The HEATSTRIP Indoor is a slim, efficient heating solution suitable for both commercial and residential applications. Its enhanced design ensures rapid heat dispersion to provide an ideal indoor comfort heat environment.

Features

  • High surface area to radiate heat efficiently and effectively
  • Design flexibility to meet BCA requirements with multiple mounting options
  • Suitable for multiple applications including classrooms, sports facilities, shops, factories, churches, restaurants, warehouses, showrooms, childcare facilities, offices, industrial heating, and more
  • Easy installation with multiple mounting options including standard ceiling brackets, angled wall mounting, flush ceilingmounting, T-Bar ceiling mounting, and chain/wire suspension mounting

Specifications

Model| Power (Watts)| Current (Amps)| Dimensions (mm)| Weight (Kg)| Lead Length (mm)| Plug
---|---|---|---|---|---|---
THS800A| 800| 3.3| 624 x 235 x 48| 4| 1000| Yes
THS1200A| 1200| 5.0| 924 x 235 x 48| 6| 1000| Yes
THS1800A| 1800| 7.5| 1384 x 235 x 48| 8| 1000| Yes
THS2400A| 2400| 10| 1834 x 235 x 48| 11| 1000| Yes

Selection Guide

The ideal mounting height for the HEATSTRIP Indoor is between 2.3m to 2.7m, with a maximum of 3.0m in an insulated indoor environment. The following table provides a guide to therecommended indoor insulated and indoor protected areas for each model:

Model Indoor Insulated (m2) Indoor Protected (m2)
THS 800A 8 5
THS 1200A 12 8
THS 1800A 18 12
THS 2400A 24 16

Note that these values are a guide only and may vary depending on the individual site and conditions.

Installation Requirements

For mounting heights above 3.0m, we recommend using optional accessories to reduce the height of the unit. See the accessory section of the manual for more information. Electrical connections/GPO’s should not be located at the back of the heater to minimize heat build-up behind the units.

Product Usage Instructions

The HEATSTRIP Indoor can be designed to provide comfort heating for a variety of indoor spaces. The ideal mounting height and location will depend on the specific application and conditions. Refer to the selection guide for recommended indoor insulated and indoor protected areas for each model.
When installing, ensure that electrical connections/GPO’s are located outside the physical footprint of the unit to prevent heat build-up behind the unit. Choose from multiple mounting options including standard ceiling brackets, angled wall mounting, flush ceiling mounting, T-Bar ceiling mounting, and chain/wire suspension mounting for easy installation.
The HEATSTRIP Indoor is an efficient and effective heating solution for a range of indoor applications, providing comfortable and targeted heat to single rooms or large areas.

Features & Benefits

  • Stylish, Modern, Sleek, Slimline design
    The new modern, slimline design of the Heatstrip Indoor makes it the sleekest profile on the market. It will elegantly and seamlessly blend into any indoor environment or décor.

  • Effective, efficient heating solution for all tough-to-heat, open indoor applications
    The innovative design of the HEATSTRIP® enables comfortable and even heat dispersion from the surface with minimal operating costs.
    Up to 90% of the heating energy is directed to the area to be warmed, while 10% is emitted as convective heat. This high-efficiency ratio means a greater heating value.
    These medium-intensity heaters have an improved water protection rating of IP45 and are specifically designed for indoor heating.

  • Enhanced Heatstrip performance
    The HEATSTRIP Indoor design incorporates a unique profile with a high surface area to radiate heat efficiently and effectively. The enhanced design of the heating panel ensures rapid heat dispersion to provide an ideal indoor comfortable heat environment.

  • Design Flexibility to Meet BCA Requirements
    4 different models and multiple mounting options within the range allow for the design of innovative heating systems to meet stringent BCA requirements.

  • Suitable for Multiple Applications — commercial & residential
    HEATSTRIP Indoor can be designed to provide comfortable heating for a single room or a large stadium, and either a large group or a single person.
    Heatstrip Indoor is ideal for a range of applications such as classrooms, lecture halls, sports facilities, shops, factories, churches, restaurants, warehouses, showrooms, childcare facilities, offices, industrial heating, dance & yoga studios and bedrooms, living rooms, bathrooms etc.

  • Multiple Mounting Options allow for easy installation
    Standard ceiling brackets are supplied, plus optional brackets are available for angled wall mounting, flush ceiling mounting; T-Bar ceiling mounting, and chain/wire suspension mounting.

  • Minimal maintenance
    The HEATSTRIP® Indoor incorporates no internal moving parts, ensuring quiet and virtually maintenance-free operation.

  • Australian made
    Designed, engineered, and manufactured in Australia, the HEATSTRIP® Indoor is fully backed by a 24-month residential warranty and a 12-month commercial warranty.HEATSTRIP-THS1200A-1 \(3\)

Specifications

MODEL| POWER (WATTS)| CURRENT (AMPS)| DIMENSIONS

(mm)

| WEIGHT (Kg)| LEAD LENGTH

(mm)

| PLUG
---|---|---|---|---|---|---
THS800A| 800| 3.3| 624 x 235 x 48| 4| 1000| YES
THS1200A| 1200| 5.0| 924x 235 x 48| 6| 1000| YES
THS1800A| 1800| 7.5| 1384 x 235 x 48| 8| 1000| YES
THS2400A| 2400| 10| 1834 x 235 x 48| 11| 1000| YES
MODEL|  |
---|---|---
HEATER TYPE| High intensity electric radiant overhead heater with high surface area profiled alloy
OUTPUT| Refer to model code chart above
POWER| 230-240 Volts Nominal at 50—60 Hertz, Single Phase
CONNECTION| 3 Core Cable 25mm| 2
APPROVALS| AUSTRALIA/NZ|
MOUNTING HEIGHT| MINIMUM RECOMMENDED MAXIMUM| 2.1 m

2.3 m to 2.7 m

3.0 m (For higher ceiling heights, units can be lowered using optional bracket kits or refer to the Heatstrip Max range)

MOUNTING OPTIONS| Suitable for ceiling, wall and recess mounting. Also available for suspension chain mount bracket.
PROTECTION RATING| IP45 Protection from water ingress from all directions
COUNTRY OF MANUFACTURE| Australia|

HEATSTRIP-THS1200A-1 \(4\)

Selection guide

General recommendations for HEATSTRIP® Indoor:

  • Ideal mounting height: 2.3m to 2.7m. Maximum is 3.0m in an insulated indoor environment.
  • Ideal mounting location: ceiling mounted, directly above area to be heated (eg. above a table, seating area etc.)

The below table outlines the coverage of each HEATSTRIP® Indoor model (in m2), based on 2 different scenarios. For example, for an indoor area that is protected, Model THS 1800A will cover 12m2 and Model THS 2400A will cover 16m2.

MODEL

|

INDOOR INSULATED (m 2)

|

INDOOR PROTECTED (m 2)

---|---|---
THS 800A| 8| 5
THS 1200A| 12| 8
THS 1800A| 18| 12
THS 2400A| 24| 16

The above is a guide only and may vary depending on the individual site and conditions.HEATSTRIP-THS1200A-1 \(5\)

Installation Requirements
The ideal mounting position for the HEATSTRIP® Indoor is on the ceiling, directly above the area to be heated. If this is not possible, HEATSTRIP®. Indoor can be mounted on a wall and angled downwards. In this situation, ensure the mounting height is in the range of 2.1m to 3.0m.

  • For mounting heights more than 3.0m, we recommend the use of the optional accessories to reduce the height of the heater to 2.3m—3.0m. This will increase the effectiveness of your HEATSTRIP®. Refer to the Mounting Accessory section for more information.
  • Electrical connections/GPO’s should not be located at the back of the heater. They should be located outside the physical footprint of the units to minimize heat build-up behind the units.
  • If the heater is to be mounted on an incline (eg. vaulted ceiling), ensure the electrical connection is located at the lowest point of the heater.HEATSTRIP-THS1200A-1 \(6\) HEATSTRIP-THS1200A-1 \(7\)

Installation location

The below diagrams confirm the minimum recommended clearances.HEATSTRIP-
THS1200A-1 \(8\) HEATSTRIP-THS1200A-1 \(9\)

Mounting options

The installation of HEATSTRIP® Indoor is simple and easy with the standard mounting brackets supplied. For other, more challenging locations there are a range of mounting options available – refer to below diagrams.
The HEATSTRIP® Indoor can be mounted directly to the ceiling; angled downwards on a wall; fitted flush with the ceiling; suspended on chains or mounted end- to-end. Refer to the following pages for more detailed information on each mounting option.HEATSTRIP-THS1200A-1 \(10\) HEATSTRIP-THS1200A-1
\(11\)

Standard mounting brackets

The HEATSTRIP® Indoor comes with a pair of standard mounting brackets. These brackets allow direct ceiling mount.
The brackets need to be mounted onto a secure frame or ceiling with a minimum distance between the two brackets. The minimum distance (“B”) for each model is listed in the table below.
When completing the installation, ensure all screws are tight and unit is secure.

MODEL| “B”

MINIMUM DISTANCE (mm)

---|---
THS800A| 350
THS1200A| 500
THS1800A| 700
THS2400A| 1000

HEATSTRIP-THS1200A-1 \(12\)

Standard Mounting Bracket

PART No| PACKAGED DIMENSIONS (mm)| WEIGHT

(kg)

| MATERIALS
---|---|---|---
ZBRAK-92| 200 x 50 x 50| 0.5| MILD STEEL POWDER- COATED WHITE

Angle mounting brackets

PART No.| PACKAGED DIMENSIONS (mm)| WEIGHT

(kg)

| MATERIALS
---|---|---|---
THSAC-020| 200 x 200 x 50| 0.5| MILD STEEL POWDER- COATED WHITE

The HEATSTRIP® Indoor has optional angle mounting brackets. These brackets can be mounted to the ceiling or the wall to bring the effective heat closer to where it is needed.
The angle of the bracket is preset to 45o.
When installing, ensure that the minimum distances are maintained. Screws are not provided.HEATSTRIP-THS1200A-1 \(14\)

Angle Mounting Bracket

Flush Mount Enclosure

  • The Flush Mount Enclosure is an ideal way to neatly install the Heatstrip® Indoor into a ceiling. They are available for all Heatstrip®
  • Indoor models, and are supplied as a one-piece unit for mounting of heaters. Flush mounting can use with plaster or wood-lined ceiling materials.
  • An ideal mounting height is 2.1-2.7m.
  • Maximum mounting heights should be strictly followed, otherwise, the performance of the units may be reduced.
  • The facia is made from white powder-coated mild steel.HEATSTRIP-THS1200A-1 \(15\)
    SUITABLE FOR MODELS| PART No| HOLE CUTOUT DIMENSIONS (mm)| OVERALL DIMENSIONS (mm)| WEIGHT

(kg)

---|---|---|---|---
THS800A| THSAC-025| 720 x 300| 740 x 345 x 100| 4
THS1200A| THSAC-026| 1020 x 300| 1040 x 345 x 100| 4
THS1800A| THSAC-027| 1480x 300| 1500 x 345 x 100| 5
THS2400A| THSAC-028| 1930 x 300| 1950 x 345 x 100| 5

End-to-end mounting bracket

The end-to-end bracket allows multiple units to be joined in a straight line for maximum heat performance and aesthetic appeal. This is ideal for applications such as long rows of tables and assembly lines, where constant heat coverage is required.
The bracket allows for a 50mm gap between units and an opening for the power connection. As per the diagram below, units should be mounted with the power leads together.
The end-to-end bracket can be used with the standard ceiling/wall mount bracketHEATSTRIP-THS1200A-1 \(17\)

PART No PACKAGAED DIMENSIONS (mm) WEIGHT (kg) MATERIALS
THSAC-029 260x200x30 1 MILD STEEL POWDER- COATED WHITE

Safety

  • HEATSTRIP® Indoor has an IP rating of 45. This means it is safe for water ingress from all directions. The HEATSTRIP® can be safely hosed down.
  • HEATSTRIP® has undergone extensive testing both in laboratory conditions; in Thermofilm’s manufacturing facility in Melbourne and field trials in Australia and overseas. It has been this testing that gives the purchaser the confidence of a high quality product.
  • Independent laboratory testing has confirmed Thermofilm’s full compliance with Australian and other International Standards. This includes CE, AS/ANZ, UL/CSE
  • All heater models come with a plug. The fixed wiring must be installed by a licensed electrician in accordance with the relevant wiring regulations.
  • HEATSTRIP® is Class 1 equipment and must be earthed.
  • In operation, this heater is VERY HOT— do not touch any part of the heater while it is turned on. Do not touch any part until 30 minutes after it is turned off.
  • This appliance is not intended for use by persons (including children) with reduced physical, sensory or intellectual capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure they do not play with the appliance.
  • Do not allow any cables, furnishings, flammable materials or other items come in contact with any surface of the heater.
  • If installed in wet areas, the heater switches or controls must be located so that they cannot be touched by persons in the bath or shower.
  • The heater needs to be installed as per the installation instructions paying special attention to the minimum clearances. The heater needs to be mounted on a rigid bracket or fixing.
  • The heater must not be mounted immediately below or in front of a socket outlet.
  • In case of a heater fault or damaged supply lead, the appliance should be returned to the point of purchase for return to Thermofilm for repair.

Maintenance

  • The HEATSTRIP® is made from durable materials, however regular care and maintenance of your heater will help prolong the life of the heater.
  • It is recommended that you hose down the heater and with a soft cloth gently wipe the surfaces of the heater with a mild detergent to remove the built up contaminants from the environment. Then rinse all detergent off the heater.
  • All chemicals in the atmosphere including cigarette smoke, pollution etc. will tarnish the surface of the heater. In this case, additional cleaning and maintenance may be required. The cleaning process at least every three months will reduce the amount of build up and keep it looking as best it can. If the heater is in a corrosive environment eg. salt spray, we recommend that you clean your heater with a light spray of fresh water every week. After cleaning, turn the heater on for 20 minutes to dry any water residue and prevent water staining.
  • Before cleaning or inspection activity, the heater must be switched off and cooled down completely.
  • Do not use any abrasive materials or products to clean the heater, this includes solvents, citrus-based cleaners or other harsh cleaning products.
  • When handling the heater, ensure that your hands are clean or that you use clean gloves as grease or dirt can mark the surface of the heater.
  • Do not use high-pressure water to clean heaters, light water spray only.

HEATSTRIP Plug-In Remote Controller

The TT-MTR-PLUG has been designed to provide easy remote control timer functionality to wall socket-powered HEATSTRIP® heaters. The unit can however be used to remotely operate with timer functionality any device powered by a standard 10A Australian wall socket outlet.
The TT-MTR-PLUG controller consists of a remote control and a plug-in wall socket timer unit to provide easy wireless timer operation.

Design Features

  • The TT-MTR-PLUG provides an easy means of remotely turning on appliances that are normally permanently connected to a standard wall socket.
    An easily selected 1-hour, 2-hour, and 4-hour timer function accessible on both the wall unit and remote

  • Programmable remote control unit capable of controlling multiple units.

Remote battery CR2025, 3V, Lithium
Remote range 10m
Wall socket supply 220V — 240V, 50Hz
Max load 10A (2400W)
Standby consumption <1W
Remote frequency 38kHz IR
Approvals Australian Standards AS/NZ

3105, 3112, 3100

Packaged dimensions| 140 x 65 x 67
Unit weight|

HEATSTRIP® Wall Controller with Remote

TT-MTM2 Wall Controller This controller is a custom-designed and manufactured controller for HEATSTRIP heaters. It has been designed for ease of use and to provide low running costs of your heater. It provides both temperature control (allowing the user to turn the heat output up or down depending on the ambient temperature and conditions) and a timer for automatic heater shut-off operation. The timer function has 4 settings: 1 hour, 2 hours, 4 hours or constantly on. This feature is ide-al for applications such as BBQ areas, alfresco areas, restaurant dining, assembly line production etc. When continuous heat is not required. The timer also reduces the likelihood of heat-ers being inadvertently left turned on.
Depending on the ambient temperature there may be a requirement to control the heat output of the heater. The controller has 3 settings, they are High, Medium and
Low.
The controller allows a combination of the multiple timers (1/2/4 hour) and heat outputs (High/Medium/Low)HEATSTRIP-THS1200A-1
\(20\)

MODEL| MAXIMUM VOLTAGE (Volts)| MAXIMUM CURRENT (Amps)| PACKAGED DIMENSIONS (mm)| UNIT WEIGHT (kg)
---|---|---|---|---
TT-MTM| 240| 16| 150 x 95 x 55| 0.3

Controlling multiple heaters
It is possible to use one wall controller to control multiple heaters. The wall controller is rated at 16 Amps and 240 volts.

Remote Pairing
All units operate using the same remote control frequency, therefore, multiple wall controllers can be operated using a single remote control. The remote will function at distances of over 8m when used in a straight line, This distance reduces when used at an angle.

Operation

Press the “On/Off” button to turn the power on and off. Once turned on, the controller will default to the High power setting and will be permanently on (no timer function). Press the “POWER” button to select the desired power setting by cycling through HIGH—MEDIUM -LOW. When the power setting is high the controller will provide continuous power. When the power setting is at “MEDIUM” or “LOW” the output alternates between being on and off so that it delivers a lower output to the heater. Press the “TIMER” button to set the timer to 1,2,4 hour or permanently on. When permanently on, one of the TIMER LEDs will be illuminated. Once the timer is selected, the timer will be started immediately. When the timer has ended, the power will turn off and all LEDs will also turn off.

Thermal Cut-Out Protection

This controller is protected by a thermal cut-out switch. This switch is activated when the temperature of the controller is too high. The controller will cut all power until it has sufficiently cooled. Once it cools the unit will continue working as usual.

Warm Up Mode

The controller is programmed to operate continuously (High setting) for the first 15 minutes of opera-tion regarding less of the selected power setting, this is to allow time for the heater to warm up. After this time it will operate as selected.

Safety

The TT-MTM controller is to be mounted indoors it needs to be away from wet conditions. Ensure the connections are properly connected. The controller needs to be installed according to your local wiring guidelines and regulations . Do not allow any cables, furnishings, flammable materials or other items to obstruct the vents of the controller. Never block the air vents of the controller.
Never block the air vents of the controller. Do not put anything in the vents of the controller.
The appliance is not intended for use by persons (Including children) with reduced physical, sensory or intellectual capabilities, or lack of experience and knowledge unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety. Children should be supervised to ensure they do not play with the appliance.

Maintenance

The TT-MTM Controller is made from durable materials, however regular care and maintenance of your controller will help prolong the life of the product. It is recommended that you dust the controller to keep the surface clean. Cleaning at least every three months will reduce the amount of dust build-up and keep it looking at its best. Do not use any abrasive materials or products to clean the controller, this includes solvents, citrus-based cleaners or other harsh cleaning products. Do not use water or a damp cloth to clean the controller. The remote uses a CR2025 3V lithium battery. If the red light on the remote stops working then change the battery.

Controller Wiring Example

HEATSTRIP-THS1200A-1
\(21\)

The TT-MTM2 Controller required sufficient air circulation in order to provide continuous operation on the high power load setting. The vents must always remain clear; never block or cover the vents. An ideal controller installation will provide significant space around the back of the controller. Installing into restricted spaces, such as brick walls, may result in overheating if adequate ventilation is not provided.

Heater wiring schematic diagrams

It is recommended to install an ON/OFF isolation switch before the controller and ensure the unit is turned OFF after use.
Multiple heaters can be operated using a single controller, however the maximum current rating of 16A must not be exceeded. For direct wiring to the controller, the maximum is generally on heater unit unless the combined maximum current is less than 16A. For example, 2x THH1800A can be connected directly to the controller.
Below are example circuits indicating potential installation configurations.
Always check with your electrician and ensure all wiring is in accordance with local regulations.HEATSTRIP-THS1200A-1 \(22\)

Warranty Terms & Conditions

The below Warranty Terms and Conditions apply for New Zealand and Australia only. For international warranty please refer to international warranty terms and conditions.
Thermofilm warrants to the original owner that HEATSTRIP® Classic products will be free from defects in materials and workmanship for a period of 24 months for residential use from the date of purchase in accordance with the following warranty terms and conditions. For commercial use warranty is 12 months.

Provision of this warranty is subject to:

  • The HEATSTRIP® product must be installed in accordance with the Installation Instructions and relevant electrical standards and codes.
  • The HEATSTRIP® product must be maintained and cleaned according to instructions detailed in the Installation Manual.
  • There is no warranty expressed or implied with regard to capacity requirements. The selection of the unit or units depends entirely upon the system design and capacities as determined by the purchaser.
  • The customer has not repaired, opened, or altered the product in any unauthorized manner.
  • This warranty excludes damage to the product or components arising from circumstances outside the control of Thermofilm, including, but not limited to, where the product is not used for the intended purpose; where the product has been rectified in any way; incorrect installation; incorrect power supply; damage caused during delivery; misapplication, misuse, abuse, vandalism, lack of maintenance or accident.
  • Thermofilm’s obligations under this warranty are limited to repair or replacement at Thermofilm’s factory of any components of the product which Thermofilm identifies to its satisfaction to be defective.
  • Transportation charges involved in the return of the product to the Thermofilm factory (or any other location authorized in writing by Thermofilm) is the sole responsibility of the customer.
  • All products are inspected and tested before despatch and are at the risk of the purchaser after the shipment from the Thermofilm factory, if not delivered by Thermofilm to the destination.
  • Discoloration of the surface may occur after a period of time, this does not constitute a warrantable event.
  • Twisting and bending of the heaters may occur, this does not constitute a warrantable event.
  • No products or components will be supplied in advance of an examination of the faulty product or components by Thermofilm or an authorized representative of Thermofilm.
  • Thermofilm does not participate in any site-related costs or labor expenses incidental to the replacement of parts, repairing, removing, installing, servicing, transportation or handling of parts to complete products, and assumes no liability for parts repaired or replaced without written authorization. Thermofilm shall not be liable for any default or delay in the performance of its warranty obligations caused by any circumstances beyond its control, including, but not limited to, judicial or government restrictions, strikes, fires, floods, abnormal weather conditions, or delayed supply of components.

Should products be determined as damaged on arrival, immediately notify the transport company of the condition and have them noted on the freight documents. If damage is discovered after unpacking, demand immediate inspection by the transportation company and insist that a record of the damage is made on the freight documentation.

The customer warrants using the product in accordance with:

  • Any instructions provided to it by Thermofilm from time to time.
  • All government and local regulations, including but not limited to all relevant electrical, and environmental laws and regulations governing the installation, storage, use, handling, and maintenance of the goods.
  • All necessary and appropriate precautions and safety measures relating to the installation, storage, use, handling, and maintenance of goods.

Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and for compensation for any other reasonably foreseeable loss or damage.
You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure.
All warranty requests for repairs or replacements must be accompanied by a complete “Warranty Claim Form” available from Thermofilm, together with proof of purchase (and where possible, photos of the installation) and the heater returned to the place of purchase.
In the event of a warranty claim, the goods need to be returned to the distributor/retailer for repair/replacement. Contact

Thermofilm Australia Pty Ltd 8 Lakeview Drive, Scoresby, Victoria 3179, Australia Telephone: (03) 9562 3455,
Email : [email protected]

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Heatstrip User Manuals

Related Manuals