HALCYON R730 Glare Retrospec Design Standard Installation Guide
- June 10, 2024
- HALCYON
Table of Contents
HALCYON R730 Glare Retrospec Design Standard
INSTALLATION
Installation Directions
- Switch off the mains power supply
- Connect Dimmable Driver to mains voltage cable (L, N) Do not connect the downlight to the driver if the driver is live. Inrush current from live driver will cause instant downlight failure. Do not switch the secondary side.
- Carefully install downlight into Precut 72-82mm hole.
- Turn on the mains power and switch on the lighting circuit.
Approved Clearances
Note: Omm is required but 25mm is always recommended for optimum product lifespan through effective heat dissipation.
Example 1:
Omm Approved Height Clearance. Building element abutting rear, insulation
abutting sides of fitting.
Example 2:
Omm Approved Side Clearance. Building element abutting side of the fitting,
insulation abutting, and covering fitting.
The driver is designed to be covered and abutted with IC/IC-F/IC-4-approved insulation.
CLASSIFICATION SHEET
In the vicinity of the recessed luminaire, use an insulation product that:
- Maintains its dimensions and structural integrity when exposed to a temperature of 90°C; and
- Withstands a 30-second needle flame test carried out in accordance with AS/NZS 60695.11.5 with the flame applied to all surfaces of the sample
The rear of the fitting may abut structural members and building
elements.
Do not install through or directly into the joist, beam, rafter, or ceiling
batten.
Recessed luminaires and their associated equipment may pose a risk of fire or damage to property if not installed and maintained correctly. Halcyon recommends a clearance of 25mm to building elements for optimum lifespan.
Halcyon IC-F-rated luminaires are completely safe to install in sarked
timber ceiling linings
Halcyon accepts no responsibility if the timber used is not treated correctly
and dries out, cracks,s or warps over time due to the constant low heat from
the aforementioned “IC-F Rated” LED recessed lighting.
This data sheet contains the information necessary to ensure compliance with the New Zealand Electrical Code of Practice for Installation and Maintenance of Recessed Luminaires and Associated Equipment AS/NZS 60598.2.2:2001