2 OPERATING INSTRUCTION
LED CEILING LAMP
LED363 LED364 LED365

APPLICATION

This is indoor LED ceiling lamp.

  • Houses
  • Offices
  • Retail
  • Schools
  • Hotels
  • Hospitals

MAIN TECHNICAL DATA

Input: AC 220-240V 50/60Hz
Light source: LED SMD2835
Working temperature: -20°C–+50°C -20°C–+40°C (with sensor)  HALCYON LED363
LED Ceiling Lamp - overview

CAUTION

  1. The product must be installed by professional technicians and power supply must be cut off before installation.
  2. The installation wiring must be 2x 1.0mm? at least and wired in accordance with the latest IEE electrical regulations or the national requirements.(Recommend type of cable is HO3VV-F)
  3. Do not touch the electronic circuit and its components.
  4. Don’t touch LED while installing o r maintaining.
  5. The LED light source cannot be replaced.

DESCRIPTION OF MICROWAVE SENSOR

  • Detection zone Max.(D x H): 14m x 6m
  • Detection sensitivity: 25%- 100%, adjustable
  • Hold time: 5sec-30min, adjustable
  • Daylight 1 : 5-15Lux, adjustable or disable
  • Daylight 2: 35-150Lux, adjustable or disable
  • Stand-by Period : Osec-+-,adjustable (Refer to “Low light”)
  • Mounting height: 6m Max.
  • Motion detection: 0.3~3m/s
  • Detection angle: 150°(wall installation), 360°(ceiling installation)

HALCYON LED363 LED Ceiling Lamp - sensor Default sensor factory settings:
Detection Area: 100%
Hold Time: 1min
Stand-by Period: 10min (@20%)
Mode: Mode 1
Daylight 1: Disable
Daylight 2 : Disable

PARAMETER SETTING OF MICROWAVE SENSOR

HALCYON LED363 LED Ceiling Lamp - sensor 1

Detection Area
This determines the effective range of the motion detector and is set by DIP switches at the sensor itself, refer to figure. Note that reducing the sensitivity will also narrow the detection range.

| 1| 2|
---|---|---|---
I| ON| ON| 100%
II| | ON| 75%
III| ON| | 50%
IV| | | 25%

Stand-by Period
This refers to “Low light period” , when it is set to +°°, the luminaire gives permanent low light when no movement detected.it is set with DIP switches at the sensor itself, refer to figure.

| 6| 7| 8|
---|---|---|---|---
I| ON| ON| ON| Os
II| | ON| ON| 10min
III| ON| | ON| 20min
IV| | | ON| 30min
V| ON| ON| | 60min
V I|   | | | +00

Daylight
Under Mode 1:
When the daylight level drops below the set value, the microwave sensor becomes active.
When the daylight level exceeds the set value, the light will be always off.
The “disable” setting disables the daylight sensor.
Under Mode 2:
When the daylight level drops below the LUX value, the fitting will tum on at the standby level and the microwave sensor becomes active.
The “disable” setting disables the daylight sensor.

| 1| 2|
---|---|---|---
I| ON| ON| Disable
II| | ON| 15 LUX
III| ON| | 10 LUX
IV| | | 5 LUX

Hold Time
This determines the time the fitting remains at 100% level on motion detection and is set with DIP switches at the sensor itself, refer to figure. The walk test setting is useful when installing the fitting to establish correct operation and range.

| 3| 4| 5|
---|---|---|---|---
I| ON| ON| ON| 5s
II| | ON| ON| 30s
III| ON| | ON| 1min
IV| | | ON| 5min
V| ON| ON| | 15min
V I|   | | | 30mm

Daylight Sensor Mode
Mode1: Normal light-control.
Mode2: Photocell prioritised, meaning the luminaire is off when ambient brightness accesses the set threshold, and automatically on to a low light level when ambient brightness is lower than the set threshold, and tums to high light level when it detects a movement. See page 4 for more details.

| 6|
---|---|---
I| ON| Model 1
II| | Model 2

Daylight 2
This is only applicable under mode2, refers to the threshold when the luminaire should turn off (from low light status) at the relevant sunlight lux.

| 3| 4| 5|
---|---|---|---|---
I| ON| ON| ON| Disable
II| | ON| ON| 150 LUX
III| ON| | ON| 100 LUX
IV| | | ON| 75 LUX
V| ON| ON| | 50 LUX
V I|   | | | 35 LUX

DAYLIGHT SENSOR MODE EXPLAINED

****Daylight Sensor Mode

| 6|
---|---|---
I| ON| Model 1
II| | Model 2

Mode 1: “Normal” Light Control
When the ambient light levels drop below the set lux value the motion sensor activates but luminaire remains off. If motion i s detected the luminaire will tum on to 100% but
only if the ambient light level is less than the set lux value.
Example, if sensor i s set to:
“Mode 1 : Daylight 1 @ 15 lux” the following rules apply.

  1. When ambient light is greater than 15lux , luminaire will remain in an off state.
  2. When ambient light drops below 15lux , luminaire will switch to 100% output for set period of time (hold time) when motion is sensed.
  3. If ambient light levels retum to greater than 15 lux, luminaire will turn off (once hold time has expired) and will not turn on when motion is sensed.

Mode 2 : “Photocell Prioritised” Light Control
When the ambient light levels drop below the set lux value the lumi naire automatically tumson to 20% low light output / standby mode. If motion is detected the luminaire will turn on to 100%. When in Mode 2 + Daylight 1, use the Daylight 2 settings to determine when luminaire should fully tum off from low light mode.
Example, if sensor is set to:
“Mode 2: Daylight 1 @ 15 lux + Daylight 2 @ 100 lux” the following rules apply.

  1. When ambient light is greater than 15 lux , luminaire will remain in an off state.
  2. When ambient light drops below 15lux , luminaire will turn on to low light mode at 20% brightness and will switch to 100% output for set period of time (hold time) when motion is sensed.
  3. When ambient light levels retum to greater than 100 lux (daylight 2 setting) luminaire will exit low light mode and tum off regardless of motion (until ambient light drops below 15 lux again)

TECHNICAL INFORMATION

Code| Input Voltage| LED Type| Input Power| Lumen| Sensor| Dimension
---|---|---|---|---|---|---
LED363 W34A| AC 220-240V 50/60Hz| SMD2835| QWI4.5W| 1050/560LM| —| Ø260x85mm
LED363 W34AS| AC 220-240V 50/60Hz| SMD2835| 10W/5.5W| 1050/560LM| Yes| Ø 260x85mm
LED364.W34A| AC 220-240V50/60Hz| SMD2835| 14W/9W/6.5W| 1590/1030/730 LM| —| Ø 340x100mm
LED364 W34AS| AC 220-240V 50/60Hz| SMD2835| 15W/10W/7.5W| 1590/1030/730LM| Yes| Ø 340x100mm
LED365 W34A| AC. 220-240V 50/60Hz| SMD2835| 24W/6W/12W| 3100/2100/1570LM| —| Ø 400x107mm
LED365 W34AS| AC 220-240V50/60Hz| SMD2835| 25W/7W/13W| 3100/2100/1570LM| Yes| Ø 400x107mm

MASTER/SLAVE FUNCTION

HALCYON LED363 LED Ceiling Lamp - Function

MOUNTING

  1. Disassemble the diffuser and LED panel .
  2. Pull in the power cord through the gasket.
  3. Fix the base on the surface with screws.
  4. Connect the power cord on the terminal correctly.
  5. Assemble the LED panel and diffuser.

HALCYON LED363 LED Ceiling Lamp - Mounting Cable connection

HALCYON LED363 LED Ceiling Lamp - cable connection

OPTIONAL BRIGHTNESS

Different brightness settings by DIP switches on LED plates.HALCYON LED363
LED Ceiling Lamp - brightness 1 OPTIONAL COLOUR TEMPERATURE
Different colour temperature settings by DIP switches on LED plates.

HALCYON LED363 LED Ceiling Lamp - plate

MAINTENANCE

  1. Cut off the mains power first.
  2. Don’t touch LED while maintaining or cleaning.
  3. Don’t use chemical reagent to clean lamp.

HALCYON LED363 LED Ceiling Lamp - Maintenace

  1. Open the diffuser

  2. Unlock the LED plate

  3. Remove the baseHALCYON LED363 LED Ceiling Lamp - base

  4. Disconnect the male-female connector

  5. Dismantle all these partsHALCYON LED363 LED Ceiling Lamp - parts

  6. The control gear and the light sourceHALCYON LED363 LED Ceiling Lamp - contolar

Replaceable (LED only) light source by a professional
HALCYON LED363 LED Ceiling Lamp - Mounting 2Replaceable control gear by a professional

This product contains a light source of energy efficiency class D
Please note, the control gear in this product is not intended to operate in no-load mode Environmental protection: Waste electrical products should not be disposed of with
household waste. Please recycle where facilities exist. Check with your local authority or retailer for recycling advice.

HALCYON logoHalcyon Lighting Ltd
10 Basalt Place, East Tamaki, Auckland 2013
Ph: (0064 9) 273 9177
Email: sales@halcyon.co.nz
Website: www.halcyonlights.co.nz