CrosbyIP IPH10(E) Lifting Clamp User Manual
- June 10, 2024
- CrosbyIP
Table of Contents
CrosbyIP IPH10(E) Lifting Clamp
IPH10(E)
Horizontal lifting
© The Crosby Group LLC. Nothing from this original user instructions publication may, in any way whatever, be replicated or published without prior written permission from The Crosby Group LLC.
General
You have chosen a CrosbyIP lifting clamp.
CrosbyIP lifting clamps are the most reliable lifting clamps available. But using reliable tools does not automatically mean that practices are reliable. The people who work with clamps play an equally important role in reliable lifting. Ensure that everyone who works with CrosbyIP lifting clamps has been instructed in the proper application of the clamps.
CrosbyIP provides a 10 year warranty for its clamps. To keep CrosbyIP lifting clamps in optimum condition and keep warranty, regular maintenance is important. Preventive maintenance and repair shall be carried by a repairer authorized by CrosbyIP. In order to benefit from this warranty programme and for more details on maintenance procedures, please consult www.thecrosbygroup.com/resources/crosbyip-10-year- guarantee for more information.
Please read and understand these instructions before using the lifting clamp.
Check when placing the clamp that slings are not twisted.
It is not permitted to stay in the danger zone of the load.
No changes may be made to CrosbyIP clamps. Never straighten, attempt to bend
or heat treat parts.
Clamps suited for stainless steel, must be used only for handling stainless
steel, to avoid contact corrosion.
Safety precautions
- Proper instruction for the personnel is of vital importance. This will contribute to maximum reliability in the working environment.
- IPH10(E) clamps may be used per pair, per three clamps or with several pairs simultaneously for the lifting of plates.
- Ensure that each clamp receives its proportionate share of the load. When using two clamps or more, a spreader beam is recommended.
- Hardness: With the standard clamps it is possible to lift steel with a surface hardness of 363 HV10. For harder steel types contact your CrosbyIP Customer Service Centre.
- Contact your CrosbyIP Customer Service Centre before using this clamp for plates and constructions that have a radius.
- Temperature: the operating temperature is between –40 ºC (–40 ºF) and 100 ºC (212 ºF). For other temperatures contact your CrosbyIP Customer Service Centre.
- There are restrictions for operation in special atmospheres (e.g. high humidity, explosive, saline, acid, alkaline).
- Loads: For proper application of the clamp consult the load diagrams 1.
- Ensure that all attachments between lifting eye and crane are properly fitted, secured and coupled.
- When using endless reeved chain the maximum admissible top angle is 60º and the W.L.L. 50% of the maximum admissible W.L.L.
- Several plates may be transported or lifted per lift.
- The IPH10(E) clamps may not be used for sagging plates.
- During the descent of the load there may be no obstacles present under the load that can impede the load causing a clamp to be unloaded. The clamps may only release the load when it is in a stable position.
- During the tensioning of cables or chains the clamps must remain properly positioned.
- Remark: when handling the load, one should ensure that the load and or clamp does not encounter obstacles which could release the load on the clamps prematurely.
- A clamp is a device that must be clean when used. Dirt has an adverse effect on the operation and also on the reliability of the clamp. When cleaning the clamp care should be taken to ensuring that moving parts are lubricated and the gripping surfaces are clean. Regular cleaning will enhance the life and reliability of the clamps.
Inspections protocols
Prior to every application of the clamp it is important the clamp operator inspects the clamp for proper functioning. Attention must be paid to the following (see illustration(s) 2 for part reference):
- Ensure that the plate surface with which the clamp is to come into contact is free of scale, grease, oil, paint, water, ice, moisture, dirt and coatings that might impede the contact of the gripping surface with the plate.
- Inspect camsegment (B) for wear and defects. The teeth must be sharp and free of dirt.
- Check the body (N) and the jaw for damage, cracks or deformation (this may indicate overloading). The clamp must open and close properly (when the operation of the clamp is stiff or heavy, it should be removed from operation for inspection).
- Check the camsegment shaft (G) for readily detectable wear and/or damage (check also the roll pin (P) which locks the camsegment shaft).
- Check whether the W.L.L. and the jaw opening stamped on the body corresponds with the load to be lifted. When this is no longer readable, remove the clamp from operation.
- Check the operation of the tension spring (M) (if applied). The clamp is not kept in place when there is no pretension.
- Check if magnets (Y) (if applied) are damaged or missing because this decreases the holding force.
- Check the operation of the torsion spring (M) (if applied). If damaged, the camsegment is not kept in position and can cause hooking of the chain on the back of the clamp.
- Ensure that the surface of the magnets (if applied) and bottom plate are free of dirt and scale because this can cause damage of the magnets and decrease of the holding force.
The camsegment is the most critical part in the clamp and requires extra
attention during inspection. Ensure in any event for good light during
inspection. Observe the following rules during every inspection:
Camsegment: Reject when the sharpness of one tooth is damaged or worn for
50% or more.
This type of clamp can prone to deformation of the hole in which the chain (D-shackle) impinges, resulting in the hole becoming oval. When that is the case the clamp should be removed from service immediately. Deformation in this part is mainly due to exceeding of the maximum side loading angle of 15°. The maximum loading angles are displayed in the loading diagrams 1.
On the inside of the front cover illustrations have been included of damaged and worn (rejected) pivots and camsegments:
- One complete tooth not sharp and one damaged
- Two teeth damaged for 50%
- One tooth damaged for 100% and one tooth damaged for 50%
- Two rings damaged for 100%
- Interior ring damaged for 100%
These areas of damage, precisely as wear, are not covered by the warranty.
In most cases however the areas of damage are much less extensive. In doubtful
cases an authorised repairer should assess the clamp.
How to operate the clamp
PH10(E) lifting clamps are suitable for horizontal lifting and transport of non-sagging steel plates, beams and structures. The IPH10 clamps are kept in place after positioning by pretension (0,5 & 1) or by magnets (2, 3, 4, 5, 6, 9 & 12 IPH10(J) models).
DO NOT attach chains or cables on the handle!
See illustrations 3 – 5 for part reference.
A reliable clamp, a secure basis for lifting
10 Year warranty preventive maintenance procedure:
Parts should be replaced only when they no longer meet our standards.
10 Year warranty repair procedure:
During every repair service the most critical parts, being camsegment will be replaced and, when necessary, any rejected parts.
For clamps with a Working Load Limit (W.L.L.) of 4,5 ton or more, parts will be replaced only when they no longer meet our standards.
Please consult www.thecrosbygroup.com/resources/crosbyip-10-year- guarantee for more information on maintenance procedures.
Maintenance without 10 year warranty: Annually clamps are subjected to
inspection and parts will be replaced only when they no longer meet our
standards.
CrosbyIP authorised repairer
Copyright © 2021 The Crosby Group LLC. All Rights Reserved.
Explanation test certificate
EU Declaration of Conformity: We hereby declare that the equipment
described at the front page conforms to the relevant fundamental safety and
health requirements of the appropriate EU Directives, both in its basic design
and construction as well as in the version marketed by us. This declaration
will cease to be valid if any modifications are made to the machine without
our express approval.
Relevant EU Directives: EU Machinery Directive (2006/42/CE) Applied
standards: EN 13155 and ASME B30.20
UK Declaration of Conformity: We hereby declare that the equipment
described at the front page meets the essential safety requirements of the
Supply of Machinery (Safety) Regulations 2008 and section 6 of the Health and
Safety At work Etc. Act. 1974. This declaration will cease to be valid if any
modifications are made to the machine without our express approval.
Applied standards: EN 13155 and ASME B30.20
Manufacturer
CrosbyIP Lifting Clamps – Inter Product BV
Celsiusstraat 51
6716 BZ Ede
The Netherlands
Ede, 25-1-2021 W. Fabricius
Manufacturer:
CrosbyIP Lifting Clamps – Inter Product BV
Celsiusstraat 51
6716 BZ Ede
The Netherlands
WARNING
- Loads may disengage from clamp if proper procedures are not followed.
- A falling load may cause serious injury or death.
- The clamp shall not be loaded in excess of its rated load or handle any load for which it is not designed. Read instructions in user manual to determine minimum load permitted and proper load thickness.
- Never operate a damaged or malfunctioning clamp, or a clamp with missing parts.
- Clamp not to be used for personnel hoisting.
- Prohibition of handling above persons.
- Do not leave suspended loads unattended.
- Operator and other personnel shall stay clear of the load.
- Do not lift loads higher than necessary.
- Do not make alterations or modifications to clamp.
- Do not remove or obscure warning labels.
- See ANSI/ASME B30.20 BELOW-THE-HOOK LIFTING DEVICES for additional information.
- Read, understand, and follow these instructions and the product safety information in user manual before using clamp.
Customer Service Centers
BELGIUM
Industriepark Zone B n°26
2220 Heist-op-den-Berg
P: (+32) (0)15 75 71 25
F: (+32) (0)15 75 37 64
salesbelgium@thecrosbygroup.com
U.S.A
P.O. Box 3128
Tulsa, OK 74101
P: (+1) (918) 834 46 11
F: (+1) (918) 832 09 40
customerservice@thecrosbygroup.com
CANADA
1195 Courtney Park Drive East
Mississauga, Ontario
Canada L5T 1R1
P: (+1) 877 462 7672
F: (+1) 877 260 5106
customerservice@thecrosbygroup.com
References
- The Crosby Group - Material Handling Solutions
- The Crosby Group - Material Handling Solutions
- The Crosby Group Regional Contacts - Material Handing Products
- Resources & Tools – The Crosby Group
- Crosby® 1210 Forged Round Reverse Eye Hooks - The Crosby Group
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>