COLTENE BRAVO G4 Chamber Autoclave User Guide

June 9, 2024
COLTENE

COLTENE Logo BRAVO G4 Chamber Autoclave
User Guide
Operator’s Manual (located on the USB key) should be consulted before using this autoclave.

BASIC OPERATION

  1. Power unit ON.COLTENE BRAVO G4 Chamber Autoclave - Power Unit On
  2. Fill with decriminalized/distilled water.COLTENE BRAVO G4 Chamber Autoclave - Distilled Water
  3. Load configurations.COLTENE BRAVO G4 Chamber Autoclave - Load Configuration
  4. Close unit door.
  5. Run cycle.COLTENE BRAVO G4 Chamber Autoclave - Run Cycle
  6. Open door.COLTENE BRAVO G4 Chamber Autoclave - Open Door
  7. Unload instruments.COLTENE BRAVO G4 Chamber Autoclave - Unload Instruments
  8. If required, drain manually.COLTENE BRAVO G4 Chamber Autoclave - Drain Manually

TOUCHSCREEN

COLTENE BRAVO G4 Chamber Autoclave - TOUCHSCREEN

VENTILATION

COLTENE BRAVO G4 Chamber Autoclave - VENTILATION

FILLING OPTIONS

COLTENE BRAVO G4 Chamber Autoclave - FILLING OPTIONS

DRAINING OPTIONS

COLTENE BRAVO G4 Chamber Autoclave - Draining Option

MAINTENANCE SCHEDULE

Daily| Clean the door gasket and internal part of the door with a clean wet cloth. Check for wear and replace if required.
---|---
Clean the door gasket and internal part of the door with a clean wet cloth. Check for wear and replace if required.
Weekly| Clean the chamber and appropriate accessories with a wet cloth. If required, use a neutral detergent (without alkalines and bleaches). Carefully rinse with decriminalized/distilled water and remove any residue.
Inspect and clean chamber anti-dust filter. Replace if necessary.
Ensure area around BRAVO G4 is dust free.
Monthly| Drain & clean the internal water reservoir as per the instructions outlined in the Operator’s Manual.
If applicable, clean the external water tank used for automatic filling.
Every 3 – 6 Months| Check the bacteriological filter and replace as required.
Lubricate the door lock. Using a clean cloth, remove any residues and lubricate the inside of the bushing with a film of the silicone-based grease provided.
Inspect and clean the chamber drain filter.
Replace if required. COLTENE BRAVO G4 Chamber Autoclave - Drain
Filter
Every Year or 1,000 Cycles| Replace the door gasket.

Spare Parts and Accessories

97400145 Door Gasket 17L/22L
97290160 Bacteriological Filter
97290210 Chamber Drain Filter
99951785 Chamber Rack 17L
99951786 Chamber Rack 22L
99950394 Pouch Rack
99951317 Tray 17L
99951318 Tray 22L
97467066 Tray Extractor

IMPORTANT!
Users of this device must be sure to select the most appropriate sterilization cycle according to the recommendations of the leading infection control authorities and local regulatory guidelines/recommendations.

COLTENE Logo 97055284-2
SD-622 NA EN R2. BRAVO is a trademark of SciCan Ltd. A Coltene Group Company.
Manufactured for SciCan Ltd. 1440 Don Mills Rd. T oronto, ON, M3B 3P9/Canada
CA +1 800-667-7733
US +1 800-221-3046
www.scican.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals