QOLTEC 51942 Pure Sine Wave Monolith Charger User Manual
- June 11, 2024
- Qoltec
Table of Contents
QOLTEC 51942 Pure Sine Wave Monolith Charger
INTRODUCTION
Thank you for your trust and for choosing Monolith by Qoltec Pure Sine Wave Inverter/UPS Battery Charger. We are confident that the product will satisfy your expectations. This manual will guide you through the installation and use of the product includes important safety instructions for proper operation and installation. After reading this manual, don’t hesitate to get in touch with our Customer Service Department if you have any questions.
SAFETY INSTRUCTIONS
Warning! When installing and using the UPS uninterruptible reverse charging source, please read the safety instructions carefully.
-
In order to reduce the risk, please do not expose the UPS uninterruptible reverse charging source to harsh environments such as rainy days, snow and frost, fog, greasy and a lot of dust during installation, and do not install the UPS uninterrupted reverse charging source in a sealed place. , do not cover and block the vents, the UPS uninterruptible reverse charging source will be damaged by their relationship. to electric shock. Wires that do not meet the standard specifications may damage the UPS uninterrupted reverse charging source.
Because the UPS uninterruptible reverse charging source equipment itself contains components that are prone to arcing, it cannot be installed in a flammable and explosive environment during installation. -
When the battery is connected, if the acid substance of the battery comes into contact with the skin or clothes, please rinse immediately with clean water and soapy water. If the acid substance gets into the eyes, immediately wash the eyes with water for at least 20 minutes, and seek medical treatment immediately. .
-
Please do not put metal tools on the battery, it is very likely that the battery or the UPS uninterrupted reverse charging source electronic components will be damaged due to sparks caused by short circuit.
-
It is strictly forbidden to put small metal objects such as iron needles and iron pins into the product, away from the water source, to prevent the product from entering the water and damaging the UPS uninterrupted reverse charging source.
-
It is for bidden for children to operate this product, and do not touch the terminals, output
CHARGER WORKING PRINCIPLE/ UPS CONVERSION MODULE
-
Battery charging will work in 3 automatic stages
-
This series of products use the most advanced three-stage mode to charge the battery which are constant current, constant voltage and floating charge.
– In constant current charging stage, the charging current remains constant, charging capacity increased rapidly, battery voltage rises:
– In constant voltage charging stage, the charging voltage remains constant, charging capacity increase, battery voltage rises slowly, and the charging current decreases:
– The battery is fully charged, the charging current drops below the floating charge current, the charging voltage is reduced to the floating charging voltage;
– In the floating charging stage, the charging voltage will reduce and keep at the floating charging voltage, which can prevent battery from damage due to over charging. 12V charger: charging voltage 14.6V, floating charging voltage 13.BV. -
This product is suitable for dry batteries, aluminum brazing acid batteries, and lithium batteries to be customized.
-
In standby mode, AC power can charge battery when connect battery to DC terminal. Whenever the AC power trips or power off, the UPS uninterruptible power source will switch back to inverter mode automatically.
-
As long as the UPS uninterrupted power source is on, the disturbance to the equipment is minimal. It takes about 10 milliseconds to transit from standby mode to inverter mode. It also carried out at the same time to transit Inverter mode to the standby mode. UPS uninterrupted power source adopts the single-chip program technology design.
CHARGING MODE
PRODUCT FEATURES AND PRODUCT APPLICATIONS
- Pure Sine Wave
- High Efficiency, light in weight
- LED indicate the status of the load
- Cooling fan (control by temp.)
- Microprocessor design
- Load soft start, effectively maintain battery life
- Under voltage/overload/short circuit/over voltage/over temperature alarm
- Application
Power tools: chainsaws, drilling machines, grinders, electric sanders, punches, weeders, air compressors etc.
Office equipment: computers, printers, monitors, copiers, scanners etc.
Household appliances: vacuum cleaners, fans, fluorescent and incandescent lamps, electric cutters, sewing machines, etc.
Kitchen appliance: microwave oven, refrigerator, freezer, coffee machine, blender, ice maker, oven etc.
Industrial equipment: metal halide lamps, high pressure lamps, boat loading, solar energy, wind power generation etc.
Electronic field: TV, VCR, game console, radio, power amplifier, music equipment, monitoring equipment, terminal equipment, server, intelligent platform, satellite communication equipment etc.
CONDITIONS OF USE AND OPERATING INSTRUCTIONS
Operation guide:
Warning! Here is high pressure inside, please pay attention to safety.
Don’t disassemble or modify it without permission. Please operate according to
following guidelines, the company will not be responsible for the loss caused
by failure to follow this guide.
-
Battery selection: Use lead-acid battery with input voltage 12V/24V accordingly to fit product. For 12V/300W UPS uninterruptible power source, please select battery capacity above 30Ah. For 12V/1000W UPS uninterrupted power source, please select battery capacity above 1 OOAh, and so on.
-
When UPS uninterruptible power source connected to loads, please ensure that the loads power is within the rated power range, and cannot exceed the maximum power of the UPS uninterrupted power source when the switch is on.
-
Under-voltage protection: When the battery voltage is very low, the indicator will alarm, indicating that the DC supply voltage has dropped and the battery needs to be recharged. Example: For 12V inverter, input voltage is lower than 1 OV±0.5V. The AC output will turn off, the indicator turn red and alarm at the same time.
-
Over voltage protection: When the battery voltage is too high, the indicator will give an alarm, indicating that the DC supply voltage is too high, and the battery needs to be discharged as soon as possible. Example: For 12V inverter, input voltage reaches 15V±0.5V.
The AC output will turn off, the indicator turn red and alarm at the same time. -
Short-circuit protection: When inverter power supply is short-circuited, the output will turn off.
-
Reversely connected protection: When the battery is reversely connected, the fuse will blow to protect inverter.
-
Over temperature protection: When internal temperature exceeds about 75 degrees Celsius, the AC output will turn off, the indicator turn red and alarm at the same time. It won’t work until 15 minutes later.
INVERTER ICON AND CONNECTION
MODEL: 51940
PURE SINE WAVE INVERTER/UPS BATTERY CHARGER 600W (600/300)
MODEL: 51941
PURE SINE WAVE INVERTER/UPS BATTERY CHARGER 1200W (1200/600)
MODEL: 51942
PURE SINE WAVE INVERTER/UPS BATTERY CHARGER 2000W (2000/1000)
MODEL: 51943
PURE SINE WAVE INVERTER/UPS BATTERY CHARGER 4000W (4000/2000)
MODEL: 51944
PURE SINE WAVE INVERTER/UPS BATTERY CHARGER 5000W (5000/2500)
MODEL: 51945
PURE SINE WAVE INVERTER/UPS BATTERY CHARGER 6000W (6000/3000)
WIRING DIAGRAM
-
12V inverter connection
-
Output terminal connection method
COMMON FAULT AND ELIMINATING METHODS
Fault | Possible reason | Recommended solution |
---|---|---|
The inverter does not work during the initial power-up | Check the battery |
and wire connections. Check the DC fuse. Charge the battery.
The buzzer sounds and the red light flashes continuously far 1 second. Such
as: Bi… Bi… Bi…|
The voltage on the DC input terminal reaches the set point of the low battery alarm: 1 0.5+0.SVDC (12V version)
| 1.Check whether the battery power is sufficient, if it is lower than the previous worksheet. Please charge as soon as possible.
2.Check whether the battery wire is thick enough to carry the required current within the required length. If necessary, thicker wires can be used.
3. Tighten the connection of the battery input circuit.
The buzzer sounds and the red light flashes continuously for 2 times for 15. 5uchas:Toot..
Toot… Toot…
|
The voltage on the DC input terminal reaches the set point of overvoltage protection: 15.5+0.SVDC (1 2V version)
| 1. Check whether the voltage on the DC input terminal is greater than 15V /
30V / 60V DC.
Fault| Possible reason| Recommended solution
---|---|---
The buzzer sounds and the red light flashes continuously for 3 times for 15.
Such as: Toot toot.. Toot toot….
Toot toot.
| The system is overheatig| 1.1. Check whether the fan is working normally. Otherwise, the fan/fan control circuit may be faulty, please call technical support.
2.2. If the fan is working, please check whether the ventilation slots and vents on the suction side are on the vents. The air outlet of the fan cannot be blocked.
3.3. If the fan is working normally and the window is not blocked, please check if there is enough cold spare air. Also check whether the ambient temperature is below 45°C.
4.4. Reduce the load to reduce the heating effect.
After eliminating the cause of overheating and cooling, it will automatically reset.
The buzzer sounds and the red light flashes continuously Such as: Dudu dududududu…| This machine is overload protection| 1. Disconnect the load.
2. Reduce the load.
3. Whether the output is short-circuited.
Inverter working indicator is normal and no AC output| It may be damaged by transportation jitter. User connection error, etc.| 1. Check whether the device connection is normal.
2. Whether there is any abnormal noise inside the product.
3. Call technical support.
DATASHEET
Inverter output current form: Pure Sine Wave Inverter/UPS Battery Charger
Model | 51940 | 51941 | 51942 | 51943 | 51944 | 51945 |
---|---|---|---|---|---|---|
Rated power | 300W | 600W | 1000W | 2000W | 2500W |
3000W
Peak power| 600W| 1200W| 2000W| 4000W| 5000W|
6000W
Output rate| AC 230V±10%
DC input| 12V| 12V| 12V| 12V| 12V| 12V
Documents / Resources
|
QOLTEC 51942 Pure Sine Wave Monolith
Charger
[pdf] User Manual
51942 Pure Sine Wave Monolith Charger, 51942, Pure Sine Wave Monolith Charger,
Wave Monolith Charger, Monolith Charger
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>