HALCYON R936 W3 Square Low Glare Darklight Wall Light Instruction Manual
- June 10, 2024
- HALCYON
Table of Contents
W3 Square Low Glare Darklight Wall Light
Instruction Manual
Dimmable LED Wall Light
Product parameter:
Model No. | Current | Power | LED | Colour | Size:mm | Material | IP Grade |
---|---|---|---|---|---|---|---|
R936 W3 | 700mA | 3W | CREE | 3000K | 80x80x36mm | AL | IP 65 |
R936 B3 | 700mA | 3W | CREE | 3000K | 80x80x36mm | AL | P 65 |
R936 BS3 | 700mA | 3W | CREE | 3000K | 80x80x36mm | STS | P 65 |
Symbols
Class of protection (SELV)
LED light source.
The WEEE symbol. indicating separate collection for WEEE-Waste of electrical
and electronic equipment, consists of the cross-out wheeled bin.
All the material used Is up to standard.
SAFETY INSTRUCTIONS
Read these instructors carefully before commencing installation and retain for future reference. The luminaire should be installed by a licensed electrician and in accordance with local regulations. Make sure that the power is off before installation or maintenance. Install as described.
Installation Instructions without Housing
– Modification or misuse of the luminaire voids warranty.
– This LED luminaire must be connected to a constant current converter 700mA.
WARNING! Incorrect connection may damage the luminaire.
– Note the prescribed dimensions before assembly.
– The light from a LED luminaire is strong, avoid looking directly into the
light source.
– Halcyon Lighting is free to change the design. specifications and
instructions for assembly of the luminaire without notice.
– Conned the LED luminaire to the converter before the converter is connected
to the power source.
– All exterior luminaires (with the exception of copper) require periodic
cleaning to protect the surface and/or coating from corrosion and ensure tidy
appearance for the lifespan of the product. Wash with care using a soft brush
and warm soapy water using a neutral detergent. Coastal areas require extra
attention. especially fittings which are under eaves/soffits and do not have
any exposure to rain. Do not use a water blaster or high pressure hose, do not
submerge fittings for extended periods of time. 316 stainless steel fittings
will still develop surface rust or “tea staining” if left uncared for.
CLASSIFICATION SHEET / IC
Manufacturer / Supplier | Halcyon Lighting Ltd |
---|---|
Product Code | R936 |
Product Type | LED Recessed Luminaire |
Secondary Voltage | 700mA Constant Current |
Wattage | 3W |
Ingress Protection Rating | IP65 |
Classification |
exposed to 90°C allowed to abut and cover the luminaire.
---|---|---
In the vicinity of the recessed luminaire, use an insulation product that:
(a) Maintains its dimensions and structural integrity when exposed to a
temperature of 90°C; and (b) Withstands a 30-second needle flame test carried
out in accordance with AS/NZS 60695.11.5 with the flame applied to all
surfaces of the sample.
Rear of fitting may abut structural members and building elements.
Do not install through or directly into joist, beam, rafter or ceiling batten.
Side Clearance from heatsink to building element (e.g. timber, joist or
batten)| SCB: 0mm
---|---
Height Clearance from heatsink to building element (e.g. timber, joist or
batten)| HCB: 0mm
Minimum insulation clearance to building element| MIC: 0mm
Recessed luminaires and their associated equipment may pose a risk of fire or
damage to property if not installed and maintained correctly. Halcyon
recommends a clearance of 25mm to building elements for optimum lifespan.
Halcyon IC rated luminaires are completely safe to install in sparked
timber ceiling linings. Halcyon accepts no responsibility if the timber used
is not treated correctly and dries out, crack or warps over time due to the
constant low heat from the aforementioned “IC Rated” LED recessed lighting.
This data sheet contains information necessary to ensure compliance with the
New Zealand Electrical Code of Practice for Installation and Maintenance of
Recessed Luminaires and Associated Equipment AS/NZS 60598.2.2:2001