Enerdrive EPL-100BT-12V-SLIM B-TEC Lithium Ion Phosphate Prismatic Cell Battery with Smart Phone Monitoring Owner’s Manual

June 10, 2024
Enerdrive

Enerdrive EPL-100BT-12V-SLIM B-TEC Lithium Ion Phosphate Prismatic Cell

Battery with Smart Phone Monitoring

Enerdrive B-TEC Lithium (LiFePO4) Battery with Smart Phone Monitoring

The Enerdrive B-TEC Lithium (LiFePO4), Lithium Ion Phosphate Prismatic Cell Battery with Smart Phone Monitoring is a high-performance battery that must be used properly for safe and optimum performance. This battery comes with a user manual that provides all the necessary instructions and guidelines for safe use. Please read and follow all instructions carefully, paying special attention to the CAUTION and WARNING statements to prevent damage to the battery and avoid harm or serious injury.
The B-TEC battery is available in the following models:

  • EPL-100BT-12V-SLIM
  • EPL-125BT-12V-G2
  • EPL-200BT-12V-G2
  • EPL-300BT-12V-G2
  • EPL-100BT-24V
  • EPL-150BT-24V-G2
  • EPL-100BT-36V

Installation

Your B-TEC battery must be installed in a dry and cool location. The supplied battery trays and straps are the preferred mounting method, and sufficiently rated fasteners should be used to hold the tray firmly to the mounting material. The battery should have 25mm clear space around it, and consideration should be taken to not mount it near any metallic service lines such as LPG, diesel, or petrol lines. The battery must not be installed in vehicle engine bays or wet areas such as caravan chassis mounts, open ute trays, or boat deck areas. Refer to Section 10 – Battery Specifications for further installation requirements.

Connection

The spring washers must be used on the battery terminal bolts to apply pressure to the lugs for a secure connection. There is no need to over-tighten the bolts, simply ensure there is no movement of the cables. Make sure the main Battery Cable lug is mounted directly onto the Battery terminal with no washers between them.

Charging

The B-TEC battery can be charged using a standard charger or an Enerdrive ePOWER DC2DC+ Battery Charger. Please refer to Section 3

  • Charging in the user manual for detailed charging instructions.

Discharging

The B-TEC battery can be used to power various devices and equipment. Please refer to Section 4 – Discharging (Using the Battery) in the user manual for detailed instructions on how to use the battery safely and efficiently.

Protecting Your Battery

It’s important to protect your B-TEC battery from overcharging, over- discharging, and short-circuiting. Please refer to Section 5 – Protecting Your Battery in the user manual for detailed instructions on how to protect your battery.

Restarting Your Battery

If your B-TEC battery shuts down due to low voltage, it can be restarted using a suitable charger. Please refer to Section 6 – Restarting Your Battery in the user manual for detailed instructions on how to restart your battery.

Using the Smart Phone Battery Monitor App

The B-TEC G2 battery comes with a Smart Phone Battery Monitor App that allows you to monitor the battery’s performance and status. Please refer to Section 7 – Using the Smart Phone Battery Monitor App in the user manual for detailed instructions on how to use the app.

Warnings
Please refer to Section 8 – Warnings in the user manual for important safety warnings and precautions to follow when using the B-TEC battery.

FAQ
Please refer to Section 9 – FAQ in the user manual for answers to frequently asked questions about the B-TEC battery.

Battery Specifications
Please refer to Section 10 – Battery Specifications in the user manual for detailed specifications on the B-TEC battery.

Dimensions
Please refer to Section 11 – Dimensions in the user manual for detailed dimensions of the B-TEC battery.

Warranty

Please refer to Section 12 – Warranty in the user manual for information on the warranty for the B-TEC battery. For any further support, you can contact Dometic Power & Control (Enerdrive) Pty Ltd at [email protected] or refer to the website www.enerdrive.com.au.

For safe and optimum performance, the Enerdrive ePOWER B-TEC LiFePO4 Lithium Ion Phosphate Battery with Smart Phone Monitoring must be used properly. Carefully read and follow all instructions and guidelines in this manual and give special attention to the CAUTION and WARNING statements.

PLEASE KEEP THIS MANUAL FOR FUTURE REFERENCE
Disclaimer
While every precaution has been taken to ensure the accuracy of the contents of this guide, Enerdrive assumes no responsibility for errors or omissions. Note as well that specifications and product functionality may change without notice.

Important
Please be sure to read and save the entire manual before using your Enerdrive ePOWER B-TEC LiFeP04 Lithium Ion Phosphate Battery with Smart Phone Monitoring. Misuse may result in damage to the battery, and/or cause harm or serious injury. Read manual in its entirety before using the unit and save manual for future reference.

Product Number

  • EPL-100BT-12V-SLIM
  • EPL-125BT-12V-G2
  • EPL-200BT-12V-G2
  • EPL-300BT-12V-G2
  • EPL-100BT-24V
  • EPL-150BT-24V-G2
  • EPL-100BT-36V

Document Part Number

  • Enerdrive B-TEC G2 Manual (Rev. 3.0) 2021

Support Contact Information

Dometic Power & Control (Enerdrive) Pty Ltd
Warranty Returns: Reply Paid 8786, Wynnum Plaza, QLD 4178 Email: [email protected]
www.enerdrive.com.au

Installation

  • Your B-TEC battery must be installed in a dry and cool location.
  • Supplied battery trays and straps are the preferred mounting method. Ensure that sufficiently rated fasteners are used to hold the tray firmly to the mounting material.
  • Enerdrive approve the installation of B-TEC batteries in accommodation areas of RV’s. Temperatures must not exceed the rated operating temperatures therefore natural, or fan-forced ventilation may be required.
  • There should be 25mm clear space around the B-TEC battery.
  • Consideration should be taken to not mount the battery near any metallic service lines such as LPG, diesel, or petrol lines. This is t o ensure no accidental shorting of the battery terminals occurs, especially when fitting or removing the battery.

B-TEC batteries must not be installed –

  • In vehicle engine bays or in high heat environments, refer to Section 10 – Battery Specifications
  • In wet areas such as caravan chassis mounts, open ute trays or boat deck areas.
  • Inside compartments dedicated to carrying gas.

Refer to applicable transportable structures or marine standards for further installation requirements.

Connection

  • It is recommended that no more than four terminals be connected to a battery terminal, if you do have more than 4 terminals the use of a fuse block and negative busbar are recommended.
  • Cable terminal should be order with heaviest current draw in contact with the battery to light current draw terminals on the top.
  • Use of insulating terminal boots is recommended, especially in areas where accidental shorting may occur, such as storage lockers or under lounges and beds.Connect the Positive (Red) and Negative (Black) cables to the battery, ensuring you are using cable that is of adequate size for the demands of the system, and well crimped and protected termination lugs.

Example;

  • 1000W Inverter – at least Guage 2 (35mm²)
  • 2000W Inverter – at least Guage 00 (70mm²)

Cable Conversion Guide The spring washers must be used on the battery terminal bolts – they apply pressure to the lugs for a secure connection. There is no need to over-tighten the bolts, simply ensure there is no movement of the cables. Make sure the main Battery Cable lug is mounted directly onto the Battery terminal with no washers between them.

Charging
Lithium batteries need to be charged slightly different to other batteries.
To ensure they live a long life and provide maximum capacity, you must use a charger with a lithium LiFeP04 setting – this includes:

  • AC Chargers
  • DC to DC Chargers
  • Solar Controllers

If your charger allows, set the charge voltage from 14.2 – 14.6 Volts and Float 13.5 – 13.6 Volts and proceed with charging. We recommend charging at the lower end of the voltage scale for maximum longevity of the battery.
It is recommended that the charging current should be 30% of your battery capacity. You can charge at higher currents but 30% is the recommended for long life.
– Battery Specifications.

*Note:
You can charge a lithium battery with a non-lithium charger, but these chargers can deliver too much or too little voltage and may not cut off when the battery is full.
DO NOT use a charger with a “Pulse Stage” or “Equalisation Mode”. This will damage the battery and void warranty.
DO NOT connect this battery to a start battery with a VSR (Dual Battery System or “Voltage Sensitive Relay”). The voltage of the Lithium battery may keep the VSR switched on resulting in it discharging into the start battery.

Discharging (using the battery)

  • The Enerdrive B-TEC Lithium Battery can deliver a very high discharge current due to the high power, high quality Battery Management System (BMS) and prismatic Lithium cells inside the battery.
  • Refer to Section 10 – Battery Specifications for the maximum rated discharge current of your battery.
  • For this to happen, you MUST USE cable of the correct guage.

Consider current like plumbing The thicker the pipe (cable) the more current can flow through it.
These are recommended wire guages and approximate current specifications for cable lengths shorter than 1 – 2 metres:

A 2000W inverter will draw approximately 170-180 Amps through the cables connected between it and the battery – this will NOT be achieved with undersized wire.

Inverter Usage

It is recommended to not put more load on your batteries than the rating of the BMS installed. We also recommend following the below even if you have two batteries in parallel, this protects overloading a single battery if the other battery in the bank was to shut down (i.e. low capacity).

  • 12V 100AH B-TEC – 12V 1000W Inverter Max
  • 12V 125AH B-TEC – 12V 1000W Inverter Max
  • 12V 200AH B-TEC – 12V 2600W Inverter Max
  • 12V 300AH B-TEC – 12V 3500W Inverter Max
  • 24V 150AH B-TEC – 24V 3500W Inverter Max

Protecting Your Battery
Lithium batteries cannot be protected effectively by monitoring voltage due to their ability to maintain a higher voltage for much longer than AGM or flooded/sealed batteries.
“State of Charge” (SOC%) percentage is the most accurate and effective method of disconnecting loads from the battery – this requires a battery monitor which uses a “shunt” to measure the current going into (Charging) and coming out of (Discharging) the battery.
Example;

  • It is recommended that Lithium batteries not be discharged below 20% State of Charge or the battery life may be shortened.
  • As an added layer of protection, the Enerdrive B-TEC Lithium Battery also has a built-in low voltage disconnect circuit. If this occurs, please refer to Section 6 – Restarting Your Battery.
  • If your battery has shut down due to low voltage you must charge your battery within 14 days to prevent permanent damage occuring to the cells.

Restarting Your Battery

  • Batteries with Reset Button on Battery
  • We strongly recommend keeping the battery charged to avoid activating the internal low battery voltage discconnect.

If your DC system shuts down, the battery may require re-starting. Please use the following procedure:

  1. Turn off all DC and AC Loads
  2. Connect charging source/s and switch ON
  3. Hold the “Reset” button on top of the battery for 5-10 seconds
  4. Release and wait 7 seconds
  5. Power should now be restored and charging will commence
  6. When the SOC (State of Charge) is above 20%, loads can be switched on if required

By continuously tripping the low voltage discconnect of the battery you may cause damage to sensitive electronic equipment that is attached to the battery. i.e. battery chargers, solar controllers, inverters, stereo equipment etc – all of which are not covered under the battery warranty.

Batteries without Reset Button on Battery
To reconnect, a charge voltage of ≥12.8v must be applied to the battery before the over-discharge release will activate and allow charge current to flow into the battery. This can be done via a momentary reset switch between the start battery and B-TEC or by jump starting with a portable power pack. Follow the above steps to turn off all DC and AC loads, turn on charging sources and then activate reset switch or apply jump start pack, disconnect as soon as chargers beging charging.

Using the Smart Phone Battery Monitor App
The Enerdrive B-TEC Lithium Battery incorporates a wireless Smart Phone Monitoring system. By downloading the Android™ or Apple® app to your Smart Phone or tablet device, you can monitor the following information;

  • Battery Capacity
  • Battery Voltage
  • Battery Current (Amps)
  • Battery State of Charge (SOC)
  • Battery State of Health (SOH)
  • Battery Status
  • Individual Cell Voltage
  • Battery Temperature
  • Battery Cycles
  • Battery Alarms
  • Battery Event Information

Alarms Definitions

  • HV – High Voltage
  • LV – Low Voltage
  • OCC – Over Current Charge
  • OCD – Over Current Discharge
  • LTD – Low-Temperature Discharge
  • LTC – Low-Temperature Charge
  • HTD – High-Temperature Discharge
  • HTC – High-Temperature Charge

(Refer to Section 10 – Battery Specifications for values).

  • Red light is only an indicator, not a fault condition.
  • The default password is 1234 (this allows you to change the Bluetooth name of the battery).
  • A notification will only appear in the notifications page if under alarm conditions.

Warnings
Please read and follow the cautions listed on the battery before installation. Improper use may cause heat, fire, rupture, damage or capacity deterioration of the battery. Enerdrive Pty Ltd is not responsible for any accidents cause by the usage without following our specifications.

Failure to follow these instructions may result in early battery failure or possible personal injury.

  • Do not use the battery for cranking/starting applications.
  • DO not series connect the battery.
  • Do not dispose of in fire.
  • The battery must be installed far away from heat sources, high voltage, and avoid exposed sunlight for long periods Of time.
  • Do not throw the battery into water.
  • Do not connect the positive and negative terminals of battery together.
  • DO not ship or store battery together with metal.
  • Do not disassemble the battery. Battery warranty will be voided if the case is opened.
  • DO not drop, impact or puncture the battery.
  • Do not allow the battery to sit in a discharged states11.50V
  • When the battery capacity is low SOC), please charge the battery.
  • Please use the matched or suggested charger that contains a Lithium charge profile for this battery. Failure to install the correct battery charger will void all warranty.
  • If the battery emits a peculiar smell, heating, distortion or appears to have any abnormality during operation or storage, please stop using the battery and take it out Of service. Contact Enerdrive for further details
  • If the battery leaks and gets into eyes or on skin, do not wipe. Rinse with clean water and seek medical attention immediately.

Low Battery Voltage Disconnect
The battery has a low-voltage disconnect incorporated for self-protection. If the battery is drawn down to the internal low voltage disconnect set point (2.8v per cell) the battery will disconnect.

FAQ

Q: Can I parallel B-TEC batteries?
A: The short answer is yes.

  • The long answer is – if you are drawing large currents, the maximum current delivered will be limited to the maximum instantaneous discharge capacity of one battery (200 Amps).
  • With low to medium current draw installations (the vast majority of applications) you may never see an issue and your storage capacity will be greatly increased – I.E. 2 x 200 Amp = 400 Amp capacity.
  • When installing, ensure they are fully charged, separately – then let sit for 30 minutes before connecting together. When connecting in parallel – take the positive from Battery 1, and the negative from Battery 2 to your system as per the diagram below.
  • The Smart Phone App will only show the information from one battery at a time – not both. This is another advantage of a separate Battery Monitor – it will show the total system environment.

*Note : Slight variance of State of Charge or Amps may occur between the batteries in parallel however these should not vary by more than 5%.
It is recommend that annually the batteries be disconnected and individually charged allowing them to sit at state for 12hrs each before connecting together.

  • Q: Can I series connect B-TEC batteries to achieve higher voltage?
    A: No. Enerdrive offers higher voltage Lithium solutions – contact us for details.

  • Q: Can I use an Inverter with my B-TEC battery?
    A: Yes. Refer to Section 4 for more detail.

  • Q: Can I install the B-TEC battery in a wet area?
    A: No. Due to the construction of the B-TEC cases the batteries must be installed in a dry environment to
    protect against moisture ingress.

  • Q: Can I install the B-TEC battery on its side or end?
    A: No.

Specifications

SPECIFICATIONS: Enerdrive B-TEC 12v-G2 Lithium Battery Technical Data – 12 VOLT

**| EPL-100BT-12V-SLIM| EPL-125BT-12V-G2| EPL-200BT-12V-G2| EPL-300BT-12V-G2**
Nominal Voltage| 12.8V
Nominal Capacity| 100Ah| 125Ah| 200Ah| 300Ah
Cycle Life (DOD – 80%

under controlled conditions)

| ≥2000 Cycles
Standard Charge Specification (Lithium profile charger required)
Battery Charge Temperature| 0 – 45˚C
Normal Charge Voltage CV/CC*| 14.20 ~14.60
Standby (Float) Voltage| 13.50 ~13.80
Maximum Charge Current| 80A @ 25˚C for 30mins| 80A @ 25˚C for 30mins| 150A @ 25˚C for 30mins| 190A @ 25˚C for 30mins
Nominal Charge Current for Maximum Life| 20~50A| 20~60A| 40~100A| 80~120A
Standard Discharge Specification
Battery Discharge Temperature| -20˚C ~ 60˚C
Battery Output Voltage Range| 11.0 ~ 14.60V approx.
Maximum Discharge Current| 100A @ 25˚C ±5˚C for 30 mins| 100A @ 25˚C ±5˚C for 30 mins| 200A @ 25˚C ±5˚C for 30 mins| 250A @ 25˚C ±5˚C for 15 mins
Pulse Discharge Current| 250A for 1.0s| 450A for 1.0s
Discharge Cut-Off Voltage| ≤11.20V
Circuit Protection
The battery is supplied with a LiFePO4 Battery Management System (BMS) that can monitor and optimise each single prismatic cell during charge & discharge, to protect the battery pack from overcharge, over discharge & short circuit. Overall, the BMS helps to ensure safe and accurate operation of the battery.
Over-Charge Protection
Over-Charge Protection Per Cell| 3.90 ± 0.03V
Over-Charge Release Per Cell| 3.60 ± 0.05V
Over-Charge Release Method| Discharge below release voltage
Over-Discharge Protection
Over-Discharge Protection Per Cell| 2.80V ± 0.05V
Over-Discharge Release Per Cell| 3.20V ± 0.05V
Over-Disharge Release Method| Apply Charge/Voltage ≥12.8v
Over Current Protection
Discharge Over Current| 110A for 30s – 450A for 1s| 110A for 30s – 450A for 1s| 220A for 30s – 450A for 1s| 280A for 25s – 400A for 3.5s
Protection Reset Time| Approx 10s Auto Release
Over Current Release Method| Disconnect Load
Over Temperature Protection


Battery Discharge Over Temp

| Protection to 65˚C  ± 5˚C
Protection to 50˚C  ± 5˚C
Battery Charge Over Temp| Protection to 55˚C  ± 5˚C
Protection to 45˚C  ± 5˚C
Short Circuit Protection| Auto release after 5s
Mechanical Characteristics| Without Tray| Without

Tray

| With

Tray

| Without

Tray

| With

Tray

| Without

Tray

| With

Tray



Dimensions

| Length| 551mm| 318mm| 318mm| 505mm| 505mm| 521mm| 521mm
Width| 110mm| 165mm| 165mm| 173mm| 173mm| 280mm| 288mm
Height| 240mm| 232mm| 240mm| 265mm| 272mm| 253mm| 261mm
Weight                 Approx. 12.5kg| Approx. 15.5kg| Approx. 16.2kg| Approx. 25.0kg| Approx. 26.0kg| Approx. 38.2kg| Approx. 39.4kg
Storage Information


Temperature & Humidity Range

| ≤30 days – 20˚C to 35˚C, 45% to 75% RH
≥30 days – 10˚C to 30˚C, 45% to 75% RH
Self-Discharge Rate| ≤3% per month
SPECIFICATIONS: Enerdrive B-TEC Lithium Battery Technical Data – 24 & 36 VOLT

**| EPL-100BT-24V| EPL-150BT-24V-G2| EPL-100BT-36V**
Nominal Voltage| 25.6V| 25.6V| 38.4V
Nominal Capacity| 100Ah| 150Ah| 100Ah
Cycle Life (DOD – 80%

under controlled conditions)

| ****

≥2000 Cycles

Standard Charge Specification (Lithium profile charger required)
Battery Charge Temperature| 0 – 45˚C
Normal Charge Voltage CV/CC*| 28.80 ~29.20| 28.80 ~29.20| 43.20 ~43.80V
Standby (Float) Voltage| 27.00 ~27.60| 27.00 ~27.60| 40.5 ~41.40V
Maximum Charge Current| 50A @ 25˚C for 30mins| 100A @ 25˚C for 60mins| 50A @ 25˚C for 30mins
Recommended Charge Current for Maximum Life| 20~50A| 30~75A| 20~50A
Standard Discharge Specification
Battery Discharge Temperature| -20˚C ~ 60˚C
Battery Output Voltage Range| 22.0 ~ 29.20V| 22.0 ~ 29.20V| 33.0 ~ 43.80V
Maximum Discharge Current| 100A @ 25˚C ±5˚C for 30 mins| 150A @ 25˚C ±5˚C for 30 mins| 100A @ 25˚C ±5˚C for 30 mins
Pulse Discharge Current| 450A for 1.0s
Discharge Cut-Off Voltage| ≤22.40V| ≤22.40V| ≤33.60V
Circuit Protection
The battery is supplied with a LiFePO4 Battery Management System (BMS) that can monitor and optimise each single prismatic cell during charge & discharge, to protect the battery pack from overcharge, over discharge & short circuit. Overall, the BMS helps to ensure safe and accurate operation of the battery.
Over-Charge Protection
Over-Charge Protection Per Cell| 3.90 ± 0.03V
Over-Charge Release Per Cell| 3.60 ± 0.05V
Over-Charge Release Method| Discharge below release voltage
Over-Discharge Protection
Over-Discharge Protection Per Cell| 2.80V ± 0.05V
Over-Discharge Release Per Cell| 3.20V ± 0.05V
Over-Disharge Release Method| Apply Charge/Voltage ≥25.6v| Apply Charge/Voltage ≥25.6v| Apply Charge/Voltage ≥38.4v
Over Current Protection
Discharge Over Current| 110A for 30s – 450A for 1s| 170A for 10s – 400A for 3.5s| 110A for 30s – 450A for 1s
Protection Reset Time| Approx. 30s Auto Release
Over Current Release Method| Disconnect Load
Over Temperature Protection
Battery Discharge Over Temp| Protection to 65˚C  ± 5˚C
Protection to 50˚C  ± 5˚C
Battery Charge Over Temp| Protection to 55˚C  ± 5˚C
Protection to 45˚C  ± 5˚C
Short Circuit Protection| Auto release after 5s
Mechanical Characteristics| Without Tray| Without Tray| With Tray| Without Tray


Dimensions

| Length| 446mm| 521mm| 521mm| 520mm
Width| 161mm| 280mm| 288mm| 273mm
Height| 245mm| 253mm| 261mm| 225mm
Weight| Weight| Approx. 25.0kg| Approx. 38.2kg| Approx. 39.4kg| Approx. 37.7kg
Storage Information


Temperature & Humidity Range

| ≤30 days – 20˚C to 60˚C, 5 ~ 75% RH
≥90 days – 10˚C to 45˚C, 5 ~ to 75% RH
Self-Discharge Rate| ≤3% per month

EPL-100BT-12V-SLIM

DIMENSIONS

(NO STRAP & TRAY INCLUDED WITH THIS MODEL)

EPL-125BT-12V-G2 EPL-200BT-12V-G2EPL-125BT-12V-G2 EPL-200BT-12V-G2 EPL- 200BT-12V-G2 EPL-300BT-12V-G2 EPL-300BT-12V-G2 EPL-100BT-24V EPL-150BT- 24V-G2
DIMENSIONS WITHOUT STRAP & TRAY EPL-150BT-24V-G2
DIMENSIONS WITH STRAP & TRAY EPL-100BT-36V

Warranty

5 Year Warranty
In the unlikely event that a technical issue arises with an Enerdrive product, customers are encouraged to initially contact the Enerdrive Support Team on 1300 851 535 or [email protected] for immediate and efficient expertise and first class product support.

Important Note: Consumer Protections
If you have purchased your product in Australia, you should be aware that:
This warranty is provided in addition to other rights and remedies held by a consumer at law. Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and for compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure.

Enerdrive warrants that its Products will be free from defects in materials and workmanship (subject to limits, and in normal conditions, as described in the complete Enerdrive Warranty Policy) for up to 5 years from the date of purchase. For full terms, conditions and claim process, refer to the Enerdrive website. https://enerdrive.com.au/warranty/

Dometic Power & Control (Enerdrive) Pty Ltd
P.O. Box 9159, Wynnum Plaza, Queensland, Australia 4178 Ph: 1300 851 535 / Fax: 07 3390 6911
Email: [email protected]
Web: www.enerdrive.com.au

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Enerdrive User Manuals

Related Manuals