TeeJet TECHNOLOGIES 116950 Nozzle Body Shutoff Valves Instruction Manual

July 20, 2024
TeeJet TECHNOLOGIES

TeeJet TECHNOLOGIES 116950 Nozzle Body Shutoff Valves

Specifications

  • Product Name: TEEJET e-CHEMSAVER ES Solenoid
    Operated Electric Shutoff Valve

  • Manufacturer: Spraying Systems Co.

  • Connector: 2-Pin Superseal 1.5

  • Torque Specifications: 12 in-lbs (1.36 N-m)

  • Parts List Number: PL116950

Product Usage Instructions

Disassembly

  1. Unscrew the valve assembly from the nozzle body by rotating the interface cap/locking ring counterclockwise until the assembly separates.
  2. Remove the FKM gasket (Part Number: CP116247-VI-10X).
  3. Loosen and remove the nylon interface cap/locking ring (Part Number: 116961) from the coil assembly by compressing it against the coil assembly and turning counterclockwise.

Repair and Reassembly

  1. Ensure all repairable parts are accessible.
  2. Replace the installation spring (Part Number: CP116963-CE), plunger subassembly (Part Number: 116956), stainless steel spring (Part Number: CP116960-SS), and o-ring (Part Number: CP7717-M17X1.5-VI-10X) if needed without further disassembly.
  3. During reassembly, press down the o-ring onto the outside base of the threads on the coil assembly to avoid damage.
  4. Place the stainless steel spring and plunger sub-assembly in the coil assembly carefully as per instructions.
  5. Tighten the nylon interface cap/locking ring onto the coil assembly by turning clockwise until tight. Insert gasket into the interface cap and locking ring subassembly.

Torque Specifications

Tighten the interface cap/locking ring and coil assembly to 12 in-lbs (1.36 N-m).

FAQ

Q: What should I do if the valve is not opening?

A: Check the solenoid connection and ensure it is energized.
Verify that all parts are properly reassembled according to the instructions provided.

Q: How do I know if I need to replace the o-ring?

A: Inspect the o-ring for any signs of wear, cracking, or damage. If in doubt, it is recommended to replace it as part of regular maintenance.

Introduction

  • The 116950 e-ChemSaver® ES Valve is a solenoid-actuated shutoff compatible with a wide range of TeeJet® nozzle bodies equipped with a diaphragm check valve. It can be used for end-of-boom nozzles as well as individual tip shutoff control.
  • The valve is normally closed and opens when the solenoid is energized. The 116950 has a 2-Pin Superseal 1.5 connector molded into the body for a clean, weather-tight electrical connection.
  • Application Note(s): Rinse the system with clean water after each application. 80 mesh strainer screen or finer is recommended with all e-ChemSaver® ES Valve applications.

General Disassembly and Reassembly

  1. Unscrew the valve assembly from the nozzle body by rotating the interface cap/locking ring (Item counterclockwise until the assembly separates.

  2. Remove the FKM gasket (1).

  3. Loosen and remove the nylon interface cap/locking ring (2) from the coil assembly (3-7) by compressing the interface cap/locking ring against the coil assembly and turning counterclockwise until separated.

    • All repairable parts should be accessible at this point. The installation spring (3), plunger sub-assembly (4), stainless steel spring (5), and o-ring (6) can be replaced without further disassembly.
  4. During reassembly, please ensure that the o-ring (6) is pressed down to the outside base of the threads on the coil assembly(7/7A) to avoid damaging the o-ring when reassembling.

    • Then, place the stainless steel spring (5), and plunger sub-assembly (4) in the coil assembly (717A).
    • Note: The conical-shaped stainless steel spring (5) should be oriented with the wider end resting in the groove of the coil assembly (7/7A) and the narrower end facing outward (visible).
    • Then, place the plunger sub-assembly (4) with the black insert facing outward (visible) and insert it into the narrower end of the spring (5) when placed in the coil assembly (717A).
    • Then place the installation spring (3) onto the base of the coil assembly so that the three tabs lay flat on the base of the coil assembly.
  5. Tighten the nylon interface cap/locking ring (2) from the coil assembly (3-7) by compressing the interface cap/locking ring against the coil assembly and turning clockwise until tight.

    • Then place gasket (1) into interface cap and locking ring sub-assembly.
      Torque Specifications: Tighten interface cap/locking ring (2) & coil assembly (3-7) to 12 in-lbs (1.36 N-m)
  6. Recommended : At the time of installation, spray a sufficient quantity of corrosion prevention (CorrosionX® CorrosionX® Heavy Duty, or CorrosionX® Aviation) compound into the connector to wet the terminals before plugging the connector in.

PART DESCRIPTION

TeeJet-TECHNOLOGIES-116950-Nozzle-Body-Shutoff-Valves-
FIG-1

ITEM PART NUMBER DESCRIPTION
1 CP116247-VI-10X GASKET, FKM (10-PACK)
2 116961 INTERFACE
2A 116961-7 INTERFACE
3 CP116963-CE INSTALLATION SPRING, CELCON-BLACK
4 116956 PLUNGER SUB-ASSEMBLY
5 CP116960-SS SPRING, STAINLESS STEEL
6 CP7717-M17X1.5-VI-10X O-RING, FKM (10-PACK)
7 116951-12 COIL ASSEMBLY, 12V
7A 116951-24 COIL ASSEMBLY, 24V

SPARE KITS
AB116950-1-12-KIT, 12V COIL| KIT (INCLUDES ITEMS 6 AND| 7)|  |  |
AB116950-1-24-KIT, 24V COIL| KIT (INCLUDES ITEMS 6 AND| 7A)|  |  |
AB116950-2-KIT, SPARE PARTS KIT (INCLUDES ITEMS 4 AND 5)
AB116950-3-KIT, SPARE PARTS KIT (INCLUDES ITEMS 2 AND 3)
AB116950-4-KIT, SPARE PARTS KIT (INCLUDES ITEMS 2, 3, 4, 5, AND 6)

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals