HALCYON R767 Ecolight 195mm White Downlight Instruction Manual
- June 10, 2024
- HALCYON
Table of Contents
Ecolight 195mm White Downlight
Instruction Manual
Installation Directions
- Switch off mains power supply
- Connect Dimmable Driver to mains voltage cable (L, N) Do not connect downlight to driver if driver is live. Inrush current from live driver will cause instant downlight failure. Do not switch secondary side.
- Carefully install downlight into Precut 170mm hole.
- Turn on mains power and switch on lighting circuit.
Approved Clearances
Note: 25mm for optimum product lifespan through effective heat
dissipation.
Example 1:
25mm Approved Height Clearance. Building elements cannot abut rear of fitting.
Example 2:
25mm Approved Side Clearance. Building elements cannot abut side of fitting.
Driver is designed to be covered and abutted with IC / IC-F approved insulation.
Cutting of holes prior to receiving goods is entirely at the
risk of the installer.
10 Basalt Place, East Tamaki, Auckland, PO Box 58-501, Botany, Manukau 2163,
Auckland, New Zealand.
Ph (0064 9) 273-9177 Fax (0064 9) 2739155
Email: sales@halcyon.co.nz
Web: www.halcyonlights.co.nz
CLASSIFICATION SHEET
Manufacturer / Supplier | Halcyon Lighting Ltd |
---|---|
Product Code | R767 |
Product Type | LED Recessed Luminaire |
Primary Voltage | 220-240V~50/60Hz |
Secondary Voltage | 350mA 54VDC Constant Current |
Wattage | 21W |
Ingress Protection Rating | IP44 |
Classification | -F — building insulation that can safely be bards |
continuously exposed to 90°C allowed to abut a) and cover the luminaire.
In the vicinity of the recessed luminaire, use an insulation product that:
(a) Maintains its dimensions and structural integrity when exposed to a
temperature of 90°C; and
(b) Withstands a 30-second needle flame test carried out in accordance with
AS/NZS 60695.11.5 with the flame applied to all surfaces of the sample.
Rear of fitting may abut structural members and building elements.
Do not install through or directly into joist, beam, rafter or ceiling batten.
Side Clearance from heatsink to building element (e.g. timber, joist or
batten)| SCB: 25mm
---|---
Height Clearance from heatsink to building element (e.g. timber, joist or
batten)| HCB: 25mm
Minimum insulation clearance to building element| MIC: O mm
Recessed luminaires and their associated equipment may pose a risk of fire or
damage to property if not installed and maintained correctly. Halcyon
recommends a clearance of 25mm to building elements for optimum lifespan.
Halcyon IC-F rated luminaires are completely safe to install in sparked
timber ceiling linings. Halcyon accepts no responsibility if the timber used
is not treated correctly and dries out, crack or warps over time due to the
constant low heat from the aforementioned “IC-F Rated” LED recessed lighting.
This data sheet contains information necessary to ensure compliance with the New Zealand Electrical Code of Practice for Installation and Maintenance of Recessed Luminaires and Associated Equipment AS/NZS 60598.2.2:2001