Table of Contents
- Check Contents
- Select a Location
- Remove Cover and Separate Base
- Connect the Camera
- Configure for Networking
- Change Video Format (Optional)
- Re-attach Cover
- Install Mounting Hardware (Optional)
- Remove Cover and Separate Base
- Install Mounting Bracket
- Route Cables and Connect the Camera
- Mount and Aim the Camera
- Complete Camera Setup
- Attach the Camera to a Supported VMS
- Camera Dimensions
- Register the Product
- Contact Information
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Quasar™ Premium
Mini-Dome Cameras
Quick Install Guide Items Included in Kit (images not to
scale)
Check Contents
Make sure all of the items above are included in the camera kit.
Select a Location
Warnings
- Placing a camera in an environment subject to extremely high temperature can result in an explosion or the leakage of flammable liquid or gas.
- Subjecting the camera to extremely low air pressure can result in an explosion or the leakage of flammable liquid or gas.
- The camera must be installed by qualified personnel and the installation should conform to all local codes.
Verify that the operating temperature falls within the following ranges, with 10-90% non-condensing humidity:
- Without heater: -30° C to 60° C (-22° F to 140° F)
- With heater: -55° C to 60° C (-67° F to 140° F)
- Cold start with heater: -40° C to 60° C (-40° F to 140° F)Make sure you have the required accessories and tools.
Make sure that the location provides a suitable method for routing cables to and from the camera.
Supplying Power to the Camera
The camera can be powered by:
-
A UL-listed L.P.S. (Limited Power Supply) unit, rated to a maximum temperature of 60° C:
o 12VDC, 1.21A minimum
o 24VAC, 50/60Hz, 1.2A minimum -
PoE (Power over Ethernet): 48 VDC, 0.27A minimum
Maximum Power Consumption with Heater and IR
CM-6405-11-I| 12.5 W
CM-6408-11-I| 11.5 W
For assistance with purchasing a power supply, contact Teledyne FLIR.
Remove Cover and Separate Base
Tip
When unpacking the camera, do not remove the plastic sheet protecting the
dome.
To remove the dome cover:
a. Using the Torx wrench, loosen the screw on the camera’s outer circular ring
that secures the dome cover to the camera base.
b. While firmly holding the base, rotate the ring counterclockwise to loosen
it.
c. Carefully pull the ring and cover away from the base.
To separate the camera base from the mounting bracket:
a. Using a screwdriver, loosen the two twist-lock screws securing the camera
and its base to the mounting bracket.
b. Gently pull the camera and its base away from the mounting bracket.
Change the number of LEDs (optional)
The camera has a total of eight IR LED illuminators. On the 3D lens assembly,
there is a switch that enables four (left when switch faces up) or all eight
(right; default). With the dome cover removed, you can change the switch
setting.
Connect the Camera
To install the camera, Teledyne FLIR recommends connecting the camera on a
bench or in a lab and configuring it for networking before mounting and aiming
it.
However, circumstances can dictate adjusting the sequence of the steps. For
example, you can mount the camera before configuring it for networking, or
connect the camera before mounting it.
Warning
The camera itself does not have a power on/off switch. Do not supply power
to the camera until you have completely finished connecting it.
Connector | Connection |
---|
RJ-45
Two LEDs| Attach a Cat 6 cable from the network switch to the RJ45 connector
for a 10/100/1000 Mbps Ethernet and IEEE 802.3af class 0 PoE connection.
Ethernet is required for streaming video and for configuring the camera.
The green link LED indicates a good network connection. The orange activity
LED flashes to indicate network activity.
Warning| The PoE unit and all interconnected equipment must be installed
indoors within the same building, including all PoE-powered network
connections, as described by Environment A of the IEEE 802.3af standard.
Connector| Connection
---|---
2| Four-pin power terminal block| 1| 24VAC –| 3| 12VDC –| If using a 24VAC or
12VDC power supply, connect it to the power terminal block connector according
to the pin assignment shown.
2| 24VAC +| 4| 12VDC +
| | The power cord to the 12VDC or 24VAC power supply unit must be connected
to a socket outlet with an earthing connector.
Warning
3| Default Button| To restore the camera to its factory defaults, use a proper
tool to press the default button for at least 20 seconds.
4| USB| Connects to Wi-Fi dongle (future release support)
5| microSD Card Slot| For video clip and snapshot recording and file storage,
insert a microSD / SDHC / SDXC card (maximum 1 TB) in the card slot. When the
camera is powered on, do not remove the microSD card.
6| Nine-pin terminal block| 1| Audio In L| 6| Alarm Out +| Attach wires from
external devices to the terminal block connector for alarm and audio in/out
according to the pin assignment shown.
2| Audio In R| 7| Alarm Out –
3| GND| 8| Alarm In +
4| Audio Out L| 9| Alarm In –
5| Audio Out R| |
Warnings
- Do not connect an external power supply to the nine-pin audio/alarm I/O terminal block connector.
- This product contains a battery that is soldered to the PCB. There is a risk of explosion if the battery is replaced by an incorrect type. Do not replace the battery. The battery should be disposed of in accordance with the battery manufacturer’s instructions.
Tip
To make it easier to mount and install the camera, while the camera is on the
bench or in the lab, you can connect Ethernet and other cable patch cords to
the camera’s connectors and route them through the grommets on the base and
through the mounting bracket. Then, you’ll be able to mount and install the
camera without separating the camera base from the mounting bracket a second
time.
Configure for Networking
To discover the camera on the network, Teledyne FLIR recommends using the FLIR
Discovery Network Assistant (DNA) tool, which does not require a license to
use, and is a free download from the product’s web page on the Teledyne FLIR
website. After downloading the DNA ZIP file, extract it.
Users assigned the Admin privilege level can configure the camera using the
DNA tool, the camera’s web page, or a supported VMS.
| DNA tool| Camera’s web page
---|---|---
Discover camera IP address| •|
Configure IP address, mask, and gateway| •| •
Configure DNS settings, MTU, and Ethernet speed| | •
Change user credentials| •| •
Change video format| •| •
Configure more than one camera at the same time| •|
For information about using the DNA tool to configure one or more cameras, see
the DNA User Guide. While the software is open, click the Help icon .
For information about using the camera’s web page to configure the camera, see
the camera’s installation and user guide. For information about using a
supported VMS to configure the camera, see the VMS documentation.
By default, DHCP is enabled on the camera and a DHCP server on the network
assigns the camera an IP address. If the camera cannot connect to a DHCP
server, the camera’s default IP address is 192.168.0.250. For example, if the
camera is managed by FLIR Horizon or Meridian VMS and the VMS is configured as
a DHCP server, the VMS automatically assigns the camera an IP address.
If the camera is managed by FLIR Latitude VMS or is on a network with static
IP addressing, you can manually specify the camera’s IP address using the DNA
tool or the camera’s web page.
To manually specify the camera’s IP address using the DNA tool:
a. Make sure the camera and the PC are on the same LAN segment.
b. Run the DNA tool (DNA.exe) by double-clicking .
The Discover List appears, showing compatible devices on the LAN segment and
their current IP addresses.
c. In the DNA Discover List, verify that the camera’s status is Online.
If this is the first time you are configuring the camera or if it is the first
time after resetting the camera to its factory defaults, DNA authenticates the
camera with user name admin using its default password (admin).
If the admin user’s password is not the default password, you need to
authenticate the camera.
- In the DNA Discover List, select the camera and then click Login.
- In the DNA – Login window, type a user name for a user assigned Admin privileges and the password. If you do not know this information, contact the person who configured the camera’s users and passwords.
- Click Login, wait for Ok status to appear, and then click Close.
d. Verify that the camera’s Login status is Authenticated.
e. Change the camera’s IP address.
- Right-click the camera and select IP Setup.
- In the DNA – IP Setup window, clear Use DHCP and specify the camera’s IP address. You can also specify the Mask (default: 255.255.255.0) and Gateway.
Then, click Update, wait for Ok status to appear, and then click Close.
Change Video Format (Optional)
By default, NTSC is the camera’s video format.
You can change the camera’s video format to PAL using the DNA tool.
a. In the DNA Discover List, right-click the camera and select Change Video
Format.
b. In the Change Video Format window, select PAL. If Shutter WDR 30 FPS NTSC
is the camera’s current video format, this changes the camera’s video format
to Shutter WDR 25 FPS PAL. Likewise, if Linear 60 FPS NTSC is the camera’s
current video format, this changes the camera’s video format to Linear 50 FPS
PAL.
c. Click Update, wait for Ok status to appear, and then click Close.
Re-attach Cover
To prevent damaging the camera’s internal components while moving it from the
bench or lab to its mounting location, re-attach the dome cover to the base
and then remove it again at the mounting location.
Before doing so, you can re-attach the camera base to the mounting bracket.
Use a screwdriver to tighten the two twist-lock screws securing the camera and
its base to the mounting bracket. If you do not re-attach the camera base to
the mounting bracket, remember to bring the screwdriver to the mounting
location.
To re-attach the dome cover:
a. Using the two guide pins on the dome cover and the triangles on the cover
and on the base, carefully align and position the dome cover and outer ring
onto the base.
b. Make sure the outer ring sits flat on the base. Then, securely tighten the
outer ring.
c. Lock the ring. Using the Torx wrench, tighten the screw on the outer ring
that secures the outer ring to the base.
Install Mounting Hardware (Optional)
Using the hardware included in the camera kit, you can mount the camera onto a
standard electrical box or onto a suitable surface. For information about
other mounting options, including the list of Teledyne FLIR mounting
accessories that support the camera, see the camera’s installation and user
guide.
If you are using mounting hardware not included in the camera kit, install it
according to the installation instructions for the hardware. If necessary,
adapt the instructions in this guide to those instructions.
Remove Cover and Separate Base
Repeat the steps described in 3 Remove Cover and Separate Base.
Install Mounting Bracket
To install the mounting bracket on a standard electrical box:
Attach the bracket to the box using:
- The holes in the mounting bracket, according to the types of boxes engraved on the bracket
- The corresponding holes in the box
- Suitable bolts, washers, and nuts (not included in the camera kit)
To install the mounting bracket directly on a surface:
a. Choose four widely spaced mounting holes on the bracket for optimum flat
surface mounting.
b. Using the bracket as a template to mark the surface, drill four anchor
holes.
c. (Optional) If necessary, drill a hole wide enough for routing cables.
d. Hammer the four plastic screw anchors into the drilled holes.
e. Insert the anchors and then attach the bracket to the surface using the
four M4 25mm self-tapping screws included in the camera kit.
When tightening the screws, the holes in the mounting plate allow for making
small adjustments to the bracket’s position.
Route Cables and Connect the Camera
Cables can enter the camera from the side or from the rear. To route cables
through the side of the camera, use the Torx wrench to loosen the screw
securing the side conduit hole cover and remove the hole cover. Then, route
cables through the hole. To route cables through the rear of the camera, route
cables through the hole in the mounting bracket.
To route cables into the camera base:
a. For each cable, use the Torx wrench to punch a hole in the center of the
rubber glands in the the camera’s base, from the underside.
b. Route the cable through the hole in the grommet.
To route an Ethernet cable with an RJ45 plug attached, attach the supplied
RJ45 insertion tool to the RJ45 plug. Then, route the tool, plug, and cable
through the grommet. Remove the tool.
c. Push the cables back through the seal so that the seal extends out of the
base.
According to the information in 4 Connect the Camera, connect the camera.
Note
Connect the camera to a 24VAC or PoE power source as the primary power source,
and then connect 12VDC as the secondary power source. If the primary power
source fails, the camera seamlessly switches to 12VDC until the primary power
source is restored.
Mount and Aim the Camera
a. Make sure that the camera is facing the required field of view. Then,
carefully re-attach the camera base to the mounting bracket. Use a screwdriver
to tighten the two twist- lock screws securing the camera and its base to the
mounting bracket.
b. Aim the camera, which has three axes for adjusting the field of view:
- Pan adjustment – Rotate the lens base until satisfied with the field of view.
- Tilt adjustment – Loosen the screw locking the camera lens in its tilt angle. Tilt the lens until satisfied with the field of view. Then, tighten the screw.
- Lens rotation – Rotate the 3D assembly in the lens until satisfied with the field of view.
Caution
Do not rotate or tilt beyond the mechanical limits for each axis:
- Pan adjustment range: 356°
- Tilt adjustment range: ±80°
- Lens rotation range: ±98° – Rotating the 3D assembly in the lens beyond its mechanical limit can twist, disconnect, or break the camera’s internal cables.
At the camera’s widest view (zoom = 1x) and at certain tilt / rotation angles, a small part of the camera can appear in the far upper-left corner of the field of view.
Tilt angle | Lens rotation angle range |
---|---|
20° | 30°~45° |
10° | 10°~45° |
c. Repeat the steps described in 7 Re-attach Cover.
Complete Camera Setup
Depending on installation and use, completing camera setup can consist of
adjusting the camera’s zoom and focus; and formatting the microSD card.
To complete camera setup, you need to access the camera’s web page, which
supports the latest version of Google Chrome® and other popular web browsers.
To access the camera’s web page:
a. Do one of the following:
- In the Teledyne FLIR Discovery Network Assistant (DNA) tool, double-click the camera in the Discover List.
- Type the camera’s IP address in a browser’s address bar (when the PC and the camera are on the same network). If you do not know the camera’s IP address, you can use the DNA tool to discover it.
b. On the login screen, enter a user name and the password. Passwords are case-sensitive. If you do not know a user name or the password, contact the person who configured the camera’s users and passwords.
When logging in to the camera for the first time or for the first time after resetting the camera to its factory defaults:
-
Log in with user name admin and the default password, admin.
-
Specify a new password for user name admin:
o must be 8-64 characters
o can include the following special characters: @#~!$&<>+_-.,*?
o cannot include four-digit sequences (for example, 1234)
o cannot include four repeating characters (for example, aaaa) -
Log back in using the new password.
The camera’s View Settings home page opens.
To adjust the zoom and focus:
Use the controls on the View Settings home page. They are available when a
View Settings menu page is not open.
To format the microSD card:
a. Click System Settings. Then, open the SD Card page.
b. Under SD Format, select vfat (default) or ext4 (recommended).
c. Click Format.
Additional Configuration Steps
Setting up the camera can also consist of configuring or modifying the default
video stream settings; exposure, white balance, WDR, and other picture
settings; security, advanced networking, event notification, and other system
settings.
Many of these configuration steps can be performed before or after mounting the camera. However, some of them can or should only be performed after mounting the camera. For more information about configuring the camera, see the camera’s installation and user guide.
Attach the Camera to a Supported VMS
After mounting the camera and discovering or defining its IP address, use VMS Discovery/Attach procedures to attach the camera to a supported VMS.
Camera Dimensions
Register the Product
Register the product at https://customer.flir.com.
For warranty information, see
https://www.flir.com/supportcenter/warranty/security/flir-security-product-
warranties/.
Contact Information
Americas
6769 Hollister Avenue
Goleta, CA 93117
USA
Support: https://support.flir.com/
27700 SW Parkway Ave.
Wilsonville, OR 97070
USA
References
- Loading...
- Thermal & Visible Security Cameras | Teledyne FLIR
- FLIR Security Product Warranties | Teledyne FLIR
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>