not subject to moisture, condensation or similar high humidity environments
  5. Do not install the Aroma Steam System outdoors.
  6. Do not install the Aroma Steam System in a location where water could freeze.
  7. Do not install the Aroma Steam System near corrosive material- ales and chemicals. Installation in areas having high Concentra- tions of chlorine (such as pool equipment room) should be avoided.
  8. Attach the Aroma Steam Pump onto a secure vertical surface.
  9. Use only non-sparking tools. Take precautionary measures against static discharge.

Installing the 90 degree T and Check Valve

  1. For optimal results locate a brass 90 degree T (not provide- ed) in the steam supply line within 5-10 feet of the steam head. If using copper tubing for steam lines, install a female 1/2 NPT or 1/4 NPT reducing Tee in the steam line facing downward.

  2. T must face downward as shown.
    IMPORTANT NOTE: Follow the installation instructions for the steam pipeline in the Mr Steam Steam Bath Installation and Operation Manual. Visit www.mrsteam.com to download this document.

  3. Install Check Valve into 90° T/adaptor.

WARNING
The Check Valve prevents excessive amounts of fragrance from entering the steam line and steam room. Never install the Aroma Steam System without the Check Valve.
Failure to install the Check Valve may result in excessive fra- grace delivery into the steam room and cause dizziness and/or personal injury.
PRESSURE TUBE ASSEMBLY
For your convenience the pressure tube assembly is provided pre- assembled. If additional tubing is needed please contact Mr Steam Technical service at 1-800-767-8326 or 1-800-727-8326.
Installation of Pressure Tube to the Pump

  1. Insert the pressure tube through the hole of the pump tight- ending nut and collar and filmy push the tube onto the tube holder.
  2. Screw the pump tightening nut onto the pump and tighten the nut by HAND only.

Installation of Pressure Tube to the 90° T

  1. Insert the pressure tube through the Check Valve tightening nut and collar and firmly push the pressure tube onto the tube holder.
  2. Screw the Check Valve tightening nut onto the Check Valve.

IMPORTANT NOTE:   To prevent connection from leaking, insert tubing holder completely into tubing until it reaches the bottom. Lubricate the ID of the tubing as required with soap to facilitate insertion.
IMPORTANT NOTE: To prevent damage do not use tools to tighten the nut.

mr steam AromaSteam Fragrance Metering Pump System -
Overview1

SUCTION TUBE ASSEMBLY

For your convenience the suction tube assembly is provided preassembled. If additional tubing is needed please contact Mr Steam Technical service at 1-800-767-8326 or
1-800-727-8326.?
Installation of Suction Tube to the Pump

  1. Insert the suction tube through the pump tightening nut and collar and firmly push the tube onto the tube holder.
  2. Screw the suction tube tightening nut to the suction side of the pump.

IMPORTANT NOTE: HAND-TIGHTEN ONLY.
Installation of Suction Tube into the Fragrance Container

  1. Locate the “container cap” with the hole included with the bottle of fragrance.
  2. Insert the suction tube through the hole in the container cap.
  3. Remove the foot valve cap and insert the suction tube through the cap. Push the suction tube onto the foot
  4. Unscrew the cap from the fragrance container and discard.
  5. Screw the cap onto the fragrance container.
  6. Make sure the Foot Valve rests on the bottom of the valve. Tighten the cap onto the foot valve. fragrance container.

IMPORTANT NOTE: To prevent connection from leaking, insert tubing holder completely into tubing until it reaches the bottom. Lubricate the ID of the tubing as required with soap to facilitate insertion.
IMPORTANT NOTE: To prevent damage do not use tools to tighten the nut.

mr steam AromaSteam Fragrance Metering Pump System -
Overview2

Priming the Pump

  1. Insure Mr Steam fragrance container is full.
  2. Insert a short piece of soft injector tube onto the tip of the injector (see Fig. 1).
  3. Insert the open end of the injector tube onto the pressure valve (see Fig. 1).
  4. Open the priming valve by turning the knob counter clockwise one full revolution.
  5. Draw liquid from the injector slowly and evenly. Continue until the injector is full of liquid.
  6. If you have drawn up the injector completely and no liquid is in the injector, remove the injector tube from the pressure valve.
  7. Drain injector. Repeat steps until the injector is filled.p
  8. Save the fragrance injector as it may be needed when new fragrances are used.
  9. Close the priming valve completely by tuming the knob clockwise.

CAUTION
Failing to close the valve will result in fragrance leaking from the priming port.
IMPORTANT NOTE:
If an extended pressure tube is special ordered then contact Mr Steam Technical Service (see page 20) for instructions for filling the pressure tube with fragrance.
Electrical Connection of Aroma Steam System
CAUTION
This Aroma Steam system is factory wired. If the power cord of the Aroma Steam pump is damaged it must be replaced by the Mr Steam service department or similarly qualified personnel in order to avoid an electric shock hazard. All Elec- trial connections to be made by a licensed, quail- feed electrician. Disconnect all power to the steam generator before making power connections.

IMPORTANT NOTE: Aroma Steam system is for use with Air Tempo® steam® and tempo Plus® con- troll’s only.

  1. Disconnect all power to the Mr Steam steam generator. Failure to disconnect power may result in an electrocution hazard. Remove the top cover.
  2. Run the request cable from the Aroma Steam pump through one of the knock outs in the side of the steam bath generator. Use a strain relief bushing or grommet to prevent chafing.
  3. Locate the two quick connect tabs labeled “AROMA” on the printed circuit board in the location shown.
  4. Connect the request cable to the terminals. The terminals are not polarized.

Powering Up the Pump
IM?ORTANT NOTE: This step only needs to be performed during installation.

  1. The pump needs to be turned on before it can be used
  2. Press and hold the power button for 3 seconds. The LED wilting on solid red.
PUMP LED LIGHT: KEY:
Flashing Green LED Pump is OFF. Press and hold the power button for 3 seconds

to turn the pump on.
Solid Red| Pump is ON, but has not been activated. To activate the pump, tum your steam generator ON from the in-shower control and press the aroma button.
Solid Green LED| Pump is on and has been activated from the in-shower control.
The LED will turn off each time the pump injects fragrance into the steam line.

Adjusting the Amount of Fragrance Delivery
The Aroma Steam system has been factory set to deliver a suitable amount of aromatic Fra- grace into a typical sized steam room. Do not exceed the maximum setting. Please con- tact the Mr Steam Technical Service Department before changing this setting. Contact the Mr Steam Technical Service Dept. at (800) 76-STEAM (East coast) or (800) 72-STEAM (West Coast) for assistance or additional information.mr steam AromaSteam Fragrance Metering Pump System -
Pump1 WARNING
Increasing the settings may introduce excessive concentration of fragrance into the steam room, resulting in a health hazard.
Activating the Pump from a Control
Air Tempo® Control

  1.  Press the ON/OFF button to turn the steam generator ON.
  2. Press the AROMA button, AROMA will be displayed on the screen when Aroma Steam is on.
  3. Aroma fragrance will automatically be pumped into the steam line at preset intervals.

steam ® Control

  1. Press the START button to turn the steam generator on.
  2. In the dashboard press the AROMA button, the button will be highlighted when Aroma Steam Pump is on.
  3. Aroma fragrance will automatically be pumped into the steam line at preset intervals.

iTempo Plus® Control

  1. Press the ON/OFF button to turn the steam generator ON.
  2. Press the AROMA button, AROMA will be displayed on the screen when Aroma Steam is on.
  3. Aroma fragrance will automatically be pumped into the steam line at preset intervals.

TROUBLESHOOTING

WARNING
TO AVOID ELECTRIC SHOCK, DISCON- NECT POWER TO PUMP BEFORE SERVICING
Pump does not prime

  1. Check if voltage is available.
  2. Check liquid level in fragrance container. Replenish liquid, if necessary.
  3. Check for air bubbles in the suction tube or the pump head. To eliminate air bubbles see: Priming Pump.
  4. Check valves for contamination. Clean valves if necessary.
  5. Check foot valve in container for contamination. Rinse foot valve under clean water.

Pump does not inject fragrance into steam room

  1. Check if voltage is available.
  2. Check liquid level in fragrance container. Replenish fragrance if necessary.
  3. Check for air bubbles in the suction tube or the pump head. To eliminate air bubbles see: Priming Pump.
  4. Check valves for contamination. Clean valves if ~ necessary.
  5. Check foot valve in container for contamination. Rinse foot valve under clean water.
  6. Check the pressure tube for kinking or jamming. Straighten or replace.
  7. Check if fragrance is freely flowing through the Check Valve when the metering pump is energized. Apply compressed air through the Check Valve. Attach the compressed air at the point of connection of the pressure tube.
  8. Ensure the pump has been powered up. See page 12.

Pump fragrance delivery too much or too little
WARNING
The Aroma Steam system has been factory set to deliver a suitable amount of aromatic fragrance into a typical sized steam room. Please contact the Mr Steam Technical Service Department before change- ing this setting. See page 12 for instructions on adjust- ing the amount of fragrance delivery.
Contact the Mr Steam Technical Service Dept. at (800) 76-STEAM (East coast) or (800) 72-STEAM (West Coast) for assistance or additional information.
WARNING
ELECTRICAL SHOCK HAZARD.
Mr Steam Aroma Steam pumps are connected to 120V line voltage and contain live electrical components. All installation and service
to be performed by qualified and licensed electricians and plumbers only. Installation or service by unqualified persons or failure to use Mr Steam parts may result in property damage or in a hazardous condition.

REPLACEMENT PARTS

mr steam AromaSteam Fragrance Metering Pump System -
PARTS

Installing the Caddy:
Box Contents:

  • Stainless steel caddy
  • Mounting screws (2)
  • Instructions

Tools required:

  • Cordless dill with a Phillips bit
  • Level
  • Use only non-sparking tools. Take pre- cautionary measures against static discharge

Locating the Caddy:

  1. Place in a location that allows visual monitoring of the fragrances level.
  2. Place in a location that allows for easy replacement of the fragrance container.
  3. The caddy should not be installed in areas accessible to children. A locked room is strongly recommended (je: utility room).
  4. The caddy must be installed below the pump. The maximum distance from the pump to the bottom of the caddy is 6 feet. (Diagram 1)
  5. The caddy is designed and intended for indoor use only. Do not install outdoors.
  6. Do not install in an unheated location where water could freeze.
  7. Locate in a area where the ambient temperature does not exceed 88″ F.

Mounting the Caddy on a Wall:

  1. Use a level to make sure the caddy is level.
  2. Use the two mounting screws provided to secure the caddy using the two holes at the top of the caddy (Diagram 2).
  3. Use anchors or other hardware as required for secure mounting. Test the caddy for secure mounting.
  4. Insert the fragrance container with the label facing outward so it is visible through the caddy window (Diagram 4). The label contains important information.
  5. Connect the fragrance container to the pump accord- ing to instructions in the Aroma Steam Fragrance Dispensing Pump Installation, Operation Manual (PUR 100402) (Diagram 5).
  6. Always keep the container in the caddy while itis connected to the dispensing pump.

WARNING
Using a fragrance container that is not secured in the caddy, or using a caddy that is not mounted may result in spillage, excessively strong vapors or a fire hazard.
Mounting the Caddy on a Floor:

  1. Use the two mounting screws provided to secure the caddy using the two holes at the bottom of the caddy (Diagram 3).
  2. Use anchors or other hardware as required for secure mounting. Test the caddy for secure mounting.
  3. Insert the fragrance container with the label facing outward in a manner it is visible through the caddy window (Diagram 4). The label contains important information.
  4. Connect the fragrance container according to instructions in the Aroma Steam Fragrance Dispensing Pump Installation, Operation Manual (PUR 100402).
  5. Always keep the container in the caddy while it is connected to the dispensing pump.

WARNING
Using a fragrance container that is not secured in the caddy, or using a caddy that is not mounted may result in spillage, excessively strong vapors or a fire hazard.

HOMEOWNER SECTION

The Aroma Steam’s state-of-the-art pump introduces fragrance into the steam pipe and into your steam shower. Mr Steam Aroma is Available in These Five Fragrances:

mr steam AromaSteam Fragrance Metering Pump System - MrSteam Aroma
Fragrances

FRAGRANCE PART NO. CONTAINER VOLUME.
Eucalyptus (MS OIL 1) 1 liter /33 fl.oz.

A deeply refreshing aroma with cleansing effects, eucalyptus may help open air passageways.

FRAGRANCE PART NO. CONTAINER VOLUME.
Lavender (MS OIL2) 1 liter /33 fl.oz.

A sweet, lightly floral scent, lavender may help soothe anxiety with its calming & restorative property

FRAGRANCE PART NO. CONTAINER VOLUME.
Evergreen (MS OIL3) 1 liter /33 fl.oz.

A refreshing blend of spruce, fir and pine reminiscent of a forest on a crisp moming.

FRAGRANCE PART NO. CONTAINER VOLUME.
Energizing Mint (VS OIL4) 1 liter /33 fl.oz.

A blend of mint, citrus and herbs that may stimulate and energize.

FRAGRANCE PART NO. CONTAINER VOLUME.
Breathe (MS OIL5) 1 liter /33 fl.oz.

A tropical combination that may help clear chest, nose and sinuses.
The Safety Data Sheet provides comprehensive information about Mr Steam Aroma fragrances.
Contact 1-800-767-8326 or go online at www.mrsteam.com for a copy of the Safety Data Sheet.
READ ME FIRST!
WARNING
As you follow these instructions, you will notice warning and caution symbols. This blocked information s important for the safe and efficient installation and operation of this generator.  These are types of potential hazards that may occur during installation and operation
WARNING
Indicates a potentially hazardous situation, which, if not avoided, could result in death or serious injury.
CAUTION
Indicates a potentially hazardous situation, which, if not avoided may resulting minor or moderate injury or product damage’s
IMPORTANT NOTE: This highlights information that is especially relevant to a problem-free installation.
All information in these instructions is based on the latest product information available at the time of publication. Mr Steam reserves the right to make changes at any time without notice.

IMPORTANT SAFETY INSTRUCTIONS

READ AND FOLLOW ALL INSTRUCTIONS
WARNING
FLAMMARBLE LIQUID AND VAPOR

  • Keep the pump and fragrance away from heat, sparks, electrical outlets, open flames such as candles and hot surfaces.
  • No smoking.
  • Keep Out of the Reach of Children.
  • Contains denatured ethyl alcohol.
  • In case of fire: Use CO2, dry chemical, alcohol foam, and water spray for extinction.
  • Always store the Mr Steam Aroma fragrances in a secure location. Keep container tightly closed and store in a cool, dry and well-ventilated place.

WARNING

  • Avoid fragrance contact with eyes. May cause mild eye irritation. Ingestion may cause irritation, nausea, vomiting.
  • Fragrance vapors may cause drowsiness, allergic reach-tions, difficulty breathing or skin irritation. If condition persists get medical attention.
  • The Fragrance Safety Data Sheet provides comprehensive information about Mr Steam Aroma fragrances. Contact 1-800-767-8326 or go online at www.mrsteam.com for a copy of the Safety Data Sheet.
  • Mr Steam fragrances (MS OIL 1- 5) are only for use with the Mr Steam Aroma Steam dispensing pump (part number MS AROMA and MS AROMAC). Never use
  • Mr Steam fragrances in any other pump, spray or dispense- ing Eve’\cu, The use of MrSt‘ea‘m fragrances in any other device may cause personal injury.
  • The use of any fragrances other than Mr Steam Fra- graces with a Mr Steam Aroma Steam dispensing pump may introduce excessive concentration of fragrances into the steam room, resulting in personal injury.
  • Keep out of the reach of children.
  • The Aroma Steam pump has been factory set to deliver a suitable amount of fragrance into a typical sized res- identical or Day Spa steam room. Start with the pump volume at a very low setting. Gradually increase the volume setting until a comfortable fragrance level is reached. Do not exceed the “Recommended Setting” indicated on the pump volume
  • Do Not alter or modify any Mr Steam product. Doing so may result in a personal injury.

FIRST AID
IN CASE OF EYE CONTACT:
Rinse the eyes immediately with plenty of water, also under the eyelids, for at least 15 minutes. f eye irritation persists: Get medical attention.
IN CASE OF SKIN CONTACT: Remove/Take off immediately all contaminated clothing. Rinse skin with soap and water or shower. If skin irritation persists, get medical attention.
IF SWALLOWED: Do not induce vomiting. Rinse mouth thoroughly with water. If conscious, give large amounts of water. If symptoms persist, call a physician.
IMPORTANT NOTES:

  • Not for use in acrylic or fiberglass rooms. Check with the room manufacturer to determine compatibility of these fragrances with room construction materials.
  • Do Not alter or modify any Mr Steam product. Doing so will void the warranty.
  • Mr Steam Aroma fragrances must be disposed of as hazardous waste.

Locating the Caddy/Fragrance:

  1. Place in a location that allows visual monitoring of the fragrances level.

  2. Place in a location that allows for easy replacement of the fragrance container.

  3. The caddy should not be installed in areas accessible to children. A locked room is strongly recommended (ie: utility room).

  4. The caddy is designed and intended for indoor use only. Do not install outdoors.

  5. Do not install in an unheated location where water could freeze.

  6. Locate in a area where the ambient temperature does not exceed 88″ F.l
    WARNING
    Using a fragrance container that is not secured in the caddy, or using a caddy that is not mounted may result in spillage, excessively strong vapors or a fire hazard.

  7. Insert the fragrance container with the label facing outward so it is visible through the caddy window (Diagram 1). The label contains important information.

  8. Always keep the container in the caddy while it is connected to the dispensing pump.

OPERATION

Powering Up the Pump
IMPORTANT NOTE: This step only needs to be performed during installation.

  1. The pump needs to be turned on before it can be used
  2. Press and hold the power button for 3 seconds. The LED will turn on solid red.
PUMP LED LIGHT: KEY:
Flashing Green LED Pump is OFF. Press and hold the power button for 3 seconds

to turn the pump on.
Solid Red| Pump is ON, but has not been activated. To activate the pump, tum your steam generator ON from the in-shower control and press the aroma button.
Solid Green LED| Pump is on and has been activated from the in-shower control.
The LED will turn off each time the pump injects fragrance into the steam line.

Adjusting the Amount of Fragrance Delivery
The Aroma Steam system has been factory set to deliver a suitable amount of fragrance into a typical sized steam room. Do not exceed the maximum setting. Please contact the Mr Steam Technical Service Department before changing this setting.
Contact the Mr Steam Technical Service Dept. at (800) 76-STEAM (East coast) or (800) 72-STEAM (West Coast) for assistance or additional information.
WARNING
Increasing the settings may introduce excessive concentration of fragrance into the steam room, resulting in a health hazard.

Activating the Pump from a Control
Air Tempo® Control

  1. Press the ON/OFF button to turn the steam generator ON.
  2. Press the AROMA button, AROMA will be displayed on the screen when Aroma Steam is on.
  3. Aroma fragrance will automatically be pumped into the steam line at preset intervals.

steam ® Control

  1. Press the START button to turn the steam generator on.
  2. In the dashboard press the AROMA button, the button will be highlighted when Aroma Steam Pump is on.
  3. Aroma fragrance will automatically be pumped into the steam line at preset intervals.

tempo Plus® Control

  1. Press the ON/OFF button to turn the steam generator ON.
  2. Press the AROMA button, AROMA will be displayed on the screen when Aroma Steam is on.
  3. Aroma fragrance will automatically be pumped into the steam line at preset intervals.

WARRANTY

To view or download the Mr Steam Aroma Steam System Warranty and register your product go to: blog.mrsteam.com/wr
Products, information and specifications are subject to change without notice.
For more information please call Sales & Support at
1.800.76.STEAM (East Coast) 1.800.72.STEAM (West Coast) www.mrsteam.com

hello@mrsteam.com
 www.mrsteam.com
PUR 100402 Rev 05.22
43-20 34th Street, Long Island City, NY 11101
9410 S. La Cienega Blvd. Inglewood CA 90301
1800 76 STEAM
Fax: 718 472 3256
1800 72 STEAM Fax: 310 216 2944

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals