PREMIUM LEVELLA PRF315300HW Defrost Top Freezer Mini Refrigerator Instruction Manual

June 9, 2024
PREMIUM LEVELLA

PRF315300HW Defrost Top Freezer Mini Refrigerator
Instruction ManualPREMIUM LEVELLA logo Service manual
Model: PRF315300HW

PRF315300HW Defrost Top Freezer Mini Refrigerator

BRAND: Pjq¡¡u¡ Lqvqllp
MODEL: PRF315300HW
PRODUCT DESCRIPTION: M¡µ¡ Bpj, glp33 3hqlvq3, cjy3Ępl cj¡3pqj, jqcq33qd

hpµdlq
Coloj| White
LOADING QTY/4OHQ| 274
PRODUCT DIMENSION (WDH mm)| 48O5OO85O
PACKING DIMENSION (WDH mm)| 5OO54O885
PRODUCT WEIGHT (Kg):| Gjo33 Wq¡ghĘ (G.W)| NqĘ Wq¡ghĘ (N.W)
26| 24
ToĘpl Gjo33 Cpppc¡Ęy (Cu.FĘ)| 87
ToĘpl NqĘ Cpppc¡Ęy (Cu.FĘ)| 85

The cooling system

PREMIUM LEVELLA PRF315300HW Defrost Top Freezer Mini Refrigerator - cooling
system

General exploded view

PREMIUM LEVELLA PRF315300HW Defrost Top Freezer Mini Refrigerator - exploded
view

No. stoma Code Description of Spare Part Quantity
4 20122080036 Door hinge screw cover 1
5 20122080091 Door hinge cover 1
6 3031400148 Upper door hinge 1
7 2208101188 Middle hinge washer 1
8 3031400116 Middle door hinge 1
9 3031400067 Lower door hinge 1
10 2100152587 Upper door 1
10.1 30204430145 Upper door gasket 1
10.2 20122090005 Right Aid Closer Of Upper Door 1
10.3 20122090011 Left Aid Closer Of Upper Door 1
11 2100152588 Lower door 1
11.1 3020400146 Lower door gasket 1
11.2 3031500031 Door joist, straight 1
11.3 3031500044 Door joist, curved 1
11.4 3031500011 Lower door joist 1
11.5 20122090162 Right Aid Closer Of Lowe Door 1
12.6 20122090179 LeftAid CloserOf Lower Door 1
12 2501100002 Door switch 1
13 20120020226 Ridge shelf assembly 1
17 3031500055 Botde rack for drinks 1
18 3020500092 Upper door joist 1
19 2207400523 Crisper drawer assembly 1
20 20120030010 Cover of crisper drawer 1
21 3050100117 Power supply cord 1
22 3039900264 Compressor bracket 1
25 20122990039 Drain pan 1
26 3050200095 Earthing wire of compressor 1
28 2400100282 Compressor 1
29 3040500011 Drier filter 1
30 20114070006 Connecting tube 1
31 3040600005 Process tube 1
32 20120010085 Thermostat controller 1
32. 2400200005 Thermostat 1
32. 20122010037 Thermostat Knob 1
32. 2500500002 Light Bulb 1
33. 20122010002 Controller Shell 1
33. 20122010048 Lamp Cover 1
33. 2500600001 Light Holder 1
42 20122990019 Higher Leveling Foot 1
--- --- --- ---
44 20122990006 Shorter Leveling Foot 1
300 2700501337 Trademark 1
301 2700117929 Carton 1

Trouble shooting guide

No Problem Possible Cause What To Do
1 Refrigerator room temperature Ok and compressor running Fan not working

Freezer room temperature not enough cold
No air in the freezer air outlets| the fan motor failure| I- Open the cover board of the air duct in the freezer room and check the fan
2-If not running. measure the voltage between the red wire and black wire of fan
3-If the voltage is 12V, the fan motor is failure and replace it with a new one
the failure of the inner wire to fan connector| 1-Measure Me voltage between the CN2 red and black wire of PCB
2-If the voltage is 12v. check from the inner wire to fan connector
the PCB failure| 1-Measure the voltage between the CN2 red and black wire of PCB
2-If the voltage is zero. then the PCB failure and change a new PCB
.)
2| No defrost
Freezer room temperature* not cold enough
Refrigerator room- duct and ice formation on the evaporator| the drainpipe contains impurity| 1-Disconnect power, and let the ice melt and
drain pipe the
2-2 If not. check if there is impurity and dean
the drain pipe
the sensor failure a PCB failure| 1-Check the fuse
2-If the fuse is melted, it means that the sensor failure or PCB failure
3-Change the sensor or PC
the defrost heater is broken or PCB failure| 1-Check the CN4 defrost heater two oonnector
2-If the heater is OK then is the PCB failure and change the PCB
3| The temperature of the freezer and refrigerator is not cold enough
The temperature can not be adjusted by the potentiometer (thermostat)| the potentiometer failure| 1-Inspect the potentiometer (thamoStan
2-Measure the resistance value by adjusting the potentiometer (thermostat)
3-The resistance value is not changed by adjusting the potentiometer (thermostat)
the sensor failure| 1-If the potentiometer (thermostat) setting is below 3 degrees. the compressor will be  running 20 minutes and then stop 30 minutes
2-If the potentiometer (thermostat) setting is more than 3 degrees. the compressor will be running 30 minutes and then stop 20 minutes
3-If the compressor works like the above situation. it means the sensor failure
4-Open the back of the refrigerator and change the sensor of the refrigerator evaporate
4| LED light is not worlung| the led failure| 1-Open the refrigerator door and measure the voltage of CN3 in the PCB
2-If dae voltage is zero then it means the connecting wire failure
3-If the voltage is 12V. it means the led failure
---|---|---|---
the switch circuit failure| 1-If the CN3 voltage is not 12V. then check the CN4 voltage
2-If the CN4 voltage is not changed by clovng and opening the door. it means the switch circuit failure
s| Compressor not start running| no problem| 1-The time between two starting is shorter than 12min
2-The refrigerator room temperature is lower than the set temperature
3-In this case. it is no problem. Please wait for longer
PCB failure| PCB has automatic self-examination
1-Open the cover of PCB at the back Of the product. plug-in power and Puth the $W101. switch 3 seconds and the PCB begin
automatic self-examination program
2-Then the led. compressor. fan and defrost heater will work for two seconds and then stop and quit the automatic self-examination program. After that. the program will reset to the original setting
3-If the automatic self-examinant:0 program is not working. it means the PCB failure and needed to be changed
compressor wire failure or compressor damage| 1-Measure the voltage of compressor input connector
2-If it is OK then check the starting and relay of the compressor
3-Also check the wire if it Es OK
6| Not woeldng at all| the PCB failure| 1-Check the power by multimeter
2-If Me input voltage is 220V-240V. but the led. COmPressor fan. and defrost heater are all not working. it means the PCB failure and needed to be changed