AIPHONE AC Series Access Control Solution Instruction Manual

June 9, 2024
AIPHONE

Installation Manual

KIT PART NUMBER

ACS-2DR-C|
ACS-ELV|
ACS-IO|
ACS-2DR (Trove Starter)|
Part Number

AC-2DE|
AC-IOE|

Package Contents

AIPHONE AC Series Access Control Solution - fig

UL 294 / S319 Compliance Notices
This product complies with the following UL294 Access Control Performance Levels when installed as part of the Listed AC-NIO system :
Endurance Level IV (100,000c)
Line Security Level I
Wiring methods shall be in accordance with the National Electrical Code (ANSI/NFPA70), CSA C22.1, Canadian Electrical Code, Part I, Safety Standard for Electrical Installations, Part I, local codes, and the authorities having jurisdiction. All interconnecting devices must be UL Listed, low-voltage Class 2 power limited. The minimum permissible wire size to be used shall not be less than 26 AWG (0.24 mm2).
Products have been evaluated for “Indoor Use” only, and to be installed within the “protected” or “restricted” area. This product is not intended for outside wiring as covered by Article 800 in the National Electrical Code, NFPA 70. Products are not intended to be installed or mounted in air-handling spaces. Products are intended to be installed by manufacturer trained service installers only All recommended connected peripherals such as power supplies, UPS/battery backups, PoE switches, electrified  strikes, readers require to be UL Listed.
Please refer to the AC-NIO UL Reference document for more comprehensive information available via the installation USB drive or downloadable from our website. Hard copy of the AC-NIO UL Reference Manual document is available – call for pricing.

Door Installation Example

AIPHONE AC Series Access Control Solution

Networking ExampleAIPHONE AC Series Access Control Solution -
Networking

Cable Requirements

Name Maximum Distance Cable Type Code
Network Cable*** 100 m (328′) twisted pair, 4 pairs Cat5 100BASE-T or

better
Reader Cable| 18 AWG: 152 m (500′) 22 AWG: 76.2 m (250′)*”| 6 conductor stranded not twisted, 22 AWG or thicker, 100% overall shielded| Belden 5304FE or equivalent
Door Strike Cable| 152 m (500′)| 2 conductor stranded 18 AWG| Aiphone 821802 or equivalent

Output Cable| 152 m (500′)| 2 conductor stranded 22 AWG| Aiphone 822202 or equivalent
Input Cable| 152 m (500′)| 2 conductor stranded 22 AWG, shielded| Aiphone 822202 or equivalent

RS-485 Cable with Power| 600 m (2000′)| 4 conductor stranded, twisted pair, 2 pairs, 22 — 16 AWG*, shielded| Belden 9402 or equivalent

  • Unless otherwise specified by manufacturer.
    ** Varies by current consumption of the other side.
    * RecommendedT T568B wiring for both ends.
    **
    Max distance may vary depending on cable gauge, environmental conditions and reader model.
    T568B (TIA/EIA568B) Wiring

1 .White/Orange
2. Orange
3. White/Green
4. Blue| 5. White/Blue
6. Green
7. White/Brown
8. Brown
---|---

Power Connection

AIPHONE AC Series Access Control Solution - Power
Connection

Optional Backup Battery

  • DC 12.8V ~ 14V recommended if a backup battery is used.
    Outputs & Usage Example
    Specification (AC-2DE)
Lock Power(wet) Lock power relay, 1GND, 2 12V DC 500mA
12V Out 12V DC output, 1 GND, 2  12V DC 500mA
Relay(dry) 30V DC 1A limit

Specification (AC-IOE)

12V Out 12V DC output,1 GND, 2 12V DC 200mA
Relay(dry) 30V DC 500mA limit
  • All the relay outputs are configurable.
    For example, any relay can be configured to a door strike.AIPHONE AC Series
Access Control Solution - Wet Relays

Note : Output Test

Readers & Usage Example
Wiring Specification

Ground Black and shield wires 1
Power (12V DC) Red wire2
LED Brown wi3re
Buzzer Blue wire4
Data 1 White wire5
Data 0 Green wire6

AIPHONE AC Series Access Control Solution - Usage
Example

Inputs & Usage Example
Specification

1-2 Pin (Input1) 1. Input2. Common (GND)
2-3 Pin (Input2) 2 . Common (GND) 3.Input

* All the inputs are configurable.
For example, Input1 can be configured to a doorbell or a door contact of Door_2AIPHONE AC Series Access Control Solution - Door
Contact

Input Types
Specification

Digital* Off(DO), On(DC)
Supervised* Off(SO), On(SC), Short(DC), No connection(DO)
  • Software selectable

    1. Digital Input StatesAIPHONE AC Series Access Control Solution - Input States
    2. Supervised Input StatesAIPHONE AC Series Access Control Solution - Input States 1

Address Setting
Each expander board must be set an unique address to talk to the master controller. A DIP switch is used to set the address.
Elevator kits require that AC-2DE dip switch be set to 9 as per dip switch adressing table.AIPHONE AC Series Access Control Solution -
switch

Address* A0    A1    A2    A3
1 on      off       off      off
2 off      on       off      off
3 on      on       off      off
4 off      off       on      off
5 on      off       on      off
6 off      on       on      off
7 on      on       on      off
8 off      off       off      on
9 on      off       off      on
10 off      on       off      on
11 on      on       off      on
12 off      off       on      on
13 on      off       on      on
14 off      on       on      on
15 on      on       on      on
00 (disabled) off      off       off      off

*Address range restriction : AC-IOE board(01 ~ 08), other boards(01 ~ 15)

Board I/O and Connections

AC-2DE I/O and Connections

LEDs

D1 System heart beat
D2 Server log on/off state Blink : Incorrect address
D3 Input Changed
D12 Receive data
D16 Transmit data
D20 Power
D24 Relay1 on
D26 Relay2 on
D27 Relay3 on
D30 Relay4 on
D34 Relay5 on
D36 Relay6 on
D55 Reader1 data flow
D56 Reader2 data flow

Connectors & Etc

P1 Relay1, DC 12V 500mA, wet
P2 Relay2, dry*
P3 Relay3, dry*
P5 Relay4, DC 12V 500mA, wet
P6 Relay5, dry*
P7 Relay6, dry*
P9 Power, communication data
P10 Input1, Common, Input2
P11 Input3, Common, Input4
P12 Input5, Common, Input6
P14 Reader1
P15 Reader2
P16 DC 12V out, max 500mA
U2 DIP switch

A3~A0 : Panel address
F0 : Function_0

*DC 24V, 1A limit

AC-IOE I/O and Connections

LEDs

D1 System heart beat
D2 Server log on/off state

Blink : Incorrect address
D3| Input Changed
D7| Power
D11| Relay1 on
D12| Relay2 on
D13| Relay3 on
D14| Relay5 on
D15| Relay6 on
D16| Relay7 on
D17| Relay7 on
D18| Relay8 on
D23| Receive data
D27| Transmit data

Connectors

P1 Input1, Common, Input2
P2 Input3, Common, Input4
P3 Input5, Common, Input6
P4 Input7, Common, Input8
P9 Power, comm data
P10 DC 12V out, max 200mA
P11 Relay1, dry*
P12 Relay2, dry*
P13 Relay3, dry*
P14 Relay4, dry*
P15 Relay5, dry*
P16 Relay6, dry*
P17 Relay7, dry*
P18 Relay8, dry*

Etc

LS1 DC 12V out
U2 DIP switch

A3~A0 : Panel addr
F0 : Function_0
F1 : Function_1
F2 : Function_2
F3 : Function_3

AC-C(Large) Dimensions
(Lid not included)

AIPHONE AC Series Access Control Solution - Dimensions

Three Door Typical
(with two AC-2DE boards)
FCC Compliance Notices
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1)This device may not cause harmful interference.
(2)This device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case you will be required to correct the interference at your own expense.AIPHONE AC
Series Access Control Solution - Door Typical

Aiphone Corporation
Part Number : 19601-19602-19603-19604-19612-19614 Rev 12.22
www.aiphone.com