Product overview

The Smart Control Unit include of three parts which are water meter, smart valve, IoTunit. Easyfor customer bulk meter valve control purpose.

Technical Specification

Completer meter
Manufacturer Bove

Dimension
DN (mm)| Length| Height| Width| D| Bolt (flange) End Connection
50| 308| 410| 165| 125| 4*M16

65| 312| 430| 182| 145| 4*M16

80| 339| 452| 197| 160| 8*M16

100| 357| 475| 218| 180| 8*M16

125| 390| 503| 245| 210| 8*M16

150| 440| 540| 283| 240| 8*M20

200| 502| 582| 335| 295| 12*M20

250| 615| 720| 405| 355| 12*M24

300| 678| 790| 460| 410| 12*M24

350| 690| 853| 520| 470| 16*M24

400| 716| 964| 580| 525| 16*M27

Flow Measurement
DN (mm)| Flow Rate (m3/h) @R500
Q3| Q2| Q1

50| 25| 0.08| 0.05

65| 40| 0.128| 0.08

80| 63| 0.2016| 0.126

100| 100| 0.315| 0.2

125| 160| 0.512| 0.32

150| 250| 0.8| 0.5

200| 400| 1.28| 0.8

250| 630| 2.016| 1.26

300| 1000| 3.2| 2

350| 1000| 3.2| 2

400| 1600| 5.12| 3.2

Pressure Loss △P| ≤40KPa
MAP| 1.6MPa
Water temperature range (Optional)| 0.1-30°C(T30)/0.1-50°C(T50)
Q3/Q1 (optional)| R160/R200/R250
Accuracy| Class2
Maximum permissible error in upper flow rates range Q2 £ Q £ Q4| ±2%(at Temperature≤30°C)
±3%(at Temperature >30°C)
Maximum permissible error in lower flow rates range Q1 £ Q < Q2| ±5%
Scale interval (m3)| 0.001
Capacity of calculator| 99999,999
Type of liquid| Drink Water
Installation requirements| Min.5DN length of straight pipe before the meter, and Min.3DN length of straight pipe after the meter (DN is the diameter of meter)
Basic mounting  orientation and other specified orientations| Horizontal/Vertical
Display & Indication
Display unit (Optional)| m3/L/Gal
Display LCD| 8-digit
Volume| 0.001m³
Time to LCD off| Always on
Environmental Requirement
Environmental Class| E1,M1
Ambient temperature| 5~55°C(Indo or and non-condensing)
Storage temperature| -20~60°C
Protection Class (Optional)| IP68
Data history (Optional)| 24/120logs,daily/weekly/monthly
Interface & Communication
Output signal for normal operation (Optional)| Wire communication
RS485/M-Bus
Wire less communication
LoRa WAN/ NB-IoT/ Sigfox
Output display/signal for testing (Optional)| M-Bus,RS485,Infrared
Power Supply
Battery| Lithium Battery
Battery Life (Optional)| 6Years/10Years/16Years
24V DC (Optional)| External supply for special version
Mechanical Specification
Meter Body| Cast Iron

Valve part
Working temperature -30 to 210℃
Power DC12V/ External power (optional)
Pressure PN16
Connection Flange
Water protect IP68
Size DN50-400

Customer Support

Copyright© 2023 Bove Intelligent Technology Co., Ltd

Bove Intelligent Technology Co., Ltd

Add: Level 5, Building 5, No. 36,
Changsheng South Road, Jiaxing,
Zhejiang, China, 314000
Tel: +86 573 83525916
Fax: +86 573 83525912
Email: bove@bovetech.com
www.bovetech.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals