AIRFLOW PCS – 72573603 12volt DC Pull Cord Module Instructions
- June 9, 2024
- AIRFLOW
Table of Contents
AIRFLOW PCS – 72573603 12volt DC Pull Cord Module Instructions
iCON SELV Fan Range Available Modules
Airflow iCON SELV 12V fans can be controlled by optional control modules. For
the SELV 12V range you can choose between six modules.
**Part no.*** | Model | Description | Wiring diagram |
---|---|---|---|
72573603 | PCS | Pull cord (Manual on/off) | A |
72574204 | PCTS | Pull cord timer (Pull cord, Run on | |
timer 1 – 30 min) | A, B | ||
72682307 | DTS | Delayed timer (Pull cord, 2 min delay, Run | |
on timer 2 – 45 min) | A, B | ||
72574202 | HTS | Humidity timer (Pull cord, Run on timer 1 – | |
30 min, 40 – 90% RH) | A, B | ||
72574203 | PRTS | PIR timer (Motion sensor, Run on timer 1– 30 | |
min, 40 – 90% RH) | A, B | ||
72574201 | PRHTS | PIR humidity timer (Motion sensor, Run on | |
timer 1 – 30 min, RH 40 – 90%) | A, B |
SAFETY FIRST: ALWAYS ISOLATE THE FAN UNIT FROM THE POWER SUPPLY BEFORE DOING ANY WORK ON THE FAN/MODULE.
Electrical installation
All electrical installation work to be carried out by an approved competent person in compliance with U.K. Building Regulations and to the latest IET standards, or the appropriate regulations in the country of installation. (for fan installation see the iCON SELV 12V Fan Range Installation and Operating Guide).
Diagram A – module wiring with no external switching (module
functionality / pull cord activation only):
Diagram B – module wiring with external switching (live trigger
connection used):
Mechanical installation
To install the module in an iCON fan follow the instructions below. for instructional drawings.
- Remove the iCON fan front cover .
- Lift the fan electrical terminal away from its mounting pillars and position on the module connector pins. Tighten the two screws with a suitable screwdriver. Ensure the leads are under the module retaining cable clamp.
- Fit the module at a slight angle into the fan housing, ensuring that the locating slot is fully engaged in to the locating block on the fan.
- Push the module against housing, ensuring the module clip holds it in place (clicks at the cable clamp). With iCON 15 & 30 the terminal will reposition back over mounting pillars.
Modules with pull cord: Ensure that the pull cord is properly located within the cord slot at the bottom of the fan.
Modules with PIR control: Remove the oval logo cap fitted at the bottom of the front cover of the fan. Replace it with translucent lens supplied with the PIR module. Note: The lens must be replaced in order for the PIR module to functionproperly. Ensure the orientation of the lens is correct (i.e. the lens should be flush with the surface).
Connecting mains cable into the module
Connect the 12V Power Supply Unit cable to the 3-way supply connector block
(see wiring diagrams on page 3) ensuring that the supplied cable clamp is
fitted. Refit the front cover.
Note: When using DTS module on initial connection the fan will start immediately and continue running for the duration set on the timer function of the module.
iCON module overview.
Front Cover Removal
To remove front cover assembly, first make sure the fan is off, isolated from the power supply and the iris shutter is fully closed
- Undo the locking screw at the bottom edge of the cover using a screwdriver.
- Rotate the cover a few degrees anticlockwise until it clicks out from the fittings.
- Remove the cover by pulling it out.
To refit the cover, reverse the above procedure. The iris shutter should be in closed position after refit. If not, wait approximately 1 min after fan switch off allowing the actuator to retract back in the closed position and then refit the cover again.
Module adjustment
A module with Timer and/or Humidistat is supplied pre-set, but may be adjusted by the installer. All adjustments must be done using the supplied Adjustment Tool.
Humidity settings
The humidistat is factory pre-set at approx. 70% RH (relativehumidity).
Adjusting the “% RH” towards 40% will result in fan activation at lower
humidity (more sensitive). Adjusting the “% RH” towards “90%” will result in
fan activation at higher humidity (less sensitive).
Time settings
The Run on Timer is factory pre-set at approx. 15 min. Adjusting the
“Timer”towards “MIN” will result in a timer overrun decrease towards 1 or 2
minutes (depends on module). Adjusting the “Timer” towards “MAX” will result
in a timer overrun increase towards 30 or 45 minutes (depends on module).
Adjustment tool
Humidistat
MIN = 40% RH
MAX = 90% RH
Timer
MIN = 1 or 2 min
MAX = 30 or 45 min
Warranty
Applicable to units installed and used in the United Kingdom.
Airflow Developments Ltd guarantees the iCON range for 3 years (incl. modules) from date of purchase against faulty material or workmanship. You can register your warranty on-line (for more information check at www.airflow.com)). Warranty only covers the product, not a reinstallation if required.
For detailed standard warranty terms and conditions see our website or contact Customer Service.
Disposal
Do not dispose of with household waste.
Please recycle where facilities exist.
Check with your local authority for recycling advice.
UK Head-Office
AIRFLOW DEVELOPMENTS Ltd Aidelle House, Lancaster Road Cressex Business Park
High Wycombe Buckinghamshire HP12 3QP United Kingdom
Tel: +44 (0) 1494 525252
Email: info@airflow.com
Web: www.airflow.com
Czech Republic
AIRFLOW LUFTTECHNIK GmbH o.s. Praha Hostýnská 520 108 00 Praha 10 Malešice
Czech Republic
Tel: +42 (0) 2 7477 2230
Email: info@airflow.cz
Web: www.airflow.cz
Germany
AIRFLOW LUFTTECHNIK GmbH Wolbersacker 16 53359 Rheinbach Germany
Tel: +49 (0) 222 69205 0
Email: info@airflow.de
Web: www.airflow.de
© Airflow Developments Ltd.
Airflow Developments Limited reserve the right, in the interests of continuous
development, to alter specifications without prior notice. All orders are
accepted subject to our conditions of sale which are available on request.
References
- Airflow Developments Group
- Home • AIRFLOW Lufttechnik GmbH – Ventilátory, Měřicí přístroje, Radiální ventilátory a ventilátory iCON
- Effizient, innovativ und umweltfreundlich - Airflow Lufttechnik GmbH
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>