CURRENT CULTURE H2O RDWC Recirculating Deep Water Culture Owner’s Manual
- May 15, 2024
- CURRENT CULTURE H2O
Table of Contents
- CURRENT CULTURE H2O RDWC Recirculating Deep Water Culture
- Product Information
- Product Usage Instructions
- System Feature Overview
- Remote Epicenter Option
- PUMP BANK WITH AIR FLOW REGULATOR
- Growth Module Dimensions & Volumes
- Power Requirements
- Plumbing
- Materials
- Warranty
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
CURRENT CULTURE H2O RDWC Recirculating Deep Water Culture
Product Information
Specifications
- Product Name: Recirculating Deep Water Culture- RDWC
- System Features:
- Return Water Pump
- UC Spin Tight Bulkhead
- Epicenter (Control Module)
- Drain Out Valve
- Delivery Manifold
- Joint Return Hose Growth Module
- AIR PUMP BANK
- High-Flow Aeration Manifold
Product Usage Instructions
Setting Up the System
- Place the system in the desired location.
- Connect the return water pump to the UC Spin Tight Bulkhead.
- Attach the delivery manifold and joint return hose growth module to the system.
- Connect the air pump bank to the system’s aeration manifold.
- Adjust the air flow regulator for optimal performance.
Maintenance and Cleaning
- Regularly clean out the system using the clean out tee.
- Inspect all components for any signs of damage or wear.
- Monitor water levels and adjust as necessary.
- Keep the system free from debris and obstructions.
Frequently Asked Questions (FAQ)
Q: Where is the air pump bank typically located?
A: The air pump bank is generally located outside the grow environment to
minimize heat and noise inside the growing area.
Q: How do I choose the right system size for my needs?
A: Consider factors such as available space,number of plants, and desired
yield when selecting a system size. Refer to the product dimensions to ensure
a proper fit.
Recirculating Deep Water Culture – RDWC
Under Current systems offer a simple-to-operate irrigation pproach, well-
suited for applications ranging from CEA indoor to sun-grown greenhouses. RDWC
systems recirculate oxygenated nutrient solution through the plant’s root zone
24/7 ensuring pH, EC and temperature levels are uniform throughout the system
during the growing cycle. This approach results in unmatched productivity,
efficiency, and ease of use, and is ideal for integration with automation and
fertigation systems for commercial standardization.
System Feature Overview
AIR PUMP BANK
Generally located Outside Grow Environment
Remote Epicenter Option
All Under Current® systems are available with a “Remote Epicenter” option.
This allows growers to place the Epicenter (Control Module) on the outside of
their grow space or tent.
PUMP BANK WITH AIR FLOW REGULATOR
CODE | PRODUCT DESCRIPTION | SYSTEM DIMENSIONS |
---|---|---|
UC4 | Under Current 4 | 2’10.5″ x 5’4.5″ / 0.88m x 1.64m |
UC6 | Under Current 6 | 2’10.5″ x 6’10.5″ / 0.88m x 2.10m |
UC8 | Under Current 8 | 2’10.5″ x 8’4.5″ / 0.88m x 2.55m |
UC12 | Under Current 12 | 2’10.5″ x 11’4.5″ / 0.88m x 3.47m |
UC16 | Under Current 16 | 2’10.5″ x 14’5″ / 0.88m x 4.40m |
CODE | PRODUCT DESCRIPTION | SYSTEM DIMENSIONS |
---|---|---|
UCE9 | Under Current Evolution 9 | 4’7″ x 6’10.5″ / 1.4m x 2.10m |
UCE12 | Under Current Evolution 12 | 4’7″ x 8’4.5″ / 1.4m x 2.55m |
UCE18 | Under Current Evolution 18 | 4’7″ x 11’4.5″ / 1.4m x 3.47m |
UCE24 | Under Current Evolution 24 | 4’7″ x 14’4.5″ / 1.4m x 4.40m |
CODE | PRODUCT DESCRIPTION | SYSTEM DIMENSIONS |
---|---|---|
UCDB16 | Under Current Double Barrel 16 | 8’9″ x 8’4.5″ / 2.67m x 2.55m |
UCDB24 | Under Current Double Barrel 24 | 8’9″ x 11’4.5″ / 2.67m x 3.47m |
UCDB32 | Under Current Double Barrel 32 | 8’9″ x 14’4.5″ / 2.67m x 4.40m |
CODE | PRODUCT DESCRIPTION | SYSTEM DIMENSIONS |
---|---|---|
UC4XL | Under Current 4XL | 3’2.5″ x 5’11.5″ / 0.98m x 1.82m |
UC6XL | Under Current 6XL | 3’2.5″ x 8’0.5″ / 0.98m x 2.45m |
UC8XL | Uc8xl Under Current 8XL | 3’2.5″ x 10’1.5″ / 0.98m x 3.09m |
UC12XL | Uc12xl Under Current 12XL | 3’2.5″ x 14’3.5″ / 0.98m x 4.36m |
UC16XL | Uc16xl Under Current 16XL | 3’2.5″ x 18’5.5″ / 0.98m x 5.63m |
CODE | PRODUCT DESCRIPTION | SYSTEM DIMENSIONS |
---|---|---|
UCE9XL | Under Current Evolution 9XL | 5’2.5″ x 8’0.5″ / 1.59m x 2.45m |
UCE12XL | Under Current Evolution 12XL | 5’2.5″ x 10’1.5″ / 1.59m x 3.09m |
UCE18XL | Under Current Evolution 18XL | 5’2.5″ x 14’3.5″ / 1.59m x 4.36m |
UCE24XL | Under Current Evolution 24XL | 5’2.5″ x 18’5.5″ / 1.59m x 5.63m |
CODE | PRODUCT DESCRIPTION | SYSTEM DIMENSIONS |
---|---|---|
UCDB16XL | Under Current Double Barrel 16XL | 9’4.5″ x 10’1.5″ / 2.86 x 3.09m |
UCDB24XL | Under Current Double Barrel 24XL | 9’4.5″ x 14’3.5″ / 2.86m x 4.36m |
UCDB32XL | Under Current Double Barrel 32XL | 9’4.5″ x 18’5.5″ / 2.86m x 5.63m |
CODE | PRODUCT DESCRIPTION | SYSTEM DIMENSIONS |
---|---|---|
UC4XL13 | Under Current 4XL13 | 3’8″ x 6’8.5″ / 1.12m x 2.04m |
UC6XL13 | Under Current 6XL13 | 3’8″ x 9’2.5″ / 1.12m x 2.81m |
UC8XL13 | Uc8xl Under Current 8XL13 | 3’8″ x 11’8.5″ / 1.12m x 3.57m |
UC12XL13 | Uc12xl Under Current 12XL13 | 3’8″ x 16’8.5″ / 1.12m x 5.09m |
UC16XL13 | Uc16xl Under Current 16XL13 | 3’8″ x 21’8.5″ / 1.12m x 6.62m |
CODE | PRODUCT DESCRIPTION | SYSTEM DIMENSIONS |
---|---|---|
UCE9XL13 | Under Current Evolution 9XL13 | 6’2″ x 9’2.5″ / 1.88m x 2.81m |
UCE12XL13 | Under Current Evolution 12XL13 | 6’2″ x 11’8.5″ / 1.88m x 3.57m |
UCE18XL13 | Under Current Evolution 18XL13 | 6’2″ x 16’8.5″ / 1.88m x 5.09m |
UCE24XL13 | Under Current Evolution 24XL13 | 6’2″ x 21’8.5″ / 1.88m x 6.62m |
CODE | PRODUCT DESCRIPTION | SYSTEM DIMENSIONS |
---|---|---|
UCDB16XL13 | Under Current Double Barrel 16XL13 | 11’2″ x 11’8″ / 3.40m x 3.57m |
UCDB24XL13 | Under Current Double Barrel 24XL13 | 11’2″ x 16’8.5″ / 3.4m x 5.09m |
UCDB32XL13 | Under Current Double Barrel 32XL13 | 11’2″ x 21’8.5″ / 3.40m x |
6.62m
CODE | PRODUCT DESCRIPTION | SYSTEM DIMENSIONS |
---|---|---|
UC4XXL13 | Under Current 4XXL13 | 4’6″ x 7’6.5″ / 1.37m x 2.30m |
UC6XXL13 | Under Current 6XXL13 | 4’6″ x 10’10.5″ / 1.37m x 3.31m |
UC8XXL13 | Uc8xl Under Current 8XXL13 | 4’6″ x 14’2.5″ / 1.37m x 4.33m |
UC12XXL13 | Uc12xl Under Current 12XXL13 | 4’6″ x 20’10.5″ / 1.37m x 6.36m |
UC16XXL13 | Uc16xl Under Current 16XXL13 | 4’6″ x 27’6.5″ / 1.37m x 8.39m |
CODE | PRODUCT DESCRIPTION | SYSTEM DIMENSIONS |
---|---|---|
UCE9XXL13 | Under Current Evolution 9XXL13 | 7’10” x 10’10.5″ / 2.39m x 3.31m |
UCE12XXL13 | Under Current Evolution 12XXL13 | 7’10” x 14’2.5″ / 2.39m x 4.33m |
UCE18XXL13 | Under Current Evolution 18XXL13 | 7’10” x 20’10.5″ / 2.39m x 6.36m |
UCE24XXL13 | Under Current Evolution 24XXL13 | 7’10” x 27’6.5″ / 2.39m x 8.39m |
CODE | PRODUCT DESCRIPTION | SYSTEM DIMENSIONS |
---|---|---|
UCDB16XXL13 | Under Current Double Barrel 16XXL13 | 12’10” x 14’2.5″ / 3.91m x |
4.33m
UCDB24XXL13| Under Current Double Barrel 24XXL13| 12’10” x 20’10.5″ / 3.91m x
6.36m
UCDB32XXL13| Under Current Double Barrel 32XXL13| 12’10” x 27’6.5″ / 3.91m x
8.39m
Growth Module Dimensions & Volumes
Power Requirements
EACH UNDER CURRENT SYSTEM’S WATER/AIR PUMPS ARE SIZED FOR THE TOTAL SYSTEM VOLUME, ASK YOUR SALES CONSULTANT FOR SPECIFIC WATER/AIR PUMPS INCLUDED WITH YOUR MODEL.
Plumbing
Materials
Part Name | Description | Size | Material | Color/Attributes |
---|---|---|---|---|
Multi-Mod | Plant Growth Module | 8-gallon, 13-gallon | Polypropylene (PP) |
Black, UV Resistant
CCH20 Lid| Lid for Growth Module| One Size| Acrylonitrile Butadiene Styrene
(ABS)| White, UV Resistant
CCH20 Net Pot| Mesh Basket to Hold Plant| 5.5″, 8″| Polypropylene (PP)| Black,
UV Resistant
UC Spin Tight Bulkhead| Module/Pipe Interface| 2″, 3″| Acrylonitrile Butadiene
Styrene (ABS)| Black, UV Resistant
Manifold Piping| Module to Module Plumbing| 2″, 311| Acrylonitrile Butadiene
Styrene (ABS)| White
Manifold Fittings
Manifold Caps/Sleeves
| Pipe Fittings – Tees, Nipples, Ball Valves
Pipe Fitting Caps & Connecting Sleeves
| 2″, 3″
211, 311
| Polyvinyl Chloride (PVC)
Vinyl
| White
Black
Multi-Mod Drop Tee| Growth Module Drain Fitting| 1″ Barb| Acrylonitrile
Butadiene Styrene (ABS)| Black, UV Resistant
CCH20 Bulkhead Filter| Screen Filter for Bulkheads| 2″, 3″| Polypropylene
(PP)| Black
Float Valve| Maintains Water Level| 1/2″ MPT| Polyvinyl Chloride (PVC)| Grey,
White
Mazzei Injector| Venturi Injector (Add Back Kit)| 3/4″ MPT| Nylon| Black
Return Water Hose| Manifold to Pump Connection| 1.25″ OD, 1″ ID| Flexible
Polyvinyl Chloride (FPVC)| Blue
Drain Hose| Connects Drop Tee Drain Fittings| 1.25″ OD, 1″ ID| Flexible
Polyvinyl Chloride (FPVC)| Grey
Aeration Hose| Connects Air Pump to Air Stones| 0.170″, 3/4″, l”| Ethylene
Vinyl Acetate (EVA)| White
Top-Off Hose| Connects Float Valve to Reservoir| 1/2″ OD| Polyethylene (PE)|
Blue
Add-Back Kit Hose| Attaches to Mazzei Injector| 3/8″| Flexible Polyvinyl
Chloride (FPVC)| Clear
Uniseal| Rubber Grommet| 1″| Rubber| Black
Grommet| Air Line Inlet| 3/8″| Rubber| Black
Y-Splitter| Conjoins 2 Return Hoses| 1″ Barb| Nylon| Natural
Bulkhead Gasket| Creates Seal in Bulkhead| 2″, 3″| Rubber| Black
Bulkhead 0-Ring| Creates Seal in Bulkhead| 2″, 3″| Rubber| Black
Air Stone| Creates Air Bubbles| N/A| Glass Bonded Silica| Grey, White
Push-Connect Fittings| Used in Add-Back Kit| 3/8″| Polypropylene (PP)| White
1/4″ Aeration Fittings| Used in Aeration Manifold| 1/4″ barb| Acrylonitrile
Butadiene Styrene (ABS)| Black
314’1 Aeration Manifold Fittings| Used in Aeration Manifold| 3/4″|
Acrylonitrile Butadiene Styrene (ABS)| Black
1″ Drain Manifold Fittings| Used in Drain Manifold| 1″| Acrylonitrile
Butadiene Styrene (ABS)| Black
Drain & Aeration Manifold Caps| Used in Drain/Aeration Manifold| 3/4″, l”|
Vinyl| Black
Warranty
Current Culture H2D Limited 3-Year Warranty
This limited warranty applies only to full systems manufactured at Current
Culture H20 in Fresno, CA.
Warranty Includes
- All individual components manufactured by Current Culture H20 come standard with a THREE year limited warranty.
- All Air & Water pumps are covered by their specific manufacturer’s warranty. Manufacturer instructions and warranty information booklets are provided with each pump. If any issues with these units covered within their individual warranties should occur, please contact the manufacturer for repair or replacement.
Warranty Excludes
- This limited warranty excludes any components considered to be expendable (i.e. hoses, air diffusers, net pots,seals, etc.). These items should be replaced periodically to ensure proper system functionality.
Review our full warranty along with return information at: www.cch2o.com/warranty/