Bove Technology B6 Lite VW Ultrasonic Water Meter User Guide

June 10, 2024
Bove Technology

Bove-Technology-BECO-X-Ultrasonic-Water-Meter-logo

Bove Technology B6 Lite VW Ultrasonic Water Meter

Product Information

The B6 Lite VW Ultrasonic Water Meter is a high-precision water meter designed and manufactured by BOVE TECHNOLOGY. It uses ultrasonic technology to accurately measure the flow rate of water and has a compact design that makes it easy to install and use.

The meter’s performance and functions are continuously improved, so the manual may be subject to change without prior notice. BOVE TECHNOLOGY is committed to ensuring the accuracy of the manual’s contents, and customers can contact them if they have any questions or find any errors. Copying or reproducing any part of the manual is strictly prohibited.

The B6 Lite VW Ultrasonic Water Meter is manufactured by Bove Intelligent Technology Co., Ltd. in Zhejiang, China. The company can be contacted via phone, fax, email or website.

Product Usage Instructions

Before installing the meter, carefully read the Installation & User Guide provided with the meter. The guide contains important instructions for installing and using the meter correctly.

Here are some general usage instructions:

  1. Ensure that the meter is properly installed before use.
    Improper installation may cause inaccurate readings.

  2. Turn on the power supply to the meter.

  3. The meter will automatically display the current flow rate and total water consumption.

  4. To reset the total water consumption, press and hold the reset button until the display shows “00000”.

  5. Regularly check the meter for any signs of damage or wear and tear. This will help ensure its accuracy and longevity.

  6. If you encounter any issues or have questions about using the meter, refer to the Installation & User Guide or contact BOVE TECHNOLOGY for assistance.

Following these instructions will help ensure the accurate and reliable operation of the B6 Lite VW Ultrasonic Water Meter.

Thank you for choosing our products

  • The contents of this manual are subject to change without prior notice as a result of continuing improvements to the meter’s performance and functions.
  • Every effort has been made in the preparation of this manual to ensure the accuracy of its contents. However, should you have any questions or find any errors, please contact BOVE TECHNOLOGY.
  • Copying or reproducing all or any part of the contents of this manual without the permission of BOVE TECHNOLOGY is strictly prohibited.

Bove Intelligent Technology Co., Ltd
Add: Level 5, Building 5, No. 36,
Changsheng South Road, Jiaxing, Zhejiang, China, 314000
Tel: +86 573 83525916
Fax: +86 573 83525912
Email: bove@bovetech.com
www.bovetech.com

General Information

Please note that the following installation conditions must be obeyed:
Pressure Requirement: MAP16.
Environmental Class: E1, M1
Installation requirement : There must be a distance of minimum 25 cm between signal cables and other installations

Note: Seal or any safety marks on the meter must not be damaged or removed, and doing so will void the warranty and calibration of the meter.

Technical Specification

Flow Sensor
The flow sensor is a device used to measure the velocity of flow by using the principle of ultrasound. It can measure the average velocity along the path of an emitted beam of ultrasound by averaging the difference in measured transit time between the pulses of ultrasound propagating into and against the direction of the flow. The flow measurement is based on an acoustic wave time of flight principle. The flow meter body is equipped with 2 ultrasonic transducers facing 2 acoustic reflectors.

Flow sensor specification:

Manufacturer Bove
Type B6LiteVW
Accuracy class Class2
MAP 16bar
Max Pressure loss at Q3 ≤63kPa
Max admissible temperature 50°C
Limits of temperature (Θmin and Θmax) 0.1-30°C,0.1-50°C
Installation requirements U5/D3(recommend U10/D5)
Basic mounting orientation and other specified orientations

Horizontal/Vertical
Output signal for testing| Analog signal 1 Mhz
power supply| Lithium Battery
Current used| Average2 0uA,Peak4mA
Climatic and mechanical class| B
Electromagnetic class| E1
Mechanical class| M1

Calculator
The calculator is a device that calculates the flow volume consumed based on signals from flow sensor. It’s also the control, display and data store part for the meter.

Calculator specification:

Manufacturer Bove
Climatic and mechanical class B
Electromagnetic Class E1
Mechanical Class M1
Display unit m3,L
Physical dimensions Length: 110mm (DN15)-130mm(DN20),

Width: 93mm, Height:82mm
Battery power supply requirements| Seepart:4Powersupply
Pulse input device class| N/A
Max permissible flow sensor signal(Pulse rate)| N/A
Output signal for normal operation| M-Bus,Infrared,RS485,LoRaWAN
Pulse output device class| N/A
Output signal for testing| M-Bus,Infrared,RS485,LoRaWAN
Liquid if other than water| N/A

Completer meter

Manufacturer Bove

Flow Measurement
Type| DN (mm)| Flow Rate (m3/h)| Dimensions (mm)| Connection
Q1| Q2| Q3| Q4| Length| Width| Height| ―――
B6LiteVW-15| 15| 0.016| 0.0256| 2.5| 3.125| 110| 93| 82| G3/4″
B6LiteVW-20| 20| 0.025| 0.04| 4| 5.0| 130| 93| 82| G1′
B6LiteVW-25| 25| 0.039| 0.063| 6.3| 7.875| 150| 93| 92| G11/4′
Pressure Loss △P| ≤63KPa
MAP| 1.6MPa
Water temperature range| 0.1to30°C,0.1to50°C
Q3/Q1| 160:1
Accuracy| Class2
Maximum permissible error in upper flow rates range Q2 £ Q £ Q4| ±2%(atΘ≤30°C)
±3%(atΘ>30°C)
Maximum permissible error in lower flow rates range Q1 £ Q < Q2| ±5%
Scale interval(m3)| 0.001
---|---
Capacity of calculator| 99999,999
Type of liquid| Water
Installation requirements| U5/D3(recommendU10/D5)
Basic mounting orientation and other specified orientations| Horizontal/Vertical
Display & Indication
Display unit options| m3,L
Display LCD| 8-digit
Volume| 0.001m3
Time to LCD off| 3min.
Environmental Requirement
Environmental Class| E1,M1
Ambient temperature| 5~55°C(Indoor and non-condensing)
Storage temperature| -20~60°C
Protection Class| IP65/IP68
Data history| 24month
Interface & Communication
Output signal for normal operation| M-Bus(Optional)
RS485(Optional)
Infrared
Lora WAN/ Sig fox (Optional)
Output display/signal for testing| M-Bus, Infrared
Power Supply
Battery| Lith3.Two6ViumBattery
Battery Life| ≥6Years
24V DC| External supply for special version (Optional)
Mechanical Specification
Top cover| ABS
Bottom cover| ABS
Flow Body| PPA
Flow Pipe| PPA

Data Storage

  1. Accumulated flow for the current month.
    Note: 1 will be registered at 00:00 on the balance day, and the calculator stores the data of last 24 months.

  2. Flow correction coefficient (Only stored when manufacturing).

  3. Meter ID.

  4. Balance Date.
    Note: 2 to 4 are upgraded as per each command.

  5. Accumulated flow volume.

Physical dimensions

Bove-Technology-B6-Lite-VW-Ultrasonic-Water-Meter-01

Installation

Requirements for installation environment
B6 Lite VW series ultrasonic water meter has been designed for indoor installation in non-condensing environments with ambient temperatures from 5~55°C.

The meter must not be under any mechanical stress when installed in the pipe.
The meter must be protected against pressure shocks in the pipe.
Protection class IP68 allows long-term submergence, provided that all cable unions have been correctly mounted and that the plastic cover has been properly fastened.

Make sure the meter is installed sufficiently far away from possible sources of electromagnetic interference (switches, electric motors, fluorescent lamps, etc.).

All control cables must be drawn separately and not parallel to e.g. power cables or other cables with the risk of inducing electromagnetic interference. There must be a distance of min. 25cm between signal cables and other installations.
If two or more meters are to be installed shall be in parallel, the axis- center distance between two meters shall be at least 135mm minimum.

Before Installation
Prior to installation of the flow sensor, the pipe shall be thoroughly flushed out, and any dirty, stone alike items must be removed from the pipe. Cavitation in the system must be avoided. If a risk of frost exists, empty the system and, if necessary, remove the meter. If the water is soiled, fit the strainer in the pipe before the meter.

Mounting of Flow Sensor
Consider the dimensions of the water meter, and the distance with surroundings, minimum 3 cm free space.
Straight sections of at least 5×DN before and 3×DN (recommend U10/D5) after the meter are recommended, to homogenize the temperatures of water.

The meter is to be installed so that the direction of the arrow on the meter housing corresponds to the direction of flow. Avoid the collection of air bubbles in the meter during the installation process. Install the flow sensor into horizontal or up streaming pipelines.

Do not install at highest point of piping to avoid air inside the flow sensor. The flow sensor must NOT be installed in the positions where swirling flow exists (swirling flow is normally caused by bending pipe), or pulsatile flow exists (pulsatile flow is normally caused by pump, therefore the flow sensor must be installed as far as possible from pump and must not be installed on the outlet of pump) or air may build up.

Bove-Technology-B6-Lite-VW-Ultrasonic-Water-Meter-02

  • A: Recommended flow sensor position
  • B: Recommended flow sensor position
  • C: Unacceptable flow sensor position
  • D: Unacceptable flow sensor position in open system; acceptable in closed system.

Mounting Step

  • Step 1: Flush the piping system thoroughly before mounting the meter.
  • Step 2: Sufficient distance.5×DN straight pipe in upstream and 3×DN straight pipe in downstream. (DN: Diameter), (recommend U10/D5)
  • Step 3: The specific seal gasket and connector only supplied by Bove Technology.
  • Step 4: On the two sides of the meter, there should be one filter (if the water is soiled) and two shut-off valves.
  • Step 5: After finishing the above operations, seal the meter only if the sealing has not been done before delivery from factory.

Installation of non-return value
The meter can be supplied with a non-return valve (if required) on request. The non-return valve must be installed on the water inlet end of meter when installing.

After the installation
The tightness must be proved by pressurizing with cold water, slowly filling the pipe on completion of the installation.
Open the shut-off valves carefully and check installation for leakage. While the piping system is operating, check whether the volume display correctly and the temperatures display corresponding with the actual temperatures (see the display information).
When the response thresholds are exceeded and the flow rate is positive, the volume is summated.
Make the segment test, in order to displays all display segments for test purposes.
The operating hours are counted from initial connection of the battery.
The date is incremented daily. As a standard the meter is delivered with the local time, or destination time if required.

Power supply

B6 Lite VW Series can be fitted with one or two ER18505 with operating time of 6/10years respectively.

Brand EVE
Type Lithium Battery
Model No. ER18505
Rated capacity 4000mAh
Rated voltage 3.6V
Max recommended continuous operating current 130mA
Max pulse current 180mA
Reference weight 28g
Max dimension 18.7×50.5mm
Operating temperature -55°C ~ +85°C

Interface & Communication

IrDA
B6 Lite VW Series are all equipped with an optical interface IrDA to IEC62056-21 as a standard. In addition, one of the following options can be ordered for remote output.

M-Bus (Optional)

  • Cable: connected with galvanic isolation
  • Voltage: 50V max.
  • Current: M-Bus loads
  • Addressing: primary or secondary

Note: A higher frequency is not allowed and may result in meter malfunction!

Data transmission in the compatibility mode (= standard, one data frame) or in the full mode (3 data frames) possible.

If the meter is equipped with “M-Bus”, it is delivered with a two wire cable, which can be lengthened with a cable 2 x 0.75mm2 (put a distributing box). Pay attention to the proper polarity in case of the pulse output. If the meter is read out via M-bus, the allowed mean frequency of reading must not be exceeded. Any more reading is not allowed and may result in a damage to meter.

The M-Bus or pulse variant of the meter is supplied with a 2-wire cable with wire end ferrules.

Version/Color Pulse M-Bus (2-wire)
Red Pulse M-Bus
Black GND M-Bus

Pulse Output (Optional)

  • Pulse output for heat or volume, with 0.6m cable connected, with galvanic isolation.
  • Pulse significance: 1 pulse per 100 liter
  • Pulse length: 100 ms (Programmable)
  • Heat / Volume: specify in order or change with service-software .
  • Voltage: max. 30 V
  • Current: max. 30 mA
  • Classification OC (acc. to EN 1434-2)
  • Voltage drop: ca. 1.3V at 20 mA

RS-485(Optional)

  • Cable: connected with four-core cable
  • Voltage: 5-24V.
Version/Color RS-485
Red VCC
Black GND
Yellow A
Green B

Sig fox (Optional)

RCZ Serial RCZ1 RCZ2/4
EIRP/dBm (max) 16 24
Data transmission Configurable

Lora WAN (Optional)

ISM Band EU433 EU868 IN865 US915
Class Class A
Network Access Mode OTAA or ABP
Transmitting Power 12.15
dBm(max) 16
dBm(max) 20
dBm(max) 20dBm(max)
Data transmission Each6hasdefault

Operation & Display

B6 Lite VW Series is fitted with an easily readable LCD, including 8 digits, measuring units and information field.
The display automatically returns to LCD sleep mode 3 minutes after the latest activation of the push button. When power on, the meter will reset and displays full screen to allow users to detect if there is any problem with the LCD.

Bove-Technology-B97-VPW-Prepaid-Ultrasonic-Water-
Meter-04

Fig. LCD Display

No. Icon Name Meaning
1 Calibration mode Under calibration
2 Low battery warming User is reminded to replace the battery with a new

one.
3| | Error warning| Warnings for error
4| | Communication type| M-Bus communication
5| | Pipe state| Blink means empty pipe
6| | Credit alarm| Prepaid mode only
7| | Button indication| Button detected once appear
8| | Reverse flow| Reserve
9| | Valve indicate| Valve control meter only
10| | Unit| Gal Unit
---|---|---|---
11| | Unit| Volume and flow rate
12| | Wireless communication| Reserve
13| | Unit| Temperature
14| | Currency| Prepaid mode only
15| | Tariff| Prepaid mode only

Operations on how to display
Users may touching off the button by magnet to read the meter information such as accumulated volume, current flow rate, etc.
To save the battery, the meter switches to sleep mode (display off) if the button is no operation for approx. 3 minutes. It can be woken up by trigger the button approximately 2 seconds. The following information is displayed in order by short touch the button: accumulated flow, instant flow, date, time, accumulated working time, Meter ID, address, meter type, software version No., checksum, etc.

Wake up Operation
If no any operations within 3 minutes, it will turn back to sleep mode. Touching off the button for 2 seconds to wake up the LCD from sleep mode.

Menu List (User Loop)
Touching off the button for more than 2 seconds and holding it on will bring up the four menus for users to select.

Bove-Technology-B97-VPW-Prepaid-Ultrasonic-Water-
Meter-05

Main Menu
Touching off the button for less than 2 seconds to display items under the Main Menu one by one in the following order to check the measurement data:

Menu E
Touching off the button for less than 2 seconds to display items under Menu E one by one in the following order to check the meter information:

Bove-Technology-B6-Lite-VW-Ultrasonic-Water-Meter-04

Bove-Technology-B6-Lite-VW-Ultrasonic-Water-Meter-05

Menu I
This Menu shows history date records of last 24 logs. Touching off the button for more than 2 seconds to select the log, then flow consumption will be displayed in turn.

Menu F
The following diagram shows Menu F (Calibration mode only). In F mode, Accumulated flow value is able to reset automatically, when flow is zero and starts to exceed the preset value then the current accumulated value is clear to zero. Also the value can be reset by long-trigger the button (over 2 seconds). The meter exit the calibration mode if no operation for 2 hours.

Note: preset value is pre-set to make sure zero calculation when there’s no water flow in the pipe, usually the value equals to 0.1% of Q3.

Monthly Data
The calculator stores the following values for 24 months at each end of month – Volume (meter reading) From the month set day display, press the button shortly to enter the previous month’s values. The month values can also be read out via the optical interface and other communication ports.

Error and Warning
The meter constantly performs self-diagnosis and can display various faults. Visual indication on the LCD display in the event of a warning. Permanent visual indication on the LCD:

Fault / Meaning / How to handle the error

  1. Low battery Communication circuit to be checked
  2. Empty Pipe Fulfill the pipe with water, no air bubble.
  3. Reverse Flow Reverse the water pipe.
  4. Over Range (High Instant flow rate) Lower the instant flow rate, or change a higher Range water meter.
  5. Water Temperature Error Lower the water temperature.
  6. EE Memory Error Change circuit board.
  7. Reserve –
  8. Reserve –

Corporate Profile
Bove provides comprehensive solutions on flow metering and control to over 30 countries in the globe. We design and manufacture range of flow metering solutions and IoT (internet of things) consumer products, which includes high accuracy water meter, thermal energy meter, testing bench, smart communication software’s for residential, commercial and industrial sectors. Since 2009 Bove has always been moving on the edge of technology to deliver state of the art products and solutions to customers all around the world.

A couple of our engineers are dedicated in metering and Communication industry for over 10 years, core team are previously working in Huawei, Baidu, IBM, and Citi Group, etc. With these talents Bove are able to provide prompt services and reliable products to our global customers.

Bove is committed to address the unique challenges that the residential and industry are facing, including increasing customer demand, water scarcity, and environment conservation. With hope, honor and our hard and quality work, we are looking to future to make Bove one of the best brands in metering industry in the world.

Our Mission
To exceed our customers expectation by providing prompt, quality and reliable technology.

Our Vision
Creating an Eco Society

Bove can accept no responsibility for possible errors in catalogues, brochures and other printed material. Bove reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without sub sequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Bove and the Bove logotype are trademarks of Bove Technology. All rights reserved.

Copyright© 2023 Bove Intelligent Technology Co., Ltd

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals