VOID Venu 210i V2 The Ultimate Choice User Guide
- June 9, 2024
- VOID
Table of Contents
Hear. Feel. Connect.
Venu 210i V2
The ultimate choice
USER GUIDE V2.2
Safety and Regulations
1.1 Important safety instructions
The lightning flash with an arrowhead symbol within an equilateral triangle is
intended to alert the user to the presence of uninsulated “dangerous voltage”
within the product’s enclosure that may be of sufficient magnitude to
constitute a risk of electric shock to persons.
The exclamation point within an equilateral triangle is intended to alert the
user of the presence of important operating and maintenance (servicing)
instructions in the literature accompanying the appliance.
Safety instructions – read this first
-
Read these instructions.
-
Keep these instructions.
-
Heed all warnings.
-
Follow all instructions.
-
Do not use this apparatus near water.
-
Clean only with a dry cloth.
-
Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
-
Do not install near any heat source such as radiators, heat registers, stoves, or other such apparatus that produce heat.
-
Do not defeat the safety purpose of the grounding-type plug. A grounding type plug has two blades and a third grounding prong.
The third prong is provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet. -
Protect power cords from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit the apparatus.
-
Only use attachments and accessories specified by Void Acoustics.
-
Only use with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.
-
Unplug the apparatus during lightning storms or when unused for long periods of time.
-
Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as when the power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
-
Since the mains power supply cord attachment plug is used to disconnect the device, the plug should always be easily accessible.
-
Void loudspeakers can produce sound levels capable of causing permanent hearing damage from prolonged exposure.
The higher the sound level, the less exposure needed to cause such damage. Avoid prolonged exposure to the high sound levels from the loudspeaker.
1.2 Limitations
This guide is provided to help familiarise the user with the loudspeaker
system and its accessories. It is not intended to provide comprehensive
electrical, fire, mechanical and noise training and is not a substitute for
industry-approved training. Nor does this guide absolve the user of their
obligation to comply with all relevant safety legislation and codes of
practice. While every care has been taken in creating this guide, safety is
userdependent and Void Acoustics Research Ltd cannot guarantee complete safety
whenever the system is rigged and operated.
1.3 EC declaration of conformity
For EC Declaration of Conformity please go to: www.voidacoustics.com/eu-
declaration-loudspeakers
1.4 UKCA marking
For details of the UKCA marking go to: www.voidacoustics.com/uk-declaration-
loudspeakers
1.5 Warranty statement
For warranty statement go to: https://voidacoustics.com/terms-conditions/
1.6 WEEE directive
If the time arises to throw away your product, please recycle all the
components possible.
This symbol indicates that when the end-user wishes to discard this product,
it must be sent to separate collection facilities for recovery and recycling.
By separating this product from other household-type waste, the volume of
waste sent to incinerators or land-fills will be reduced and natural resources
will thus be conserved.
The Waste Electrical and Electronic Equipment Directive (WEEE Directive) aims
to minimise the impact of electrical and electronic goods on the environment.
Void Acoustics Research Ltd complies with the Directive 2002/96/EC and
2003/108/EC of the European Parliament on waste electrical finance the cost of
treatment and recovery of electronic equipment (WEEE) in order to reduce the
amount of WEEE that is being disposed of in land-fill sites. All of our
products are marked with the WEEE symbol; this indicates that this product
must NOT be disposed of with other waste. Instead it is the user’s
responsibility to dispose of their waste electrical and electronic equipment
by handing it over to an approved reprocessor, or by returning it to Void
Acoustics Research Ltd for reprocessing. For more information about where you
can send your waste equipment for recycling, please contact Void Acoustics
Research Ltd or one of your local distributors.
Unpacking and Checking
All Void Acoustics products are carefully manufactured and thoroughly tested before being despatched. Your dealer will ensure that your Void products are in pristine condition before being forwarded to you but mistakes and accidents can happen.
Before signing for your delivery:
-
Inspect your shipment for any signs of contamination, abuse or transit damage as soon as you receive it
-
Check your Void Acoustics delivery fully against your order
-
If your shipment is incomplete or any of its contents are found to be damaged; inform the shipping company and inform your dealer.
When you are removing your Venu 210i V2 loudspeaker from its original packaging: -
Venu 210i V2 loudspeakers come double boxed and each box is stapled shut; take care when unboxing and removing the staples to avoid injury or damage to the loudspeaker
-
If you need to place the Venu loudspeaker on a flat surface ensure you use a lint free product to protect the finish
-
When you have removed the Venu 210i V2 loudspeaker from the packaging inspect it to ensure there is no damage and keep all original packaging in case it needs to be returned for any reason.
See section 1.5 for warranty conditions and see section 7 if your product needs servicing.
About
3.1 Welcome
Many thanks for purchasing this Void Acoustics Venu 210i V2 loudspeaker. We
truly appreciate your support. At Void, we design, manufacture and distribute
advanced professional audio systems for the installed and live sound market
sectors. Like all Void products, our highly skilled and experienced engineers
have successfully combined pioneering technologies with groundbreaking design
aesthetics, to bring you superior sound quality and visual innovation. In
buying this product, you are now part of the Void family and we hope using it
brings you years of satisfaction. This guide will help you both use this
product safely and ensure it performs to its full capability.
3.2 Venu 210i V2 overview
The Venu 210i V2 is a 1500 Watt, self-powered, double 10” reflex-loaded low
frequency enclosure capable of powering up to four mid-high enclosures from
its built-in 1500 W amplifier module.
Providing a frequency response of 40 Hz – 150 kHz ±3 dB and a continuous
output of 122 dB, peaking at 128 dB, it is ideal for filling venues with
noteworthy levels of bass.
speakON™ sockets are provided for quick and reliable connections and a
protected rear connector panel allows the enclosure to be placed against a
rear wall without damaging the audio or power connections.
The 210i V2 also features DSP for loudspeaker control and advanced signal
processing capabilities that can be accessed via the rear ethernet port. Add
to this the evocative Void sound from the new range of custom designed
components and it’s clear that Venu is the ultimate installation series.
3.3 Key features
- 3000 W Amp module (1500 W + 2 x 750 W)
- Capable of powering up to four mid high enclosures
- 2 x 10” low frequency drivers
- Built-in DSP
- Textured Warnex finish, optional custom colours
- Perforated steel grille
3.4 Venu 210i V2 specifications
Bass frequency range | 40 Hz – 150 Hz ± 3 dB |
---|---|
Input | 2 x 10 kf2 balanced |
Maximum output | 122 dB cont, 128 dB peak |
Driver configuration | 2 x 10″ LF |
Height | 334 mm (13.1″) |
Width | 676 mm (26.6″) |
Depth | 530 mm (20.9″) |
Weight | 33 kg (72.8 lbs) |
Enclosure | 15 mm birch plywood |
Finish | Textured Warnex |
Grille | Powder-coated perforated steel – foam filter |
Output | 2 x Neutrik speakONTM |
2-channel output mode
4 C2 / Ch (balanced)| 750 W
8 SI / Ch (balanced)| 400 W
Max output voltage| 78 Vneak
Max output current| 30 Aneak
Nominal power requirement| AC 100 V – 240 V, 50/60 Hz with PFC
Consumption
Standby| < 1 W
Idle| < 10.2 W
1/4 of max output power @ 4 Ω| 600 W
Amplifier and DSP features
DSP| Analogue Devices SigmaDSPTM^
S/N Ratio| 115 dB
Crosstalk separation| 85 dB @ 1kHz
Input sensitivity| 3 VRMS /11.7 dBu
Input impedance| 10 kf2 balanced
THD+N / DIM100| < 0.08% from 0.1 W to full power (typically <0.05%)
Slew rate| 50 V/ps @ 8 fl, input filter bypassed
Damping factor @ 8 (2| <10000 @ 100 Hz
Delay| 340 ms input delay, 10 ms per channel output delay
Input equalizer| 5 parametric equalizers: hi/lo-shelving, all-pass, band-pass,
band-stop, hi/ lo-stop
Output equalizer| Parametric IIR filters: peaking, hi/lo-shelving, all-pass,
band-pass, band-stop, hi/lo-pass
Crossover| Butterworth, Linkwitz-Riley, Bessel: 6 dB/oct to 48 dB/oct (IIR)
3.5 Venu 210i V2 dimensions
Cable and Wiring
4.1 Electrical safety
To avoid electrical hazards please note the following:
- Do not access the inside of any electrical equipment. Refer servicing to Voidapproved service agents.
4.2 Cable considerations for fixed installations
We recommend specifying installation-grade Low Smoke Zero Halogen (LSZH)
cables for permanent installations. The cables should use Oxygen Free Copper
(OFC) of grade C11000 or above. Cables for permanent installations should be
compliant with the following standards:
- IEC 60332.1 Fire retardancy of a single cable
- IEC 60332.3C Fire retardancy of bunched cables
- IEC 60754.1 Amount of Halogen Gas Emissions
- IEC 60754.2 Degree of acidity of released gases
- IEC 61034.2 Measurement of smoke density.
4.3 Venu 210i V2 wiring
4.4 Input connectors
Analogue input XLR-M pinout
Pin 1 | GND |
---|---|
Pin 2 | Hot + |
Pin 3 | Cold – |
Analogue input TRS Jack pinout
Tip | Hot + |
---|---|
Ring | Cold – |
Sleeve | GND |
4.5 Output connectors
Loudspeaker output Neutrik speakON™
Venu 210i V2 DSP
5.1 Components
1. Signal clipping LED
2. Signal presence/limiting LED
3. Status LED
4. Volume potentiometer
5. Preset LEDs
6. Preset select
7. Ethernet connector
8. Combi Jack – XLR input signal connector input B| 9. Combi Jack – XLR
input signal connector input A
10. Fan Inlet
11. Neutrik speakON™ output A
12. Neutrik speakON™ output B
13. PowerCon™ power input
14. Exhaust vents
---|---
5.2 Factory presets
Factory presets for the Venu 210i V2 are as follows:
5.3 Selecting your preset
To change your Venu 210i V2 preset:
1. Apply power to the amplifier
2. Wait 15 seconds for the amplifier to initialize
3. Press the preset button
4. The next selected preset light will begin flashing
5. When the preset LED stops flashing and becomes steady the amplifier is
ready to use in that preset mode.
For alternative loudspeaker presets, please download the relevant files from
the support documents tab found on www.voidacoustics.com/product-ranges/venu-
series/venu-210i-v2
5.4 LED chart
Clip/temp LED
Colour | Solid on | Action required |
---|---|---|
Off | Temperature OK, no clipping | No action required |
Yellow | High amplifier temperature | Reduce system gain |
Red | Output signal clipping | Reduce system gain |
Signal LED
Colour | Solid on | Action required |
---|---|---|
Green | Input signal present, output not in limit | No action required |
Yellow | Output limiter engaging | Reduce system gain |
Red | Input signal clipping | Reduce input gain |
Status LED
Colour | Solid ON |
---|---|
Off | System off |
Green | System ready to play, auto standby mode disabled |
Cyan | System ready to play, auto standby mode enabled |
Blue | System in standby mode: no signal detected in the last 15 minutes |
5.5 Power management
It is possible to implement a power saving strategy to reduce power
consumption and heat build-up. By factory default, the power management
feature is not active. Pressing and holding the Preset Select button for at
least 3 seconds will toggle the power management. When active (Cyan Status
LED), the Venu 210i V2 will enter a low power operating mode after 15 minutes
of no input signal (input level below -45 dBu). The DSP board will send a
signal to the amplifier module turning off the output stages and enabling
standby mode (Blue LED).
On detection of an input signal (input level above -45 dBu), the DSP board
will automatically re-engage the amplifier module and exit standby mode.
5.6 Software
-
Download and install Armonía Plus from the support page on the Void Acoustics website
-
Connect an ethernet cable from the Venu 210i V2 to the PC or router
-
Open Armonía Plus and click on the cog wheel in the bottom right corner of the window.
Ensure that the appropriate network interface is enabled under the Communication Manager tab -
Click on Match under the design tab, then Discovery. Armonía Plus should now be able to detect the device.
-
Click on the red Synchronisation button in the top right corner of the window. Turn Synchronisation on. You will now be able to add the device to the workspace and access the DSP. 5.7 Changing network setting
Once added to the workspace, double click on the Venu 210i V2 to access the processing options. The Network Settings section is available by clicking on the button under the Scheme window. Here you can view the current ethernet status and change address settings.In order to set a static IP, click on Change Address Settings, choose Static as Addressing Mode and enter the chosen IP address. Be aware that changing these settings could break communication with the Venu 210i V2. Confirm the changes by clicking on Apply Settings.
The new static IP will be applied immediately.
5.7.1 Network troubleshooting
The Venu 210i V2 cannot be discovered by Armonía Plus when it is set with a
different subnet than the network card to which it’s connected. In this case,
after you have clicked on Discovery, Armonía Plus will report that a connected
device has an incompatible IP address.
Hovering the mouse pointer above the alert message displayed at the bottom of
the Match window will show the current device IP address. In order to discover
the Venu 210i V2 you will need to adjust the settings of the PC network card
to be compatible with those of the product being connected to:
Go to Network Connection following this path: Control Panel \ Network and
Internet \ Network Connections
Right click on the network card you are using and click on Properties. In the
Networking tab, find the item Internet Protocol Version 4 (TCP/IPv4), select
it and click on Properties. This will allow you to set a static IP address for
the PC in the same range as the Venu 210i V2.
In Armonía Plus, re-enable the network card with the new IP settings in the Communication Manager and follow the connection steps in Section 5.6. Once added to the workspace, you can change its IP configuration as outlined in Section 5.7, then re-establish the PC network card with the previous settings.
5.8 Processing architecture
5.9 Internal signal path polarity
In order to increase the power’s supply energy storage efficiency, signals
coming from channel pairs 1-2 are polarity reversed, one with respect to the
other within the pair, when entering the amplifier. This ensures a symmetrical
use of the voltage rails: if, for example, both channels’ 1 and 2 input
signals are going through a peak at the same time, channel 1’s energy will
come from the positive voltage rails while channel 2, whose polarity is
reversed with respect to channel 1, will be fed energy from the negative
voltage rails. In this manner, the power supply will work symmetrically, with
one channel catered by the positive rails and the other by the symmetrical
negative rails. Channel 2’s signal will be polarity reversed once more to
ensure that both channels output with the same polarity as their corresponding
input signals.
For this reason it is very important not to invert the polarity of either
channels before feeding them to the module. A double polarity inversion (the
first by the user inserting the input signal and the other by the amplifier’s
internal circuitry) results in no inversion at all. If this were the case,
both channels would be weighing on only one side (positive or negative) of the
power supply’s voltage rails. This would result in an inefficient use of the
power supply’s energy.
Figure 5.10: Internal signal path polarity with example input
signal.
Both channels 1 and 2 are fed with the same sine signal.
Mounting
Part required:
Heavy Duty Top Hat – Black – IT2041
Heavy Duty Top Hat – White – IT2042
Step 1:
Remove all four M6 bolts and remove the cover plate.
Step 2:
Insert the Heavy Duty Top Hat and replace all four M6 bolts.
Service
Void Venu 210i V2 loudspeakers should only be serviced by a fully-trained
technician.
** No user serviceable parts inside. Refer servicing to your dealer.
7.1 Return authorisation**
Before returning your faulty product for repair, please remember to get an
R.A.N. (Return Authorisation Number) from the Void dealer who supplied the
system to you. Your dealer will handle the necessary paperwork and repair.
Failure to go through this return authorisation procedure could delay the
repair of your product.
Note that your dealer will need to see a copy of your sales receipt as proof
of purchase so please have this to hand when applying for return
authorisation.
7.2 Shipping and packing considerations
- When sending a Void Venu 210i V2 loudspeaker to an authorised service centre, please write a detailed description of the fault and list any other equipment used in conjunction with the faulty product.
- Accessories will not be required. Do not send the instruction manual, cables or any other hardware unless your dealer asks you to.
- Pack your unit in the original factory packaging if possible. Include a note of the fault description with the product. Do not send it separately.
- Ensure safe transportation of your unit to the authorised service centre.
Appendix
Architectural Specifications
The loudspeaker shall be active comprised of two high power 10” (254 mm)
direct radiating, reflex loaded low frequency (LF) transducers.
The enclosure shall be rectangular constructed from 15 mm multi-laminated
birch plywood with a wraparound grille and a rotating badge; it shall have a
removable cover plate for fixing an optional M20 top hat and it shall be
finished in a textured warnex with external dimensions of (H) 334 mm x (W) 676
mm x (D) 530 mm (13.2” x 26.6” x 20.9”) and weigh 33 kg (72.8 lbs).
Performance specifications of a typical production unit shall be as follows:
frequency response of 40 Hz – 150 Hz (±3 dB from rated sensitivity); pressure
sensitivity of 97 dB at one Watt 100 at one metre; rated nominal impedance of
4 Ω.
The system shall be powered by its own internal 1500 W dedicated power
amplification module with DSP management with two 750 W at 4 Ω full range
outputs.
The low frequency transducer shall be constructed on a cast aluminium frame
with a treated paper cone, 101.6 mm (4”) voice coil, wound with copper wire on
a high-quality voice coil former for high power handling and long-term
reliability.
The loudspeaker system shall be a Void Acoustics Venu 210i V2.
NORTH AMERICA
Void Acoustics North America
Call: +1 503 854 7134
Email: sales.usa@voidacoustics.com
HEAD OFFICE
Void Acoustics Research Ltd,
Unit 15, Dawkins Road Industrial Estate,
Poole, Dorset,
BH15 4JY
United Kingdom
Call: +44(0) 1202 666006
Email: info@voidacoustics.com
Hear. Feel. Connect.
voidacoustics.com
Void Acoustics Research Limited is a company registered in England and Wales
registration number 07533536
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>