Eliwell Controls HACCP Module Dongle BTLE 5.0 Air Instructions

June 6, 2024
Eliwell Controls

Eliwell LOGO

Controls HACCP Module Dongle BTLE 5.0 Air
Instructions

DANGER

  • HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH
    Disconnect all power from all equipment including connected devices, prior to removing any covers or doors, or installing or removing any accessories, hardware, cables, or wires.

  • Always use a properly rated voltage sensing device to confirm the power is off where and when indicated.

  • Before powering the device back up, fit back and fix all the covers, hardware components, and wiring.

  • Verify the earthing connections on all earthed devices.

Failure to follow these instructions will result in death or serious injury.
The Dongle BTLE 5.0 AIR is compatible with all Eliwell instruments which have the word AIR written in the description

DANGER

HAZARD OF ELECTRIC SHOCK AND FIRE

  • This device should only be used with Eliwell compatible instruments.
  • Fit the Dongle BTLE 5.0 AIR inside the refrigeration device, in an inaccessible position.

Failure to follow these instructions will result in death or serious injury.

Electrical equipment should be installed, operated, serviced, and maintained only by qualified personnel.
No responsibility is assumed by Schneider Electric and Eliwell for any consequences arising out of the use of this material.

WARNING

UNINTENDED EQUIPMENT OPERATION

  • Do not use this equipment in safety-critical machine functions.
  • Do not disassemble, repair, or modify this equipment.

CONNECTIONS

Eliwell Controls HACCP Module Dongle BTLE 5 0 Air -
CONNECTIONS

The ‘Eliwell AIR’ APP can be downloaded from the ‘APP store’ for the iOS operating system (version 10.0 or greater) or from the ‘Play store’ for the Android operating system (version 7.0 or greater).
For information regarding the cables to use with the BTLE 5.0 AIR Dongle, please contact your local Eliwell representative /Update the Eliwell AIR APP to the latest available version.

NOTICE

UNINTENDED EQUIPMENT OPERATION

  • Disconnect all the equipment before installing/dismantling cables or wires.
  • Position and adequately fix the device to prevent cable disconnection.
  • The TTL cable must be routed separately from the power cables.
  • Check the length of the TTL cable, referring to the datasheet for the compatible AIR controller.

Failure to follow these instructions can result in equipment damage.

NOTICE
UNINTENDED EQUIPMENT OPERATION DUE TO ELECTROSTATIC DISCHARGE OR DURING INSTALLATION

  • Keep the device in the protective packaging until ready for installation.
  • When handling sensitive equipment, use an earthed protective device against electrostatic discharge.
  • Before handling the device, always discharge the static electricity from the body by touching an earthed surface or type-approved antistatic mat.

Failure to follow these instructions can result in equipment damage.

DIMENSIONS

Eliwell Controls HACCP Module Dongle BTLE 5 0 Air -
DIMENSIONS

  1. TTL Connection towards instruments;
  2. Hole for accessing the Password reset button (see ‛Password reset procedure’).
  3. Operating LED;
  4. Fixing hole. Use screws with a nominal diameter of: 3.9…4.2 mm (0.15…0.17 in.).

CONFIGURING THE MODBUS CONNECTION

The serial parameters will be detected automatically by Dongle BTLE 5.0 AIR.
The valid Modbus communication parameters are listed in the table.
NOTE: Verify that the Modbus address of the device connected is equal to 1

9600/8E1 9600 8 E 1
BAUDRATE 19200

38400
57600|
RIT NIIMRFP| | 8 BIT (8 6wr)
PARITY BIT| | E = EVEN (YET) 0 = ODD (HEYET) N = NONE (HET)
STOP BIT| | 1 = 1 BIT (1 614T)
2 = 2 BIT (2 614TA)

PASSWORD RESET PROCEDURE

Eliwell Controls HACCP Module Dongle BTLE 5 0 Air - PASSWORD RESET
PROCEDURE

To reset the password of the DONGLE BTLE 5.0 AIR, proceed as follows:

  • Press the reset button using a blunt plastic object;
  • Press and hold the button until the LED is lit steadily (approx. 5 seconds)
  • The new password will assume the default value (000000, six zeros)

PAIRING

PAIRING USING ELIWELL AIR APP
Pair a new controller. Access this function in one of two ways:

  1. From the Home page, tap +
  2. From the menu, tap “Connect a new Device”

A list of available controllers not yet paired with the Eliwell AIR application will be displayed. To pair a controller:

  1. Select the controller (tap the name) from the list of available controllers

  2. Enter the Bluetooth pairing code in the window that appears.
    Note. “000000” is the factory-set default pairing code for the first access.

  3. Wait for the application to launch its preliminary tasks.

  4. The controller is now paired and will be shown on the home page.

Refer to the T_AIR_00IT TelevisAir APP&Cloud User Guide manual, available on the TelevisAir Cloud (Terms&Conditions web page) and at www.eliwell.com, for further information.

FIRMWARE UPDATE

NOTICE
INOPERABLE EQUIPMENT
Stay within range of the dongle (10 m) until the firmware update is complete.
Failure to follow these instructions can result in equipment damage.

TECHNICAL DATA

The product complies with the following harmonized standards IEC 62368-1
Intended use Bluetooth Modbus interface via TTL serial port
Purpose of controller Accessory for instruments to be incorporated into

category I or II machines
Pollution class| 2
Power supply| 3 … 5 Vdc (Bc)
Consumption| < 50 mW (не более 50 мВт)
Ambient operating conditions| Temperature: -20…65 °C (-4 … 149 °F) Humidity (non-condensing)
Transportation and storage conditions| Temperature: -25…50 °C (-13 … 122 °F) Humidity (non-condensing)
IP enclosure rating| IP20
Installation| with screw
Wireless technology| Bluetooth low energy 5.0
Operating frequency| 2402-2480 MHz
Maximum output power| 5 dBm
Maximum transmission range| 10 m – 32,808 ft (10 м – 32,808 ноги) in the absence of obstacles
Clock operating autonomy without power supply| Typical value: 24 hours
Type of buffer used by Datalogging system| Circular buffer (1)

(1)10’000 data entries can be logged. The circular buffer stores the 10’000 most recent data entries.
NOTE: The acquisition frequency set via APP determines the number of days for which data is logged on the device.
For example, with a data acquisition frequency of 1 minute, the device will log data for 7 days before overwriting the oldest data.
(1)È prevista la memorizzazione di 10.000 dati. Il buffer circolare conserva i 10.000 dati più recenti.

DATA DOWNLOAD

The duration of historical data recorded download from Dongle BTLE 5.0 AIR is proportional to data archive size.
Set properly the data acquisition time interval, including download.
NOTE: Other wireless active devices, in the measurement field, can affect the Bluetooth connection and data downloading time.

FCC USA and IC Canada Compliance Statement

This device complies with the following requirements:

  • FCC (Federal Communications Commission) – Part 15
  • ISED (Industry Canada) RSS-102 and RSS-247 and RSS-Gen

Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. This device must accept any interference received, including interference that may cause undesired operation of the device.

Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
The sensor is designed for use at least 200 mm (7.87 in.) away from the operator in normal operating conditions.
FCC ID: 2AMLEDONGLEBTLE5
IC: 9727A-DONGLEBTLE5

DISPOSAL
The equipment (or product) must be subjected to separate waste collection in compliance with the local legislation on waste disposal.

INFORMATION

Eliwell Controls s.r.l.
Via dell’Industria, 15 • Zona Industriale Paludi •
32016 Alpago (BL) ITALY
T: +39 0437 986 111
T: +39 0437 986 100 (Italy)
+39 0437 986 200 (other countries)
E: [email protected]
Technical helpline: +39 0437 986 300
E: [email protected]
www.eliwell.com
9IS64815.00
07 – 2021

Read User Manual Online (PDF format)

Loading......