Jotul F 35 Rockwood Wood Stoves Instruction Manual
- September 18, 2024
- Jotul
Table of Contents
F 35 Rockwood Wood Stoves
Specifications
This wood heater meets the 2020 U.S. Environmental Protection
Agency’s emission limits for wood heaters manufactured after May
15, 2020.
Product Usage Instructions
1. Installation
1.1 Unpack the Stove
Follow the instructions provided in section 1.1 to unpack the
stove properly.
1.2 Top Exit Flue Adaptor Orientation
Refer to section 1.2 for guidance on the correct orientation of
the top exit flue adaptor.
1.3 Short Leg Installation
For installing short legs, follow the steps outlined in section
1.3.
1.4 Floor Bracket Installation
Install the floor brackets as per the instructions in section
1.4 to secure the stove properly.
1.5 Rear Exit Flue Collar Orientation
Section 1.5 provides information on the orientation of the rear
exit flue collar.
1.6 Chimney Connector
Follow the guidelines in section 1.6 for connecting the chimney
correctly.
2. Chimney Requirements
Refer to sections 2.1 to 2.4 for detailed information on chimney
requirements based on different types of chimneys.
3. Chimney Connection
Depending on the type of chimney, follow the instructions in
sections 3.1 to 3.4 for proper chimney connection.
7. Optional Accessories
Instructions for installing optional accessories like short
legs, outside air kit, and mobile home floor bracket can be found
in section 7.
8. Appendix
Refer to section 8.1 for information on start-up and refueling
procedures.
FAQ
Q: What is included in the Mobile Home Floor Bracket Kit?
A: The kit includes two brackets used to secure the stove
directly to the floor as required for mobile home
installations.
Q: What does the Outside Air Kit include?
A: The kit includes an adaptor collar that allows connection
between an exterior wall air inlet through a duct directly to the
bottom of the stove fuel bed.
Jøtul F 35 Rockwood Wood Burning Stove
Jøtul F 35 Rockwood
Installation and Operating Instructions
The Jøtul F 35 heater is listed to burn solid wood only. Do not burn any other
fuels.
Read this entire manual before you install and use this appliance.
Save these instructions for future reference and make them available to anyone
using or servicing the fireplace insert.
This wood heater requires periodic inspection and repair for proper operation.
See this manual for specific maintenance information. It is against federal
regulations to operate this wood heater in a manner inconsistent with the
operating instructions in this owner’s manual.
This heater meets the 2020 U.S. Environmental Protection Agency’s
emission limits for wood heaters manufactured after May 15, 2020.
Une version française de ce manuel est disponible au téléchargement sur
www.jotul.ca
Jøtul F 35 130074_2 7/24
Table of Contents
Accessories …………………………………………………………… 2
Standards / Codes ………………………………………………… 3
Combustion Specifications …………………………………… 3
Safety Notices ……………………………………………………………..4
1.0 Installation 1.1. Unpack the Stove ……………………………………………………5 1.2 Top Exit Flue
Adaptor Orientation …………………………5 1.3 Short Leg Installation
……………………………………………..5 1.4 Floor Bracket Installation ………………………………………..5 1.5
Rear Exit Flue Collar Orientation…………………………….6 1.6 Chimney Connector
……………………………………………….6
2.0 Chimney Requirements 2.1 Masonry Chimneys ………………………………………………..7 2.2
Prefabricated Chimneys ………………………………………….7 2.3 Chimney
Height……………………………………………………..8 2.4 Wall Pass-Throughs …………………………………………………8
3.0 Chimney Connection 3.1 Masonry Chimneys ………………………………………………..9 3.2
Hearthmount into a Masonry Fireplace……………………9 3.3 Prefabricated Chimneys
………………………………………….10 3.4 Mobile Home Requirements …………………………………..10
4.0 Clearances to Combustibles 4.1 Floor Protection ……………………………………………………..11
4.2 Clearances to Walls and Ceilings ……………………………..11 4.3 Using Shields to
Reduce Clearances ………………………..11 4.4 Alcove Installation…………………………………………………..13
4.5 Fireplace Clearances, Mantel and Trim ……………………… 13 4.6 Clearance Diagrams
………………………………………………..14 4.7 Double Wall Connector Manufacturers……………………15
5.0 Operation 5.1 Combustion Efficiency ……………………………………………16 5.2 CO Emissions
………………………………………………………..16 5.3 Wood Fuel and Performance……………………………………16 5.4 F
35 Functionality…………………………………………………..17 5.5 Air Control / Blower
Settings…………………………………..17 5.6 Controlling the Fire ………………………………………………..17 5.7
Break-in Procedure …………………………………………………18 5.8 Starting and Maintaining a Fire
………………………………18 5.9 Adding Fuel ……………………………………………………………19 5.10 Creosote and the
Need for Removal ……………………….19 5.11 Ash Removal …………………………………………………………..19
6.0 Maintenance 6.1 Door Latch ……………………………………………………………..20 6.2 Glass Care
………………………………………………………………20 6.3 General Care…………………………………………………………..20 6.4
Gasket Replacement……………………………………………….21 6.5 Glass
Replacement………………………………………………….21 6.6 Chimney System ……………………………………………………22
6.7 Firebricks ……………………………………………………………….22 6.8 Secondary Manifold Maintenance
…………………………..22
7.0 Optional Accessories 7.1 Short Leg Installation ……………………………………………..23 7.2
Outside Air Kit ……………………………………………………..23 7.3 Mobile Home Floor Bracket
…………………………………..23
8.0 Appendix 8.1 Start-Up and Refueling …………………………………………..24
9.0 Illustrated Part List …………………………………………………… 26
10.0 Warranty Statement ………………………………………………31
Jøtul F 35 Rockwood Accessories
Stove-Top Thermometer – #5002 We recommend the use of a magnetic stove-top
thermometer to monitor the surface temperature of the stove. The optimum
surface temperature range for the most efficient performance is between 4000 F
– 7000 F (2050 C – 3160 C). Short Leg Kit – #157636 This kit includes four, 4
1/4″ steel legs which allow stove installation into a fireplace opening height
as low as 25 1/2″. Approved only for code-approved, masonry fireplace hearth
mount installation. Not approved for use in mobile homes. See page 23.
Mobile Home Floor Bracket Kit – #157321 This kit includes two brackets used to
fulfill the mobile home requirement that the stove be secured directly to the
floor. See installation instructions on page 23.
Outside Air Kit – #158265 This kit includes an adaptor collar that allows
connection between an exterior wall air inlet through a duct directly to the
bottom of the stove fuel bed. See installation instructions on page 23.
2
Jøtul F 35 130074_2 7/24
Standards
The Jøtul F 35 Rockwood non-catalytic heater has been tested and listed to:
U.S.: ANSI/UL 1482 Canada: CAN/ULC-S627
Certified Safety Tests performed by: ITS, Intertek Testing Services Middleton,
WI
Manufactured by: Jøtul North America 55 Hutcherson Drive Gorham, Maine
04038-2644
Check Building Codes
When installing, operating and maintaining your Jøtul F 35 Rockwood woodstove,
follow the guidelines presented in these instructions, and make them available
to anyone using or servicing the stove.
Your city, town, county or province may require a building permit to install a
solid fuel burning appliance.
In the U.S., the National Fire Protection Association’s Code, NFPA 211,
Standards for Chimneys, Fireplaces, Vents and Solid Fuel Burning Appliances,
or similar regulations, may apply to the installation of a solid fuel burning
appliance in your area.
In Canada, the guideline is established by the CSA Standard, CAN/CSA-B365-M93,
Installation Code for Solid-Fuel-Burning Appliances and Equipment.
Always consult your local building inspector or authority having jurisdiction
to determine what regulations apply in your area.
The Jøtul F 35 Rockwood is approved for use in mobile homes. Install in
accordance with 24 CFR, Part 3280 (HUD). Follow the instructions in this
manual.
! WARNING !
THIS WOOD HEATER HAS A MANUFACTURER-SET MINIMUM LOW BURN RATE THAT MUST NOT BE
ALTERED. IT IS AGAINST FEDERAL REGULATIONS TO ALTER THIS SETTING OR OTHERWISE
OPERATE THIS WOOD HEATER IN A MANNER INCONSISTENT WITH OPERATING INSTRUCTIONS
IN THIS MANUAL.
Combustion Specifications
Heat Output Range:1 Heating Capacity:2
13,533 to 59,443 BTU/hr. Up to 1,200 sq. ft.
Maximum Burn Time: EPA Efficiency:3 CO Emissions:4 Particulate Emissions:5
Up to 6 3/4 hours HHV: 68.5% LHV: 73.67% 1.35 g/min 1.2 g/hr – Cord Wood
Fuel: 16″ Logs (40 cm) Front to Back
See the Operation section of this manual for important information regarding the safe, proper, and most efficient operation of your stove.
1. Heat Output Range results are determined during specific emissions tests
established by the EPA.
2. Heating Capacity will vary depending on design of home, climate, wood type
and operation.
3. EPA Validated Efficiency: High Heat Value (HHV) and Low Heat Value (LHV)
efficiencies are determined per the CSA B415.1-10 test method. The difference
between the HHV and LHV is in how the energy in the exhaust gas water vapor is
accounted.
LHV efficiency assumes all the water vapor in combustion gas was condensed and
the heat from such was recovered and transferred to the dwelling. HHV
calculations do not assume all water vapor is condensed, therefore the HHV
value is less than the LHV value.
4. Carbon Monoxide Emissions rate results from Test Method CSA B415.1-10.
5. Particulate Emissions rate is obtained using EPA Test Methods: ALT-125
(Cordwood Fuel) ASTM E2515 ASTM E3053
3
Jøtul F 35 130074_2 7/24
Safety Notices
· BURN SOLID, NATURAL WOOD FUEL ONLY. DO NOT BURN ANY OTHER FUEL.
· DO NOT USE CHEMICALS OR FLUIDS TO START A FIRE. DO NOT BURN GARBAGE OR
FLAMMABLE FUELS.
· DO NOT USE A GRATE OR ELEVATE THE FIRE. BUILD THE FIRE DIRECTLY ON THE
HEARTH.
· IF THIS ROOM HEATER IS NOT PROPERLY INSTALLED, A HOUSE FIRE MAY RESULT. TO
REDUCE THE RISK OF FIRE, FOLLOW THE INSTRUCTIONS IN THIS MANUAL. FAILURE TO
FOLLOW THESE INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE, BODILY INJURY, OR
LOSS OF LIFE.
· CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION
INSPECTION REQUIREMENTS IN YOUR AREA.
· ANY EXISTING CHIMNEY SYSTEM MUST BE INSPECTED BEFORE INSTALLATION OF THIS
APPLIANCE.
· DO NOT CONNECT THIS STOVE TO ANY AIR DISTRIBUTION DUCT OR SYSTEM.
· EXTREMELY HOT WHILE IN OPERATION! KEEP CHILDREN, CLOTHING, AND FURNITURE
AWAY. CONTACT WILL CAUSE SKIN BURNS. USE A CHILD GUARD SCREEN TO PREVENT
ACCIDENTAL CONTACT BY SMALL CHILDREN.
· INSTALL SMOKE DETECTORS IN THE LIVING AREA AND BEDROOMS OF YOUR HOME. TEST
THEM REGULARLY AND INSTALL FRESH BATTERIES TWICE ANNUALLY.
WHEN INSTALLED IN THE SAME ROOM AS THE STOVE, A SMOKE OR CARBON MONOXIDE
DETECTOR SHOULD BE LOCATED AS FAR FROM THE STOVE AS POSSIBLE TO PREVENT THE
ALARM SOUNDING WHEN ADDING FUEL.
· Avoid creating a low pressure condition in the room where the stove is
operating. Be aware that operation of an exhaust fan or clothes dryer can
create a low pressure area and consequently promote flow reversal through the
stove and chimney system. In some cases, the optional Outside Air Kit #157637
can be used to alleviate this condition. The chimney and building, however,
always work together as a system – provision of outside air, directly or
indirectly to an atmospherically vented appliance will not guarantee proper
chimney performance. Consult your local Jøtul authorized dealer regarding
specific installation/performance issues.
· Jøtul strongly recommends that this stove be installed by a professional
solid fuel technician, or that you consult one if you do the work yourself.
Also, consult your insurance company regarding any other specific
requirements.
1.0 Installation
If this solid fuel room heater is not properly installed, a house fire may
result. For your safety, follow the installation directions. Contact the local
building or fire officials about restrictions and installation inspection
requirements in your area.
Your local officials have final authority in determining if a proposed
installation is acceptable. Any requirement by the local authority having
jurisdiction that is not specifically addressed in this manual, defaults to
NFPA 211, and local codes in the U.S. or in Canada, CAN/ CSA-B365-M and local
codes.
Recommended Installation Tools
· Measuring Tape
· Phillips screwdriver · 10 mm open-end
or socket wrench
· Work Gloves
· Safety Glasses · 4 mm hex key · 13 mm open-end or
socket wrench
PLEASE NOTE:
IT IS NORMAL FOR SMOKE AND ODOR TO OCCUR DURING THE INITIAL STAGES OF
OPERATION, DEPENDING UPON TEMPERATURES GENERATED OVER TIME. THIS “CURING”
CONDITION CAN BE ALLEVIATED BY PROMOTING FRESH AIR CIRCULATION WITHIN THE
IMMEDIATE VICINITY OF THE APPLIANCE.
4
1.1 Unpack the Stove
Inspect the stove for damage. Contact your dealer immediately if any damage is
found. Do not install the stove if any damage is evident.
Contents: · Miscellaneous Hardware
· Single-wall 45° adaptor
· Double-wall Starter Collar P/N 227144
NOTE: The integral Rear Shroud acts as a heat shield. There is no accessory
stove heat shield.
DO NOT REMOVE THE REAR HEAT SHIELD
1.2 Short Leg Kit 157636 Installation
This set of four steel legs reduces stove height by 3 1/4 inches allowing
installation into fireplaces having a low lintel. See fig. 22, page 21.
Approved for use only in a code-approved, masonry fireplace.
1.3 Floor Bracket Kit 157321
Install this kit to conform to Mobile Home code woodstove installation
requirements. See fig. 24, page 21.
1.4 Flue Outlet Orientation
The cast iron flue collar is oriented to exit at 45°. A 45° singlewall sheet
metal adapter is provided. This adapter can be used to change the orientation
to rear exit or top exit on single-wall installations only. If using a double-
wall pipe use the included double-wall starter collar and a 45° double-wall
elbow (not included). See pages 15 for common adapter manufacturers and
double-wall pipe clearances.
Jøtul F 35 130074_2 7/24
NOTE: The single-wall 45 ° adaptor that is provided with the stove must be
used to maintain the listed clearances in the manual. CONNECTING DOUBLE WALL
PIPE TO A SINGLE WALL ADAPTOR WILL VIOLATE SAFETY COMPLIANCE. Single Wall Pipe
Installation: Secure the provided 45° adaptor to
the cast flue collar holes with the two screws provided. Double Wall Pipe
Installation: Secure the Double Wall Starter
Collar to the cast flue collar holes with the two screws provided. Then,
attach the 45° double wall elbow (not provided) to the Double Wall Starter
Collar with three sheet metal screws. (not provided) Please refer to page 15.
Table A in the manual for the correct clearance that corresponds to the pipe
manufacturer used and the stove position of your installation
9 1/2″ 6″ dia.
23 5/8″ 22 1/2″
22 1/2″ 30 1/4″ 45° Rear/Top Exit Flue Collar Adaptor
WINDOW AREA 96 sq. in.
26 1/2″
TO STOVE FLUE COLLAR
28 3/4″ 25 3/4″
20 1/4″ Figure 1. F 35 dimensional views.
18″ Use Short Leg Kit #157636 to reduce stove height by 3 1/4″. Hearthmount
installation only.
5
Jøtul F 35 130074_2 7/24
1.6 Chimney Connector
Use 6″ single wall or listed 6″ double-wall stovepipe to connect the stove to
the chimney. Single wall stovepipe must be black steel or stainless steel and
have a minimum thickness of 24 gauge. Do not use aluminum or galvanized steel
pipe for chimney connection – these materials are not suitable for use with
solid fuel. Attach the flue collar to the chimney connection using 2 self-
drilling screws found in the miscellaneous kit.
Follow these guidelines:
· Do not use chimney connector as a chimney. It is intended only as a
connection device to a code approved chimney.
· Each connector section must be oriented with the male (crimped) end pointing
toward the stove. See fig. 3.
· Secure all connector joints with three sheet metal screws.
· For the best performance, the chimney connector should be as short and
direct as possible, including no more than two 90° elbows.
· The maximum vertical run of single wall stovepipe should not exceed 10 ft.
· The maximum horizontal run should not exceed 3 ft. with a 1/4″ rise per
foot. Under no circumstance should horizontal pipe be installed slanting down
toward the chimney.
· No part of the chimney connector may pass through an attic or roof space,
closet or other concealed space, or through a floor or ceiling. All sections
of the chimney connectors must be accessible for cleaning.
· Where passage through a wall or partition of combustible construction is
desired, the installation must conform with NFPA 211 or CAN/CSA-B365, and is
also addressed in this manual.
· Do not connect this stove to a chimney flue serving another appliance.
Toward Stove
Flue Gas Direction
Figure 3. Chimney connector orientation.
6
2.0 Chimney Requirements
There are two types of approved chimneys:
1. A code-approved masonry chimney with a ceramic tile or listed steel flue
liner.
2. A prefabricated chimney complying with the requirements for Type HT
(2100°F) chimneys per UL 103 or ULC S629.
An NFPA 211 Level 1 chimney inspection should be performed prior to
installation. Depending on specific circumstances and the outcome of the Level
1 inspection it may be determined that a Level 2 or 3 inspection is also
necessary.
The chimney size should not be less than the cross-sectional area of the flue
collar, and not more than three times greater than the cross-sectional area of
the flue collar. If the chimney flue is outdoors, its cross-sectional area may
not exceed two times greater than the stove flue collar. See also Sect. 3.2.
When selecting a chimney type and the location for the chimney in the house,
keep this in mind: It is the chimney that makes the stove work – not the stove
that makes the chimney work. This is because a chimney actually creates a
suction, called “draft” which pulls air through the stove.
Several factors affect draft: chimney height, cross-sectional area (size), and
temperature of the chimney, as well as the proximity of surrounding trees or
buildings.
A short exterior masonry chimney will give the poorest performance because it
will be difficult to warm the flue and sustain the temperatures necessary to
maintain draft strength. In extremely cold climates, it may be necessary to
reline the chimney or extend the height to help establish draft.
A tall, interior masonry chimney is easier to keep warm and will perform well
under a variety of weather and environmental conditions.
The following guidelines give the necessary chimney requirements based on the
national code (ANSI-NFPA 211 for the US. And CSA CAN-B365 for Canada).
However, many local codes differ from the national code to take into account
climate, altitude, or other factors. Your local building inspector is the
final approving authority. Consult them prior to installation.
Do not connect the stove to any air distribution duct or system.
2.1 Masonry Chimneys
Follow these guidelines when installing the Jøtul F 35 into a masonry chimney:
· The masonry chimney must have a fireclay liner or equivalent, with a minimum
thickness of 5/8″ (14 mm) and must be installed with refractory mortar. There
must be at least 1/2″air space between the flue liner and chimney wall.
· The fireclay flue liner must have a nominal size of 8″ X 8″, and should not
be larger than 8″X 12″. A round fireclay liner must have a minimum inside
diameter of 6″ and maximum inside diameter of 8″.
Jøtul F 35 130074_2 7/24
A larger chimney should be relined with an appropriate code approved liner.
· Brick or modular block must be a minimum of 4″ nominal thickness. Stone
construction must be at least 12″ thick.
· A newly-built chimney must conform to local codes, or, in their absence,
must comply with national regulations.
· An existing chimney must be subjected to a Level I inspection by a
professional, licensed chimney sweep, fire official, or code officer to ensure
that the chimney is in proper working order. Any repairs must be completed
before installing the stove.
· A Level II inspection is indicated when verification of the suitability of
the chimney for new or changed conditions of service is needed, or when a
Level I inspection is not sufficient to determine the serviceability of the
chimney is needed.
· No other appliance may be vented into the same flue.
· An airtight clean-out door should be located at the base of the chimney.
2.2 Prefabricated Chimneys
A prefabricated metal chimney must be tested and listed for use with solid
fuel burning appliances. High Temperature (HT) Chimney Standard UL 103 for the
U.S. and High Temperature Standard ULC S-629 for Canada.
The manufacturer’s installation instructions must be followed precisely.
Always maintain the proper clearance to combustibles as established by the
pipe manufacturer. This clearance is usually a minimum of 2″, although it may
vary by manufacturer or for certain chimney components.
Figure 4. Chimney Height Requirement.
Header
2″ clearance between wall stud and chimney
Flue Liner
12″
Pass-through construction: 12″ brick from thimble to chimney
12″
Thimble: 5/8″ Fireclay Liner or equivalent
Sill/Support
2.3 Chimney Height
The chimney must be at least 3 feet higher than the highest point where it
passes through the roof and at least 2 feet higher than the highest part of
the roof or structure that is within 10 feet of the chimney, measured
horizontally. See fig. 4.
Chimneys shorter than 14 feet may not provide adequate draft. Inadequate draft
can result in smoke spillage when loading the stove, or when the door is open.
Poor draft can also cause back puffing (ignition of gas build-up inside the
firebox) and sluggish performance. The minimum height does not, in itself,
guarantee proper chimney performance. Optimum draft force should be in the .05
– .10 in. w.c. range measured by a Magnahelic gauge. Draft at .07 w.c. is
ideal.
Excessive chimney height can promote over-strong draft resulting in high stove
temperatures and short burn times. Your Jøtul dealer is an expert resource to
consult regarding draft issues or other performance-related questions.
2.4 Wall Pass-Throughs
Note: In addition to the methods described here, any listed, prefabricated
wall pass-through components available from chimney manufacturers may be used.
Figure 5. Masonry Wall Pass-through.
In the U.S.
The National Fire Protection Association’s publication, NFPA 211, Standard for
Chimneys, Fireplaces, Vents and Solid Fuel Burning Appliances permits four
methods for passing through a combustible wall. Before proceeding with any
method be sure to consult with your local building officials to discuss any
local code requirements.
Common Method:
See fig. 5. Remove all combustible materials from the passthrough area (
around the chimney connector), a minimum 12″. A 6″ diameter connector will
require a 31″ x 31″ square opening.
The opening must be filled with at least 12″ of brick around a fireclay liner.
The liner must be ASTM C35 or equivalent, having a minimum wall thickness of
5/8″.
The Pass-through must be at least 18″ from combustible ceiling materials.
7
Jøtul F 35 130074_2 7/24
It will be necessary to cut wall studs, install headers, and construct a sill
frame to maintain the proper dimensions and to support the weight of the
brick.
The bricks must be solid brick with a minimum of 3 inches thick (nominal 4″).
Refractory mortar must be used at the junction of the chimney and the pass-
through liner. The pass-through liner must not penetrate the chimney liner
beyond the inner surface of the chimney liner. Use extreme care when
constructing the hole in the chimney liner as the tiles can shatter easily.
In Canada
The installation must conform to CAN/CSA-B365, Installation Code for Solid
Fuel Burning Appliances and Equipment. Before proceeding be sure to consult
your local building inspector.
Common Method:
This method requires the removal of all combustible materials from at least
18″ around the chimney connector’s proposed location. A 6″ round liner
requires a minimum opening 43″ x 43″ square.
Locate the pass-through at least 18″ from combustible ceiling materials.
The space that is cleared of combustible materials must remain empty. Sheet
metal panels can be used to cover the area. However, when using a panel on
both sides of the wall, each cover must be installed on noncombustible spacers
at least 1″ from the wall. If one panel of sheet metal is to be used it may be
installed flush to the wall.
See section 5.3.1 and 5.3.2 of CAN/CSA – B365-M91. Consult your local building
inspector, authorized Jøtul Dealer, NFPA 211 in the U.S. or CAN/CSA-B635 in
Canada for other approved wall pass-through methods.
Connector pipe must be flush with the inside of the flue tile
Chimney Connector
Thimble Figure 6. Masonry Chimney Thimble.
Flue Tile
Connector extends at least into the first flue. Direct connection to the
chimney cap is highly recommended.
Damper is sealed with a steel plate and high-temperature sealant.
Figure 7. Hearthmount Installation.
8
Jøtul F 35 130074_2 7/24
3.0 Connecting to the Chimney
3.1 Masonry Chimney
A ceramic or steel thimble is commonly used to penetrate the chimney wall into
the flue. The chimney connector/stove pipe must slide completely inside
thimble to the inner surface or the flue liner. It may be necessary to include
a thimble sleeve having a slightly larger diameter than the connector pipe.
See fig. 6.
The connector pipe and/or thimble sleeve must not protrude into the flue liner
or otherwise restrict draft.
Use refractory cement to seal the seams between the chimney connector, sleeve,
and thimble.
Do not connect this stove to a chimney flue servicing another appliance of any
kind.
3.3 Prefabricated Chimneys
When connecting the Jøtul F 35 to a prefabricated metal chimney always follow
the pipe manufacturer’s instructions and be sure to use the all components
that are required. This usually includes a chimney adaptor that is secured to
the bottom section of the metal chimney and allows the chimney pipe to be
secured to it with two sheet metal screws. See fig. 8.
3.2 Hearthmount into a Masonry Fireplace
The Jøtul F 35 on standard legs may be installed into a masonry fireplace with
a minimum opening height of 27″.
Use Short Leg Kit 157636 to install into a fireplace with a minimum opening
height of 23 1/8″. Short legs are approved only for use on a code-approved,
masonry fireplace and hearth.
Building code requires that the fireplace damper plate be removed or securely
fixed in the open position. A connector pipe must then extend from the stove’s
flue exit through the damper area of the fireplace and into the chimney tile
liner. See fig. 7. In any case, we recommend that a full liner be installed
through any masonry chimney to ensure good performance.
The cross-sectional area of the flue of a chimney with no walls exposed to the
outside below the roof line may be no more than three times the cross-
sectional area of the stove flue collar.
The cross-sectional area of the flue of a chimney with one or more walls
exposed to the outside below the roof line may be no more than two times the
cross-sectional area of the stove flue collar.
If the chimney liner is too large to accommodate the stove, an approved
relining system must be installed to resize the flue.
A new sheet metal damper block-off plate must be installed around the
connector pipe at the damper frame and sealed with the proper sealant (usually
High-Temp Silicone).
Listed Chimney
Storm Collar
Flashing Specified clearance
Attic Insulation Shield
Ceiling Support
Chimney Adaptor
Chimney Connector
Figure 8. Prefabricated Listed Type HT Chimney.
9
Jøtul F 35 130074_2 7/24
3.4 Mobile Home Installation
The Jøtul F 35 is approved for installation in manufactured mobile homes
provided the following requirements are met:
1. All chimney components, including chimney sections, supports, spark
arrestor, etc., shall comply with the Standard for Factorybuilt Chimneys for
Residential Type and Building Heating Appliances, UL 103 and/or CAN/ULC-S629
Standard for 650°C Factory-built Chimneys.
2. The chimney shall be attached directly to the stove and extend at least 3
ft. above the roof. Termination must be at least 2 ft. above the highest
elevation of any part of the mobile home within 10 ft. Close clearance pipe
must be used.
3. All heat shields must remain on the stove.
4. In order to allow for transportation of the mobile home, the chimney
termination shall be readily removed at or below an elevation of 13.5 ft.
above ground level and reinstalled without use of special tools or
instructions.
5. A spark arrester must be installed at the termination. The net free area
of the arrester above the chimney outlet must not be less than four times the
net area of the chimney outlet, and the vertical height of the arrester must
not be less than one-half the diameter of the chimney flue. Openings shall not
permit the passage of a sphere having a diameter larger than 1/2″, and shall
permit the passage of a sphere having a diameter of 3/8″.
6. Direct connection of the stove to an outside air source is required. Use
Outside Air Kit #158265 . Do not substitute any other connection method or
device. See Appendix, Section 7.0. Duct termination must not be installed at a
level that is higher than the air inlet located at the bottom of the stove.
7. The stove must be secured to the mobile home floor. Use Floor Bracket Kit
157321.
8. When the chimney exits the mobile home at a location other than through
the roof, and exits at a point 7 ft. or less above the ground level, a guard
or other method of enclosing the chimney, must be provided at the point of
exit for a height up to 7 ft. Openings of this chimney guard shall not permit
penetration of a 3/4 in. diameter rod, or contact with the chimney by a 1/2
inch diameter rod inserted through the opening a distance of 4 inches.
9. Provision must be made for electrical grounding of the chimney, chimney
connector, and stove in accordance with local building codes.
WARNING: Do not install this appliance in a sleeping room.
CAUTION: The structural integrity of the mobile home floor, walls, and
ceiling/roof must be maintained.
10
4.0 Clearance to Combustibles
4.1 Floor Protection
The Bottom Heat Shield must remain on the stove unless the stove is installed
on concrete poured on earth.
The Jøtul F 35 also requires one of the following forms of hearth protection
if not installed directly on concrete poured on earth:
Any continuous non-combustible material or properly sized UL/ ULC Type I or
Type II hearth pad
All floor protection materials must be non-combustible (i.e., metals, brick,
stone, mineral fiber boards, etc.). Any organic materials (i.e., plastics,
wood, paper products, etc.) are combustible and must not be used.
IN THE U.S.: Floor protection must extend continuously forward from the door
opening at least 16 in. and 8 in. from the sides of the door opening.
Protection must also extend 2 in. from the rear and 2″ to the sides under any
horizontal or vertical chimney connector. This will result in a minimum floor
protector measuring 30″ wide x 40.5″ deep for rear exit and 30″ wide x 43.25″
deep for top exit. See figs 9 and 9a.
IN CANADA: Floor protection must extend continuously 18″ from the front of the
stove and 8 in. from the sides and rear. It must also extend 2 in. under any
horizontal chimney connector. This results in a floor protector dimension of
39″ wide x 48.5″ deep for rear exit and 39″ wide x 47.75″ deep for top exit.
See figs.10 and 10a.
Jøtul F 35 130074_2 7/24
4.2 Clearances to Walls and Ceilings
The clearances listed and diagramed in this manual have been tested to UL and
ULC standards and are the minimum clearances to combustible materials
specifically established for the Jøtul F 35.
A combustible surface is anything that can burn (i.e. sheet rock, wall paper,
wood, fabrics etc.). These surfaces are not limited to those that are visible
and also include materials that are behind non-combustible materials. If you
are not sure of the combustible nature of a material, consult your local fire
officials.
Remember: “Fire Resistant” materials are considered combustible; they are
difficult to ignite, but will burn. Also “Fire-rated” sheet rock is also
considered combustible.
Contact your local building officials about restrictions and installation
requirements in your area. See pages 12-15 for clearance requirements and
diagrams.
4.3 Using Shields to Reduce Clearances
Double Wall Connector: Listed double wall pipe is an acceptable alternative to
connector pipe heat shields.
Wall-Mounted Protection: When reducing clearances through the use of wall-
mounted protection:
In the U.S. refer to NFPA 211, Standard for Chimneys, Fireplaces, Vents and
Solid Fuel Burning Appliances, for acceptable materials, proper sizing and
construction guidelines.
In Canada, refer to CAN/CSA-B365, Installation Code for SolidFuel Burning
Appliances and Equipment, also for acceptable materials, proper sizing and
construction guidelines.
Notice: Many manufacturers have developed woodstove accessories that permit
clearance reduction. Use only those accessories that have been tested by an
independent laboratory and carry the laboratory’s testing mark. Be sure to
follow all of the manufacturer’s instructions.
11
Jøtul F 35 130074_2 7/24
2″
2″
2″
40.5″
43.25″
DOOR
16″
OPENING
8″
8″
30″
Figure 9. Floor Protection minimum dimensions, U.S. Rear Exit.
DOOR
16″
OPENING
8″
8″
30″
Figure 9a. Floor Protection minimum dimensions, U.S. Top Exit.
2″
8″
8″
48.5″
47.75″
18″ 18″
8″ 39″
Figure 10. Floor Protection minimum dimensions, CAN. Rear Exit .
8″ 39″
Figure 10a. Floor Protection minimum dimensions, CAN. Top Exit.
12
4.4 Alcove Installation
The Jøtul F 35 can be installed in an alcove as diagrammed in figs. 11.-12. 1.
Only double-wall chimney connector may be used. 2. Wall and ceiling
protection, if used, must extend over the entire
area. 3. Alcove floor protection must consist of a continuous non-
combustible material. 4. Minimum Alcove Ceiling Height from Floor:
Unprotected Surface – 72″ Protected Surface – 65″
The Short Leg option is not approved for use in Alcove installations.
4.5 Clearances to Fireplace Mantels and Surrounding Trim
See fig. 13 and the Clearance Chart on page 14 for approved clearances to
combustible materials that may be part of fireplace construction. Mantel and
Trim clearances may be reduced by 50%, up to a minimum of 18″, with use of
shielding constructed in accordance with NFPA 211 specifications.
Jøtul F 35 130074_2 7/24
7″ 48″
6″
6″
34.5″
Figure 12. Alcove with Wall Protection.
20 in.
46 in.
17″
16 in.
8 in.
Figure 13. Mantel and Trim Clearances
48″
Note: Short Legs reduce stove height by 3 1/4″
14″
14″
50.5″
Figure 11. Alcove Clearances.
13
Jøtul F 35 130074_2 7/24
4.6 Jøtul F 35 Clearance Specifications
UNPROTECTED WALLS
PROTECTED WALLS PER NFPA211 OR CAN/CSA-B365-M93
SIDE
REAR
CORNER TO
CORNER FRONT FLOOR
PROTECTION**
FRONT FLOOR PROTECTION WIDTH**
SIDE
REAR
CORNER TO
CORNER FRONT FLOOR
PROTECTION**
FRONT FLOOR PROTECTION WIDTH**
A
B
C
D
E
F
Single Wall Connector 13″
14″
10″
US: 61 1/4″
CAN: 63 1/4″
US: 30″ CAN: 39″
4″
A
Double Wall Connector
13″
K *
C
L
E
US: 30″
9″*
US: 59 7/8″ CAN 61 7/8″
CAN: 39″
F 4″
G
H
I
J
6″
4″
US: 53″ CAN: 55″
US: 30″ CAN: 39″
N
M
I
J
4″*
US: 53″ CAN: 55″
US: 30″ CAN: 39″
- See Table A, Pg. 15 for installation specifics.
** US and CAN measurements are not the same and are not interchangeable.
NOTE: Drawings not to scale
US: 45 1/2 ” / CAN: 49 1/2”
US: 45 1/2 ” / CAN: 49 1/2”
UNPROTECTED WALLS
24 1/8”
14”
13 3/4” B
Flue Center
14” C
Single Wall Connector
US: 33 1/2″ CAN: 28″
A
HEARTH EXT
D E
C
US: 33 1/2” CAN: 28”
Double Wall Connector
24 1/8”
K
- Flue Center
A
HEARTH EXT
Figure 14.
US: 32″ CAN: 27″
- *C
D E
C
US: 32” CAN: 27”
US: 50 1/2” / CAN: 54 1/2 ”
US: 51” / CAN: 57 1/2”
PROTECTED WALLS
PER NFPA 211 OR CAN/CSA-B365-m93
15 1/2”
8″
G
5 1/4”
Flue Center
8” H
F
HEARTH EXT
I J
H
US: 24 1/2” CAN: 22”
N
-
- Flue Center
M
F
HEARTH EXT
I J
M
US: 24 1/2” CAN: 22”
Note: Double walled pipe requires the use of the double wall 45° adaptor. DO
NOT USE THE SUPPLIED SINGLE WALL 45° ADAPTOR. CONNECTING DOUBLE WALL PIPE TO A
SINGLE WALL ADAPTOR WILL VIOLATE SAFETY COMPLIANCE.
14
Jøtul F 35 130074_2 7/24
Table A
F 35 with Double Wall Chimney Connector Installation Specifications
K Standard Install without wall protection
Front Edge of Hearth Extension From Rear Wall
Brand
Backwall with DW Pipe at 6″
ICC Ventis Security Selkirk DuraVent
10 ” (257mm) 11 ” (302mm) 10 ” (276mm) 10 ” (264mm) 11 ” (289mm)
N Standard Install with wall protection
Centerline from backwall
9 ” (232mm) 9 ½” (241mm) 9 ” (232mm) 9 ” (238mm) 9 ” (238mm)
Brand
Backwall with DW Pipe at 2 ” Centerline from backwall
ICC Ventis Security Selkirk DuraVent
6 ½” (165mm) 8 ¼” (210mm) 7 ¼” (184mm) 6 ¾” (171mm) 7 ¾” (197mm)
5 ½” (140mm) 5 ” (149mm) 5 ½” (140mm) 5 ¾” (146mm) 5 ¾” (146mm)
C Corner Installation at 9″ without wall protection
Brand
Chimney Centerline dimension
From corner and wall
ICC Ventis Security Selkirk DuraVent
15 ¼” (387mm) 14 ¼” (362mm) 14 ” (365mm) 12 ¼” (311mm) 11 ¾” (298mm)
M Corner Installation at 4″ with wall protection
Brand
ICC Ventis Security Selkirk DuraVent
Chimney Centerline dimension
From corner and wall 10 ¼” (260mm) 9 ¼” (235mm) 9 ” (244mm) 9″ (229mm) 9 ½”
(241mm)
U.S.
Canada
48 ” (1229mm) 50 ” (1273mm) 49 ” (1248mm) 48 ” (1235mm) 49 ” (1260mm)
52 ¾” (1340mm) 55 ” (1400mm) 56 ” (1426mm) 56 ” (1432mm) 56 ” (1445mm)
Front Edge of Hearth Extension From Rear Wall
U.S.
44 ¾” (1137mm) 46 ½” (1181mm) 42 ½” (1080mm) 45″ (1143mm) 46″ (1168mm)
Canada
49 ” (1248mm) 51 /” (1307mm) 52 ½” (1334mm) 52 ¾” (1340mm) 53 ¼” (1353mm)
ICC 45° Elbow Part Number VE-6UB45
Selkirk 45° Elbow Part Number 45073 DSP6E4-1
Ventis/Copperfield 45° Elbow Part Number 3602438 Security 45° Elbow Part Number 6DE45
Dura Vent 45° Elbow Part Number 6DVL-E45
15
Jøtul F 35 130074_2 7/24
5.0 Operation
Please read the following section before building the first fire in your new
Jøtul F 35 Rockwood.
5.1 Combustion Efficiency
The Jøtul F 35 Rockwood has an EPA tested High Heating Value (HHV) efficiency
rate of 68.47%. There are aspects of efficiency, however, that you should be
aware of in order to get the most from your stove.
Operation habits and fuel moisture can have a significant effect on
efficiency. Poorly seasoned wood having a higher than optimum moisture
content, can reduce the amount of energy transferred to the living area as a
result of the energy expended to evaporate the excess fuel moisture in order
for the wood to burn. Operational aspects, such as not building a robust
kindling fire to readily ignite the larger fuel pieces, can result in an
inefficient smoldering fire. Additionally, most modern wood heaters’ optimum
performance and efficiency are at the medium to medium -to-low burn rates.
The location of the stove can have a significant effect on heating efficiency,
primarily in regard to heat distribution. For example, a wood heater centrally
located in the residence in an open living area will likely provide better
circulation of heat than will a stove located in a room adjacent to the larger
living area.
5.2 Minimize Carbon Monoxide Emissions
Testing the F 35 Rockwood to CSA B414.1-10 resulted in a carbon monoxide
emission rate of 1.35 grams per minute. Most means of combustion produce CO,
including wood fires. Maintaining a wellestablished fire and avoiding
operation that produces a smoldering, smoky fire, will greatly reduce CO
levels.
It is highly recommended that a CO monitor (detector) be installed in the same
room as the stove. The monitor, however, should be located as far away as
possible from the stove to avoid alert soundings when adding fuel to the fire.
advantage of the stove’s low end efficiency strength. A seasoned log will have check marks (cracks) on the ends and be lighter than an unseasoned log which will show little or no check marks.
We recommend using a moisture meter to determine the moisture content of your wood. For purposes of home heating, your fuel should have a moisture content between 12 – 20%. Wood with higher moisture content will burn, however, very inefficiently. Most of its heat value will be lost to driving water out of the wood. Worse, that moisture will condense as creosote in the relatively cool chimney flue, increasing the potential for a chimney fire. Use of unseasoned wood defeats the purpose of any modern woodburning stove.
BURN UNTREATED WOOD ONLY. DO NOT BURN:
· Coal
· Garbage
· Synthetic fuel or logs
· Material containing plastics
· Materials containing asbestos · Unseasoned wood
· Manure or animal remains · Lawn clippings or yard waste
· Material containing rubber, including tires
· Waste petroleum products, asphalt products, paints,
paint thinners or solvents
· Construction or demolition debris
· Railroad ties or pressure-treated wood
· Salt water driftwood or other previously salt-water;
saturated materials
· Paper products, cardboard, plywood, or particle board. (The
prohibition against burning these materials does not prohibit the use
of fire starters made from paper, cardboard, saw dust, wax or similar
substances for the purpose of starting a fire.)
Burning of any of the materials listed above can result in the release of toxic fumes, cause smoke, or render the heater ineffective and cause smoke
· NEVER USE GASOLINE, GASOLINE-TYPE LANTERN FUEL, KEROSENE, CHARCOAL LIGHTER FLUID OR SIMILAR LIQUIDS TO START OR “FRESHEN-UP” THE FIRE. ALWAYS KEEP SUCH LIQUIDS AWAY FROM THE HEATER AT ALL TIMES.
5.3 Wood Fuel and Performance
Jøtul specifies the use of only 16″ fuel for several important reasons.
Foremost, the combustion system was specifically designed for optimum
performance with 16″ fuel. There can be several unwanted consequences of using
fuel longer than 16″. Longer fuel pieces can potentially diminish combustion
and emissions performance. Longer pieces can also present an interference with
proper door closing operation and potentially result in broken glass should
the fuel extend to the opening of the firebox
The F 35 Rockwood is designed to burn natural wood only. Higher efficiencies
and lower emissions generally result when burning air-dried, seasoned
hardwoods, as opposed to softwoods, green or freshly cut hardwoods. Wood that
has been air-dried for a period of 6 to 14 months will provide the cleanest,
most efficient heat. Wood seasoned more than 2 years will burn too quickly to
take
WARNING
ALWAYS WEAR STOVE GLOVES WHILE TENDING THE FIRE.
NEVER ALLOW THE FIRE TO REST DIRECTLY ON THE GLASS. KEEP THE LOGS SPACED AT
LEAST ONE INCH FROM THE GLASS TO ALLOW FOR PROPER AIR FLOW WITHIN THE STOVE.
AVOID STRIKING THE GLASS WITH LOGS.
OPERATE THIS STOVE ONLY WITH THE FRONT DOOR FULLY CLOSED. OPERATION WITH THE
DOOR PARTIALLY OPEN MAY RESULT IN OVERFIRING. IF THE DOOR IS LEFT PARTIALLY
OPEN, GAS AND FLAME MAY BE DRAWN OUT OF THE STOVE CREATING SAFETY RISKS FROM
BOTH FIRE AND SMOKE.
16
Jøtul F 35 130074_2 7/24
5.4 How Your Jøtul F 35 Works
When used with dry wood and a well-drafting chimney system, modern non-
catalytic wood stoves burn fuel efficiently by the precise control and
delivery of primary and secondary air to the fire.
Primary Air is drawn into a front inlet in the stove bottom and directed
through a regulator shutter under the front door before entering the lower
fire chamber. Additional primary air is directed to the top of the load door
to act as an air wash to help prevent extreme soot build-up on the glass
panel. The amount of primary air available to the fire determines the
intensity of heat output and rate of fuel combustion; the greater the amount
of air, the greater the heat output, the faster the wood burns. The primary
air setting also determines the effectiveness of the air wash over the glass;
the higher the setting, the cleaner the glass.
Additional air is separately directed into the top of the fire chamber to
support combustion of exhaust gasses before passing out of the stove. This
unregulated Secondary Air enters through an inlet in the rear of the stove
bottom and is heated as it passes through the rear of the stove into manifold
at the top rear of the firechamber. The secondary air is then directed through
a stainless steel baffle plate.
Volatile gases, released unburned from the fuel bed, rise to the baffle where
they are turbulently mixed with the hot, fresh oxygen. Secondary combustion
then occurs before the gases pass into the heat exchange chamber. The action
of secondary combustion can be readily seen through the viewing glass as slow,
rolling flames suspended over the main fuel bed and smaller jets of flame
extending from the baffle manifold ports. At the same time, no smoke will be
observed exiting the chimney. This is evidence that the stove is operating at
the so-called “sweet-spot” wherein optimum efficiency and lowest particulate
emissions are realized. See fig. 15.
Use a Stove-top Thermometer
Determining the primary air setting for the best overall performance for your
particular needs and installation will be established over time and
experience. Each installation has unique characteristics that affect stove
performance. You should use a stove-top thermometer to monitor the status of
the fire. Place the thermometer on the stove top, centered to one side or the
other. Generally speaking, once the stove temperature has reached 400°F –
600°F (204°C -316°C), the air control may be set in a mid-range position to
allow adequate oxygen to support efficient combustion throughout the burn
cycle.
You can also monitor stove performance through the window. Peak combustion
efficiency occurs when exhaust gas is burned at the baffle in the top of the
firebox. This is apparent as rolling yellow-orange flames appearing at the
secondary air ports in the underside of the baffle plate and forward tube. At
this stage, little or no smoke will be visible exiting the chimney.
Figure 15. Combustion air paths
5.5 Air Control Settings
Use the following guide for best performance.
Burn Rate Low
Medium High
Air Control Setting Fully Closed 1/2″ Open Fully Open
1/2″ 1/8″
Figure 16. Air Control Settings
5.6 Controlling the Fire
Combustion intensity is controlled by the position of an air shutter located
under the front door. You adjust its position using the handle located under
the ash lip. Slide the handle to the left to decrease air to the fire. Sliding
it to the right increases air delivery and consequently, fire intensity. See
fig. 16. The shutter regulates and directs primary air to the front of the
burn chamber. Push it to the right to allow maximum air to support combustion.
It should be fully open when first starting or rekindling a fire, or when
greater heat output is desired.
17
Jøtul F 35 130074_2 7/24
5.7 Break-In Procedure
Although your Jøtul F 35 is constructed of welded, 3/16″ steel plate, it also
incorporates cast iron components. This material requires the stove to be
”broken-in” gradually so that heat expansion does not occur too quickly and
cause damage. The following steps describe the proper break-in procedure for
your stove. Use a magnetic stove-top thermometer to monitor stove temperature,
placed directly on the cookplate.
Set the Primary Air Shutter fully open, all the way to the right. 1. Light a
small fire of newspaper and kindling at the front of
the stove. Gradually add small pieces of wood, but only allow the stove to
reach a maximum surface temperature of 200°F (93° C). Continue burning at this
low rate for approximately 1 hour. 2. Allow the stove to cool to room
temperature. 3. Light a second fire, allowing the stove to reach a maximum
temperature of 300°F (149°C) for 1 hour. 4. Cool the stove to room
temperature. 5. Light a third fire and gradually allow the stove to reach a
surface temperature of 400°F (204°C) 6. Cool the stove to room temperature.
This completes the “break-in” procedure.
Note: If the temperature exceeds the limit during any break-in fire, move the
Air Shutter all the way to the left to shut off the air supply completely. It
is normal that the stovetop temperature will continue to climb until the fuel
burns down somewhat. Once the fire is out and the stove has cooled to room
temperature, continue the break-in procedure. Never attempt to reduce the
temperature by removing burning logs from the fire.
Break-in Odors: It is normal for a newly-painted stove to emit odor and smoke
during the first few fires, and these may set off smoke alarms. This condition
is caused by curing of the high temperature paint and will diminish with each
subsequent fire. It is advisable to open windows or doors to provide plenty of
fresh air and cross-ventilation during the break-in period.
5.8 Starting and Maintaining a Fire
Burn only solid wood directly on the bottom of the stove firechamber. Do not
elevate the fire in any way.
See Section 8.1 of the Appendix on page 22 for detailed information regarding
the cordwood test method fire-building procedure from a cold start to a high
fire, medium fire or cold fire.
Top-Down Fire Building – See fig. 17.
Many people find this method to be superior to the traditional method.
1. With the primary air control lever in the full open position (to the
right), place two short 1/4-split logs on the firebox floor, perpendicular to
the rear wall, about 6 inches apart.
2. Place kindling across the base logs.
3. Place one or two smaller split logs on top of the kindling.
4. Place newspaper between the two bottom logs under the kindling. Light the
news paper and close the door. Continue to add kindling and small logs as
necessary to build the fire. Keep the air control fully open until the fire is
well-established.
5. Add more logs as the fuel bed become fully involved and use the stove-top
thermometer to monitor progress. When the stove has reached a surface
temperature range of between 400° and 600°, (204°C -316°C), adjust the primary
air control lever as necessary to generate the heat output and burn time
desired.
You can also monitor stove performance through the window. Peak combustion
efficiency occurs when exhaust gas is burned at the baffle in the top of the
firebox. This is apparent as rolling yellow-orange flames appearing at the
secondary air ports in the underside of the baffle plate and forward tube. At
this stage, little or no smoke will be visible exiting the chimney.
WARNING: NEVER OVER-FIRE THE STOVE. IF ANY PART OF THE STOVE OR CHIMNEY GLOWS,
YOU ARE OVER-FIRING. A HOUSE FIRE OR SERIOUS DAMAGE TO THE STOVE OR CHIMNEY
COULD RESULT. IF THIS CONDITION OCCURS, IMMEDIATELY CLOSE THE AIR CONTROL.
ATTEMPTS TO ACHIEVE HEAT OUTPUT RATES THAT EXCEED HEATER DESIGN SPECIFICATIONS
CAN RESULT IN PERMANENT DAMAGE TO THE HEATER.
18
Jøtul F 35 130074_2 7/24
Front of Stove
Figure 17. Top-down fire starting structure.
5.9 Adding Fuel
Follow this procedure when reloading the stove while it is still hot and a bed
of hot embers remains:
· Always wear gloves when tending to the stove.
· Adjust the Primary Air Shutter Lever to the fully open position – all the
way to the right. Wait a few seconds to re-establish strong draft before
opening the load door. This will allow fresh air to flush the firebox and
prevent smoke escaping when the door is opened.
· Minimize CO exposure: Open the door slightly, and hesitate a moment to allow
exhaust purge, then open the door fully.
· Use a stove tool or poker to evenly distribute coals and embers around the
firebox.
· Load the fuel, usually with smaller logs first.
· Close the door, being sure to latch the door tightly.
· Wait 5 10 minutes to re-establish the fire before setting the air controls
for the desired heat output and burn time. (If there is at least a 2″ thick
ember bed when reloading, it may be possible to close the door and immediately
adjust the air control setting).
· Set the Air Shutter for the desired heat output.
WARNING: Operate the stove only with the front door fully closed except for
refueling. Operation with the door partially open may result in overfiring.
Also, if the door is left partially open, combustion gas and flame may be
drawn out of the stove, creating risks from both fire and smoke.
5.10 Creosote Formation and the Need for Removal
When wood is burned slowly, it produces tar and other vapors that combine with
moisture to form creosote. Creosote vapors condense in the relatively cool
chimney flue, and creosote residue accumulates on the flue lining. When
ignited, this creosote fuels an extremely hot fire.
The chimney connector and chimney flue should be inspected at least every
other month during the heating season to determine if creosote buildup has
occurred. If creosote has accumulated, it should be removed to reduce the
chance of a chimney fire.
In the event that creosote ignites in the flue, the resulting fire is often
accompanied by a roaring noise and crackling sound as flakes of burning
creosote break loose. If you suspect you are having a chimney fire,
immediately close the air controls and make sure the door is closed securely.
Call the fire department and have everyone leave the house.
Do not attempt to extinguish the fire. Opening the door will only supply
additional oxygen and intensify the fire. When the fire in the flue has
subsided, resist the temptation to open the door to check on the fire. The
fire may have suffocated, but could reignite with a supply of fresh air. After
a chimney fire, do not use the stove until the chimney connector and flue have
been cleaned and inspected to ensure no damage has been sustained.
See Section 6.6 of this manual regarding chimney cleaning.
5.11 Ash Removal
Remove ashes whenever accumulation nears the primary air port located inside
the firechamber just under the door opening.
Always wear safety gloves when handling the ashes.
Ashes should only be placed in a metal container equipped with a tight sealing
lid. The container should be placed on a noncombustible floor or on the
ground, well away from all combustible materials, pending final disposal. If
the ashes are to be disposed of by burial in soil or otherwise locally
dispersed, they should be kept in the closed container until all cinders have
thoroughly cooled.
19
Jøtul F 35 130074_2 7/24
6.0 Maintenance
6.1 Door Latch Adjustment
Over time, as the door gasket becomes compressed, it may be necessary to
adjust the door latch in order to maintain the integrity of the door seal. To
check the front door seal, close and latch the door on a dollar bill and
slowly try to pull the bill free. You should feel resistance as you pull. If
it can be easily removed, the seal is too loose. Follow this procedure to
tighten the latch mechanism. Tools Required: · 4 mm hex key 1. Remove the two
socket head screws and latch keeper from the
stove. See fig. 18. 2. Remove one of the shim plates from the latch cavity and
re-
install the latch keeper. Retain the shim plate(s) removed for future use. 3.
Test the seal integrity using the dollar bill. The door gasket will compress
over time. When the latch can no longer be tightened by shim removal, install
a new gasket and replace the shim plates.
Figure 18. Latch adjustment.
6.2 Glass Care
Cleaning
On occasion it will be necessary to clean the carbon deposits and fly ash off
of the glass. If these deposits are allowed to remain on the glass for an
extended period of time, the surface may become etched and cloudy. Any
creosote that might develop on the glass will burn off during the next hot
fire.
Follow this glass cleaning procedure:
1. Glass must be completely cool. 2. Only use cleaning products specifically
formulated to clean
solid fuel appliance glass and follow the manufacturer’s instructions. Use of
abrasive compounds or solutions will damage the glass. DO NOT USE AMMONIA-
BASED GLASS CLEANERS. 3. Rinse and dry glass completely before burning the
stove. Polish with a piece of newspaper.
Caution! Always operate the door slowly and carefully to avoid cracking or
breaking the glass. Never use the door to push wood into the firebox. If the
glass becomes cracked or broken follow the replacement procedure in Section
6.5.
Never operate the stove with a cracked or broken glass panel.
Important: Replace glass only with ceramic glass panel PN 224923 specifically
designed for the Jøtul F 35, available from your local Jøtul dealer. Do not
substitute any other glass.
6.3 General Care
Regular maintenance will ensure excellent performance and prolong the life of
your stove. The following procedures do not take long and are generally
inexpensive. When performed consistently, they will lengthen the life of your
stove and provide many years of service.
· Regularly empty the stove of all soot and ashes. Only use a vacuum for this
job if the vacuum is specifically designed to handle ashes. CAUTION: Ashes may
contain hidden, live embers. Be certain the ash bed contains no live embers
before using a vacuum.
· Inspect the stove: Using a strong light inspect the stove inside and out for
cracks or leaks.
· Replace any broken bricks. See fig. 35, page 24. DO NOT OPERATE THE STOVE
WITH BROKEN OR MISSING BRICKS.
20
Jøtul F 35 130074_2 7/24
6.4 Gasket Replacement
Tools needed: · needle nose pliers · wire brush
· 4mm hex key · gasket cement
1. Use the pliers to remove the small C-clips from the door hinge pins.
Remove the door from the stove and place it face down on a protected surface.
2. Use the hex key to remove the warning label plate from the back of the
door.
3. Use pliers to remove the old gasket and adhesive from the door.
4. Thoroughly clean the channel with a wire brush. 5. Apply a small bead of
gasket cement to the channel as shown
in fig. 19. DO NOT APPLY CEMENT TO THE GLASS CLIPS OR THE CLIP LANDING AREAS.
6. Starting at the center of the gasket length and the top center of the
channel, gently press each gasket half into the channel. Do not stretch the
gasket. Wrap the ends at the center of the bottom as shown in fig. 19. 7.
Replace the Warning Plate. 8. Replace the door. Close and latch the door and
then reopen. Wipe away any excess cement that may have squeezed out from
around the gasket. 9. Replace the C-clips onto the hinge pins.
6.5 Glass Replacement
Tools needed: · 4mm hex key
1. Lift the door gasket over the glass clips enough to expose the clip button
head screws. See fig. 20. Use the 4mm hex key to loosen the glass clips just
enough to remove the glass panel. It is not necessary to completely remove the
clips from the door.
If replacing the glass gasket, follow steps 3-5 in section 6.4.
2. Position the new glass panel and tighten the glass clips just snug. Avoid
overtightening or placing uneven pressure on the glass.
3. Reposition the door gasket over the glass clips.
Description 1. Door Gasket 2. Glass Gasket 3. Screw, M6x10 Button Hd. 4. Glass Clip Ass’y. 5. Glass Panel 6. Warning Plate
Part Number
223858 200024 117978 157642 224923 226905
Gasket Cement Area
Figure 20. Loosen the glass clips.
4
Glass Clip LandingAPPLY NO CEMENT
5 2
3 1
6
4
3
Figure 19. Glass and Gasket Replacement
3
21
Jøtul F 35 130074_2 7/24
6.6 Chimney System
The Jøtul F 35 is designed to burn cleanly and efficiently when used according
to the guidelines in this manual. In order to maintain proper performance, you
should inspect the chimney and chimney connector at the beginning of each
heating season and then every other month during the heating season. Clean the
chimney whenever creosote and fly ash accumulation exceeds 1/4 inch in any
part of the system.
Chimney brushes are available from your local Jøtul dealer or hardware supply
store. Your dealer can also refer you to a reputable, professional chimney
sweep who will have all the equipment to ensure a complete and proper job.
WARNING: FAILURE TO KEEP THE CHIMNEY CONNECTOR AND FLUE FREE OF CREOSOTE
BUILD-UP CAN RESULT IN A CHIMNEY FIRE.
6.7 Replace Firebricks
DO NOT OPERATE THE STOVE WITH BROKEN OR MISSING BRICKS. See fig. 35, page 28
and the parts listing on page 29 for the configuration and part number of any
firebricks that require replacement. Order bricks through your local Jøtul
authorized dealer.
6.8 Secondary Manifold
Inspection
Visual inspection of the manifold can be conducted through the front door
opening. Check for evidence of warping or cracks and replace if damaged.
3 5
Insulation Blanket
6 1
4
Rear Shroud
Figure 21. Secondary Baffle removal.
Flame Deflector
2
Tools Required · 10 mm wrench or socket driver · wire brush · pliers · 1/4″
socket driver or flat head screwdriver · 4 mm hex key
· Work gloves
Cleaning and Removal / Fig. 21.
1. Remove the Top Plate M6 set screws (#1), one on each side of the stove.
Lift the plate off the stove and place it on a protected surface.
2. Lift the steel Flame Deflector (#2) up off of the two shoulder fasteners
at the front lip of the firebox and remove it through the front door opening.
3. Lift the Ceramic Insulation Blanket (#3) off the top of the Secondary
Manifold (#6) and out of the stove. Place it on a flat surface, taking care to
retain its shape.
4. Remove the Rear Shroud by removing two 1/4″ set screws (#4) from each side
of the back of the stove. Place the shroud on a protected surface taking care
not to scratch painted surfaces.
5. Remove the two, M6 Baffle Retainer bolts (#5).
6. Lift the Baffle and Turbulator Assembly (#6) out of the firebox. Clean and
inspect the assembly for cracks, warping or other deterioration. Contact your
Jøtul authorized dealer for replacement parts.
7. Reverse steps to reassemble.
22
Jøtul F 35 130074_2 7/24
7.0 Accessory Installation
7.1 Short Leg Kit 157636
Approved for use only in existing code-approved masonry fireplace hearth-mount
installations.
Contents: 4 1/4″ Steel Legs, (4)
Tools Required: · 13 mm wrench or socket/ratchet · work gloves
DO NOT LIFT THE STOVE UP BY THE ASH LIP.
1. Have an assistant tilt the stove up on one side enough to remove the cast
iron legs. Fully remove the nuts from the leg studs.
2. Engage the steel leg with the mounting stud. Be certain the two locating
tabs on each leg seat with the corner pockets in the stove bottom. Tighten the
nuts and carefully set the stove back down.
CAUTION: Avoid injury- always wear safety gloves when handling sheet metal
parts. Read through these instructions to familiarize yourself with the parts
before beginning the installation.
Figure 22. Short Leg installation
Tab Pockets
Locator Tab
7.2 Outside Air Kit 158265
Contents: · Outside Air Manifold
Tools Required: · 10 mm and 1/4 ” socket drivers
· safety glasses · work gloves
You will need the following additional components available at any
hardware supplier: · Exterior Air Inlet Cover · 4″ Aluminum Duct
· Rodent Screen · 4″ Duct Clamps, 2
The exterior air inlet should be installed at a level lower than the stove
bottom. 1. Remove Bottom Heat Shield: Use the 10 mm socket driver or
wrench to remove the four nuts and the Bottom Heat Shield from the studs in
the stove bottom as shown in fig. 23. Also remove the four remaining spacer
nuts from the studs.
2. Attach the Outside Air Manifold directly to the stove bottom using four of
the nuts previously removed.
3. Use pliers to remove the air inlet cut-out from the bottom heat shield.
4. Attach the bottom heat shield to the outside air manifold using four sheet
metal screws from the Outside Air Kit.
If the bottom heat shield will not be used, install the sheet metal screws
supplied with the outside air kit to plug the associated holes in the
manifold.
Figure 23. Outside Air Adaptor installation.
Remove four nuts and use to attach the manifold. Manifold
Manifold Nuts
Manifold Nuts
Heat Shield
Figure 24. Floor Bracket Detail
7.3 Mobile Home Floor Bracket Kit 157321
Contents: Floor Brackets , (2)
Fastener Required: 3/8″ dia. lag screw
1. Determine the final location of the stove and use the leveller screws to
plumb and level the stove.
2. Mount the floor brackets over the leveller screws at rear and front
locations at opposite corners and secure each to the floor using a 3/8″ dia.
lag screw of appropriate length, (not supplied).
SSLcLcraaergegww
23
Jøtul F 35 130074_2 7/24
8.0 Appendix
8.1 F 35 Start-Up and Refueling
Follow these directions to get the best emissions performance from your F 35:
Cold Start
Use the following technique for the best start from a “cold” stove:
1. Cut and split approximately 15 kindling pieces 16 inches long. Half of
them should be approximately 3/4 inch square, the rest 1/2 inch square. The
kindling should be very dry and weigh approximately 3 lbs.
2. Cut and split approximately 15 start-up fuel pieces 16 inches long. Half
of the pieces should be larger cross-section (approximately 1 1/2 inches
square) and the rest smaller cross-section (approximately 1 inches square).
These can be split from larger fuel pieces that are in the range of 19-25%
moisture (Dry-basis). The total weight of the start-up fuel should be
approximately 4.5 lbs.
3. Arrange the start-up fuel pieces in a grid as shown in figs. 24-28. Place
two of the larger pieces about six inches apart going front to back. Next, two
more pieces the same size left to right about six inches apart. See fig. 24.
Place about seven of the small pieces front to back on top of the gird. Place
the remaining start up fuel sideways on top. See figs. 25-26.
4. Next, arrange the kindling pieces in a similar alternating grid pattern
with the larger pieces first followed by the smallest with a layer of three
pieces going left to right as shown with six or seven pieces on the top. See
fig 27.
5. To start, make sure the air control is pushed all the way to the right.
6. Using a propane torch, light the top front of the kindling grid. The torch
should be operated for 60 seconds.
7. Close the door until it hits the latch. This will leave the door in a
slightly open position.
8. After one minute, close the door fully and secure the door latch.
9. Make sure the air control is still in the maximum open position.
Figure 24. Arrange larger fuel start-up pieces on bottom
Figure 25. Arrange smaller fuel start-up pieces on top of grid
Figure 26. Arrange remaining fuel start-up pieces
Figure 27. Arrange kindling in grid pattern on top
24
Adding the High Fire fuel load
1. When the kindling and start-up fuel have burned down by approximately 2/3,
rake the remaining coals and fuel pieces forward until they are equally
distributed and level.
2. Place the largest fuel piece in the center of the firebox with two smaller
pieces on the either side packed tightly together and making sure there is
space on both sides of the load for good air flow. Place the remaining pieces
on top of the bottom pieces. All fuel pieces should be in a front-to-back
orientation. Air control should be set to maximum open (all the way to the
right).
Medium Fire Fueling and Operation (loading on coals after High Fire
operation):
1. At the end of the high fire rake the remaining coals forward until they
are equally distributed and level across the firebox.
2. Place the largest piece in the center of the firebox with two smaller
pieces on either side, packed tightly together making sure there is space on
both sides of the load for good air flow. Place the remaining pieces on top.
All fuel pieces should be in a front-to-back orientation.
3. Immediately close the load door and set the air control to maximum open
(all the way to the right).
4. After 5 minutes set the control to the medium air flow position in the
center of its range of travel
Low Fire Fueling and Operation (loading on coals after High Fire operation):
1. At the end of a high fire, rake the remaining coals forward until they are
equally distributed and level across the firebox.
2. Place the three largest pieces in first; they should be close together.
Place the remaining pieces on top of the first in the same way.
3. Immediately close the door and open the air control to maximum open (all
the way to the right).
4. Leave the air control on the maximum setting for 10 minutes and then set
it to medium. After 5 minutes at medium, push the air control all the way to
the left for a controlled low burn.
Jøtul F 35 130074_2 7/24
25
Jøtul F 35 130074_2 7/24
9.0 Jøtul F 35 Illustrated Parts
Only use replacement parts provided through your authorized Jøtul dealer.
Figure 35. F 35 Illustrated Parts List
26
Jøtul F 35 130074_2 7/24
No. Description
Part Number
1. Screw, Button Head Socket – M6 x 10 Blk 117978
2. Glass Clip, 5″ w/ Gasket
157642
3. Gasket, Flat, V125x8mm, Self Adhesive 127215
4. Door Glass, Ceramic
224923
5. Gasket, MD .625 Ø Fiberglass Rope
223858
6. Gasket, LD .250 Ø Fiberglass Rope
200024
7. Screw, Button Head Socket M6 x 10 Blk 117978
8. Retainer, Front Door Latch
224159
9. Roll Pin, Slotted 5mm x 24, steel
118251
10. Shim, Latch Receiver
224734
11. Latch Receiver, Front Door
224733
12. Screw, Button Head Socket, M6 X 14, Blk 118215
13. Front Door Tool
157635
14. Screw, HWH SMA 8 x 1/2 SL Blk Oxide 117917
15. Rear Shroud, F 35
22675092
17. Inspection Cover, F 45
224924
18. Gasket, Inspection Cover
224355
19. Screw, Shoulder M6 x 10, Hex
117982
20. Air Valve Weldment
226882
21. Air Valve Handle Ass’y, Nickel Plated
157391
23. Disc Spring,
118249
24. Washer, Fender 8mm Zinc
117949
25. Side Panel, Convection, MB D&T
158266
26. Firebox assembly
226743
27. Nut, M8, Serrated Flange, ANSI B 18.2 117881
28. Heat shield, Bottom
22675192
29. Washer, Thin Shim
117588
30. Hinge pin, New Style, Nickel Plate
125960
31. E Clip
118261
32. Bolt, Hex Serrated Flange M6 x 20 Blk
117117
33. Bracket, Bttm, Cast Convection Panel, 50 TL224197
34. Brick, Refractory, 6.625 x 4.50
224723
35. Brick, Refractory, 8.5″ x 4.5″ x 1.25″
221751
36. Brick, Refractory, 8.5″ x 3″ x 1.25″
221752
37. Brick, Refractory, 4″ x 3″
224175
No. Description
Part Number
38. Brick, Refractory, 4.50″ x 9″ x 1.25″
129082
39. Brick, Refractory, 8″ 2.5″ x 1.25″
226871
40. Brick, Refractory, 9″ x 3.375″ x 1.25″ 222226
41. Baffle Support, Left
226752
42. Baffle Support, Right
226753
43. Smoke outlet, MB
105055
44. Bracket, Cast Top Retaining
103713
45. Bolt, Hex Head Serr Flange M6x16 8.8 Blk 99625
46. Gasket, Flue Collar, F35
226874
47. Nut, M6 Serrated Flange plain
117968
48. Deflector, Exhaust
226464
49. Screw, Button Head Socket M6 x 10 Blk 117978
50. Bracket, Top, Cast Convection Panel
226582
51. Screw, Socket Set, M6 x 16
118031
52. Washer, Fender .250 x 1.500 dia.
118029
53. Ash Lip, MB D&T
157645
54. Baffle Weldment, F 35
226754
55. Turbulator Assembly
226755
56. Blanket, F35 Ceramic Fiber
226872
57. Leveler Bolt, M8
118047
58. Leg, Steel Stoves, MB, D&T
157346
59. Gasket, MD, .625 Ø Fiberglass Rope
223858
60. Set Screw, M8 x 40, Hex Socket, Black 118245
61. Top Plate, Front, F 45, MB, D&T 62. Clip, Side
157655 120120
63. Gasket, LD 250 Fiberglass Rope
200024
64. Top Cover, MB, D&T
157647
65. Door, Front, w/Gasket, F 45, MB
157648
66. Safety Warning Plate
226905
67. Latch, Front Door w/ Roll Pin
224979
68. Screw, Socket Set, M6 x 20
117835
69. Gasket, Secondary Ledge
225021
70. Spacer, .250 x .500
117994
71. Bolt, shoulder, M6 x 6
118244
72. Deflector, Side
226870
73. Bolt, Hex Serrated Flange M6 x 16 Blk
117130
27
Jøtul F 35 130074_2 7/24 This page is intentionally blank.
28
Jøtul F 35 130074_2 7/24 This page is intentionally blank.
29
Jøtul F 35 130074_2 7/24 This page is intentionally blank.
30
Jøtul F 35 130074_2 7/24
10. F 35 Warranty Statement
Effective January 1, 2013
This warranty policy applies to wood-burning products identified by Jøtul
trade names, as set forth below.
A. LIMITED LIFETIME WARRANTY, parts only: Jøtul North America Inc. (JØTUL)
warrants, to the original retail purchaser, that those baffle and air manifold
components of the Jøtul Stove or Fireplace Insert specified above will be free
of defects in material and workmanship for the life of the product. This
warranty is subject to the terms, exclusions and limitations set forth below.
B. LIMITED FIVE YEAR WARRANTY – Cast Iron and Steel Components: JØTUL
warrants, to the original retail purchaser, that those components of the Jøtul
or Scan Stove or Fireplace Insert specified above will be free of defects in
material and workmanship for a period of five (5) years from the date of
purchase. This warranty is subject to the terms, exclusions and limitations
set forth below.
C. LIMITED TWO YEAR WARRANTY – Enamel Finish: JØTUL warrants, to the original
retail purchaser, the enamel finish on cast iron components of the Jøtul Stove
or Fireplace Insert specified above against peeling or fading for a period of
two (2) years from the date of purchase. This warranty is subject to the
terms, exclusions and limitations set forth below.
D. LIMITED ONE YEAR WARRANTY – Electrical Components (blowers, thermostatic
switches): JØTUL warrants, to the original retail purchaser, that those
components of the Jøtul or Scan Stove or Fireplace Insert specified above will
be free of defects in material and workmanship for a period of one (1) year
from the date of purchase. This warranty is subject to the terms, exclusions,
and limitations set forth below:
JØTUL will repair or replace at its option, any of the above components
determined by JØTUL to be covered by this warranty. You must, at your own
expense, arrange to deliver or ship the component to an authorized Jøtul
dealer and arrange for pickup or delivery of the component after repairs have
been made. If, upon inspection, JØTUL determines that the component is covered
by this warranty, the repair or replacement will be made as set forth above.
This warranty is not transferable and is extended only to, and is solely for
the benefit of, the original retail purchaser of the Jøtul Stove or Fireplace
Insert. This paragraph sets forth the sole remedy available under this
warranty in the event of any defect in the Jøtul Stove or Fireplace Insert.
The warranty period for any replaced component will be the remaining unexpired
portion of the warranty period for the original component. Please retain your
dated sales receipt in your records as proof of purchase.
EXCLUSIONS AND LIMITATIONS NOTICE: This warranty is void if installation or
service is performed by someone other than an authorized installer or service
agency, or if installation is not in conformance with the installation and
operating instructions contained in this owners manual or local and/or
national fire and building regulations. A listing of local authorized
installers, service agencies and gas suppliers can be obtained from the
National Fireplace Institute at http://www.nficertified.org/.
This warranty does not cover the following parts or conditions:
-
Repair or replacement of parts that are subject to normal wear and tear during the warranty period or to parts that may require replacement in connection with normal maintenance. These parts include paint, gaskets, burn plates, firebricks, fire grates, ceramic insulation blankets or glass (glass is warranted only against thermal breakage).
-
Damage due to incorrect installations not in conformance with the installation instructions contained in this owners manual or local and/or national fire and building regulations.
-
Damage, including damage to enamel surfaces, caused by improper operation, over-firing, and/or misuse. Improper operation, such as burning the stove with the ash door open, can damage the stove.
Over-firing occurs when any part of the stove glows red. Over-firing can also be identified by warped plates, rust-colored cast iron, paint pigment that has turned dusty white, or bubbling, cracking and discoloration of the enamel finish. Misuse includes, without limitation, use that is not in conformance with the operating instructions contained in this owners manual. -
Damage due to, or repair of, rust. Use of stove-top steamers may cause rust.
-
Damage due to service performed by an installer or service agency, unless otherwise agreed to in writing by JØTUL.
-
Damage caused by unauthorized modification, use or repair.
-
Costs incurred by travel time and/or loss of service.
-
Labor or other costs associated with the repair of components beyond the warranty period.
-
Damage incurred while the Jøtul Stove or Fireplace Insert is in transit.
IN NO EVENT SHALL JØTUL, ITS PARENT COMPANY, SHAREHOLDERS, AFFILIATES, OFFICERS, EMPLOYEES, AGENTS OR REPRESENTATIVES BE LIABLE OR RESPONSIBLE TO YOU FOR ANY SPECIAL, INDIRECT, INCIDENTAL, CONSEQUENTIAL, PUNITIVE OR OTHER SIMILAR DAMAGES, INCLUDING, BUT NOT LIMITED TO, LOST PROFITS, LOST SALES, INJURY TO PERSON OR PROPERTY, OR DAMAGES TO A STRUCTURE OR ITS CONTENTS, ARISING UNDER ANY THEORY OF LAW WHATSOEVER. ALL IMPLIED WARRANTIES, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, OR OTHERWISE, ARE LIMITED IN DURATION TO THE LENGTH OF THIS WRITTEN WARRANTY. EXCEPT AS EXPRESSLY SET FORTH HEREIN, JØTUL MAKES NO ORAL, WRITTEN OR OTHER WARRANTY WITH RESPECT TO JØTUL OR SCAN STOVES OR FIREPLACES.
Some states do not allow the exclusion or limitation of incidental or consequential damages, or limitations on the length of implied warranties. Therefore, the above exclusions or limitations may not apply to you. This warranty gives you specific legal rights, and you may have other rights, which vary from state to state.
JØTUL reserves the right to discontinue, modify or change the materials used to produce the Jøtul Stove or Fireplace. JØTUL shall have the right to replace any defective component with substitute components determined by JØTUL to be of substantially equal quality and price.
The dollar value of JØTULs liability for breach of this warranty shall be limited exclusively to the cost of furnishing a replacement component. JØTUL shall not in any event be liable for the cost of labor expended by others in connection with any defective component. Any costs or expenses beyond those expressly assumed by JØTUL under the terms of this warranty shall be the sole responsibility of the owner(s) of the Jøtul Stove or Fireplace Insert.
No dealer, distributor, or other person is authorized to modify, augment, or extend this limited warranty on behalf of JØTUL. NO MODIFICATION OR CHANGE TO THIS WARRANTY WILL BE EFFECTIVE UNLESS IT IS MADE IN A WRITTEN DOCUMENT MANUALLY SIGNED BY AN AUTHORIZED OFFICER OF JØTUL.
An authorized installer may have been provided with certain information related particularly to the Jøtul Stove or Fireplace Insert; however, no authorized installer or other person who may service the appliance is an agent of JØTUL. No inference should be made that JØTUL has tested, certified, or otherwise pronounced any person as qualified to install or service the appliance. JØTUL shall not be liable or otherwise responsible for any error or omission by a person installing or servicing a Jøtul Stove or Fireplace Insert.
If you believe your Jøtul or Fireplace Insert is defective, you should contact your nearest authorized Jøtul dealer, who will process a warranty claim. IN ORDER TO QUALIFY FOR WARRANTY COVERAGE, JØTUL MUST RECEIVE NOTICE OF A POSSIBLE DEFECT WITHIN SIXTY (60) DAYS OF THE DATE THE DEFECT IS FIRST DISCOVERED, OR REASONABLY COULD HAVE BEEN DISCOVERED.
This warranty is given by Jøtul North America, Inc., 55 Hutcherson Drive, Gorham, Maine 04038 USA
31
130074 _2 August 2024
Jøtul F 35 130074_2 7/24
Quality
We appreciate your trust in welcoming our product into your home and invite
your comment and appraisal of our efforts to provide you with the finest in
home hearth products. Jøtul pursues a policy of continuous product
development. Products supplied may therefore differ in specification, color
and type of accessories from those illustrated and described in this manual.
Jøtul North America Inc. P.O. Box 1157 55 Hutcherson Drive Gorham, Maine 04038
USA Jøtul AS P.O. Box 1411 N-1602 Fredrikstad, Norway www.jotul.us
32
References
- Jøtul | Cast iron wood stove, gas stove, wood burning & gas fireplace insert
- National Fireplace Institute (NFI) – The national certification division of the Hearth, Patio & Barbecue Education Foundation (HPBEF)
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>