PREMIUM LEVELLA PRF315300HW Defrost Top Freezer Mini Refrigerator Instruction Manual

June 9, 2024
PREMIUM LEVELLA

PRF315300HW Defrost Top Freezer Mini Refrigerator
Instruction ManualPREMIUM LEVELLA logo Service manual
Model: PRF315300HW

PRF315300HW Defrost Top Freezer Mini Refrigerator

BRAND: Pjq¡¡u¡ Lqvqllp
MODEL: PRF315300HW
PRODUCT DESCRIPTION: M¡µ¡ Bpj, glp33 3hqlvq3, cjy3Ępl cj¡3pqj, jqcq33qd

hpµdlq
Coloj| White
LOADING QTY/4OHQ| 274
PRODUCT DIMENSION (WDH mm)| 48O5OO85O
PACKING DIMENSION (WDH mm)| 5OO54O885
PRODUCT WEIGHT (Kg):| Gjo33 Wq¡ghĘ (G.W)| NqĘ Wq¡ghĘ (N.W)
26| 24
ToĘpl Gjo33 Cpppc¡Ęy (Cu.FĘ)| 87
ToĘpl NqĘ Cpppc¡Ęy (Cu.FĘ)| 85

The cooling system

PREMIUM LEVELLA PRF315300HW Defrost Top Freezer Mini Refrigerator - cooling
system

General exploded view

PREMIUM LEVELLA PRF315300HW Defrost Top Freezer Mini Refrigerator - exploded
view

No. stoma Code Description of Spare Part Quantity
4 20122080036 Door hinge screw cover 1
5 20122080091 Door hinge cover 1
6 3031400148 Upper door hinge 1
7 2208101188 Middle hinge washer 1
8 3031400116 Middle door hinge 1
9 3031400067 Lower door hinge 1
10 2100152587 Upper door 1
10.1 30204430145 Upper door gasket 1
10.2 20122090005 Right Aid Closer Of Upper Door 1
10.3 20122090011 Left Aid Closer Of Upper Door 1
11 2100152588 Lower door 1
11.1 3020400146 Lower door gasket 1
11.2 3031500031 Door joist, straight 1
11.3 3031500044 Door joist, curved 1
11.4 3031500011 Lower door joist 1
11.5 20122090162 Right Aid Closer Of Lowe Door 1
12.6 20122090179 LeftAid CloserOf Lower Door 1
12 2501100002 Door switch 1
13 20120020226 Ridge shelf assembly 1
17 3031500055 Botde rack for drinks 1
18 3020500092 Upper door joist 1
19 2207400523 Crisper drawer assembly 1
20 20120030010 Cover of crisper drawer 1
21 3050100117 Power supply cord 1
22 3039900264 Compressor bracket 1
25 20122990039 Drain pan 1
26 3050200095 Earthing wire of compressor 1
28 2400100282 Compressor 1
29 3040500011 Drier filter 1
30 20114070006 Connecting tube 1
31 3040600005 Process tube 1
32 20120010085 Thermostat controller 1
32. 2400200005 Thermostat 1
32. 20122010037 Thermostat Knob 1
32. 2500500002 Light Bulb 1
33. 20122010002 Controller Shell 1
33. 20122010048 Lamp Cover 1
33. 2500600001 Light Holder 1
42 20122990019 Higher Leveling Foot 1
--- --- --- ---
44 20122990006 Shorter Leveling Foot 1
300 2700501337 Trademark 1
301 2700117929 Carton 1

Trouble shooting guide

No Problem Possible Cause What To Do
1 Refrigerator room temperature Ok and compressor running Fan not working

Freezer room temperature not enough cold
No air in the freezer air outlets| the fan motor failure| I- Open the cover board of the air duct in the freezer room and check the fan
2-If not running. measure the voltage between the red wire and black wire of fan
3-If the voltage is 12V, the fan motor is failure and replace it with a new one
the failure of the inner wire to fan connector| 1-Measure Me voltage between the CN2 red and black wire of PCB
2-If the voltage is 12v. check from the inner wire to fan connector
the PCB failure| 1-Measure the voltage between the CN2 red and black wire of PCB
2-If the voltage is zero. then the PCB failure and change a new PCB
.)
2| No defrost
Freezer room temperature* not cold enough
Refrigerator room- duct and ice formation on the evaporator| the drainpipe contains impurity| 1-Disconnect power, and let the ice melt and
drain pipe the
2-2 If not. check if there is impurity and dean
the drain pipe
the sensor failure a PCB failure| 1-Check the fuse
2-If the fuse is melted, it means that the sensor failure or PCB failure
3-Change the sensor or PC
the defrost heater is broken or PCB failure| 1-Check the CN4 defrost heater two oonnector
2-If the heater is OK then is the PCB failure and change the PCB
3| The temperature of the freezer and refrigerator is not cold enough
The temperature can not be adjusted by the potentiometer (thermostat)| the potentiometer failure| 1-Inspect the potentiometer (thamoStan
2-Measure the resistance value by adjusting the potentiometer (thermostat)
3-The resistance value is not changed by adjusting the potentiometer (thermostat)
the sensor failure| 1-If the potentiometer (thermostat) setting is below 3 degrees. the compressor will be  running 20 minutes and then stop 30 minutes
2-If the potentiometer (thermostat) setting is more than 3 degrees. the compressor will be running 30 minutes and then stop 20 minutes
3-If the compressor works like the above situation. it means the sensor failure
4-Open the back of the refrigerator and change the sensor of the refrigerator evaporate
4| LED light is not worlung| the led failure| 1-Open the refrigerator door and measure the voltage of CN3 in the PCB
2-If dae voltage is zero then it means the connecting wire failure
3-If the voltage is 12V. it means the led failure
---|---|---|---
the switch circuit failure| 1-If the CN3 voltage is not 12V. then check the CN4 voltage
2-If the CN4 voltage is not changed by clovng and opening the door. it means the switch circuit failure
s| Compressor not start running| no problem| 1-The time between two starting is shorter than 12min
2-The refrigerator room temperature is lower than the set temperature
3-In this case. it is no problem. Please wait for longer
PCB failure| PCB has automatic self-examination
1-Open the cover of PCB at the back Of the product. plug-in power and Puth the $W101. switch 3 seconds and the PCB begin
automatic self-examination program
2-Then the led. compressor. fan and defrost heater will work for two seconds and then stop and quit the automatic self-examination program. After that. the program will reset to the original setting
3-If the automatic self-examinant:0 program is not working. it means the PCB failure and needed to be changed
compressor wire failure or compressor damage| 1-Measure the voltage of compressor input connector
2-If it is OK then check the starting and relay of the compressor
3-Also check the wire if it Es OK
6| Not woeldng at all| the PCB failure| 1-Check the power by multimeter
2-If Me input voltage is 220V-240V. but the led. COmPressor fan. and defrost heater are all not working. it means the PCB failure and needed to be changed

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

PREMIUM LEVELLA User Manuals

Related Manuals