NICOR TGL114U35 TGLS Select LED Backlit Troffer Instruction Manual
- June 9, 2024
- NICOR
Table of Contents
NICOR TGL114U35 TGLS Select LED Backlit Troffer
Product Information
The TGL and TGLS LED Troffer is a commercial lighting fixture that provides a bright and energy-efficient lighting solution. It is available in various models including TGL114U35, TGL114U40, TGL114U50, TGL122U35, TGL122U40, TGL122U50, TGL124U35, TGL124U40, TGL124U50, TGLS114U, TGLS122U, and TGLS124U. The fixture is designed to be installed in a t-grid ceiling and comes with four mounting/grid-tie clips for secure installation. It also features line voltage and 0-10V wiring options for easy connectivity.
Product Usage Instructions
- Before installation, read all the warnings and instructions included with and on the fixture box and all fixture labels to reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards. Commercial installation, service and maintenance of luminaires should be performed by a qualified licensed electrician.
- Make sure that the product is not damaged before installation.
- Unpack the fixture from its packaging and inspect it for defects due to shipping.
- Remove the ceiling panel and place the fixture into the t-grid ceiling.
- Bend four mounting/grid-tie clips up and out from the fixture. Secure safety cables through holes as required by local seismic requirements.
- Remove the j-box cover by removing the screw. Carefully remove knockouts for line voltage and 0-10V control wires.
- Connect wiring to the j-box with appropriate fittings. Line voltage and 0-10V wiring must be connected in separate knockouts.
- Connect wiring as shown. Pink and purple wiring are for 0-10V dimming systems. Cap off if not used.
- Reattach the cover of the junction box and secure it with a screw.
- For TGLS models, use the selector switch to set the desired CCT. Power on the fixture and test for proper function.
Note : This LED Troffer requires very few tools for installation. A drill or a screwdriver and a pair of wire cutters are needed. Also, for TGLS models, reference kit installation instructions for more information on SK14M10WH, SK22M10WH, or SK24M10WH.
Models : TGL114U35, TGL114U40, TGL114U50, TGL122U35, TGL122U40, TGL122U50, TGL124U35, TGL124U40, TGL124U50, TGLS114U, TGLS122U, TGLS124U
To reduce the risk of death, personal injury or property, damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards read all warnings and instructions included with and on the fixture box and all fixture labels. Commercial installation, service and maintenance of luminaires should be performed by a qualified licensed electrician.
DO NOT INSTALL DAMAGED PRODUCT
WARNING : RISK OF ELECTRIC SHOCK
- Turn off the electrical power at fuse or circuit breaker box before wiring fixture to power supply.
- Turn off the power when you perform any maintenance.
- Verify that supply voltage is correct by comparing it with the luminaire label information.
- Make all electrical and grounded connections in accordance with the National Electric Code and any applicable local code requirements.
- All wiring connections should be capped with UL approved wire connectors.
CAUTION : RISK OF INJURY
- Wear gloves and safety glasses at all times when removing luminaire from cartons, installing, servicing or performing maintenance.
- Avoid direct eye exposure to the light source while it is on.
- Account for small parts and destroy packaging material, as these may be hazardous to children.
- Ensure fixtures are properly secured to T-bar grid and/or ceiling using wire or aircraft cable capable of supporting 100lbs minimum.
CAUTION: RISK OF FIRE
- Keep combustible and other materials that can burn away from luminaire and lamp/lens.
- MIN 90°C SUPPLY CONDUCTORS
What’s In The Box
Tools Needed
This LED Troffer requires very few tools for installation. A drill or a screwdriver and a pair of wirecutter.
INSTALLATION INSTRUCTIONS
- Carefully unpack the fixture from its packaging. Inspect product for defects due to shipping
- Remove the ceiling panel. Place fixture into t-grid ceiling.
- Bend four (4) mounting/grid-tie clips up and out from the fixture. Secure safety cables through holes as required by local seismic requirements.
- Remove j-box cover by removing screw. Carefully remove knockouts for line voltage and 0-10V control wires
- Connect wiring to j-box with appropriate fittings. Line Voltage and 0-10V wiring must be connected in separate knockouts
- Connect wiring as shown. Pink and purple wiring are for 0-10V dimming systems. Cap off if not used.
- Reattach cover of junction box and secure with screw.
- For TGLS models, use selector switch to set desired CCT. Power on fixture and test for proper function.
Alternate Mounting Methods
Suspended Installation (cables/hardware supplied by others)
- Use properly rated and sized mounting hardware.
- Attached suspension cables through safety wire holes of the grid tie clips.
Surface Mount Installation
The TGL and TGLS are able to be installed in NICOR kits SK14M10WH, SK22M10WH
or SK24M10WH. Reference kit installation instructions for more information
LED EXPRESS LIMITED WARRANTY
Subject to the exclusions below, each NICOR LED product, including the LED electronics and components of a property installed NICOR LED product, will be free from defect in materials and workmanship for a period of five (5) years from the original date of purchase. The product shall be considered defective only if 10% or more of the product’s LED components fail. NICOR LED product warranty covers the following performance criteria: LED Light Output will be maintained above 70% of initial output; LED color temperature will not shift more than 200K in CCT; LED driver will operate within NICOR specifications; and the fixture finish, excluding natural aluminum or brass products, will not exhibit cracking, peeling, excessive fading, or corrosion during the warranty period. Exceptions apply as defined in NICOR’s product specification sheets, which are incorporated by reference herein.
This limited warranty is provided to you, the purchaser of the product identified on Seller’s invoice, as your exclusive remedy and applies only to NICOR products that have been purchased from an authorized NICOR Distributor; the product was new and in an unopened NICOR package at the time of installation; and the NICOR product was installed by a licensed electrician or under the supervision of a licensed electrician and used by consumers in the United States or Canada when accompanied with this warranty. This warranty extends only to the first consumer purchaser and is not transferable. A consumer wishing to invoke the terms of this limited warranty must first obtain a RGA number within 30 days of discovery of the defect, and return the product to NICOR for inspection.
Once verified to be covered by this limited warranty, NICOR will, at its sole discretion, repair, replace, or refund the purchase price of any product that does not conform to this limited warranty. If NICOR, at its sole discretion, determines that the product should be repaired or replaced, this warranty is limited to the reasonable, customary, and necessary costs and expenses associated with the repair/replacement. This warranty requires that all repair/replacement estimates and costs, including but not limited to equipment rental (if any), and any other cost or expense to be incurred in the repair/replacement of the product, be approved in advance and in writing by NICOR. FAILURE TO OBTAIN NICOR’S ADVANCE WRITTEN APPROVAL OF ALL REPAIR/REPLACEMENT COSTS AND EXPENSES IN WRITING SHALL VOID THIS LIMITED WARRANTY.
THIS LIMITED WARRANTY DOES NOT COVER THE FOLLOWING:
- Defects or damages resulting from improper installation, operation, storage, misuse or abuse, accident, or neglect;
- Defects or damages resulting from improper service, testing, adjustment, installation, maintenance, alteration, connection to out-of-specification electrical service, corrosive or damp environments, or connection to incompatible equipment or devices (e.g. connecting non-dimmable lighting products to dimmers);
- Damage which occurs in transit;
- Power surges or overheating due to external conditions
- Acts of nature including but not limited to lightning strikes
ANY IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE SHALL BE LIMITED TO THE DURATION OF THIS LIMITED WARRANTY, OTHERWISE THE REPAIR, REPLACEMENT, OR REFUND AS PROVIDED UNDER THIS EXPRESS LIMITED WARRANTY IS THE EXCLUSIVE REMEDY OF THE CONSUMER, AND IS PROVIDED IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. IN NO EVENT SHALL NICOR BE LIABLE, WHETHER IN CONTRACT OR IN TORT (INCLUDING NEGLIGENCE)
FOR DAMAGES IN EXCESS OF THE PURCHASE PRICE OF THE PRODUCT, OR FOR ANY INDIRECT, INCIDENTAL, SPECIAL OR CONSEQUENTIAL DAMAGES OF ANY KIND, OR LOSS OF REVENUE OR PROFITS, LOSS OF BUSINESS OR OTHER FINANCIAL LOSS ARISING OUT OF OR IN CONNECTION WITH THE ABILITY OR INABILITY TO USE THE PRODUCT TO THE FULL EXTENT THESE DAMAGES MAY BE DISCLAIMED BY LAW. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including inter-ference that may cause undesired operation.
NOTE : This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including inter- ference that may cause undesired operation.
NOTE : This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
NICOR, Inc. 2200 Midtown Place NE, Albuquerque, NM 87107
- P : 800.821.6283
- F : 800.892.8393
- www.nicorlighting.com
December 16, 2021 5:04 PM rev 1.0
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>