JOTUL GF 300 DV Direct Vent Gas Stove Steel Burner User Manual

June 10, 2024
Jotul

Jøtul GF 300 DV
Allagash v.2
Direct Vent Gas Stove Steel Burner Installation and Operation Instructions
For stoves Serial Number 42005149 and above Conforms to ANSI Z21.88-2019 • CSA 2.33-2019, and CAN/CGA 2.17-M91.

INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.

 GF 300 DV Direct Vent Gas Stove Steel Burner

WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
– Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
– WHAT TO DO IF YOU SMELL GAS

  • Do not try to light any appliance.
  • Do not touch any electrical switch; do not use any phone in your building.
  • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
  • If you cannot reach your gas supplier, call the fire department.
    – Installation and service must be performed by a qualified installer, service agency or the gas supplier.
    – In the Commonwealth of Massachusetts, a carbon monoxide (CO) detector shall be installed in the same room as the appliance.

This appliance may be installed in an aftermarket, permanently located, manufactured home or mobile home, where not prohibited by local codes. This appliance is only for use with the types of gas indicated on the rating plate. A conversion kit is supplied with the appliance.
**DANGER**
HOT GLASS WILL
CAUSE BURNS
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
A barrier designed to reduce the burn hazard from the glass viewing area is provided with this appliance and shall be installed for the protection of children and other at-risk individuals.
THIS OWNER’S MANUAL PROVIDES INFORMATION TO ENSURE SAFE INSTALLATION AND EFFICIENT, DEPENDABLE OPERATION OF YOUR FIREPLACE INSERT. PLEASE READ THESE INSTRUCTIONS IN THEIR ENTIRETY AND MAKE THEM AVAILABLE TO ANYONE USING OR SERVICING THIS GAS INSERT.
DO NOT ATTEMPT TO ALTER OR MODIFY THE CONSTRUCTION OF THIS APPLIANCE OR ITS COMPONENTS. ANY MODIFICATION OR ALTERATION WILL VOID THE WARRANTY, CERTIFICATION AND LISTING OF THIS APPLIANCE. THIS HEATER MUST BE INSTALLED AND MAINTAINED BY A QUALIFIED SERVICE AGENCY.

Suggested Tools for Installation and Service

  • External regulator (for Propane only)
  • Piping which complies with local code
  • Manual shut-off valve – T-Handle required in Massachusetts
  •  Sediment trap – if required by code
  • Tee joint
  • Pipe wrench
  • Pipe sealant
  • 10 mm open end wrench
  • 1/2”, 7/16” open end wrench
  • Phillips head screwdriver
  • Flat head screwdriver
  • 1/4” nut driver
  • Gloves
  • Safety glasses
  • Torx T-20 screwdriver
  • Tin snips

PLEASE NOTE: Initial Break-in
It is normal for smoke and odor to occur during the initial stages of operation, depending upon temperatures generated over time. This “curing” condition can be alleviated by promoting fresh air circulation within the immediate vicinity of the appliance.
Operation Sound
Please be aware that cast iron and steel components expand and contract with temperature fluctuations that are often accompanied by “creaking” or “pinging” sounds.
This is the result of natural thermal activity. The optional blower fan will also generate a slight hum at the low setting and progressively increase with the velocity of forced air. Installation Requirements for the Commonwealth of Massachusetts
THIS PRODUCT MUST BE INSTALLED BY A LICENSED MASTER OR JOURNEYMAN PLUMBER OR GAS-FITTER WHEN
INSTALLED IN THE COMMONWEALTH OF MASSACHUSETTS.

  1. If there is not one already present, on each floor level where there are bedroom(s), a carbon monoxide detector and alarm shall be placed in the living area outside the bedroom(s). The carbon monoxide detector shall comply with NFPA 720 (2005 Edition).

  2. A carbon monoxide detector shall:
    a) Be located in the room that houses the appliance or equipment;
    b) Be either hard-wired or battery powered or both; and
    c) Shall comply with NFPA 720 (2002 Edition).

  3. A Product-approved vent terminal must be used, and if applicable, a Productapproved air intake must be used.

Installation shall be in strict compliance with the manufacturer’s instructions. A copy of the installation instructions must remain with the appliance or equipment at  the completion of the installation.

www.nficertified.org

We recommend that our gas products be installed and serviced by professionals who are certified in the U.S. by the National Fireplace Institute® (NFI) as NFI Gas Specialists.JOTUL GF 300 DV Direct Vent Gas Stove Steel Burner -
iconf

Jøtul GF 300 DV Allagash Direct Vent Gas Heater
Manufactured and Distributed by: Jøtul North America 55 Hutcherson Dr. Gorham, Maine 04038
Certified Test Standards
This appliance complies with National Safety standards and is tested and listed by Intertek Testing Services of Middleton, Wisconsin to ANSI Z21.88-2019 / CSA 2.33-2019,
and CAN/CGA 2.17-M91.
Your stove has a unique serial number stamped on the rating plate which is hung on the back. Please record the serial number in the space below. You may also wish to attach your purchase receipt to this page for future reference.
MODEL NAME: Jøtul GF 300 DV Allagash Gas Stove
SERIAL NUMBER:_
DATE OF PURCHASE:____
AUTHORIZED DEALER:__
ADDRESS _____

PHONE: ____
INSTALLER:__
FUEL TYPE:____
FUEL CONVERSION: NO __ YES
NOTES:____
GF 300 DV Specifications
Input Rates
Natural Gas
26,000 BTU/hr. maximum input 14,000 BTU/hr. minimum input
Propane
26,000 BTU/hr. maximum input 14,000 BTU/hr. minimum input

Inlet Pressure: MIN MAX
Natural Gas: 5.0 WC (1.24 kPa) 7 7.0 WC (1.74 kPa)
Propane: 12.0 WC (2.99 kPa) 14 a) 14.9 WC (3.71 kPa)
Manifold Pressure MIN MAX
--- --- ---
Natural Gas: 1.2 WC (.30 kPa) 3.8 WC (.95 kPa)
Propane: 2.9 WC (.722 kPa) 11.0 a) 11.0 WC (2.74 kPa)

THIS FIREPLACE IS SHIPPED FROM THE FACTORY FOR USE WITH NATURAL GAS ONLY. IF USE WITH PROPANE IS DESIRED, THE APPLIANCE MUST FIRST BE CONVERTED USING THE FUEL CONVERSION KIT PROVIDED, #155372. CONVERSION SHOULD BE MADE BEFORE THE APPLIANCE IS INSTALLED. SEE PG. 17.JOTUL GF 300 DV Direct Vent Gas Stove
Steel Burner - fig 2

Unpacking your stove

  1. Inspect the shipping crate for damage and immediately notify your dealer if any evidence of damage is apparent.

  2. Remove the Top Plate of the stove by simply lifting it straight off of the stove body.

  3. To open the firebox, disengage the two Glass Frame Latches located on top of the firebox. Pull each handle forward to clear the latch from the notch in the frame.

  4. SAFETY BARRIER SCREEN: This appliance is equipped with a Certified Barrier Screen that must be installed before operating the unit. It is secured to the shipping
    pallet. Remove two screws and use pliers to break each shipping strap off of the frame at the perforation as shown in grey tint at right.
    Attach the barrier assembly to the stove front by engaging its mounting brackets over the stove door hinge bosses. The barrier may be installed with the stove doors
    either open or closed.

  5. Familiarize yourself with the installation requirements specified in this manual, before beginning the installation.
    Follow the assembly instructions in the order presented in this manual.

Hardware Bag Contents

  • Fuel Conversion Kit – LP ………………………………155372
  • Ember Stones , 4 oz. ………………………………….220702
  • Rock Wool , 1 oz. ………………………………………….157259

General Information

  • THIS HEATER MUST BE INSTALLED AND MAINTAINED BY A QUALIFIED SERVICE AGENCY.
  • The installation and repair of this appliance must be done by a qualified service person. Failure to properly install and maintain this heater could result in an unsafe or hazardous installation, which may result in a fire, explosion, property damage, personal injury or loss of life.
  • This appliance should be inspected before use and at least annually. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. It is imperative that control compartments, burners, and circulating air passageways of the appliance be kept clean.
  • THIS APPLIANCE MUST NOT BE CONNECTED TO A CHIMNEY OR FLUE SERVING ANY OTHER APPLIANCE.
  • The installation must conform to local codes. Your local Jøtul dealer can assist you in determining what is required in your area for a safe and legal installation. Some areas require a permit to install a gas burning appliance. Always consult your local building inspector, or authority having jurisdiction, to determine what regulations apply in your area.
  • CODE COMPLIANCE : Your local officials have final authority in determining if a proposed installation is acceptable. Any requirement that is requested by the local authority having jurisdiction, that is not specifically addressed in this manual, defaults to local code. In the absence of local codes, the installation requirements must comply with the current edition of National codes. In the U.S., these requirements are established in the National Fuel Code, ANSI Z223.1.(NFPA 54) current edition. In Canada, the codes have been established in CAN/CGA B149 Fuel Installation Code, current edition..
  • DO NOT OPERATE THIS STOVE IF ANY PART HAS BEEN UNDER WATER. Call a qualified service technician to inspect the heater and to replace any part of the control system and any gas control which may have been under water.

Safety Information

  • Due to the high operating temperatures this appliance should be located out of traffic and away from furniture, draperies, etc. Maintain proper clearance to combustible mantels and fireplace trim.

  • A certified Safety Barrier, designed to reduce the risk of burns from the hot viewing glass, is provided with this appliance and shall be installed for the protection of
    children and other at-risk individuals.

  • If the safety barrier becomes damaged, the barrier shall be replaced with the manufacturer’s barrier for this appliance, PN 157699.

  • Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition.

  • Young children should be supervised while they are in the same room as the appliance. Toddlers, young children and others may be susceptible to accidental contact burns. In addition to the certified Safety Barrier, a physical barrier, such as a child guard, is recommended to be used if there are at-risk individuals in the house. To restrict access to a fireplace or stove, install an adjustable safety gate to keep toddlers, young children and other at-risk individuals out of the room and away from hot surfaces.

  • Any safety screen, guard, or barrier removed for servicing an appliance must be replaced prior to operating the appliance.

  • Clothing or other flammable materials should not be placed on or near the fireplace.

  • Never allow anyone to use the fireplace if they are unfamiliar with its operation.

  • NEVER store or use gasoline or any other flammable vapors or liquids in the vicinity of this appliance.

  • Never burn any solid materials (wood, cardboard, paper, coal, etc.) in this appliance. Use with natural gas or propane fuel ONLY.

  • Do not slam or strike the glass panel.

  • This appliance is NOT for use with aftermarket glass doors.

  • Wear gloves and safety glasses while installing or performing maintenance procedures on this appliance.

Glass Panel
Do not operate this appliance with the glass front removed, cracked, or broken. Replacement of the glass should be done by a licensed or qualified service person. Only remove glass for routine service. Always handle glass carefully.
Location
In selecting a location for the stove, consider the following points: 1) Heat distribution 2) Vent termination requirements 3) Gas supply line routing 4) Traffic areas, furniture, draperies, etc. The GF 300 DV may be located on or near conventional construction materials, however, proper clearance to combustibles must be maintained in order to provide adequate air circulation around the appliance. Also, it is important to provide adequate access around the stove for servicing and proper operation. The clearance and hearth specifications listed in this manual are the minimum requirements for combustible material. A combustible material is anything that can burn (i.e. sheet rock, wall paper, wood, fabrics etc.). These surfaces are not limited to those that are visible and also include materials that may be located behind non-combustibles. If you are not sure of the combustible nature of a material, consult your local fire officials. Remember, “Fire Resistant” materials are considered combustible: they are difficult to ignite, but will burn. Also, “fire-rated” sheet rock is considered combustible.
Hearth Requirements
This appliance CANNOT be installed directly on carpeting, vinyl, linoleum or wood laminate flooring, such as Pergo .
If this appliance will be installed on any combustible ® material OTHER THAN WOOD, a floor pad must be installed that is either metal, wood, ceramic tile, stone, or a listed hearth pad. This floor protection must extend the full width and depth of the appliance. It is not necessary to remove carpeting, vinyl or linoleum from underneath the floor protection. See fig. 1.JOTUL GF
300 DV Direct Vent Gas Stove Steel Burner - fig3 Stove and Vent Clearance
Requirements

The clearances specified and diagrammed here are established from the stove body. The safety barrier has no affect on clearances to combustible material.
Minimum Clearances from the Stove to Combustibles: See figs. 2-3.

Rear: 2”  (51 mm)
Ceiling: 33”  (838 mm)
Corner: 2”  (51 mm)
Sides: 3”  (76 mm) Mfg. Serial No. after 30000
Left Side: 10”  (254 mm) Mfg. Serial No. before 30000

Minimum Clearances from the Vent Pipe to Combustibles:
Horizontal Run:
Off the top of the pipe 2” (51 mm)
Off the sides and bottom 1” (25 mm)
Vertical Run:
All sides 1” (25 mm)JOTUL GF 300 DV Direct Vent Gas Stove Steel Burner - fig
6JOTUL GF 300 DV Direct Vent Gas Stove
Steel Burner - fig 5JOTUL GF 300 DV
Direct Vent Gas Stove Steel Burner - fig7

Venting Requirements
The Jøtul GF 300 DV gas stove may be installed with a vertical or horizontal termination. The vent configuration must conform to the requirements described below and
be in accordance with the latest edition National Fuel Gas Code ANSI Z223.1.
This appliance is approved for use with vent systems from the following manufacturers:

  • M&G DuraVent, Inc. (Direct Vent Pro Series)
  • American Metal Products (Amerivent)
  • Security Chimneys International, Ltd. (Secure Vent)
  • Selkirk Metalbestos (Direct Temp)
  • Metal-Fab, Inc. (Sure-Seal Direct Vent)
  • Industrial Chimney Corp. (ExcelDirect)
  • Bernard Delsin Mfg. (Pro Form)
  • Olympia Chimney Supply, Inc. (Ventis Direct Vent)

Use parts of one manufacturer only – DO NOT MIX VENT COMPONENTS FROM DIFFERENT MANUFACTURERS IN THE SAME SYSTEM.
Installation of any components not manufactured or approved by Jøtul or failure to meet all clearance requirements will void all warranties and could result in property damage, bodily injury, or serious fire. The approved vent configurations described in this manual are derived from extensive testing under controlled laboratory conditions. Gas appliance performance can be negatively affected by variables present in the installation environment, i.e: atmospheric pressure, strong prevailing winds, adjacent structures and trees, snow accumulation, etc. These conditions should be taken into consideration by the installer and stove owner when planning the vent system design.
IMPORTANT

  • JOINT SEALING REQUIREMENT: APPLY A 1/8” BEAD OF HIGH-TEMPERATURE SEALANT OR MIL-PAC® TO THE MALE SECTION OF THE INNER VENT PIPE. THE CEMENT SHOULD FORM A SEAL BETWEEN THE INNER AND OUTER PIPES. SEE FIG. 5.
  • NEVER MODIFY ANY VENTING COMPONENT, OR USE ANY DAMAGED VENTING PRODUCT.
  • THE GAS APPLIANCE AND VENT SYSTEM MUST BE VENTED DIRECTLY TO THE OUTSIDE OF THE BUILDING AND NEVER ATTACHED TO A CHIMNEY SERVING A SOLID FUEL OR GAS BURNING APPLIANCE. EACH DIRECT VENT GAS APPLIANCE MUST HAVE ITS OWN SEPARATE VENT SYSTEM. COMMON VENT SYSTEMS ARE PROHIBITED.
  • IF THE VENTING SYSTEM IS DISASSEMBLED FOR ANY REASON, REINSTALL PER THE INSTRUCTIONS PROVIDED FOR THE INITIAL INSTALLATION.

Vent Restriction
The GF 300 DV is equipped with an Exhaust Restrictor Plate which enables you to regulate the flow of exhaust gas. The plate prevents overly strong draft that can cause poor combustion and weak flame picture. Follow the guidelines below, and on the following pages, to determine the correct restrictor plate setting for your particular installation configuration.
Exhaust Restrictor
The Exhaust Restrictor is an adjustable shutter located at the top right side of the firebox. It is adjusted by moving a pivot pin into one of four positions. It is set in the FULLY OPEN (D) position at the factory. See Fig. 7. The four positions correlate to the termination zones (A,B,C,D) diagramed in figures 9-12. Consult these Vent Window diagrams on pages 10-11 to determine the setting you should use. Additional restriction may be needed depending the overall vent height. If necessary, use Simpson Dura-Vent Restrictor Disk #929 or a similar part from the appropriate vent manufacturer.
Adjusting Exhaust Restrictor Plate:

  1. Use the Vent Window diagrams to determine which setting position to use.
  2. Remove the Top Plate.
  3. Locate the pivot pin at the right side of the firebox top. Use a 7 mm or 9/32 nut driver to loosen the nut on the pivot pin and then push the pin to the left to disengage it from the current factory-set position. Move the pin forward and into the slot appropriate for your specific vent configuration. See figs. 6 and 7.
  4. Tighten the lock nut and replace the Top Plate.

Vertical Vent Termination
The Jøtul GF 300 DV can be vertically vented through a ceiling or to a roof termination with the following guidelines:

  • The termination should fall within the shaded areas of the grids depicted in the Vent Window diagrams on pages 10 – 11.

  • Maximum Vertical run should not exceed 35 ft. (10.66 m).

  • Minimum Vertical run must be at least 8 ft. (2.43 m).

  • Maximum Colinear Horizontal run is 2 ft. (61 cm).

  • Vent Terminus Clearance: In no case shall any discharge opening on the cap be less than 18 in. (610 mm) horizontally from the roof surface.

  • Steep roofs, nearby trees, and predominantly windy conditions can contribute to poor draft and/or promote down-draft occurances.
    Increasing the height of the vent may alleviate these conditions.

  • Use Wall Straps to support an offset pipe run at intervals of three feet to avoid excessive stress on the offsets.

  • Elbows: Four 45°, or two 90° elbows may be used. Do not include the 45° elbow attached to the stove. Whenever possible use 45° elbows instead of 90° elbows as they are less restrictive to exhaust gas and intake air flow.

  • A firestop is required at every floor. The opening should be framed to 10″ X 10″ inside dimension.

  • Any venting that is exposed above the first floor, regardless of attic space or living space, must be enclosed. Always maintain the required 1″ clearance from
    all sides of the vertical vent system.

JOTUL GF 300 DV Direct Vent Gas Stove Steel Burner -
fig12

Vent Windows for Natural GasJOTUL GF 300 DV Direct Vent Gas Stove Steel
Burner - fig 8

  • ALL VENTING MUST TERMINATE (END) WITHIN ONE OF THE SHADED AREAS.

  • SET STOVE EXHAUST RESTRICTOR TO THE POSITION THAT CORRESPONDS TO THE VENT TERMINATION AREA IN THE DIAGRAM
    ABOVE. When termination is exactly on a division line, use the less restrictive position. For example, if termination is at 20 ft./10ft., restriction will be set at Position B.

  • ALWAYS MAINTAIN THE PROPER CLEARANCES TO COMBUSTIBLES.

  • UP TO FOUR 45° ELBOWS OR TWO 90° ELBOWS MAY BE USED IN ADDITION TO THE STARTER ELBOW. A HORIZONTAL RUN, HOWEVER,
    MUST BE REDUCED BY 5 FEET FOR EACH ADDITIONAL ELBOW, WHETHER 45° OR 90°.

  • *NG MINIMUM VENT IS 12” VERTICAL X 6” HORIZONTAL (NG ONLY).
    The circled letter designations in the vent diagram correspond to the Exhaust Restrictor Setting on the stove. First, determine which vent termination zone is appropriate for your installation and fuel type, then adjust the restrictor to the corresponding position as shown in figure 7, page 9.

COLINEAR VENT
JOTUL GF 300 DV Direct Vent Gas Stove Steel Burner -
fig20

  • VENTING MUST TERMINATE(END) WITHIN THE SHADEDAREA.
  • Adjust the Exhaust Restrictor to position B for any NG colinear termination.
  • Max. Offset: 2 ft. (610 mm)

Vent Windows for PropaneJOTUL GF 300 DV Direct Vent Gas Stove Steel
Burner - fig 19

  • VENTING MUST TERMINATE (END) WITHIN ONE OF THE DESIGNATED AREAS.
  • SET STOVE EXHAUST RESTRICTOR TO THE POSITION THAT CORRESPONDS TO THE VENT TERMINATION AREA IN THE DIAGRAM ABOVE. When termination is exactly on a division line, use the less restrictive position. For example, if termination is at 10 ft./5ft., restriction will be set at Position D.
  • ALWAYS MAINTAIN THE PROPER CLEARANCES TO COMBUSTIBLES.
  • UP TO FOUR 45° ELBOWS OR TWO 90° ELBOWS MAY BE USED IN ADDITION TO THE STARTER ELBOW. A HORIZONTAL RUN, HOWEVER,
    MUST BE REDUCED BY 5 FEET FOR EACH ADDITIONAL ELBOW, WHETHER 45° OR 90°

The circled letter designations in the vent diagram correspond to the Exhaust Restrictor Setting on the stove. First, determine which vent termination zone is appropriate for your installation and fuel type, then adjust the stove restrictor plate to the corresponding position as shown in Figure 7, page 9.

COLINEAR VENTJOTUL GF 300 DV Direct Vent Gas Stove Steel Burner - fig
18

  • VENTING MUST TERMINATE (END) WITHIN THE SHADED AREA.
  • Adjust the Exhaust Restrictor to position C for a vertical colinear termination.
  • Max. Offset: 2 ft. (610 mm)

Co-linear Vent Installation
This appliance may be vented through a masonry or Class A prefabricated chimney using a Co-linear Flexible lining system approved for use with a solid-fuel burning
fireplace. When installed in the manner described below, this system can improve the performance of the appliance in cold climate situations, as well as simplify the vent installation. See figs. 14 – 15.
These installation requirements must be followed:

  1. Use the guidelines for Co-linear Vent Termination appropriate for your gas type on pages 10 – 11.

  2. Prior to the installation the chimney flue must be thoroughly cleaned and inspected by a qualified chimney service person.

  3. Prefabricated chimneys must be UL 103 or ULC S-629 listed and have a minimum INSIDE diameter of 6 inches, (150 mm).

  4. This appliance may not be installed into a chimney flue serving any other appliance of any kind.

  5. The air intake pipe must extend into the chimney flue beyond the fireplace damper area, or directly connect to the termination cap.
    CANADA ONLY: Both the intake and exhaust ducts must fully connect the appliance and vent terminal.

  6. STUB INTAKE (fig. 14): If the intake flex duct does not extend the full length of the chimney to fully connect both the unit and termination cap, a sheet metal blockoff plate must be installed above the appliance before the end of the intake duct. The plate must completely seal the chimney flue from the living area.

  7. REVERSED INTAKE LOOP: When enough vent length and flue area are available, including a return loop in the air intake run can help prevent draft reversals that cause cold start problems. See Fig. 16.

  8. Consult with the local code authority having jurisdiction before proceeding with this type of installation.

  9. Refer to the vent  manufacturer’s instructions for specific installation requirements.

WARNING: FAILURE TO POSITION THE PARTS AND STOVE IN ACCORDANCE WITH THESE DIAGRAMS OR FAILURE TO USE ONLY PARTS
SPECIFICALLY APPROVED FOR USE WITH THIS APPLIANCE MAY RESULT IN PROPERTY DAMAGE OR PERSONAL INJURY. BE SURE TO MAINTAIN THE PROPER CLEARANCES TO COMBUSTIBLES AS DEFINED IN THIS MANUAL AND IN THE INSTRUCTIONS PROVIDED WITH EACH VENT COMPONENT.JOTUL GF 300 DV Direct Vent Gas Stove Steel Burner - fig
21JOTUL GF 300 DV Direct Vent Gas Stove
Steel Burner - fig22

Horizontal Termination

  • Any horizontal termination must fall within the shaded portion of the vent window graph illustrated in figs. 9 or 11. For Snorkel Terminations, see below.
  • Any horizontal termination except a snorkel termination, must include:
  1. Minimum verticle rise: NG – 12 in. / LP – 24 in.
  2. Minimum horizontal run:
    NG – 6 in.
    LP – 12 in. when vertical run is less than 8 ft.
  3. Vertical run no more than 35 ft.
  4. Horizontal run no more than 27 ft.
  •  Up to four 45° or two 90° elbows may be used in addition to the starter elbow. The horizontal run must be reduced by 5 feet for each additional elbow, whether 45° or 90°.

  • The horizontal termination cap must maintain a 3″ clearance to any overhead combustible projections 2 1/2″ or less. It must also maintain 12″ clearance from
    projections exceeding 2 1/2″. See fig. 21.

  • Wall Cut-out Opening: A minimum 10″ X 10″ (250 mm x 250 mm) square hole is required for proper pipe clearances through a combustible wall.
    DO NOT FILL AIR SPACE WITH ANY TYPE OF INSULATION.

  • Any horizontal run of vent must be level or have a 1/4 in. rise for every foot of run toward the termination cap. NEVER ALLOW THE VENTING TO RUN DOWNWARD FROM STOVE TO TERMINATION; DOWNWARD VENT RUNS TRAP HEAT AND CAUSE HIGH TEMPERATURES TO DEVELOP WITHIN THE VENT THAT COULD START A FIRE.

  • Install a Vinyl Siding Standoff (Simpson Dura-Vent #950) between the vent termination and an exterior wall covered by vinyl siding material to prevent potential
    heat damage to the siding.

  • Do not recess the termination cap into a wall or siding.

Snorkel Terminations

  • With a 14” Snorkel:
    The horizontal run made directly off the rear of the stove into a 14” snorkel cap should include no more than a single 12” straight section as shown in fig.
  1. One 45° Elbow may be used for a corner installation as shown in fig. 19.
  •  With a 36” Snorkel:
    The maximum horizontal run may be no more than 6 ft. (182 cm.)

  • Exhaust Restriction: Under normal circumstances, no exhaust restriction is recommended. Keep the factory setting (Position D – fully open with Baffle Wing
    removed, PN 226873).

  • Minimum vent for LP shown above. NG min. is 1 ft. x 6 in.

  • 14” Maximum horizontal run directly off rear of stove with 14” Snorkel termination, (Baffle Wing 226877 removed)

JOTUL GF 300 DV Direct Vent Gas Stove Steel Burner -
fig26JOTUL GF 300 DV Direct Vent Gas Stove
Steel Burner - fig27

| | Canadian Installations’| U.S. Installations 2
---|---|---|---
A| Clearance above grade, veranda, porch, deck, or balcony| 12 in. (3o cm)| 12 in. (3o cm)
B| Clearance to window or door that may be opened| 12 in. (3o cm)| g in. (23 cm) We recommend 12 in. to prevent condensation on a window.
C| Clearance to permanently closed window| 12 in. (3o cm)| 9 in. (23 cm) We recommend 12 in. to prevent
condensation on a window.
D| Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2 ft (6o cm) from the center line of the terminal| 18 in, (46 cm)| 18 in, (46 cm)
E| Clearance to unventilated soffit| 12 in,. (46 cm)| 12 in,. (46 cm)
F| Clearance to outside corner| 12 in,. (46 cm)| g in. (23 cm) We strongly recommend 12 in. particularly where strong winds prevail.
G| Clearance to inside corner| 12 in,. (46 cm)| g in. (23 cm) We strongly recommend 12 in. particularly where strong winds prevail.
H| Clearance to each side of center line extended above a gas meter or regulator| 3 ft. (91 cm) within a height 15 ft. above the meter/regulator assembly|
I| Clearance to service regulator vent outlet| ft.|
3 (91 cm)| 4
1| Clearance to nonmechanical air supply inlet to building or the combustion air inlet to any other appliance| 12 in. (3o cm)| g in. (23 cm)
K| Clearance to a mechanical air supply inlet| 6 ft. (1.83 m)| 3 ft. (91) cm above if within io ft. (3 m) horizontally
| Clearance above paved sidewalk or paved driveway located on public property| 7 ft. (2.13 fil) 3|

M| Clearance under veranda, porch, deck, or balcony| 12 in. (3o cm) 4| 12 in. (3o cm) 4
N| Clearance to propane tank relief valve and filler connection| 5 ft. (1.52 m) 5 / 10 ft. (3.05 ITO 6| 5 ft. (1.52 m) 5 / 10 ft. (3.05 rn) 6

  1. In accordance with the current CSA B149.1, Natural Gas and Propane Installation Code.
  2. In accordance with ANSI Z223.1/MNPA 54, National Fuel Gas Code
  • For clearances not specified in ANSI Z223.1/NFPA or CSA B149.1, the clearance will be in accordance with local installation codes and the requirements of the gas supplier. 3. A vent shall not terminate directly above a sidewalk or driveway which is located between two single family dwellings and serves both dwellings. 4. Permitted only if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the floor. 5. Minimum clearance to tanks not filled on site. 6. Minimum clearance to tanks filled on site from bulk truck.

Mobile Home Installation
The GF 300 DV can be installed for use in a mobile home in the U.S. and Canada provided:

  1. The stove is secured to the floor of the mobile home.
    Use Jøtul Floor Bracket Kit #750304.

  2. Provision must be made to secure an electrical ground between the stove and the mobile home chassis.

  3. The stove is installed in accordance with Title 24 CFR, Part 3280- Manufactured Home Construction and
    Safety Standard, in the U.S. In Canada, comply with CSZ240.4, Gas Equipped Recreational Vehicles and Mobile Housing.

  4. Always contact your local officials about installation restrictions and requirements in your area.

THIS APPLIANCE MAY BE INSTALLED AS AN OEM INSTALLATION IN A MANUFACTURED (MOBILE) HOME AND MUST BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER’S INSTRUCTIONS AND THE MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARD, TITLE 24 CFR, PART 3280. THIS APPLIANCE IS ONLY FOR USE WITH THE TYPE OF GAS THAT IS INDICATED ON THE STOVE’S RATING PLATE. A GAS CONVERSION KIT IS PROVIDED WITH THE GF 300 DV GAS STOVE. THIS APPLIANCE MAY BE INSTALLED IN AN AFTERMARKET PERMANENTLY LOCATED, MANUFACTURED (MOBILE) HOME, WHERE NOT PROHIBITED BY LOCAL CODES. CET APPAREIL PEUT ETRE INSTALLE DANS UN MAISON PREFABRIQUEE (MOBILE) DEJA INSTALLEE A DEMEURE SI LES REGLEMENTS LOCAUX LE PERMETTENT. CET APPAREIL DOIT ETRE UTILISE UNIQUEMENT AVEC LES TYPES DE GAS INDIQUES SUR LA PLAQUE SIGNALETIQUE. NE PAS L’UTILISER AVEC D’AUTRES GAS SAUF SI UN KITDE CONVERSION CERTIFIE EST INSTALLE.
Fuel Conversion
The GF 300 DV gas stove is shipped from the factory equipped to burn NATURAL GAS only. If PROPANE gas is to be used as fuel, the appliance must first be converted
for use with propane. Use Propane Conversion Kit 155372, supplied with the appliance.
Order and install NG Conversion Kit 155373 to change back to use with natural gas.
WARNING: THE CONVERSION KIT IS TO BE INSTALLED BY AN AUTHORIZED SERVICE TECHNICIAN IN ACCORDANCE WITH THE MANUFACTURER’S INSTRUCTION AND ALL CODES AND REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN SERIOUS INJURY OR PROPERTY DAMAGE. THE QUALIFIED AGENCY PERFORMING THIS WORK ASSUMES RESPONSIBILITY FOR THIS CONVERSION.
IN CANADA: THE CONVERSION SHALL BE CARRIED OUT IN ACCORDANCE WITH THE REQUIREMENTS OF THE PROVINCIAL AUTHORITIES HAVING JURISDICTION AND IN ACCORDANCE WITH THE REQUIREMENTS OF THE CAN1-B149.1 AND .2 INSTALLATION CODE.
Tools required:

  • 1/2” open ended wrench or deep-well socket, Torx T20 or slotted screwdriver, 4 mm allen wrench.
    Conversion Kit Contents:

  • 1, regulator tower labeled for propane

  • 3, regulator tower screws

  • 1, burner orifice (#39 for NG, #53 for LPG)

  • 1, pilot orifice (#51 for NG, #30 for LPG)

  • Label A – to be completed and applied to the back of the stove

  • Label B – apply to the stove’s Rating Plate

  • Small valve label – apply to valve body Conversion instructions are also shipped in the stove with the conversion kit.

Fuel Conversion Procedure

  1. Turn off gas supply to stove.

  2. Remove the stove Top Plate.

  3. Disengage the two Glass Frame Latches at the top of the firebox. See illustration on page

  4. Carefully lift the glass panel up and out of the stove.

  5. If installed, remove the Embers and Log Set using care not to damage the fragile log parts.

  6. Lift out the Burner Skirt- (Part 40, fig. 52 p.28).

  7. Reach under the stove and remove the Air Shutter wingnut from its stud. As you face the right side, it is the one closest to you. See fig. 22.

  8. Lift out the Burner Plate: NOTE- There are no screws securing the Burner to the floor of the firebox. Pull the Air Shutter forward and lift the burner together with shutter up and out of the stove as a unit. See fig. 23.

  9. Change the Main Burner Orifice. See fig. 24. Using a ½” open ended wrench or deep-well socket remove the burner orifice from its brass elbow housing and replace with the appropriate orifice supplied in the kit.

  10. Replace the Air Shutter with its gasket and push it all the way back to allow replacement of the Burner Plate. Reattach the wingnut to the shutter stem under the stove, but do not tighten. You will set its final position later.

  11. Replace the Burner Plate. Engage the burner tube with the Air Shutter assembly as in fig.

  12. Be sure the burner is securely engaged with the two support brackets at the front of the firebox and push the plate back toward the rear of the firebox. When correctly positioned, there will be 1/2” (13 mm) clearance between the burner plate and the front of the firebox. See fig. 25.

  13. FOR LP ONLY: REMOVE THE BAFFLE WING: The wing is detached from the back of the Exhaust Baffle with removal of the single sheet metal screw. Retain the Wing for potential future use. See fig. 25a.

  14. CHANGE THE PILOT ORIFICE: From within the firebox, remove the Pilot Head by pulling it straight up from the pilot base. See fig. 26, page
    JOTUL GF 300 DV Direct Vent Gas Stove Steel Burner -
fig28

  15. Using the 4 mm hex key included with the kit, unscrew the pilot orifice (counterclockwise). Replace with the appropriate orifice.

  16. Tighten the orifice into the base of the pilot assembly. To prevent bypass leaks, be sure the orifice is secured tightly and flush with the base. Replace pilot head by pushing it down onto the pilot base.

  17. Replace the Variable Regulator. Using a Torx T-20 screwdriver, remove the three screws from the front of the valve regulator. See fig. 27.
    Remove the Regulator Tower, Gasket, white plastic disk, and Spring. Remove the black rubber gasket from the valve. See fig. 27.

  18.  Install the new regulator: Be sure the new gasket is properly positioned and tighten screws securely.

  19. Install the identification labels to the stove so that they can be seen by any person who may be servicing the stove.
    Label A: apply to back of stove.
    Label B: apply to the rating plate attached to the back of the stove.
    Small Conversion Label: apply to valve.

  20. Reassemble the stove, apply gas to the system and check for leaks using a soapy water solution or gas detector.
    NEVER USE AN OPEN FLAME TO CHECK FOR GAS LEAKS.

  21. Correct gas pressure is essential for efficient and safe operation of this appliance. Use a manometer to check pressures as specified in the Gas Pressure section of
    this manual (page 19).

  22. Adjust the Air Shutter. You will need to position the shutter to provide a gas/air mixture that will achieve the best flame picture with your particular installation.
    Start with the shutter stem at the half-way position in the slot in the bottom of the stove. See figs. 22 and 25. Pushing the stem back will restrict air, while pushing
    it forward will open the shutter and increase air. With some experimentation, you will find the shutter position that works best for your installation.
    ALWAYS REFER TO THE LIGHTING INSTRUCTIONS ON THE INSIDE BACK COVER OF THIS MANUAL WHEN LIGHTING YOUR STOVE.

Gas Supply Connection
NOTE: If appropriate, install the optional forced air blower before connecting the gas line, to prevent clearance interference between the two.
The gas supply line connection is made to the left side of the valve. The gas supply line should be 3/8” npt with a 1/2” diameter supply, or the appropriate size to provide sufficient gas pressure to the valve regardless of the input setting.
The use of Flexible Gas Appliance Connectors is acceptable in many areas in the U.S. However, Canadian methods vary depending on local code.
ALL INSTALLATIONS MUST COMPLY WITH LOCAL CODE OR IN THE ABSENCE OF LOCAL CODE, MUST COMPLY WITH THE MOST RECENT EDITION OF THE NATIONAL FUEL GAS CODE ANSI Z223.1/NFPA 54 OR CAN-B149.
All codes require a gas shut-off valve (gas cock) and union, to be installed in the supply line, and in the same room as the appliance. This allows for the disconnection
of the stove for servicing and maintenance. See fig. 28.
A T-HANDLE GAS COCK IS REQUIRED IN MASSACHUSETTS TO COMPLY WITH CODE 248CMR. Secure all joints tightly using appropriate tools and sealing compounds. For propane units be sure to use compounds that are propane resistant. Turn on gas supply and test for gas leaks using a soapy water solution. Never use an open flame to check for leaks.

Leak test:

  1. Mix a 50-50 solution of water and dish soap.
  2. Light appliance- see lighting instructions on the inside back cover of this manual or on the stove’s rating plate.
  3. Brush or spray all joints and connections with the soapy water solution.
  4. If bubbles appear at any connection or seam or a gas odor is detected, immediately turn  gas control knob to the OFF position.
  5. Tighten or reconnect the leaking joint and retest for any gas leaks.

Gas Pressure
Correct gas pressure is essential for efficient and safe operation of the GF 300 DV gas stove. It is important that the correct pressure is established at the time of the installation. Proper gas pressure provides a consistent flow of gas to the appliance and is instrumental in checking for gas leaks. Pressure Test: Attach a manometer to the appropriate test point on the valve. See fig. 29. The gauge connections are located on the front of the valve under the On/Off/Pilot- knob. Gauge connections are identified by: E – for Inlet or Supply Pressure (the amount of gas coming to the valve.) A – for Manifold Pressure (the amount of gas that is coming out of the valve to the burner.) ALWAYS TEST PRESSURES WITH VALVE CONTROL KNOB SET ON HIGH.

INLET GAS PRESSURES
(inches water column)
MIN MAX
NATURAL GAS 5.0 7.0
PROPANE 12.0 14.9
The appliance and its appliance main gas valve must be disconnected from the gas supply piping system during any pressure testing on that system at test pressures in excess of 1/2 psig (3.5 kPa). The appliance must be isolated from the gas supply line by closing its individual manual gas shut-off valve (gas cock) during any pressure testing
of the gas supply piping system that is equal to or less than 1/2 psig (3.5 kPa).
MANIFOLD PRESSURES
(inches water column)
MIN MAX
NATURAL GAS 1.2 3.8
PROPANE 2.9 11.0
High Altitude Adjustment
Installations located at altitudes from 2000 – 4500 ft.
(610 m -1370 m) DO NOT require adjustment for altitude.
DO NOT DERATE THIS APPLIANCE FOR ALTITUDE.
Flame Appearance / Air Shutter Adjustment
The GF 300 DV gas stove is shipped from the factory equipped to burn Natural gas. If the stove has been converted for use with propane, the Air Shutter may
require adjustment to achieve the desired flame appearance. Other installation related variables can also affect the flame picture. The Air Shutter may be opened or
closed to provide the best flame picture for your specific installation.
Too large an air opening – the appliance will generate a flame that is blue and transparent, or an “anemic” flame. Too small an air setting – the appliance will generate
very long yellow flames resulting in soot. Sooting produces black deposits on the logs, on the inside walls of the appliance, and potentially on the exterior termination
cap. Sooting is caused by incomplete combustion in the flames and lack of combustion air entering the air shutter opening.

To adjust the air shutter:

  1. Reach under the right side of the stove and loosen the wingnut located closest to you. See fig. 30. Slide the wingnut stud forward to open the air shutter and back to provide less air. Make adjustments in small increments.
  2. Tighten the wingnut to secure the shutter at the desired setting.
  3. Allow the stove to burn for 30 minutes on the HIGH setting, observing the flame continuously. If the flame appears weak, slow, or sooty, repeat the process described above until the flame is as desired.

WARNING: AIR SHUTTER ADJUSTMENTS SHOULD ONLY BE PERFORMED BY A QUALIFIED PROFESSIONAL SERVICE TECHNICIAN.

Optional Wall Thermostat or Remote Control
Use only a 750 millivolt DC two-wire circuit thermostat with this appliance. The thermostat should be placed in the same room as the heater, typically 5 feet off the floor. Avoid drafty areas or any area that may affect the accuracy of the thermostat.
The thermostat should be connected using a minimum of 16 gauge wire with a maximum length of 25 feet of wire.
Connect the two thermostat wire leads to the two lower terminals on the terminal block located directly above the ignitor button. Do not overtighten the
connections. IT IS NOT NECESSARY TO DISCONNECT ANY OTHER WIRES. See Fig. 31.
For thermostatic operation, the On/Off/T-Stat switch on the back of the stove must be in the T-stat position, and the pilot light must be running, as it is the power source for the thermostat.
At the thermostat, the two wires should be connected to the two connection screws on the thermostat base plate per the manufacturer’s instructions.
Remote Control
A remote receiver should be wired to the terminal block the same way the thermostat would be. See the instructions above. Follow the operating instructions included with the Remote Control unit.
CAUTION:
LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING THE CONTROLS. WIRING ERRORS CAN CAUSE IMPROPER OR  DANGEROUS OPERATION. ALWAYS VERIFY PROPER OPERATION AFTER SERVICING THE APPLIANCE.

CRITICAL NOTE: THE RED THERMOPILE WIRE MUST BE CONNECTED TO THE VALVE TH/TP TERMINAL TO POWER THE THERMOSTAT.
Log Set Installation
Brick Kit Note: Install the optional Antique Brick Kit 155370 before installing the log set. See page 27 and the instructions provided with that kit.
The GF 300 DV log set must be installed before operating the burner. The log set includes four log pieces, packaged inside the firebox, and a quantity of ember stones packaged in the Miscellaneous Parts bag. To install the log set, remove the packaging and place the parts inside the firebox as illustrated in figs 32-36.
Do not handle the log set with your bare hands. Always wear gloves to prevent skin irritation from the ceramic fibers.
IMPORTANT
The ember stones realistically simulate glowing coals when the burner is operating. These should be spread evenly over the burner plate and around the logs.
TO INSURE PROPER BURNER FUNCTION, DO NOT OBSTRUCT THE PILOT ASSEMBLY AND BURNER SKIRT OPENINGS WITH EMBER STONES.
KEEP EMBERS OFF OF THE PILOT CARRY-OVER PORTS. SEE FIG. 36.
You do not need to use all of the ember stones. With some experimentation, you will find the arrangement and quantity of embers that works best with your stove. Depending upon the characteristics of your installation, it is possible that too many ember stones can promote sooting on the logs. Adjust the quantity of ember stones as appropriate to maintain the best overall flame picture and burner performance.JOTUL GF 300 DV Direct Vent Gas Stove Steel
Burner - fig 43

System Check

  1. PURGING THE GAS LINE: When lighting the appliance for the first time, it will take a few moments to clear the gas line of air. Once this purge is complete, the appliance will operate as described in the lighting instructions. From a cold start, it may be helpful to let the pilot light burn for 10 – 15 minutes to establish positive draft, before turning the burner on. See the inside back cover of this manual or the stove Rating Plate attached to the rear shroud. Subsequent burner starts will not require purging the gas line unless the supply line is shut off.
  2. PILOT FLAME: You can monitor the pilot flame through the view port located at the rear of the RightLog. See fig. 37. The pilot flame should be steady – notlifting or floating. The flame should be blue in color around the pilot hood, with traces of yellow toward the outer edges. The pilot flame should engulf the top 3/8” of the thermopile (to generate millivolt current) and the top 1/8” of the thermocouple. The pilot flame should project out of all three pilot hood ports 1” and over to the burner plate carry-over ports. See figs. 37 and 37a.
  3. BURNER ADJUSTMENT: This stove is equipped with a variable gas control valve that allows easy adjustment of the flame height and heat output. To adjust the flame intensity, rotate the HI/LOW knob. Flame height will adjust approximately 50% between the LOW and HIGH settings. See fig. 38. NO SMOKE OR SOOT SHOULD BE PRESENT. CHECK LOG PLACEMENT IF ANY SOOT OR SMOKE IS PRESENT.IF SOOT OR SMOKE PERSISTS, THE AIR SHUTTER MAY NEED TO BE ADJUSTED. See Air Shutter/Flame Appearance section of this manual for proper air shutter settings and adjustments. Note: the more offsets there are in the vent system, the greater the need for an air shutter adjust- ment. See page 20.

WARNING: AIR SHUTTER ADJUSTMENTS SHOULD ONLY BE PERFORMED BY A QUALIFIED PROFESSIONAL SERVICE TECHNICIAN.JOTUL GF 300 DV Direct Vent Gas Stove Steel
Burner - fig44 CAUTION: DO NOT ATTEMPT TO ALTER THE FLAME APPEARANCE BY POSITIONING THE GAS VALVE CONTROL IN ANY OTHER POSITION OTHER THAN THE FULL “ON” POSITION.JOTUL GF 300 DV Direct Vent
Gas Stove Steel Burner - fig45

Operation

Familiarize yourself with the controls of the GF 300 DV. Make sure that anyone else using the appliance is also familiar with the controls and operation procedures. Always follow the Lighting Instructions on the inside back cover of this manual and also located on the Rating Plate attached to the rear shroud.

  1. Once the pilot is lit, burner operation is controlled by the rocker switch located at the left corner of the rear shroud. See fig. 39. ON / OFF – use for manual control of the burner. T-STAT – use for optional thermostatic or remote control operation. The burner will be controlled by those accessories.
  2. During the first few fires, you may notice odor and/ or smoke from the stove. This is normal and results from burn-off of manufacturing residue and curing of materials. You may find it helpful to provide additional ventilation and fresh air to alleviate this condition.
  3. Condensation may occur on the glass upon each lighting of the appliance. This “fog” will disappear as the appliance heats up.
  4. Keep the controls and the area under the appliance free of debris, vacuum this area frequently. Always keep the appliance area clear and free from combustible materials, gasoline and other flammable liquids. If a vacuum is used during any service on the stove, ALWAYS be sure the stove is cold and there are NO hot embers.
  5. Remember, this appliance has a continuous burning pilot flame. Exercise caution when using products having combustible vapors. Always shut-off gas supply while servicing the stove.
  6. CAUTION: DO NOT OPERATE THIS APPLIANCE WITH THE GLASS REMOVED CRACKED OR BROKEN. Replacement of the glass should be done by a licensed or qualified service person. Use only replacement glass provided by your authorized Jøtul dealer. Never use any substitute materials. WARNING: OBSERVE CAUTION WITH THE GLASS. THE GLASS PANEL MAY SHATTER UNEXPECTEDLY IF STRUCK WITH AN OBJECT. ALWAYS HANDLE THE GLASS PANEL WITH CARE. WHEN SERVICING THE STOVE ALWAYS PULL THE GLASS ASSEMBLY STRAIGHT UP FOR REMOVAL.
  7. Clean the glass only when necessary. Wipe surface with a clean, damp soft cloth. Follow with a dry, soft towel as desired. Take care not to scratch the glass surface. WARNING: DO NOT USE ABRASIVE CLEANERS ON THE GLASS. NEVER CLEAN THE GLASS WHEN IT IS HOT.

JOTUL GF 300 DV Direct Vent Gas Stove Steel Burner -
fig46

Maintenance

Your Jøtul GF 300 DV Allagash and its venting system should be inspected before use and at least annually by a qualified service technician.
Use the form on page 30 to keep a maintenance history of your stove.
IMPORTANT: ALWAYS TURN OFF THE GAS SUPPLY TO THE FIREPLACE AND UNPLUG THE FORCED AIR BLOWER BEFORE ANY SERVICE WORK IS PERFORMED ON THE FIREPLACE.

Annual Cleaning

Vent System
The entire vent system, including the chimney, should be inspected and cleaned every year. If the intake and exhaust venting is disassembled for any reason, it should be reassembled and sealed according to the manufacturer’s instructions provided at the initial installation.
Firebox Components
Periodically inspect the Firebox, Valve Compartment, Convection Airways and optional Blower to BE CERTAIN THAT THE FLOW OF COMBUSTION AND VENTILATION AIR IS UNOBSTRUCTED.

  • The firebox should be vacuumed annually to remove any surface build up. Use a soft brush attachment and handle the logs carefully as they are fragile.
  • Inspect the pilot head, thermopile and thermocouple for signs of rust or deterioration and replace any components that do. Check that the pilot head is properly engaged with the throat and is oriented correctly. See fig. 37, page 22.
  • Inspect the burner and confirm that all the ports are unobstructed, particularly at the pilot area. Vacuum the burner plate if necessary.

Glass Care
Clean the glass only when necessary. Wipe the surface with a clean, dampened, soft cloth. Follow with a dry, soft towel. Take care not to scratch the glass surface. WARNING: DO NOT USE ABRASIVE CLEANERS ON THE GLASS. NEVER CLEAN THE GLASS WHEN IT IS HOT. Gasket Inspection It is important that the glass gasket be inspected at least annually. Examine the ribbon gasket for signs of deterioration and make sure the gasket has a positive seal. Replace the gasket if necessary. Refer to the replacement parts list on page 29.
NOTE: INSPECT THE GLASS SURFACE FOR SCRATCHES AS THESE CAN WEAKEN THE PANEL TENSILE STRENGTH. REPLACE THE PANEL IF ANY SCRATCHES ARE FOUND. USE ONLY JOTUL PN 220576. DO NOT USE ANY OTHER TYPE OF GLASS.

Glass Panel or Gasket Removal

  1. Lift the Top Plate off of the stove.
  2. Release the two Glass Frame Latches. Pull each latch handle forward forward to disengage the latch from the notches in the glass frame.
  3. Lift the glass frame all the way up and out of the top of the stove. Lay this assembly on a flat surface, protecting the frame from scratches using a blanket or towel.
  4. The glass panel is held in place by four compression clips. Use a screwdriver or small pliers to pry these up off the edge of the glass retaining walls. See fig. 40.
  5. Remove the old gasket material. See fig. 41.

Glass Panel or Gasket Replacement

  1. Wrap the new gasketing material evenly around the edge of the glass, peeling back the protective strip to expose the adhesive as you go. Press the adhesive side down onto the glass surface. Do not stretch the gasket.
  2. Place the gasketed glass within the frame and press each of the retainer clips back into place on the retainer walls.

JOTUL GF 300 DV Direct Vent Gas Stove Steel Burner -
fig47

Optional Blower # 156000
Read these instructions before beginning the installation. Due to design changes, the wire harness orientation may differ from that illustrated here. If that is the case, use the instructions provided with the blower kit.

  1. Unpack and check the contents of the blower kit. The kit includes two Air Deflectors and two #7 x 1/2” screws that will not be used with the GF 300 DV Allagash stove. Contact your dealer if any damage is evident or parts are missing. See fig. 42.
  2. Install the Snapstat by sliding it all the way into the slot in the bottom of the Snapstat Bracket as shown in fig. 43.
  3. Attach the Snapstat Bracket to the studs located in the middle of the firebox floor using the two M6 hex nuts and a 10 mm wrench. See fig. 43. 4. Attach the Blower Bracket to the stove using the two M6 flange head hex bolts as shown in fig. 43.
  4. Install the Blower with the duct openings oriented up and to the rear. See fig. 44. Feed the snapstat wire harness through the bracket opening and secure the blower to the bracket with the wingscrew. Route the controls wire harness over to the female quickconnector already installed in the stove.
  5. Attach either Snapstat wire connector to either Snapstat terminal. See fig. 44.
  6. Connect the male Control Switch connector to the female control switch wire harness already installed in the stove. See fig. 44. 8. Connect power cord to outlet.
  • Do not connect blower to power supply until all wire connections have been made.

  • This blower must be electrically grounded in accordance with local codes or, in the absence of local codes, with the current ANSI/NFPA 70, National Electrical Code or CSA C22.1Canadian Electrical Code.

  • This unit is supplied with a three-prong (grounding) plug for protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle.
    DO NOT CUT OR REMOVE THE GROUNDING PRONG FROM THE PLUG.

  • Always disconnect the power supply when performing any service on the fireplace insert.

Contents:

  1. Blower
  2. Mounting Bracket
  3. Snapstat Wire Harness
  4. Control Switch Wire Harness
  5. Snapstat
  6. Snapstat Bracket
  7. M6 x 1 x 20 Flange Nuts (2)
  8. M6 x 12 Hex Head Flange Bolts9. M6 x 12 Wingscrew
  9. Air Deflectors
  10. 7 X 1/2” sheet metal screws

Tools Required:

  • 10 mm wrench
  • short phillips screwdriver
  • Safety goggles
  • Work gloves

Figure 42. 156000 Blower Kit Components used for GF 300 DV Allagash.

Figure 44. Orient and attach Blower to the Mounting Bracket with the wingscrew and connect wires to Snapstat and female control quick connect.JOTUL GF 300
DV Direct Vent Gas Stove Steel Burner - fig50

Blower Operation
The optional variable-speed blower will enhance heat circulation around the firebox and out into the room. The blower is controlled by a heat activated switch (snapstat) that will ONLY function when the control switch is in AUTO setting. After the fire has been burning for a time, the snapstat will react to the heat and activate the blower. Fan speed may be manually adjusted with the rheostat knob. If the burner turns off, the blower will be shut off automatically when the stove cools down. If automatic blower circulation is not desired, place the blower control switch in the MANUAL position.JOTUL GF
300 DV Direct Vent Gas Stove Steel Burner - fig51

Optional Antique Brick Kit # 155648
CAUTION! THE BRICK PANELS AND LOG PARTS ARE EXTREMELY FRAILE. HANDLE WITH CARE. Read these instructions before beginning the installation.

  1. Remove the Top Plate. Simply lift it up off of the stobody. It is not fastened.
  2. Remove the Glass Frame. Disengage the two compression latches located at the top of the firebox and lift the glass frame up and off of the stove. See fig. 48.
  3. . If installed, remove the Logset. These parts are not fastened. Simply lift them out of the firebox. You do not have to remove the embers.
  4. Install the Lower Rear Panel. Position it up against the back wall, resting on the burner skirt. Fig. 49.
  5. Install a Side Panel. Tilt the panel, bottom edge first,into position against the side wall. The panel will stand on its own against the wall, fitting snugly between the rear panel and the front wall of the fireboFig. 50.
  6. Install the Upper Rear Panel. Simply rest it on the other two panels. Fig. 51.
  7. Install the other Side Panel.
  8. Reinstall the Logset. Refer to the Owner’s Manual if necessary. BE CERTAIN THAT NO EMBER STONES ARE BLOCKING THE PILOT ASSEMBLY OPENING. Refer to fig. 36.
  9. Replace the Glass Frame. Slide the frame down the slot in the front of the firebox. Be sure to push the frame into the slot in the bottom to ensure it is fully seated. The gasket at the top of the frame should be flush with the top of the firebox. Pull the compression latches out to engage with the top lip of the glass frame.
  10. Replace the Top Plate.

JOTUL GF 300 DV Direct Vent Gas Stove Steel Burner -
fig55

JOTUL GF 300 DV Direct Vent Gas Stove Steel Burner -
fig56

GF 300 DV Allagash Parts List

Cast Iron Parts| Matte Black| Blue Black Enamel| Ivory Enamel| Brown Majolica Enamel| Linen Enamel
---|---|---|---|---|---
1.Top Plate| 10463192| 10463127| 10463129| 10463147| 10463154
2.Side Plate| 10463292| 10463227| 10463229| 10463247| 10463254
3.Base Plate| 10390092| 10390027| 10390029| 10390047| 10390054
4.Legs, (4)| 10192592| 101966| 102251| 10192547| 10192554
5.Front Assembly *| 15746192| 157462| 157463| 157464| 158157
After SN 33600| 15769892| 157717| 157718| 157720|
6.Right Door| | | | |
7.Left Door| | | | |
82. Safety Screen Barrier| 157699| n/a| n/a| n/a|

ONLY USE REPLACEMENTS PARTS PROVIDED BY AN AUTHORIZED JØTUL DEALER.

  • Front Assembly includes 5, 6, 7, 75, and 76.
  1. Simpson DuraVent Collar…………………………………… 129126
    10. Collar Gasket ………………………………………………………..129118
    11. Rheostat ……………………………………………………………. 220970
    12. Rating Plate ……………………………………………………….. 220612
    13. Lanyard ……………………………………………………………….. 129159
    14. Rear Shroud ……………………………………………………….220594
    15. Valve Bracket ……………………………………………………….220721
    16. Valve – NG / High Temp …………………………………….. 222263
  2. Elbow, 3/8” Brass ………………………………………………… 129129
    18. Terminal Block ……………………………………………………. 129154
    19. Bracket, Terminal Block ……………………………………… 220614
    20. Gas Line, 5/16” x 18” Flex …………………………………….. 154372

  3. Orifice Holder, Straight …………………………………… 220643

  • Glass/Gasket Replacement Kit ………………………..155599
  1. Glass Panel, Ceramic …………………………………………220576
    24. •Glass Gasket, 7/16” Tadpole, 6 ft. …………………….. 129124
  2. Glass Frame, Matte Black …………………………….22032792
    26. Glass Clips, (4) ………………………………………………….. 220042
    27. Door Latch………………………………………………………….220604
    28. Control Door, Matte Black ………………………………. 22118792

Control Door, Jøtul Iron Gray ………………………….. 22118785
29. Wingnut
………………………………………………………………117975
30. Air Shutter Gasket …………………………………………….. 220734
31. Pilot Assembly Gasket ………………………………………. 129670
32. Pilot Assembly Spacer Weldment ……………………..226978
33. Pilot Assembly, w/NG orifice ……………………………….129471
34. Pilot Orifice NG #51 …………………………………………….129472

Pilot Orifice LP #30 ……………………………………………. 129473
35. Pilot Line w/ Fitting …………………………………………… 129446
36. Thermocouple ……………………………………………………. 129766
37. Electrode ……………………………………………………………..129765
38. Thermopile ……………………………………………………….3094527
39. Steel Burner Assembly ………………………………………..158271

Crimped Burner Replacement Kit……………………….158227
40. Burner Skirt, Matte Black ……………………………..22076692

Burner Skirt, Jøtul Iron …………………………………22076685
41. Exhaust Baffle ………………………………………………… 22054192
41a. Exhaust Baffle Wing ……………………………………… 22687392
42. Exhaust Restrictor …………………………………………….. 220543
43. Exhaust Restrictor Gasket ……………………………….. 220734
44. Firebox Assembly ……………………………………………….222005
45. Latch Assembly ………………………………………………….220091
46. Relief Door Gasket ……………………………………………..220735
47. Relief Door, Matte Black ………………………………..22058992
48. Relief Door Guide ………………………………………………129499
50. Inner Shroud, ……………………………………………………..220593
51. Rear Shroud, Matte Black ………………………………22071892
52.
Ignitor Bracket …………………………………………………3902576
53. Ignitor ………………………………………………………………. 3902573
54. Burner Orifice, NG #39 ……………………………………….129367

Burner Orifice, LP #53 …………………………………………. 220731

| 55. Primary Air Shutter …………………………………………….220791
56. Jam Nut – Orifice Holder ……………………………………..129152
57. Ferrule, 5/16” (2) ……………………………………………….. 129463
58. Nut , 5/16” (2) ……………………………………………………. 129464
59. Log Set, Complete ………………………………………………. 155584
60. Rear Log ……………………………………………………………… 220727
61.
Left Log …………………………………………………………….. 220728
62. Right Log ………………………………………………………….. 220729
63. Middle Log ……………………………………………………….. 220730
64. Gas Valve Assembly ………………………………………… 226560
65. Embers, 6 0z. (included in Logset) …………………….220702
66. Wire Harness Assembly ……………………………………..156001
67. Rocker Switch, 2 ……………………………………………….. 220703
68. Rheostat Knob …………………………………………………. 220709
69. Retaining Collar …………………………………………………. 220717
70. Spacer, .375 o.d x .172 …………………………………………..118039
71. Spacer, .375 o.d. x 3.172 ……………………………………… 118040
72. Fender Washer .250 x 1.50 dia. ………………………….. 118029
73.
Bolt, M6 x 130 mm Hex Hd ……………………………….. 118033
74.
Bolt, Hex Hd – M6 x 20 Ser. Flanged ……………………..117117
75. Door Hinge Pin , Blk ……………………………………………. 127075

Door Hinge Pin, Nickel ……………………………………… 125960
76. Washer, Hinge 12mm OD x 6mm ID …………………… 11758
77.
Bolt, Hex Hd – M6 x 16 Ser. Flanged …………………….99625
78 Washer, Fender M6 DIN 9021 Zinc ………………….. 120004
79.
Bolt, Hex Hd – M6 x 25 Ser. Flanged …………………… 118019
80. Cap, Hi-Temp Vinyl, .375” ID x .250” DP …………….224905
81. Magnet, .375” Dia. x .25” Neo. Hi-temp……………. 224909
82. Safety Screen Barrier ………………………………………… 157699

  • Misc. Kit ……………………………………………………………..155575

  • Wire, Terminal Block Jumper – 3” Blue ……………..155557

*Fender Washer, .250 x 2.250 ……………………………… 118023

  • Orifice Retainer ………………………………………………… 221367

• Valve Terminal Bracket …………………………………….226572
*not illustrated

---|---

Accessories

Antique Brick Panel Kit ……………………………………….155648
Variable Speed Blower …………………………………….. 156000
Fuel Conversion Kit to Propane ……………………………155372
Fuel Conversion Kit to Natural Gas ……………………..155373
Universal Leg Leveler Kit …………………………………….156096
Spark Screen ………………………………………………………. 157448
Wall Thermostat ……………………………………………….. 750003
Remote Control …………………………………………………. 750002
Floor Bracket Kit………………………………………………….750304
Torx T20 screwdriver ………………………………………….. 110002
4 mm Allen wrench ……………………………………………. 129646
Snapstat ……………………………………………………………….220617
Jøtul Gas Product Warranty
This warranty policy applies to gas products identified by Jøtul, Scan, and Atra trade names, as set forth below.
A. LIMITED FIVE YEAR WARRANTY – Cast Iron, Steel Doors, Surround Components, Firebox:
Jøtul North America Inc. (JØTUL) warrants, to the original retail purchaser, that those components of the Jøtul, Scan, or Atra Gas Stove or Fireplace specified above will be free of defects in material and workmanship for a period of five (5) years from the date of purchase. This warranty is subject to the terms, exclusions and limitations set
forth in the following text.
B. LIMITED TWO YEAR WARRANTY – Burner, Burner Treatments, Firebox Panels:
JØTUL warrants, to the original retail purchaser, that those components of the Jøtul, Scan, or Atra Gas Stove or Fireplace specified above will be free of defects in material and workmanship for a period of two (2) years from the date of purchase. This warranty is subject to the terms, exclusions, and limitations set forth in the following text.
C. LIMITED TWO YEAR WARRANTY – Enamel Finish: JØTUL warrants, to the original retail purchaser, the enamel finish on cast iron components of the Jøtul Stove or Fireplace Insert specified above against peeling or fading for a period of two (2) years from the date of purchase. This warranty is subject to the terms, exclusions and
limitations set forth below.
D. LIMITED ONE YEAR WARRANTY – Gas & Electrical Components (controls, plumbing, valve, blower):
JØTUL warrants, to the original retail purchaser, that those components of the Jøtul, Scan, or Atra Gas Stove or Fireplace specified above will be free of defects in material and workmanship for a period of one (1) year from the date of purchase. This warranty is subject to the terms, exclusions, and limitations set forth in the following text.
JØTUL will repair or replace (including parts & labor), at its option, any of the above components determined by JØTUL to be covered by this warranty. You must, at your own expense, arrange to deliver or ship the component to an authorized Jøtul, Scan, or Atra dealer and arrange for pickup or delivery of the component after repairs have been made. If, upon inspection, JØTUL determines that the component is covered by this warranty, the repair or replacement will be made as set forth abovThis warranty is not transferable and is extended only to, and is solely fthe benefit of, the original retail purchaser of the Jøtul, Scan, or Atra Gas Stove or Fireplace. This paragraph sets forth the sole remedy available under this warranty in the event of any defect in the Jøtul, Scan, or Atra Gas Stove or Fireplace.
The warranty period for any replaced component will be the remaining unexpired portion of the warranty period for the original component. Please retain your dated sales receipt in your records as proof of purchase
EXCLUSIONS AND LIMITATIONS
NOTICE: This warranty is void if installation or service is performed by someone other than an authorized installer, service agency or gas supplier, or if installation is not in conformance with the installation and operating instructions contained in this owner’s manual or local and/ or national fire and building regulations. A listing of local authorized installers, service agencies and gas suppliers can be obtained from the National Fireplace Institute at http://www.nficertified.org/.
This warranty does not cover the following:

  1. Repair or replacement of parts that are subject to normal wear and tear during the warranty period or to parts that may require
    replacement in connection with normal maintenance. These parts include light bulbs, paint, gaskets, and glass (except to the extent such parts suffer damage from thermal stress).

  2. Damage due to incorrect installations not in conformance with the installation instructions contained in this owner’s manual or local and/or national fire and building regulations.

  3. Damage due to service performed by an installer, service agency or gas supplier, unless otherwise agreed to in writing by JØTUL.

  4. Labor or other costs associated with the repair of gas controls, plumbing, burners, log set, or sheet metal firebox beyond the warranty period.

  5. Damage caused by unauthorized modification, use or repair.

  6. Damage to enameled surfaces caused by improper operation or misuse, including use that is not in conformance with the operating instructions contained in this owner’s manual. Such damage can typically be identified by bubbling, cracking, or discoloration of the enamel finish.

  7. Costs incurred by travel time and/or loss of service.

  8. Damage incurred while the Jøtul, Scan, or Atra Gas Stove or Fireplace is in transit.

IN NO EVENT SHALL JØTUL, ITS PARENT COMPANY, SHAREHOLDERS, AFFILIATES, OFFICERS, EMPLOYEES, AGENTS OR REPRESENTATIVES BE LIABLE OR RESPONSIBLE TO YOU FOR ANY SPECIAL, INDIRECT, INCIDENTAL, CONSEQUENTIAL, PUNITIVE OR OTHER SIMILAR DAMAGES, INCLUDING, BUT NOT LIMITED TO, LOST PROFITS, LOST SALES, INJURY TO PERSON OR PROPERTY, OR DAMAGES TO A STRUCTURE OR ITS CONTENTS, ARISING UNDER ANY THEORY OF LAW WHATSOEVER. ALL IMPLIED WARRANTIES, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, OR OTHERWISE, ARE LIMITED IN DURATION TO THE LENGTH OF THIS WRITTEN WARRANTY. EXCEPT AS EXPRESSLY SET FORTH HEREIN, JØTUL MAKES NO ORAL, WRITTEN OR OTHER WARRANTY WITH RESPECT TO JØTUL, SCAN OR ATRA GAS STOVES OR FIREPLACES.
Some states do not allow the exclusion or limitation of incidental or consequential damages, or limitations on the length of implied warranties. Therefore, the above exclusions or limitations may not apply to you. This warranty gives you specific legal rights, and you may have other rights, which vary from state to state.
JØTUL reserves the right to discontinue, modify or change the materials used to produce the Jøtul, Scan, or Atra Gas Stove or Fireplace. JØTUL shall have the right to replace any defective component with substitute components determined by JØTUL to be of substantially equal quality and price. The dollar value of JØTUL’s liability for breach of this warranty shall be limited exclusively to the cost of furnishing a replacement component. JØTUL shall not in any event be liable for the cost of labor expended
by others in connection with any defective component. Any costs or expenses beyond those expressly assumed by JØTUL under the terms of this warranty shall be the sole responsibility of the owner(s) of the Jøtul, Scan, or Atra Gas Stove or Fireplace.
No dealer, distributor, or other person is authorized to modify, augment, or extend this limited warranty on behalf of JØTUL. NO MODIFICATION OR CHANGE TO THIS WARRANTY WILL BE EFFECTIVE UNLESS IT IS MADE IN A WRITTEN DOCUMENT MANUALLY SIGNED BY AN AUTHORIZED OFFICER OF JØTUL.
An authorized installer may have been provided with certain information related particularly to the Jøtul, Scan, or Atra Gas Stove or Fireplace; however, no authorized installer or other person who may service the appliance is an agent of JØTUL. No inference should be made that JØTUL has tested, certified, or otherwise pronounced any person as qualified to install or service the appliance. JØTUL shall not be liable or otherwise responsible for any error or omission by a person installing or servicing a
Jøtul, Scan, or Atra Gas Stove or Fireplace. If you believe your Jøtul, Scan, or Atra Gas Stove or Fireplace is defective, you should contact your nearest authorized Jøtul, Scan, or Atra dealer,
who will process a warranty claim. IN ORDER TO QUALIFY FOR WARRANTY COVERAGE, JØTUL MUST RECEIVE NOTICE OF A POSSIBLE DEFECT WITHIN SIXTY (60) DAYS OF THE DATE THE DEFECT IS FIRST DISCOVERED, OR REASONABLY COULD HAVE BEEN DISCOVERED.
This warranty is given by Jøtul North America, Inc., 55 Hutcherson Drive, Gorham, Maine 04038 USA
LIGHTING INSTRUCTIONS
FOR YOUR SAFETY, READ BEFORE LIGHTING.
WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR LOSS OF LIFE.
A. This appliance has a pilot which must be lit by hand. When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING, smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle to the floor. WHAT TO DO IF YOU SMELL GAS:

  •  Extinguish any open flame.
  • Open windows.
  • Do not light any appliance.
  • Do not touch any electrical switches.
  • Do not use any phone in your building.
  • Immediately call your gas supplier from a neighbor’s phone.
  •  If your gas supplier cannot be reached, call the fire department. 

C. Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, do not try to repair it.
Call a qualified technician. Force or attempted repair may result in a fire or explosion.
D. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the
control system and any gas control which has been under water.

LIGHTING INSTRUCTIONS

  1. STOP! Read the safety information above.

  2. Access the lower controls.

  3. Turn the stove ON/OFF switch to “OFF”, or set the thermostat to lowest setting (if used).

  4. Confirm that the gas supply line shut-off valve is open.

  5. Push in gas control knob slightly and turn clockwise  to “OFF”.
    NOTE: Knob cannot be turned from “PILOT” to “OFF” unless the knob is pushed in slightly. Do not force.

  6. Wait five (5) minutes to clear out any gas. If you then smell gas, STOP! Follow “B” in the safety information above on this page. If you do not smell gas, go to the next step.

  7.  Push in gas control knob slightly and turn counterclockwise to “PILOT”.

  8. Push in control knob all the way and hold in.
    Immediately light the pilot by triggering the spark ignitor (push the red button repeatedly) until pilot lights. Continue to hold the control knob in for about one minute after the pilot lights. Release knob and it should spring back.
    The pilot should remain lit. If it goes out, repeat Steps 5 through 8. • If knob does not return when released, stop and immediately call your service technician or gas supplier.
    • If pilot will not stay lit after several tries, turn the control knob to OFF and call your service technician or gas supplier.

  9.  Turn gas control knob counterclockwise to “ON”.

  10. Turn the stove ON/OFF switch to “ON”, or set thermostat (if used) to desired temperature.

TO TURN OFF GAS TO THE APPLIANCE:

  1. Turn ON/OFF switch to” OFF”. The pilot will remain lit for normal service.
  2.  For complete shutdown, turn ON/OFF switch to “OFF”.
  3. Access the lower controls.
  4. Depress gas control knob slightly and turn clockwise to OFF”. Do not force.

January 2022
139957-Rev 28

This appliance must be installed in conformance with local and national building regulations. Before beginning the installation, it is important that these instructions be carefully read and understood. Jøtul maintains a policy of continual product development. Consequently, products may differ in specification, color or type of accessories from those illustrated or described in various publications.