VIKING VIJ5301 Insulated Jacket Instruction Manual

June 9, 2024
VIKING

Installation MANUALVIKING VIJ5301 Insulated
Jacket

VIJ5301 Insulated Jacket

Insulated Jacket
For Outdoor Products

VIJ5301 LIJ27
VIJ5361 LIJ30
VIJ5421 LIJ36
VIJ5541 LIJ42
VIJSB LIJ54
VIJPB LIJLSB2
LIJLPB

IMPORTANT: Before you build the frame, you must take into consideration the total weight of the liner, grill and any fi nishing materials.
Refer to the cutout dimension table for the proper framing dimensions for the insulation jacket. Determine the entry point for both the gas inlet and electrical connections. Make the 4” square holes for gas and electrical connections (rear or bottom access) based on your requirements.
Note: that the electrical connections are located on the left side and the gas connections are located on the right side.
A Carpenter’s “spirit level” should be used to assure that the framing is level, both front to back and side to side. Note: Never under any circumstance should you install the transformer or run a quick disconnect hose inbetween the grill and the inside of the insulating jacket.
Liner Installation
Position the liner into the frame. No part of the combustible enclosure can protrude above the top surface or in front of the face surface of the liner. Shim the liner if necessary.
Grill Installation
Use the proper equipment to support the grill. Place the grill into the liner and engage it over the liner lip across the back and sides. The liner is designed to support the grill without additional fasteners.
If desired any gap remainng between the liner and the combustible enclosure may be fi lled with a non-combustilble sealant or caulk.

Cutout Dimensions

Model A B C D E F
LIJ27 30″ 5″ 23 3/4″ 4 1/2″ 3″ 11 5/8″
(76.2 cm) (12.7 cm) (60.3 cm) (11.4 cm) (7.6 cm) (29.5 cm)
VI15301 / LI130 36″ 5″ 26’/2″ 4 1/2″ 3″ 11 5/8″
(91.4 cm) (12.7 cm) (67.3 cm) (11.4 cm) (7.6 cm) (29.5 cm)
VIJ5361 / LIJ36 42″ 5″ 23 3/4″ 4 1/2″ 3″ 11 5/8″
(106.7 cm) (12.7 cm) (60.3 cm) (11.4 cm) (7.6 cm) (29.5 cm)
VIJ5421 / LIJ42 48″ 5″ 26’/2″ 4’/2″ 3″ 11 5/8″
(121.9 cm) (12.7 cm) (67.3 cm) (11.4 cm) (7.6 cm) (29.5 cm)
VIJ5541 / LIJ54 60″ 5″ 26’/2″ 4 1/2″ 3″ 11 5/8″
(152.4 cm) (12.7 cm) (67.3 cm) (11.4 cm) (7.6 cm) (29.5 cm)
VIJSB / LIJLSB2 15’/2″ 3’/2″ 26’/2″ 4 3/4″ 3 1/8″ 11 5/8″
(39.4 cm) (8.9 cm) (67.3 cm) (12.1 cm) (8.0 cm) (29.5 cm)
VIJPB / LIJLPB 26’A” 5 3/8″ 23 7/8″ 4 3/4″ 3 1/8″ 11 5/8″
(68.0 cm) (13.7 cm) (62.7 cm) (12.1 cm) (8.0 cm) (29.5 cm)

VIKING VIJ5301 Insulated Jacket - fig WARNING
The regulator to be installed outside the insulating jacket. It can be positioned anywhere in the gas supply line between the grill and the shutoff valve.
Gas tubing should never be installed within the insulated jacket.

Insulated Jacket Dimensions

VIKING VIJ5301 Insulated Jacket - fig 1VIKING
VIJ5301 Insulated Jacket - fig 2VIKING
VIJ5301 Insulated Jacket - fig 4

Viking Range, LLC
111 Front Street
Greenwood, Mississippi 38930 USA
662-455-1200
For product information, call 1-888-(845-4641) or visit our web site atvikingrange.com
072267-000B (080122)