ARROW PR-34063-HPSL Pressure Injectable Three-Lumen PICC with 130 cm Wire Instruction Manual

June 4, 2024
Arrow

ARROW PR-34063-HPSL Pressure Injectable Three-Lumen PICC with 130 cm Wire

ARROW PR-34063-HPSL Pressure Injectable Three-Lumen PICC with 130 cm Wire-
fig1

Contents:

  • 1: Three Lumen Catheter: 6 Fr. (2.14 mm OD) x 40 cm, Pressure Injectable, Blue FlexTip®
  • 1: Peel-Away Sheath: 6.5 Fr. x 4″ (10 cm) Radiopaque over 6.5 Fr. Dilator
  • 1: Spring-Wire Guide: .018″ (0.46 mm) dia. x 17-3/4″ (45 cm) (Straight Soft Tip on Both Ends)
  • 1: Spring-Wire Guide, Marked: .018″ (0.46 mm) dia. x 51-3/16″ (130 cm)(Straight Soft Tip on
  • One End – Straight Stiff Tip on Other)
  • 1: Introducer Needle: Echogenic 21 Ga. x 2-3/4″ (7 cm) TW
  • 1: Syringe: 5 mL Luer Lock
  • 1: Skin Protectant Prep
  • 3: Dust Cap: Non-Vented
  • 1: Second Site™ Adjustable Hub: Fastener
  • 1 : Second Site™ Adjustable Hub: Catheter Clamp
  • 1: Patient ID Card
  • 1: Chart Sticker
  • 1: Patient Information Booklet
  • 1: Checklist/CLIP Sheet
  • 1: Paper Tape Measure
  • 1: Dressing: STATLOCK®1 Catheter Stabilization Device
  • 1A registered trademark of C. R. Bard, Inc

Rx only

  • Warning: Read all package insert warnings, precautions, and instructions prior to use.
  • Failure to do so may result in severe patient injury or death.
  • California Prop. 65
  • ⚠ WARNING: Cancer and Reproductive Harm.
  • www.P65Warnings.ca.gov
  • Not made with natural rubber latex.
  • Fluid path components are non-pyrogenic.
  • Contraindications: The Pressure Injectable PICC is contraindicated wherever there is presence of device related infections or presence of previous or current thrombosis in the intended insertion vessel or catheter pathway. Clinical assessment of patient must be completed to ensure no contraindications exist

PRODUCT SPECIFICATION

 | ****

**Priming Volume***

| Gravity Flow

Rate†

| ****

Pump Flow Rate††

| MAX Pressure Injection

Flow Rate**

---|---|---|---|---
Lumen| (mL)| (mL/hr)| (mL/hr)| (mL/sec)
Distal (17 Ga.)| 0.55| 1370| 6800| 6
Medial (19 Ga.)| 0.44| 317| 2820| not rated
Proximal (19 Ga.)| 0.42| 317| 2920| not rated

  • Priming volumes are approximate and are done without accessories.
  • Flow rate values are approximate and are determined using deionized water at 100 cm head height.
  • Pump flow rates are determined at maximum pump pressure of 10 psig and represent approximate flow capabilities.
  • Pressure injection flow rates are determined at the injector pressure setting of 300 psi maximum using media of 11.8 centipoise viscosity, with 152 cm pressure tubing.

ABOUT COMOANY

Arrow International LLC Subsidiary of Teleflex Incorporated 3015 Carrington Mill Blvd. Morrisville, NC 27560 USA

WEBSITE:www.teleflex.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Arrow User Manuals

Related Manuals