Battery Installation
Remove the cover
Remove the batteries (if fitted).
Insert the Danfoss Ally™ Power Module 24V in the same place.
Use the cover provided in the box.
Connect the cable to the existing 24 V supply from a safe source with class II insulation level (Power supply with built-in double or reinforced insulation level between supply voltage and safe voltage).
When using Danfoss Ally™ Protect RA it is important to install Danfoss Ally™
Power
Module 24V before completing the installation of Danfoss Ally™ Protect RA. The
cable should go inside one of the cable tracks.
Safety precautions
Danfoss Ally™ Power Module 24V is designed to be used together with Danfoss
electronic radiator thermostats only.
SIMPLIFIED EU DECLARATION OF CONFORMITY Hereby, Danfoss A/S declares that
Danfoss Ally™ Power Module 24V is in compliance with Directive EN/IEC
60730-1:2011 and EN/IEC 63000:20018. The full text of the EU declaration of
conformity is available at the following internet address:
www.danfoss.com.
24 V supply must be from a safe source with class II insulation level (Power
supply with build-in double or reinforced insulation level between supply
voltage and safe voltage). The power module is not intended for children and
must not be used as a toy. Do not leave packaging materials where children may
be tempted to play with them, as this is extremely dangerous. Do not attempt
to dismantle the power module as it contains no user-serviceable parts.
Technical Specifications
Power supply | Input: 24V~ or 24V== SELV +/-25% |
---|---|
Output: 3V== -5%/+25% | |
Transportation temperature range | -20 to 65 °C |
Safety classification | Type 1 |
Pollution degree 2 | PD2 |
Overvoltage category I | OVI 1,5 kV |
Homepage:
www.danfoss.com
Danfoss cannot accept any responsibility for possible errors in catalogues, brochures, videos and other material. Danfoss reserves the right to alter its products without notice. This also applies to products ordered but not delivered provided that such alterations can be made without changes to form, fit or function of the product. All trademarks in this material are property of Danfoss A/S or Danfoss group companies. Danfoss and the Danfoss logo are trademarks of Danfoss A/S. All rights reserved.