DEPSTECH DS600 Industrial Endoscope User Manual
- June 10, 2024
- DEPSTECH
Table of Contents
Industrial Endoscope
DS600
Multi-Language User Manual
Product manual
DEPSTECH ® DS600 industrial endoscope was featured as a cost efficient industrial endoscope with 4.3” digital screen, which was invented to help car maintenance or pipeline repairing. We hope that you can use this efficient tool to enable you to finish the job more rapidly and help you discover the delights of miniature worlds.
Battery
Please do not try to change the built-in battery yourself, it may raise the risks of leading the battery overheat or get people harmed. For better battery life spans, we would recommend you charge the device every 3~6 months. (No matter uses it or not)
Operation and storage conditions
Please keep the tools out of fire source, especially keep it away from temperature higher than 158 ℉ (70 ℃ ) – or lower than -50 ℉ (-10 ℃ ). Be cautious the required working temperature should between 32~113 ℉ (0~45 ℃ ). Please keep it in dry, clean area, free from oil, water, or chemical liquid. Those measures will help the device maintain longer lifes pans, also it will do great help to keep the dangerous situation far away. ※ The Child can only operate this device with the guidance of adults, please do not let them operate this device alone.
Product introduction
-
Power Button
Hold this button for 2s to power on / off the endoscope. -
Button
Confirm choice / Long press to enter the album or exit the album / Click to play or pause; -
Button
a: Time adjustment
b: In the menu mode, select the next directory
c: Click to dim the LED lightness
d: Press 2 seconds to rotate the image 180° -
“ ” Button
a: Time adjustment
b: In the menu mode, select the previous directory
c: Click to brighten the LED lightness
d: Press 2 seconds to change the lens -
“ ” Button
Hold this button to start video record, single press to take a photo/end the video record. -
Menu Button
Click to enter the menu for more setttings. -
LED indicator
Red LED indicator flash: Charging status
Red LED indicator stay on: Charging finished
Green LED indicator flash: Low power
Green LED indicator stay on: Power system work normally -
TF Card Slot
Support up to 32G TF card. (The TF card has been inserted into the machine, please format it for the first time of usage) -
Type-C Port
Charge the endoscope via the Type-C cable Data transmission via Type-C data cable -
Reset Button
Short click the reset button with the reset pin to shut down the device. -
Aviation connector
Replaceable different cable
Description of Product Functions:
Photo / Video: Take photos by pressingc button, long press to start video
recording, single press to end video recording.
View Photos: Long press in preview mode to enter the photo album, and press to
view photos. Long press again to exit the photo album.
Delete Photos: When viewing photos, press to choose to delete the current
photo or delete all photos.
Screen Rotation: Long press the rotation button, and the image will rotate
180°.
Lens Switching (only applicable to double-lens products): Long press the
button to switch among main lens, side lens and dual-lens.
Lens LED Brightness Adjustment: Click the key to lower the brightness,
and click the key to increase the brightness.
Screen freeze:
When previewing the interface, click the button to freeze the frame.
Copy photo and video files to computer:
- Use a TF card reader to copy data directly
- Use a Type-C cable to connect to computer for copying Setting path
a. Please connect the product to your computer
b. Press the “MENU” button to enter the menu
c. Select “Data transmission”
d. Press the “OK” key to start copying to computer
If the product is not connected with computer, click “Data transmission” on the setting screen, the USB logo will appear on the display, please press the “MENU” button to exit.
Introduction to the Menu Interface:
Enter the MENU interface: Press to enter the menu interface, press to select
options, and then press to enter the option interface. Press again to exit.
- Resolution Setting: Enter the resolution interface, press to select the resolution, and then press to confirm;
- Language Setting: Enter the language setting interface, press to select the language, and then press to confirm;
- Auto OFF Setting: Enter the Auto OFF setting interface, press to select the time, and then press to confirm;
- TF Card Formatting: Enter the formatting interface, choose whether to format, and then press to confirm;
- System Reset: Enter the System Reset Interface, choose whether to restore the factory settings, and then press vbto confirm;
- Time Setting: Enter the time setting interface, press to select the year, month, day, minute and second to be adjusted, press to adjust the time, and press to exit after setting;
- Storage Space: Check the memory card capacity and the remaining memory;
- Software Version: Check the firmware version number of this product.
Charging Guide:
- Connect the device to the DC 5V adapter for charging;
- The red indicator light flashes when the device is charging, and is always on when fully charged.
Specifications
Model | DS600 Dual Camera |
---|---|
Screen Spec | 4.3” LCD Screen |
Camera Diameter | 0.31 in |
Best Focal Range | 1.18-3.15 in / 0.79-2.36 in |
Video Spec | 1080 P / 25 FPS |
Photo Resolution | 2 x 2 MP |
Battery Life | 4~5H |
Charging time | 3~4H |
Charging Voltage and Current | DC 5V/2A |
FAQ
Q1: The image quality wasn’t that good as advertised?****
– A1: Please adjust the length between the camera and the object that you’re observing into the focal range. The focal range should be 1.18”~3.15” for single camera version, and 1.18”~3.15” / 0.79”~2.36” in for dual camera version. Besides, it’s essential to adjust the brightness of your endoscope for the best image quality. It will do a great help if you wipe the lens of the camera regularly after used.
Q2: The endoscope was failing to turn on?****
– A2: It might due to low battery status, especially in cold area. To release the low battery state you’ve to fully charge the endoscope. You can charge the endoscope for 4~5 H and try to turn it on again.
Q3: The endoscope can not take a picture or record a video?****
– A3: First please make sure that the TF card has been inserted into the machine or not. Then make sure that you’ve formatted the TF card at the first use.
You can follow the steps below:
- Short press menu
- Find and choose “Format”, then choose “OK”.
※ FCC Requirement: Changes or modifications not expressly approved by the
party responsible for compliance could void the user’s authority to operate
the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference
that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses,
and can radiate radio frequency energy, and if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
– Reorient or relocate the receiving antenna.
– Increase the separation between the equipment and receiver.
– Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
– Consult the dealer or an experienced radio/TV technician for help.
※ CE compliance: This device complies with EN 60065 standard, which
means this device will not do harm to the user or products as following
situations:
1)Electric shock 2)High temperature 3)Radiation 4)Explosion from inner
5)Mechanical Harm 6)Fire Hazard 7)Chemical burns.
※ EU Conformity Statement: This product and – if applicable – the
supplied accessories too are marked with “CE” and comply therefore with the
applicable harmonized European standards listed under the EMC Directive
2004/108/EC, the RoHS Directive 2011/65/EU and Amendment (EU) 2015/863.
※ WEEE Notice: 2012/19/EU (WEEE directive): Products marked with this symbol
cannot be disposed of as unsorted municipal waste in the European
Union. For proper recycling, return this product to your local supplier upon
the purchase of equivalent new equipment, or dispose of it at designated
collection points. For more information see:
www.recyclethis.info ※ 2013/56/EU (battery
directive): This product contains a battery that cannot be disposed of as
unsorted municipal waste in the European Union. See the product documentation
for specific battery information. The battery is marked with this symbol,
which may include lettering to indicate cadmium (Cd), lead (Pb), or mercury
(Hg). For proper recycling, return the battery to your supplier or to a
designated collection point. For more information see:
www.recyclethis.info
EC REP 1: Like Sun GmbH. Planckstr.59, 45147 Essen, Germany
EC REP 2: DST Co., Ltd. Fifth Floor 3 Gower Street, London, WC1E 6HA, UK
Customer Services
Please contact us if you have any questions, we love to hear from you
****www.depstech.com
support@depstech.com
support.uk@depstech.com
support.de@depstech.com
support.jp@depstech.com
Facebook Official Page: @DEPSTECH.FANS
Shenzhen Deepsea Innovation Technology Co., Ltd.
Room 1901-1902, Jinqizhigu Building, No.1 Tangling Road, Nanshan District,
518055, Shenzhen, CN
Made in China
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>