HALCYON R600 LED Recessed Luminaire User Manual

June 10, 2024
HALCYON

HALCYON R600 LED Recessed Luminaire

HALCYON-R600-LED-Recessed-Luminaire-product

Specification

  • Manufacturer I Supplier Halcyon Lighting Ltd
  • Product Code R600
  • Product Type LED Recessed Luminaire
  • Primary Voltage 220-240V~50/60Hz
  • Secondary Voltage 350mA 32VDC Constant Current
  • Wattage 11W
  • Ingress Protection Rating IP44

Classification| | IC – building insulation that can safely be continuously exposed to 90°C allowed to abut and cover the luminaire.
---|---|---

In the vicinity of the recessed luminaire, use an insulation product that:

  • Maintains its dimensions and structural integrity when exposed to a temperature of 90°C; and
  • Withstands a 30-second needle flame test carried out in accordance with AS/NZS 60695.11.5 with the flame applied to all surfaces of the sample.

The rear of the fitting may abut structural members and building elements. Do not install through or directly into the joist, beam, rafter, or ceiling batten.

  • Side Clearance from the heatsink to building element (e.g. timber, joist or batten) SCB: 0mm
  • Height Clearance from the heatsink to building element (e.g. timber, joist or batten) HCB: 0mm
  • Minimum insulation clearance to building element MIC: 0mm

Recessed luminaires and their associated equipment may pose a risk of fire or damage to property if not installed and maintained correctly. Halcyon recommends a clearance of 25mm to building elements for optimum lifespan.

Halcyon IC-rated luminaires is completely safe to install in sarked timber ceiling linings with a gauge of less than 20mm. Halcyon accepts no responsibility if the timber used is not treated correctly and dries out, cracks or warps over time due to the constant low heat from the aforementioned “IC Rated” LED recessed lighting.

This data sheet contains the information necessary to ensure compliance with the New Zealand Electrical Code of Practice for Installation and Maintenance of Recessed Luminaires and Associated Equipment AS/NZS 60598.2.2:2001

Installation Directions

  1. Switch off the mains power supply
  2. Connect Dimmable Driver to the mains voltage cable (L, N) Do not connect the downlight to the driver if the driver is live. Inrush current from the live driver will cause instant downlight failure. Do not switch the secondary side.
  3. Carefully install downlight into pre-cut 125-135mm hole.
  4. Turn on the mains power and switch on the lighting circuit.

HALCYON-R600-LED-Recessed-Luminaire-fig- \(2\)

Approved Clearances

Note:
0mm is required but 25mm is always recommended for optimum product lifespan through effective heat dissipation.

Example 1:
0mm Approved Height Clearance. Building element abutting rear, insulation abutting sides of fitting.

Example 2:
0mm Approved Side Clearance. Building element abutting side of fitting, insulation abutting and covering fitting.

Wiring

HALCYON-R600-LED-Recessed-Luminaire-fig- \(5\)

Cutting of holes prior to receiving goods is entirely at the risk of the installer
10 Basalt Place, East Tamaki, Auckland, PO Box 58-501, Botany, Manukau 2163, Auckland, New Zealand
Ph (0064 9) 273-9177 Fax (0064 9) 273 9155 Email: sales@halcyonlights.co.nz Web: www.halcyonlights.co.nz.