LITHONIA LIGHTING FML4W Wrap 4ft LED Wraparound Lights Instruction Manual

June 10, 2024
LITHONIA LIGHTING

LITHONIA-LIGHTING logo

FML4W Wrap 4ft LED Wraparound Lights

LITHONIA-LIGHTING FML4W Wrap 4ft-LED-Wraparound-Lights-product-
image

Product Information

This product is an LED luminaire that contains electronic devices generating frequencies above 9kHz. The product has specific instructions and safety precautions that must be followed to ensure safe and proper usage. The product comes with a hardware kit and required tools for installation.

Important Safety Instructions:

  • Read and follow all safety instructions before installing or using the product.
  • There is a risk of electric shock if connectors are not properly installed, and a risk of injury if the product is not handled with caution.
  • The product has a risk of burn, fire, and damage if not used according to the recommended type, burning position, mounting locations/methods, replacement, and recycling guidelines.
  • The product also has a risk of causing damage to other substances affected by heat or drying.
  • The product complies with Part 15 of the FCC Rules and must not cause harmful interference or receive interference that may cause undesired operation.
  • Failure to follow any of these instructions could void product warranties.

Required Tools

  • No specific tools are mentioned in the text, but it is implied that tools required for mounting the product to the ceiling type should be provided separately.

Included Fixture Components

PART DESCRIPTION QUANTITY
A LED Luminaire Housing 1
B LED Diffusion Lens 1

Supplied Hardware Kit Components

PART DESCRIPTION QUANTITY
C Wire Nut 3
D 8-32 x 1 Screw 2

Product Usage Instructions:

Installation
  1. Turn off the power.
  2. Remove the lens and hardware kit from the fixture by pressing in the middle of the lens on one end to lower the lens below the locating feature in the endcap. Slide the lens into the endcap to create a gap between the lens and endcap on the opposite end of the fixture. Use the exposed gap to gently reach under the lens and pull it away from the fixture to remove. Set the lens aside in a location where it will not fall or become damaged. Remove the bag with the hardware kit from inside of the fixture.
  3. The fixture must be centered over and mounted to the electrical junction box. If additional support is required, mounting locations at ends of fixture are provided. Have someone assist in holding the fixture against the ceiling. With fixture junction box mounting holes lined up with junction box, mark the end mounting locations on the ceiling.
  4. Use appropriate hardware for the ceiling type that fixture is be ing mounted to. A typical installation onto a drywall ceiling will use drywall anchors rated to hold at least 20 lbs.
  5. For all installs, partially thread screws (provided with junction box or 2x 8-32×1 screws provided in the hardware kit) into the junction box. Leave the head of the screw approximately 1/4 away from the box (do not tighten).

IMPORTANT SAFETY INSTRUCTIONS

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION

  • To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards please read all warnings and instructions included with and on the fixture box and all fixture labels.
  • Before installing, servicing, or performing routine maintenance upon this equipment, follow these general precautions.
  • Installation and service of luminaires should be performed by a qualified licensed electrician.
  • Maintenance of the luminaires should be performed by person(s) familiar with the luminaires’ construction and operation and any hazards involved. Regular fixture maintenance programs are recommended.
  • It will occasionally be necessary to clean the outside of the refractor/lens. Frequency of cleaning will depend on ambient dirt level and minimum light output which is acceptable to user. Refractor/lens should be washed in a solution of warm water and any mild, non-abrasive household detergent, rinsed with clean water and wiped dry. Should optical assembly become dirty on the inside, wipe refractor/lens and clean in above manner, replacing damaged gaskets as necessary.
  • DO NOT INSTALL DAMAGED PRODUCT! This luminaire has been properly packed so that no parts should have been damaged during transit. Inspect to confirm. Any part damaged or broken during or after assembly should be replaced.
  • Recycle: For information on how to recycle LED electronic products, please visit www.epa.gov.
  • These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to meet in connection with installation, operation, or maintenance. Should further information
    be desired or should particular problems arise which are not covered sufficiently for the purchaser’s or owner’s purposes, this matter should be referred to Acuity Brands Lighting, Inc.

WARNING RISK OF ELECTRIC SHOCK

  • Disconnect or turn off power before installation or servicing.
  • Verify that supply voltage is correct by comparing it with the luminaire label information.
  • Make all electrical and grounded connections in accordance with the National Electrical Code (NEC) and any applicable local code requirements.
  • All wiring connections should be capped with UL approved recognized wire connectors.

CAUTION RISK OF INJURY

  • Wear gloves and safety glasses at all times when removing luminaire from carton, installing, servicing or performing maintenance.
  • Avoid direct eye exposure to the light source while it is on.

WARNING RISK OF BURN

  • Allow lamp/fixture to cool before handling. Do not touch enclosure or light source.
  • Do not exceed maximum wattage marked on luminaire label.
  • Follow all manufacturer’s warnings, recommendations and restrictions for: driver type, burning position, mounting locations/methods, replacement and recycling.

CAUTION RISK OF FIRE

  • Keep combustible and other materials that can burn, away from lamp/lens.
  • Do not operate in close proximity to persons, combustible materials or substances affected by heat or drying.

CAUTION: RISK OF PRODUCT DAMAGE

  • Never connect components under load.
  • Do not mount or support these fixtures in a manner that can cut the outer jacket or damage wire insulation.
  • Unless individual product specifications deem otherwise: Never connect an LED product to dimmer packs, occupancy sensors, timing devices, or other related control devices. LED fixtures must be powered directly off a switched circuit.
  • Unless individual product specifications deem otherwise: Do not restrict fixture ventilation. Allow for some volume of airspace around fixture. Avoid covering LED fixtures with insulation, foam, or other material that will prevent convection or conduction cooling.
  • Unless individual product specifications deem otherwise: Do not exceed fixtures maximum ambient temperature.
  • Only use fixture in its intended location.
  • LED products are Polarity Sensitive. Ensure proper Polarity before installation.
  • Electrostatic Discharge (ESD): ESD can damage LED fixtures. Personal grounding equipment must be worn during all installation or servicing of the unit.
  • Do not touch individual electrical components as this can cause ESD, shorten lamp life, or alter performance.
  • Some components inside the fixture may not be serviceable. In the unlikely event your unit may require service, stop using the unit immediately and contact an ABL representative for assistance.
  • Always read the fixtures complete installation instructions prior to installation for any additional fixture specific warnings.
  • Verify that power distribution system has proper grounding. Lack of proper earth ground can lead to fixture failure and may void warranty.

All luminaires that contain electronic devices that generate frequencies above 9kHz from any component within the luminaire comply with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference
  2. This device must accept any interference received, including interference that may cause undesired operation.

Failure to follow any of these instructions could void product warranties. For a complete listing of product Terms and Conditions, please visit www.acuitybrands.com. Acuity Brands Lighting, Inc. assumes no responsibility for claims arising out of improper or careless installation or handling of its products.

ABL LED General Warnings, Form No. 503.203
© 2010 Acuity Brands Lighting, Inc. All rights reserved. 12/01/10

REQUIRED TOOLS:

Acuity-Brands-FML4W-Low-Profile-Wide-Housing-LED-Wrap
-01

INCLUDED FIXTURE COMPONENTS:

PART DESCRIPTION QUANTITY
A LED LUMINAIRE HOUSING 1
B LED DIFFUSION LENS 1

SUPPLIED HARDWARE KIT COMPONENTS

DESCRIPTION QUANTITY
WIRE NUT 3
8-32 x 1” SCREW 2

Acuity-Brands-FML4W-Low-Profile-Wide-Housing-LED-Wrap
-02 ADDITIONAL SUPPLIES MAY BE NEEDED
DEPENDING ON THE TYPE OF CEILING FIXTURE IS BEING MOUNTED TO:

  • Drywall or Masonry Anchors and Screws
  • Wood Screws
  • Toggle Bolts

INSTALLATION

Step One:
TURN OFF THE POWER!

Step Two:
Remove lens and hardware kit from fixture –
Press in middle of lens (A) on one end to lower lens below locating feature in endcap.
Slide lens into endcap (B) to create gap between lens and endcap on opposite end of fixture (C)
Use exposed gap to gently reach under lens and pull away from fixture to remove (D).
Set lens aside in a location where it will not fall or become damaged.
Remove bag with hardware kit from inside of fixture.

Acuity-Brands-FML4W-Low-Profile-Wide-Housing-LED-Wrap
-03 Step Three:
Prepare for fixture mounting –
The fixture must be centered over, and mounted to, the electrical junction box.
If additional support is required, mounting locations at ends of fixture are provided.
Have someone assist in holding the fixture against the ceiling.
With fixture junction box mounting holes lined up with junction box, mark the end mounting locations on the ceiling.
Use appropriate hardware for the ceiling type that fixture is being mounted to.
Typical installation onto a drywall ceiling will use drywall anchors rated to hold at least 20 lbs. Acuity-Brands-FML4W-Low-Profile-Wide-Housing-LED-Wrap
-04

For 2-3/4” electrical box only:
Use screwdriver to knock out covers in housing for additional mounting slots.
Pliers may be necessary to bend knockout several times to remove.

Acuity-Brands-FML4W-Low-Profile-Wide-Housing-LED-Wrap
-05

For all installs – partially thread screws (provided with junction box or 2x 8-32×1” screws provided in hardware kit) into junction box. Leave head of screw approximately 1/4″ away from box (do not tighten).

Step Four:
Make electrical connections in junction box –
DO NOT MAKE CONNECTIONS IN FIXTURE

Connect the hot and neutral (black and white) wires from the junction box to the corresponding wire colors from the fixture, using the provided wire nuts.

Also, connect the ground wire (green) from the fixture to the circuit ground using a wire nut.Acuity-Brands-FML4W-Low-Profile-Wide-Housing-LED-Wrap
-07

Step Five:
Attach fixture to junction box –
Position wires and connections up into junction box.
Lift fixture up and align larger opening of keyhole with heads of partially threaded screws from Step Three. Rotate fixture clockwise and tighten screws to secure housing to junction box.
Use appropriate fasteners at ends of fixture if required.

Step Six:
Reassemble lens to housing –
Start with lens parallel to fixture as shown below. With the end of lens 3-4 inches away from the endcap. Support middle of lens up against fixture with one hand.

  • Begin at the end of fixture with lens-endcap gap, place lens groove around flange of housing (A).
    Apply pressure to keep this edge pressed against flange. Acuity-Brands-
FML4W-Low-Profile-Wide-Housing-LED-Wrap -09

  • Next, flex first 1-2 feet of the other long edge of lens under flange and inside the housing (B). Lens can withstand significant bending without breaking. Acuity-Brands-FML4W-Low-Profile-Wide-Housing-LED-Wrap -10

  • Then, pull gently on lens (C) to clip lens groove around flange of housing (D). If lens pops out, please repeat this step from the beginning. Acuity-Brands-FML4W-Low-Profile-Wide-Housing-LED-Wrap -11

  • Finally; slide lens towards, and under, endcap (E).
    This should seat the lens groove around the housing flange down the length of the lens.
    Adjust any un-seated sections of lens groove to housing along the length of the fixture on both sides of lens. Center lens under endcaps so that no gaps exist. Acuity-Brands-FML4W-Low-Profile-Wide-Housing-LED-Wrap
-12

Scan QR code for lens installation video Acuity-Brands-FML4W-Low-Profile-
Wide-Housing-LED-Wrap -13http://lithonia.com/FML4Winstall

DIFFUSION LENS CLEANING:
Use a soft cloth and water to clean the lens. Avoid strong chemicals.
Mild soap or detergent combined with water may also be used, be sure to fully rinse lens with clean water. Allow lens to air dry before reinstalling.

USE OF ADJUSTABLE LUMEN OUTPUT (ALO) – (IF LUMINAIRE IS EQUIPPED WITH THIS OPTION):

LITHONIA-LIGHTING FML4W Wrap 4ft-LED-Wraparound-
Lights-01

Setting Approx. Wattage % Approx. Lumen %
8 100% 100%
7 100% 100%
6 98% 98%
5 88% 89%
4 78% 80%
3 66% 70%
2 55% 58%
1 43% 46%

WITH POWER OFF and the lens removed from fixture (either before or after the fixture is installed on ceiling) Use a ¼ inch flathead screwdriver to adjust the central knob of the lumen output device.
Follow the instructions on the label in the fixture, shown above, or consult table above for output settings. Leave ALO at setting 8 (to provide maximum dimming range) if using 0-10V dimming below.

0-10V DIMMING – (IF LUMINAIRE IS EQUIPPED WITH THIS OPTION):

Purple and Pink (or gray) wires for low voltage 0-10V control are provided in light fixtures with that option –
DO NOT CONNECT PURPLE OR PINK (OR GRAY) WIRES TO LINE VOLTAGE
If unfamiliar with 0-10V wiring, contact a qualified electrician.

A ½ inch knockout (KO) is provided to run these wires out of the light fixture to connect to 0-10V controls –
While fixture is on floor or a stable surface (not installed), use screwdriver to knock out ½ KO in housing. Pliers may be necessary to bend knockout several times to remove.

MAKE SURE POWER IS OFF

Route the wires through KO and make connection to low voltage (0-10V) controls outside of fixture.
Pre-cut insulation on ends of purple and pink (or gray) wire will need to be removed before making connections (wire nuts not included).

LITHONIA-LIGHTING FML4W Wrap 4ft-LED-Wraparound-
Lights-02

If using with a 0-10V wall dimmer, follow installation and use instructions that are provided with the dimming wall switch.

Leave the insulation ends on the purple and pink (or gray) wires unless they will be used for 0-10V dimming. If insulation is removed, prevent contact with metal fixture housing by individually capping the purple and pink (or gray) wires with a wire nut (not included). Do not tie these wires together or fixture will be in constant dimmed output.

PLEASE RETAIN THESE INSTRUCTIONS !

Documents / Resources

| LITHONIA LIGHTING FML4W Wrap 4ft LED Wraparound Lights [pdf] Instruction Manual
FML4W Wrap 4ft LED Wraparound Lights, FML4W Wrap, 4ft LED Wraparound Lights, LED Wraparound Lights, Wraparound Lights, Lights
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

LITHONIA LIGHTING User Manuals

Related Manuals