HALCYON R827 Dimmable Tilt 30 and Rotate 360 Degrees Installation Guide
- June 10, 2024
- HALCYON
Table of Contents
HALCYON R827 Dimmable Tilt 30 and Rotate 360 Degrees Installation Guide
Installation Directions
-
Switch off mains power supply
-
Connect Dimmable Driver to mains voltage cable (L, N) Do not connect downlight to driver if driver is live.
Inrush current from live driver will cause instant downlight failure. Do not switch secondary side. -
Carefully install downlight intopre-cut 83mm hole.
-
Turn on mains power and switch on lighting circuit.
Approved Clearances
Note: Omm required but 25mm always recommended for optimum product
lifespan through effective heat dissipation.
Example 1:
Omm Approved Height Clearance. Building element abutting rear, insulation
abutting sides of fitting.
Example 2:
Omm Approved Side Clearance. Building element abutting ign side of fitting,
insulation abutting and covering fitting.
Driver is designed to be covered and abutted with IC / IC-F approved
insulation.
CLASSIFICATION SHEET IC
Manufacturer / Supplier | Halcyon Lighting Ltd |
---|---|
Product Code | R827 |
Product Type | LED Recessed Luminaire |
Primary Voltage | 220-240V~50/60Hz |
Secondary Voltage | 350mA Constant Current |
Wattage | 9W |
Ingress Protection Rating | IP44 |
Classification
IC – building insulation that can safely be continuously exposed to 90°C allowed to abut and cover the luminaire.
In the vicinity of the recessed luminaire, use an insulation product that:
(a) Maintains its dimensions and structural integrity when exposed to a
temperature of 90°C; and
(b) Withstands a 30-second needle flame test carried out in accordance
with AS/NZS 60695. 11.5 with the flame applied to all surfaces of the sample.
Rear of fitting may abut structural members and building elements.
Do not install through or directly into joist, beam, rafter or ceiling batten.
Side Clearance from heatsink to building element (e.g. timber, joist or
batten): SCB: 0mm
Height Clearance from heatsink to building element (e.g. timber, joist or
batten): HCB: 0mm
Minimum insulation clearance to building element: MIC: Omm
Recessed luminaires and their associated equipment may pose a risk of fire or damage to property if not installed and maintained correctly. Halcyon recommends a clearance of 25mm to building elements for optimum lifespan.
Halcyon IC rated luminaires are completely safe to install in sarked timber
ceiling linings.
Halcyon accepts no responsibility if the timber used is not treated correctly
and dries out, crack or warps over time due to the constant low heat from the
aforementioned “IC Rated” LED recessed lighting.
This data sheet contains information necessary to ensure compliance with the New Zealand Electrical Code of Practice for Installation and Maintenance of Recessed Luminaires and Associated Equipment AS/NZS 60598.2.2:2001
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>