HALCYON R580 High Colour Rendering Instruction Manual

June 10, 2024
HALCYON

HALCYON R580 High Colour Rendering

HALCYON-R580-High-Colour-Rendering-PRODUCT-IMG

DIMENSION

HALCYON-R580-High-Colour-Rendering-FIG-1

Installation Directions

  1. Switch off the mains power supply
  2. Connect Dimmable Driver to the mains voltage cable (L, N) Do not connect the downlight to the driver if the driver is live. Inrush current from the live driver will cause instant downlight failure. Do not switch the secondary side.
  3. Carefully install downlight into Precut 82mm hole.
  4. Turn on the mains power and switch on the lighting circuit.

Approved Clearances

Note: 0mm is required but 25mm is always recommended for optimum product lifespan through effective heat dissipation.

Example 1
0mm Approved Height Clearance. Building element abutting rear, insulation abutting sides of the fitting.

HALCYON-R580-High-Colour-Rendering-FIG-2

Example 2
0mm Approved Side Clearance. Building element abutting side of the fitting, insulation abutting, and covering fitting.

HALCYON-R580-High-Colour-Rendering-FIG-3

The driver is designed to be covered and abutted with IC / IC-F-approved insulation.

HALCYON-R580-High-Colour-Rendering-FIG-5

Cutting of holes prior to receiving goods is entirely at the risk of the installer.

10 Basalt Place, East Tamaki, Auckland, PO Box 58-501, Botany, Manukau 2163, Auckland, New Zealand Ph (0064 9) 273-9177 Fax (0064 9) 273 9155 Email: [email protected] Web: www.halcyonlights.co.nz

CLASSIFICATION SHEET

  • Manufacturer/ Supplier: Halcyon Lighting Ltd
  • Product Code: R580
  • Product Type: LED Recessed Luminaire
  • Primary Voltage: 220-240V~50/60Hz
  • Secondary Voltage: 260mA Constant Current
  • Wattage: 10W
  • Ingress Protection Rating: IP21

Classification

| |

IC-F – building insulation that can safely be continuously exposed to 90°C allowed to abut and cover the luminaire.

---|---|---

| IC-4 – building insulation that can safely be continuously exposed to 90°C allowed to abut and cover the luminaire.

In the vicinity of the recessed luminaire, use an insulation product that:

  • Maintains its dimensions and structural integrity when exposed to a temperature of 90°C; and
  • Withstands a 30-second needle flame test carried out in accordance with AS/NZS 60695.11.5 with the flame applied to all surfaces of the sample.

The rear of the fitting may abut structural members and building elements.
Do not install through or directly into the joist, beam, rafter or ceiling batten.

  • Side Clearance from the heatsink to building element (e.g. timber, joist or batten) SCB: 0mm
  • Height Clearance from heatsink to building element (e.g. timber, joist or batten) HCB: 0mm
  • Minimum insulation clearance to building element MIC: 0mm

Recessed luminaires and their associated equipment may pose a risk of fire or damage to property if not installed and maintained correctly. Halcyon recommends a clearance of 25mm to building elements for optimum lifespan.

Halcyon IC-F-rated luminaires are completely safe to install in sarked timber ceiling linings.
Halcyon accepts no responsibility if the timber used is not treated correctly and dries out, cracks or warps over time due to the constant low heat from the aforementioned “IC-F Rated” LED recessed lighting.

This data sheet contains the information necessary to ensure compliance with New Zealand Electrical Code of Practice for Installation and Maintenance of Recessed Luminaires and Associated Equipment AS/NZS 60598.2.2:2001

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

HALCYON User Manuals

Related Manuals