PRF315300HW Defrost Top Freezer Mini Refrigerator
BRAND: | Pjq¡¡u¡ Lqvqllp |
---|---|
MODEL: | PRF315300HW |
PRODUCT DESCRIPTION: | M¡µ¡ Bpj, glp33 3hqlvq3, cjy3Ępl cj¡3pqj, jqcq33qd |
hpµdlq
Coloj| White
LOADING QTY/4OHQ| 274
PRODUCT DIMENSION (WDH mm)| 48O5OO85O
PACKING DIMENSION (WDH mm)| 5OO54O885
PRODUCT WEIGHT (Kg):| Gjo33 Wq¡ghĘ (G.W)| NqĘ Wq¡ghĘ (N.W)
26| 24
ToĘpl Gjo33 Cpppc¡Ęy (Cu.FĘ)| 87
ToĘpl NqĘ Cpppc¡Ęy (Cu.FĘ)| 85
The cooling system
General exploded view
No. | stoma Code | Description of Spare Part | Quantity |
---|---|---|---|
4 | 20122080036 | Door hinge screw cover | 1 |
5 | 20122080091 | Door hinge cover | 1 |
6 | 3031400148 | Upper door hinge | 1 |
7 | 2208101188 | Middle hinge washer | 1 |
8 | 3031400116 | Middle door hinge | 1 |
9 | 3031400067 | Lower door hinge | 1 |
10 | 2100152587 | Upper door | 1 |
10.1 | 30204430145 | Upper door gasket | 1 |
10.2 | 20122090005 | Right Aid Closer Of Upper Door | 1 |
10.3 | 20122090011 | Left Aid Closer Of Upper Door | 1 |
11 | 2100152588 | Lower door | 1 |
11.1 | 3020400146 | Lower door gasket | 1 |
11.2 | 3031500031 | Door joist, straight | 1 |
11.3 | 3031500044 | Door joist, curved | 1 |
11.4 | 3031500011 | Lower door joist | 1 |
11.5 | 20122090162 | Right Aid Closer Of Lowe Door | 1 |
12.6 | 20122090179 | LeftAid CloserOf Lower Door | 1 |
12 | 2501100002 | Door switch | 1 |
13 | 20120020226 | Ridge shelf assembly | 1 |
17 | 3031500055 | Botde rack for drinks | 1 |
18 | 3020500092 | Upper door joist | 1 |
19 | 2207400523 | Crisper drawer assembly | 1 |
20 | 20120030010 | Cover of crisper drawer | 1 |
21 | 3050100117 | Power supply cord | 1 |
22 | 3039900264 | Compressor bracket | 1 |
25 | 20122990039 | Drain pan | 1 |
26 | 3050200095 | Earthing wire of compressor | 1 |
28 | 2400100282 | Compressor | 1 |
29 | 3040500011 | Drier filter | 1 |
30 | 20114070006 | Connecting tube | 1 |
31 | 3040600005 | Process tube | 1 |
32 | 20120010085 | Thermostat controller | 1 |
32. | 2400200005 | Thermostat | 1 |
32. | 20122010037 | Thermostat Knob | 1 |
32. | 2500500002 | Light Bulb | 1 |
33. | 20122010002 | Controller Shell | 1 |
33. | 20122010048 | Lamp Cover | 1 |
33. | 2500600001 | Light Holder | 1 |
42 | 20122990019 | Higher Leveling Foot | 1 |
--- | --- | --- | --- |
44 | 20122990006 | Shorter Leveling Foot | 1 |
300 | 2700501337 | Trademark | 1 |
301 | 2700117929 | Carton | 1 |
Trouble shooting guide
No | Problem | Possible Cause | What To Do |
---|---|---|---|
1 | Refrigerator room temperature Ok and compressor running Fan not working |
Freezer room temperature not enough cold
No air in the freezer air outlets| the fan motor failure| I- Open the cover
board of the air duct in the freezer room and check the fan
2-If not running. measure the voltage between the red wire and black wire of
fan
3-If the voltage is 12V, the fan motor is failure and replace it with a new
one
the failure of the inner wire to fan connector| 1-Measure Me voltage between
the CN2 red and black wire of PCB
2-If the voltage is 12v. check from the inner wire to fan connector
the PCB failure| 1-Measure the voltage between the CN2 red and black wire of
PCB
2-If the voltage is zero. then the PCB failure and change a new PCB
.)
2| No defrost
Freezer room temperature* not cold enough
Refrigerator room- duct and ice formation on the evaporator| the drainpipe
contains impurity| 1-Disconnect power, and let the ice melt and
drain pipe the
2-2 If not. check if there is impurity and dean
the drain pipe
the sensor failure a PCB failure| 1-Check the fuse
2-If the fuse is melted, it means that the sensor failure or PCB failure
3-Change the sensor or PC
the defrost heater is broken or PCB failure| 1-Check the CN4 defrost heater
two oonnector
2-If the heater is OK then is the PCB failure and change the PCB
3| The temperature of the freezer and refrigerator is not cold enough
The temperature can not be adjusted by the potentiometer (thermostat)| the
potentiometer failure| 1-Inspect the potentiometer (thamoStan
2-Measure the resistance value by adjusting the potentiometer (thermostat)
3-The resistance value is not changed by adjusting the potentiometer
(thermostat)
the sensor failure| 1-If the potentiometer (thermostat) setting is below 3
degrees. the compressor will be running 20 minutes and then stop 30 minutes
2-If the potentiometer (thermostat) setting is more than 3 degrees. the
compressor will be running 30 minutes and then stop 20 minutes
3-If the compressor works like the above situation. it means the sensor
failure
4-Open the back of the refrigerator and change the sensor of the refrigerator
evaporate
4| LED light is not worlung| the led failure| 1-Open the refrigerator door and
measure the voltage of CN3 in the PCB
2-If dae voltage is zero then it means the connecting wire failure
3-If the voltage is 12V. it means the led failure
---|---|---|---
the switch circuit failure| 1-If the CN3 voltage is not 12V. then check the
CN4 voltage
2-If the CN4 voltage is not changed by clovng and opening the door. it means
the switch circuit failure
s| Compressor not start running| no problem| 1-The time between two starting
is shorter than 12min
2-The refrigerator room temperature is lower than the set temperature
3-In this case. it is no problem. Please wait for longer
PCB failure| PCB has automatic self-examination
1-Open the cover of PCB at the back Of the product. plug-in power and Puth the
$W101. switch 3 seconds and the PCB begin
automatic self-examination program
2-Then the led. compressor. fan and defrost heater will work for two seconds
and then stop and quit the automatic self-examination program. After that. the
program will reset to the original setting
3-If the automatic self-examinant:0 program is not working. it means the PCB
failure and needed to be changed
compressor wire failure or compressor damage| 1-Measure the voltage of
compressor input connector
2-If it is OK then check the starting and relay of the compressor
3-Also check the wire if it Es OK
6| Not woeldng at all| the PCB failure| 1-Check the power by multimeter
2-If Me input voltage is 220V-240V. but the led. COmPressor fan. and defrost
heater are all not working. it means the PCB failure and needed to be changed