Stewart FILMSCREEN STI-1 Wall Plate Instructions
- June 9, 2024
- Stewart FILMSCREEN
Table of Contents
Stewart FILMSCREEN STI-1 Wall Plate
Product Information
The STI-1 wall plate is a product manufactured by Stewart Film Screen Corporation. It is designed to replace the side plate on the Classic Model A electric screen. The wall plate comes with a wiring diagram for both the side plate and relay. It also has an optional 12V DC transformer that can be used to operate the screen by connecting it to a switch or AC outlet.
Product Usage Instructions
- Before replacing the side plate, make sure the electric screen’s power cord is unplugged or the circuit breaker has been shut off.
- Remove the existing side plate at the end of the screen.
- Disconnect the wire nuts.
- Refer to the STI-1 Side Plate wiring diagram for proper installation.
- Connect the wires as follows:
- Motor: Green wire is positive 12 volts (+), Sleeve is negative 12 volts (-).
- Neutral: White wire.
- Wire to projector or transformer: Red, black, and yellow wires.
- If using a transformer, connect it to a switch or AC outlet and switch the secondary or output of the transformer, NOT the 120V input of the transformer.
- Refer to the STI-1 Relay wiring diagram for proper installation.
- Connect the wires as follows:
- Motor: Green wire is positive 12 volts (+), Sleeve is negative 12 volts (-).
- Neutral: White wire.
- Wire to projector or transformer: Red, black, and yellow wires.
- If using a transformer, connect it to a switch or AC outlet and switch the secondary or output of the transformer, NOT the 120V input of the transformer.
STI Wall Plate for Classic Model A Work Instruction
STEWART FILMSCREEN CORPORATION
STI Wall Plate for Classic Model A Work Instruction
Document Identifier| Revision| Date Approved| Date Effective
QW-751| A| 1-12-22| 1-14-22
Responsibility and authority:
| Process Owner| Position / Title
Dino von Noy| | QA Manager
PURPOSE
Instructions to correctly replace the Side Plate on Classic Model A.
Scope
This procedure applies to properly replace Side Plate on Classic Model A
brand.
Definitions
None applicable
Definitions
None applicable.
Procedures
STI-1 Relay Replacement Instructions – Classic Model A Remove existing side plate / trigger relay
- Make sure the electric screen’s power cord is unplugged or the circuit breaker has been shut off.
- Remove the existing side plate at the end of the screen.
- Disconnect the wire nuts
Install new side plate trigger relay
- Use the diagrams below for proper wiring connections.
- Do not connect the incoming AC hot (black) to the motor black – it connects to “yellow”
- Secure wire connections with wire nuts.
- Reinstall the endplate and supply AC to the unit.
Trigger operational information
The STI-1 relay receives a 12 vdc trigger input signal to deploy the screen.
At that time the LED indicator will light up and remain lit while the screen
is “down”. When the trigger signal is terminated, the LED will go out and the
screen will retract. It is important to remember to allow the screen to fully
deploy or retract before switching directions of the trigger signal. Never
reverse a trigger signal when the motor is operational. Always allow the motor
to fully cycle and stop before sending or removing the trigger signal.
STI-1 Side Plate wiring diagram
- Optional 12 VOLT DC Transformer can be used to operate the screen by connecting it to a switch or a AC outlet. Red Black Yellow Green Neutral is White.
NOTE
If using a transformer, switch the secondary or Output of the transformer NOT the 120V Input of the transformer.
STI-1 Relay wiring diagram
Optional 12 VOLT DC Transformer can be used to operate the screen by connecting it to a switch or a AC outlet. Red Black Yellow Green Neutral is White Black.
NOTE
If using a transformer, switch the secondary or Output of the transformer NOT
the 120V Input of the transformer.
6.0 Quality Records
Record Name | Storage Location | Index Method | Retention |
---|---|---|---|
Work Instruction | Quality Assurance Dept | Order Number | 5 year min. |