Stewart FILMSCREEN QW-757 Virtual Cockpit Installation Guide
- June 9, 2024
- Stewart FILMSCREEN
Table of Contents
QW-757 Virtual Cockpit
Installation Guide STEWART FILMSCREEN CORPORATION
STEWART FILMSCREEN – Installing IMC
Document Identifier | Revision | Date Approved | Date Effective |
---|---|---|---|
QW-757 | A | 2/2/22 | 2/3/22 |
Responsibility and authority: | Process Owner | Position / Title | |
Dino von Noy | QA Manager |
PURPOSE:
To Safely and correctly Install IMC Low Voltage Screen Control
Scope:
This procedure applies to understanding the IMC.
Definitions:
120 VDC – 120 Volts Direct Current
Reference Documents, Disclaimer:
Attention: All electrical connections must conform to local and NEC codes. Stewart Filmscreen cannot be held liable for faulty or sub-standard wiring.
Procedures:
The IMC is a low voltage screen control that allows for switching conductors
to be run in Class II (small wire, exposed, no conduit) and will interface
with outboard video switching systems. The IMC has the capability of being
operated through a wall switch, infrared remote, radio frequency remote,
internet protocol (IP) control system, and a screen trigger through a
projector. For a detailed look at what the IMC has on board, please see page
2.
The IMC has the capability of being operated through a wall switch, infrared
remote, remote, internet protocol (IP) control system (requires optional
e-Node), Serial RS 232, (requires optional IBT-100) and a screen trigger
through a projector.
The IMC comes prewired from the factory to the motor and to the power cable.
For your reference, in the case of servicing, we broke down the pin layout for
the high voltage side of the connections Always have a qualified electrician
handle high voltage connections.
AC load side | IMC 100 | Motor Power Connections |
---|---|---|
BLACK | Pin 1 | AC Line + |
WHITE | Pin 2 | AC Neutral |
NC | Pin3 | Motor BLACK Line |
NC | Pin 4 | Motor Neutral |
GREEN | Pin 5 | Connect Ground to “Grounding” lug on IMC housing. Also connect |
ground wire from motor housingto same lug
IMC Control Board Schematic
LVC Contacts | IMC 100 | COMMANDS |
---|---|---|
COMMON | Pin 1 | COMMON |
CHANNEL 1 INPUT | Pin 2 | UP |
CHANNEL 2 INPUT | Pin 3 | DOWN |
SCREEN TRIGGER INPUT | Pin 4 | TRIGGER 3-15 VDC w/ COMMON |
IMC Wiring Diagram Luxus G2
IMC with e-Node 220V
www.stewartfilmscreen.com
1161 W. Sepulveda Blvd., Torrance CA 90502
USA l 800.762.4999
Tel: 310.784.5300
Fax: 310.326.6870
Email: request@stewartfilmscreen.com
©2019 Stewart Filmscreen.