Curtron MCS-36 Microshield 36 Inch Black Air Barrier User Guide

June 9, 2024
Curtron

Curtron MCS-36 Microshield 36 Inch Black Air Barrier

Curtron-MCS-36-Microshield-36-Inch-Black-Air-Barrier-
product

Curtron Products, a Senneca Company 11502 Century Blvd., Cincinnati, OH 45246 800.833.5005
www.curtronproducts.com

Warranty

The Curtron MicroShield Air Barrier comes with a warranty. Please refer to the General Warranty Statement for more details.

Installation Dimension

Curtron-MCS-36-Microshield-36-Inch-Black-Air-
Barrier-fig- \(1\)

Model A B C D E F G H I J
MCS-36 900mm 95mm 347.5mm N/A 347.5mm 1200mm 95mm 347.5mm 295mm

347.5mm
MCS-48| 46mm| 100mm| 230mm| 215mm| 1800mm| 95mm| 695mm| 190mm| 695mm|
MCS-72| 123mm| | | | | | | | |

Installation Guide

Use the following guide when installing the Curtron MicroShield Air Barrier:

  1. Secure the unit to a sturdy location to avoid vibration. (i.e. solid beams above the door)

  2. Installing the unit inside the room. Do Not Install outside for any reason.
    Minimum clearance: Over 50 mm or 2 inches

  3. When the entrance is wider than the unit, installing two or more units in parallel is recommended. In this case, provide 20-40 mm gaps between the units.

  4. Don’t install the unit in a place where it may be splashed by water, exposed to excessive steam, explosive gas or corrosive gas.

Installing on a concrete wall

  1. To remove the mounting plate
    Unscrew the screws on the back of the main using body to remove the mounting plate.

  2. Installing the mounting bolts properly
    Determine where the bolt holes will be the mounting plate and pour epoxy into the bolt holes.

  3. When the epoxy has cured install the mounting plate (secure the plate according to the following diagram).

  4. Install the main body Set the main body onto the upper end of the mounting plate and Clamp it as shown.

  5. Fix the mounting plate in the premeasured position with tapping screws.

  6. Same as in step 3.4 2 inches is the required distance from the ceiling.

Wall Mounting Plate Extension Brackets Through bolt to Mullions.

Bi-parting or swing doors with proximity sensorsCurtron-
MCS-36-Microshield-36-Inch-Black-Air-Barrier-fig- \(12\) Curtron-MCS-36-Microshield-36-Inch-Black-Air-Barrier-
fig- \(13\) Curtron-
MCS-36-Microshield-36-Inch-Black-Air-Barrier-fig- \(14\)

Center the mounting plate on door and attach to wall. The bottom of the mounting plate should be no more than 3″ above the door opening

Curtron-MCS-36-Microshield-36-Inch-Black-Air-Barrier-fig-
\(15\)

Hang Microshield on mounting plate and secure in place with the bottom mounting screws provided

Curtron-MCS-36-Microshield-36-Inch-Black-Air-Barrier-fig-
\(16\)

DO NOT MOUNT THE AIR BARRIER IN THIS CONFIGURATION.

  • DO NOT HANG THE AIR BARRIER ON
  • THE EXTERIOR OF THE BUILDING

Aluminum Mullions

MOUNTING MCS AIR BARRIER EXTENSION BRACKETSCurtron-MCS-36-Microshield-36
-Inch-Black-Air-Barrier-fig- \(17\) Curtron-MCS-36-Microshield-36-Inch-Black-Air-Barrier-fig-
\(18\)

  • 5/16 x 2 1/2 Bolts
  • 6 x 12 Extendable Mounting Bracket
  • Grounded Plug

For every inch above the door header, move the Air Barrier into the building 1/2″.

Intake Grill MCS Top View

  • Extension Brackets Rear Mounting Plate
  • Fixing Screws
  • Air Barrier
  • 1/4 x 1 Bolts Air Barrier

Setting up the Curtron MicroShield Air BarrierCurtron-
MCS-36-Microshield-36-Inch-Black-Air-Barrier-fig- \(19\) Approx. 10-15 % of the airflow should be directed outwards in order to prevent cold draft by the floor. To find the airflow’s split location hold a handkerchief by the corner approximately 2-3 inches above the floor and move it gently back and forth in the doorway. The split location should be in the middle of the doorway or a little outside.

Magnetic Reed Switch Installation

Curtron-MCS-36-Microshield-36-Inch-Black-Air-Barrier-fig-
\(20\)

ELECTRICAL SCHEMATICS

Curtron-MCS-36-Microshield-36-Inch-Black-Air-
Barrier-fig- \(21\)

OPERATION

  1. Plug in Air Barrier
  2. Turn on Air Barrier
  3. Select the desired speed
  4. Adjust diffuser (page 9)

MAINTENANCE

  1. Unplug the unit before performing any maintenance.
  2. Clean the Air Barrier regularly. Use a damp cloth to wipe the exterior surfaces. DO NOT USE SOLVENTS OR OTHER HARSH CHEMICAL CLEANERS!!!
  3. Blow or vacuum out the interior as required. It is important that the blower wheels remain free of dust build up to prevent them from becoming unbalanced which will lead to premature failure. Failure to clean the units’ interior will void warranty!
  4. Check diffuser setting periodically. Adjust as required. See page 9.
  5. Check that magnetic switch and actuator are secure and working.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>