Teejet 73 Series Addflow User Guide

June 11, 2024
TeeJet

Teejet 73 Series Addflow User Guide
Teejet 73 Series Addflow

CONNECTIONS TABLE

CONNECTIONS TABLE

Description Connection
Carrier Flow Meter Supply
Signal S2
Ground
Liquid Flow Sensor Supply (Brown)
Signal (Black) S4
Ground (Blue)
Master Signal (12V is spraying) Supply (Brown)
Signal (Black) S5

CONNECTIONS TABLE

Jumpers Position
J7 S1 R
J9 S4
J8 S5 if External masterS5R if always active

GENERALITIES

Function Key Description
1. Power On The unit will power on and show the first working screen. inj.

Rate2.00%

2. Power Off| | The unit will power off.
3. Selection of Working Screen| |

FUNCTIONALITY

Function Display Comments Possible Actions
1. Injection Dose Rate This is the desired dose rate for the injected
product. It is set as a percentage of the main carrier flow. to change dose

rateto select another display value
2. Injection Flow| | This is the actual flow of injected product.| to select another display value
3. Carrier Flow| | This is the actual main carrier flow.| to select another display value
4. Injected Volume| | This is the injected volume counter.| to select another display value
to clear the counter

PRIMING

To activate priming, push the Pump switch to CAL

PRIMING

The pump will then start running and the display will show pumped volume
Scren Display

When predefined volume has been injected, the display will go back to the previous working screen.

ALARMS

Function Display Comments Possible Actions
1. Pump Not Running ![Scren Display](https://manuals.plus/wp-
content/uploads/2023/05/Screenshot_19-16.jpg) Alarm message will appear when
injectionstarted but the pump is not turning. Check cabling and pump
2. No Liquid Injected ![Scren Display](https://manuals.plus/wp-
content/uploads/2023/05/Screenshot_20-15.jpg) This means that no liquid is

injected. Alarm message will appear only if the liquid presence sensor is mounted.| Check plumbing and//or fill the tank.

PROGRAM

Function Display Possible Actions Comments
Access/Exit Push  for 3 seconds Master must be off
1. Carrier Flow Meter ![Scren Display](https://manuals.plus/wp-
content/uploads/2023/05/Screenshot_21-16.jpg)  to select another step

to enter carrier flow meter calibration (1.1)
Push  for 3 seconds to escape program|
1.1| Scren Display| to modify value to validate value| Main carrier flow meter calibration in pulses/litre
2. Injection Pump| Scren Display| to select another step
to enter calibration (2.1)
Push  for 3 seconds to escape program|
2.1 Injection Pump Type2.2 Injection PumpCalibration| Scren
Display| to modify value
to validate value (2.2) to escape (2)
Push for 3 seconds to escape program| Choices are:

  • Peristaltic
  • Piston 1 (head)
  • Piston 2 (heads)
  • Piston 3 (heads)
  • Piston 4 (heads)

Scren Display| to modify valve
to validate value (2) to start automatic calibration
(see “7. Pump Automatic Calibration” on page 4)| This is the complete pump calibration (all heads together). Units are pulses/millilitre. Average value is 3.00 per head for a piston pump.
3. Prime Calibration| Scren Display|  to select another step
**** to enter calibration (3.1)
Push  for 3 seconds to escape program|
3.1| Scren Display| to modify value
to validate value
to start Automatic calibration(see “8. Prime Automatic Calibration” on page 4)| This is the volume that must bepumped to prime the system.

PUMP AUTOMATIC CALIBRATION

Function Display Possible Actions Comment
2.2 Injection Pump Calibration to modify value

to validate value (2)
to start Automatic calibration| This is the complete pump calibration (all heads together.) Units are pulses/millilitre. Average value is 3.00 per head for a piston pump.
2.2.1| | to exit Automatic calibration Push on the CAL switch on the pump to start the calibration. Collect the pumped volume. Keep the CAL switch pushed until calibration is finished.| Pump must be ready to inject (tubes filled).
2.2.2| | Display shows the counted pulses from the pump| Release the CAL switch when enough pulses have been counted.
2.2.3| | to set the pumped volume to validate| Release the CAL switch when enough pulses have been counted.

PRIME AUTOMATIC CALIBRATION

Function Display Possible Actions Comments
3.1 Prime Calibration to modify value

to validate value
to start Automatic calibration| This is the volume that must be pumped to prime the system.
3.1.1| | Push on the CAL switch on the pump to start the calibration. Keep the CAL switch pushed until calibration is finished.|
3.1.2| | Display will show injected volume. Release the CAL switch when system has been primed.
to validate|

www.teejet.com

98-05355-EN R1 English International
© TeeJet Technologies 2022

Teejet Logo

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

TeeJet User Manuals

Related Manuals