RISK OF FIRE – Required clearance from structural members and building
elements
Side Clearance to building element (eg timber, joist or Batten) (SCB): 50mm
Height Clearance to building element (eg timber, joist or Batten) (HCB): 50mm
Recessed Luminaire Classification:
@700mA(CA1 35)
CA135 – building insulation that can sately be continuously exposed to
135°C allowed to abut the luminaire. Definition: Can abut the luminaire but
NOT cover.
RISK OF FIRE – Required clearance from structural members and building
elements
Side Clearance to building element (eg timber, joist or Batten) (SCB): 50mm
Height Clearance to building element (eg timber, joist or Batten) (HCB): 50mm
Recessed Luminaire Classification: @1 050mA(NON IC)
NON-IC – A luminaire shall under no circumstances be covered or abutted
with building insulation. Definition: Building insulation must not cover or
come into contact with any part of the luminaire. For indoor use only. If the
external flexible cable or cord of this luminaire is damaged, it shall be
exclusively replaced by the manufacturer or his service agent or a similar
qualified person in order to avoid a hazard.
The light source of this luminaire is not replaceable; when the light source
reaches its end of life the whole luminaire shall be replaced This luminaire
must be installed by a qualified Registered Electrician to prevent damage to
the luminaire and maintain electrical safety.
The light source of this luminaire is not replaceable; when the light source
reaches its end of life the whole luminaire shall be replaced DO NOT INSTALL
THROUGH JOIST, BEAM, RAFTER OR CEILING BATTEN
Note: Side/Height Clearance is measured from Heat Sink
CLASSIFICATION SHEET
Manufacturer / Supplier | Halcyon Lighting Ltd |
---|---|
Product Code | R743 |
Product Type | LED Recessed Luminaire |
Secondary Voltage | 700mA (CA135) or 1050mA (NON IC) Constant Current DC |
Wattage | 33W (@700mA) or 48.5W (@1050mA) |
Ingress Protection Rating | IP54 |
DO NOT INSTALL THROUGH JOIST, BEAM, RAFTER OR CEILING BATTEN.
R743 @ 700mA
Classification| | CA 135 — Building insulation that can safely be continuously
exposed to 135°C allowed to abut the luminaire. Definition: Can abut the
luminaire but NOT cover.
---|---|---
Side Clearance from heatsink to building element (e.g. timber, joist or
batten)| SCB: 50mm
---|---
Height Clearance from heatsink to building element (e.g. timber, joist or
batten)| HCB: 50mm
R743 @ 1050mA
Classification| | NON IC — A luminaire shall under no circumstances be covered
or abutted with building insulation.
---|---|---
Side Clearance from heatsink to building element (e.g. timber, joist or
batten)| SCB: 50mm
---|---
Height Clearance from heatsink to building element (e.g. timber, joist or
batten)| HCB: 50mm
Caution: Recessed luminaires and their associated equipment may pose a
risk of fire or damage to property if not installed and maintained correctly.
Halcyon Non IC rated luminaires are completely safe to install in sarked
timber ceiling linings with a gauge of less than 20mm. Halcyon accepts no
responsibility if the timber used is not treated correctly and dries out,
crack or warps over time due to the constant low heat from the aforementioned
“Non IC Rated” LED recessed lighting.
This data sheet contains information necessary to ensure compliance with the
New Zealand Electrical Code of Practice for Installation and Maintenance of
Recessed Luminaires and Associated Equipment AS/NZS 60598.2.2:2001