INLINE 26114 3000 Series Square Ambient User Manual
- June 10, 2024
- inLine
Table of Contents
- INLINE 26114 3000 Series Square Ambient
- Product Information
- Product Usage Instructions
- INTRODUCTION
- Warranty
- OPERATION
- Preparation
- TROUBLESHOOTING
- CLEANING
- INSTALLATION
- SERVICING
- SPECIFICATIONS
- ELECTRICAL CIRCUIT DIAGRAMS
- SPARE PARTS
- MECHANICAL DRAWINGS
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
INLINE 26114 3000 Series Square Ambient
Product Information
The 3000 Series Square Ambient is a cabinet designed for storage and display of various products, available in widths of 600mm, 900mm, 1200mm, and 1500mm with fixed front or sliding rear doors. The cabinet can be used as an in- counter, on-counter, or freestanding unit. The product manual number is 26114 REV K NOV 2021.
Warnings
- This appliance is not intended for use by young children or infirm persons unless they have been adequately supervised by a responsible person to ensure that they can use the appliance safely.
- You should supervise young children to ensure that they do not play with the appliance.
- Do not use a water jet spray to clean the interior or exterior of this cabinet as it is not waterproof.
- Explosive substances like aerosol cans with flammable propellant should not be stored in this appliance.
- If the supply cord is damaged, it must be replaced by the manufacturer, its service agent, or similarly qualified persons to avoid a hazard.
- The cabinet does not contain asbestos, PCBs, oils containing polychlorinated biphenyl, or mercury in its construction.
Product Usage Instructions
Controls
The cabinet has a control panel for regulating temperature and displaying information about the unit. The control panel is located on the front of the cabinet.
Power and Lights
The cabinet requires a power supply to function. The power supply cord must be plugged into a properly grounded outlet. The cabinet also has internal lights to illuminate the products, which will turn on or off based on the cabinet’s temperature control settings.
Cleaning
The cabinet must be cleaned regularly to maintain hygiene and prevent the growth of bacteria. Use a soft, damp cloth to clean the interior and exterior of the cabinet. Do not use a water jet spray to clean the unit. For tough stains, use a mild detergent diluted in warm water. Avoid using abrasive cleaners or scouring pads that could scratch the cabinet’s surface.
Troubleshooting
A troubleshooting guide is included in the product manual for common issues that may arise while using the cabinet. If the problem persists, contact the manufacturer or an authorized service agent for assistance.
- Copyright © NOV 2021 Future Products Group Limited.
- All rights reserved.
- No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopying, recording or otherwise, without the prior written permission of Future Products Group Ltd.
Warnings
Operational Safety
- This appliance is not intended for use by young children or infirm persons, unless they have been adequately supervised by a responsible person, to ensure that they can use the appliance safely.
- Young children should be supervised, to ensure that they do not play with the appliance.
Water
- THIS UNIT IS NOT WATERPROOF. DO NOT USE A WATER JET SPRAY TO CLEAN THE INTERIOR OR EXTERIOR OF THIS CABINET.
Caution
- Do not store explosive substances, such as aerosol cans with flammable propellant, in this appliance.
Mains Supply Cord
- If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons, in order to avoid a hazard.
Hazardous Substances
- The cabinet does not contain any of the following, in its construction: Asbestos PCBs (Oils containing polychlorinated biphenyl) Mercury
INTRODUCTION
Welcome
AMBIENT CABINETS – INTRODUCTION
- Future Products Group (FPG)
- Welcome to the world of FPG! Our products are designed and engineered to give you the optimal performance that you deserve with innovative visual merchandising appeal.
- We are confident that you will be delighted with your state-of-the-art inline food service cabinet, and that it will become a valued appliance in your store.
- Guidance and Help
- Any new appliance can seem very complex and confusing at first glance. To ensure you receive the utmost benefit from your new inline cabinet, there are two things you can do.
- Before operating the cabinet, please read the instruction book carefully and follow its recommendations. The time taken will be well spent. These instructions both general and technical tell you how to install, operate and look after your inline food service cabinet so that you can receive the full benefits that this cabinet has to offer.
- These instructions cannot, however, cover all eventualities. If you are unsure of any aspect of the installation, instructions, or performance of your cabinet, contact your dealer promptly or contact us via email at support@fpgworld.com.
Warranty
AMBIENT CABINETS – INTRODUCTION
- Warranty Period
- Future Products Group Limited warrants, to the original purchaser of an FPG-manufactured food service cabinet that for ONE YEAR (12 months), from the date of purchase, any defect in workmanship or material resulting in the product malfunctioning while under correct use will be rectified.
- Liability under this warranty is limited to replacing or repairing a part, without charge.
- Liability Exceptions
- Liability under this warranty does not include:
- Any loss, or damage or expenses directly or indirectly arising from the use or inability to use the product or from any other cause.
- Any part of the cabinet which has been subject to misuse, neglect, alteration, incorrect installation, accident, or damage caused by transportation, use of abrasive or caustic chemicals, flooding, fire, or acts of God.
- Any damage or malfunction resulting from the use of non-FPG-supplied spare parts.
- Specific Exclusions
- The following are specifically excluded from warranty:
- Breakage of glass or plastic components, or the replacement of LED lighting and lamps, or gaskets.
- Failure to re-assemble the cabinet correctly after cleaning.
- Fair wear and tear.
- Assessment
- The liability under this warranty is dependent on an assessment by FPG, to determine the defect in workmanship or materials.
- Time Limit
- FPG does not guarantee that any service to be performed under this warranty will be carried out within any particular time limit.
- Caution
- FPG will not be held responsible for any servicing costs incurred prior to FPG’s acceptance of a warranty claim.
OPERATION
Cabinet Layout
- AMBIENT CABINETS – OPERATION
- 3000 Square Series Cabinets
- The 3000 Square Series cabinets include Ambient, Heated and Refrigerated models.
- On Counter, In Counter and Free Standing models are available.
- Door Configuration
- Sliding doors can be fitted to the front and back of the cabinets.
- Fixed glass can be fitted in place of doors at the front.
- Shelf Lighting
- Cabinets are fitted with a top light as standard. Lights below each shelf are available as an optional extra, at the time of ordering.
- Cabinets are fitted with high efficiency LED lighting.
Controls
AMBIENT CABINETS – OPERATION
- Control Panel
- The controls are mounted on the back of the cabinet, at the top.
- Power and Lights
- To turn the power and lights on, rotate the main switch.
- The lights and extractor fan will operate.
Preparation
AMBIENT CABINETS – OPERATION
Shelf Location and Ticketing
- The shelves are adjustable in height and can easily be moved up or down, to match product size.
- The movement is restricted to 50mm, because of the electric cables to the lights. For greater movement contact the manufacturer or supplier for advice, as electrical modifications may be required.
- The front and rear edges of the shelves are profiled to carry ticketing/labels.
- Shelf Adjustment
- To move the shelf brackets, first, remove the shelf trays.
- Lift the brackets straight up firmly and then pull the brackets forward, to disengage them from the slots in the support posts.
- Insert the brackets into their new position, and push the bracket down firmly.
- The brackets may be positioned to give two different degrees of slope to the shelves.
- Refit all shelf trays and doors.
- N.B. Make sure brackets are pushed down as far as they can go. Failure to do this may result in shelf collapse when loaded with product.
- Fumes and Odours
- Before first use, operate the cabinet for 1-2 hours with the doors open, to remove any fumes or odors, which may be present. This will avoid possible tainting of food.
- Close Doors
- It is important to keep the cabinet doors closed during normal use, to prevent food from drying out.
- Turn on Lights
- When ready for service, turn on the cabinet lights.
TROUBLESHOOTING
FAULT | POSSIBLE CAUSE | REMEDY |
---|---|---|
**** Cabinet does not operate/start | The mains isolating switch on the wall, | |
circuit breaker or fuses are off at the power board | **** Turn isolating |
switch circuit breaker or fuses on
Internal fuse has blown| Have wiring checked and replace fuse (5A
Slow Blow)
The main switch on the cabinet is OFF| Turn the main switch ON
** Cabinet lights not working| The main switch is OFF| Turn the switch ON
LED Power supply has failed| Replace LED power supply
LED strip has failed| Replace the LED assembly
Fuse has blown| Check wiring and replace fuse (5A Slow Blow)
** Doors are not sliding smoothly| Door not in track| Install door
correctly in track
Debris in track| Clean door tracks (see cleaning)
Lack of lubricant| Apply food grade lubricant to door track
Aluminium parts corroded| Caustic detergent damage| Order replacement parts
Service Personnel Only
The table entries in italics indicate actions to be taken only by qualified
Service Personnel.
CLEANING
Cautions
AMBIENT CABINETS – CLEANING
- Power
- ALWAYS TURN THE POWER SUPPLY OFF BEFORE CLEANING.
- Water
- THIS UNIT IS NOT WATERPROOF. DO NOT USE A WATER JET SPRAY TO CLEAN THE INTERIOR OR EXTERIOR OF THIS CABINET.
Exterior
AMBIENT CABINETS – CLEANING
- Metal Surfaces
- Stainless steel or aluminium surfaces should be cleaned with hot soapy water or a good quality metal cleaning compound. DO NOT clean surfaces with abrasive pads or cleaners, as stainless steel and aluminium surfaces will be damaged.
- Glass
- All glass should be cleaned using a good quality glass cleaner and a clean cloth.
- DO NOT use abrasive pads or cleaners, because they will damage the surface of the glass.
- Sliding Doors
- Sliding glass doors are located by plastic guides at the top and bottom.
- The doors can be removed for cleaning by sliding the door to a central position, placing hands either side of the door, lifting it up and then swinging it out at the bottom.
- When replacing doors, make sure that they are located in the correct slots, top and bottom. The left door should be in the inner slots, and the right door in the outer slots. Sliding door tracks should be vacuumed out regularly to keep doors sliding freely.
Interior
AMBIENT CABINETS – CLEANING
- Access to the Cabinet Interior
- Remove the doors, by sliding them to the centre and lifting, to disengage them from the door tracks.
- Lift out the deck trays.
- The cabinet interior can now be cleaned.
- Trays and Shelves
- Stainless steel trays and shelves should be cleaned with hot soapy water. Do not use abrasive pads or cleaners, as these may damage surfaces.
- Warning: Dishwasher detergents will damage any anodised aluminium parts
Routines
AMBIENT CABINETS – CLEANING
- Schedules
- To maintain optimum performance, regular cleaning schedules should be established.
- Inspection
- As part of the cleaning routine, the controls, mechanical parts and electrical wiring should be inspected for damage, deterioration or need of adjustment.
- Fault Correction
- If any small faults are found, have them attended to promptly by a competent serviceman. Don’t wait until they cause a complete breakdown.
INSTALLATION
Regulations
AMBIENT CABINETS – INSTALLATION
- Compliance with Local Requirements
- It is very important that your inline food cabinet is installed correctly and that the operation is correct before use. Installation must comply with local electrical, health & safety and hygiene requirements.
Setting Up
AMBIENT CABINETS – INSTALLATION
- Unpacking
- Unpack and check unit for damage and report any damage to the carrier and supplier. Report any deficiencies to your supplier.
- The display cabinet is supplied fully assembled, but the compressor unit and shelf trays are packed separately.
- Site Preparation
- Ensure the cabinet location and any bench cut outs are made to the precise measurements shown in the Mechanical Drawings. Position the cabinet in its allocated working position. Use a spirit level to ensure the cabinet is level from side to side and front to back.
- Cabinet Preparation
- Remove all protective plastic film, tapes, ties and packers, used to prevent movement during transit.
- Shelf Trays
- Remove the shelf trays from their packing, peel off any protective plastic coating and assemble them on the support members.
- Fit the correct size trays for each shelf level.
Grounding
-
* **WARNING:** THIS APPLIANCE MUST BE GROUNDED TO EARTH
- The grounding lead, in the mains cable, must always be connected to ground.
- A binding post is also provided adjacent to the control gear chassis, to allow the cabinet to be bonded to a surge grounding conductor or to adjacent equipment, should this be required.
- Power Supply
- Before connecting to the power supply, check that the local supply is correct to that shown on the rating plate, located on the rear of the cabinet.
- Isolation
- If the cabinet is not connected by a plug and socket, but is hard wired to the mains supply, a means of isolation must be provided.
- If a plug and socket are used, they should still be accessible after the cabinet is installed.
SERVICING
Control Gear
AMBIENT CABINETS – SERVICING
- Location
- The electrical control gear is located in the top of the cabinet.
- Remove the top plate to access the control gear.
- The chassis has power supplies for the lights, an extractor fan and a protective fuse.
Lighting
AMBIENT CABINETS – SERVICING
- Caution
- Do not service lights without isolating the cabinet from the mains supply.
- Shelf Lights
- Shelf lights are an optional extra, which can be fitted during manufacture.
- Test Lighting Components
- Before replacing an LED strip, check that the power supply is working.
- If there is no dc voltage at the output, the power supply should be replaced.
- If there is a dc output, the LED strip must be replaced.
- Access to LED Strips
- The LED strips are protected with plastic covers. These clip into grooves in the aluminium extrusion.
- Remove the plastic cover to access the LED strip.
- The top light assembly is different from the shelf lights, so the correct replacement unit must be used.
- LED Strip Replacement
- Individual LED modules cannot be replaced. A complete light unit must be used.
- The connection is made with a plug and socket. Disconnect the supply lead from the faulty unit, and reconnect it to the replacement unit.
Door Seals
AMBIENT CABINETS – SERVICING
- Seal Replacement
- The doors should be removed to allow the old seals to be removed and the new ones fitted. See the Cleaning section for details.
- Sliding Doors
SPECIFICATIONS
Mechanical
AMBIENT CABINETS – SPECIFICATIONS
| CABINET MODEL
---|---
IN 3A06S| IN 3A09S| IN 3A12S| IN 3A15S
Height (Counter Top)| 781 (+321) mm| 781 (+393) mm| 781 (+393) mm| 781 (+393)
mm
Height (In Counter)| 621 (+481) mm| 621 (+553) mm| 621 (+553) mm| 621 (+553)
mm
Height (Free Standing)| 1272 (-0+30) mm| 1272 (-0+30) mm| 1272 (-0+30) mm|
1272 (-0+30) mm
Width| 600 mm| 900 mm| 1200 mm| 1500 mm
Depth| 662 mm| 662 mm| 662 mm| 662 mm
Dry Weight| | | |
Cabinet Well Material| Stainless steel
Cabinet Colour| Grey and natural anodised aluminium.
Top Lighting| Standard
Shelf Lighting| Optional
Glass Type| Double glazed
Front Doors| Fixed glass or Sliding Doors
Number of Shelves| Two plus base
Display Area| 0.51 m2| 0.85 m2| 1.3 m2| 1.8 m2
Climatic Class & IP| Cabinets are tested under Climate Class 3 conditions and
have IP 20 ratings
Electrical
AMBIENT CABINETS – SPECIFICATIONS
| CABINET MODEL
---|---
IN 3A06S| IN 3A09S| IN 3A12S| IN 3A15S
Voltage| 220 – 240 V 50 Hz 1f
Power (with shelf lights)| 20 W| 31 W| 37 W| 55 W
Current (with shelf lights)| 0.08 A| 0.13 A| 0.16 A| 0.24 A
Connection| 3 pin plug, 10 A lead
Temperature Range| Ambient
Top Lights| 1 x LED strip| 1 x LED strip| 1 x LED strip| 1 x LED strip
Optional Shelf Lights| 2 x LED strips| 2 x LED strips| 2 x LED strips| 2 x LED
strips
Compliance
AMBIENT CABINETS – SPECIFICATIONS
- Standards
- FPG refrigerated, controlled ambient and ambient food display cabinets are designed to meet and exceed:
- International safety standards for electrical appliances: IEC 60335-1, IEC 60335-2-89, and the equivalent country-specific standards including AS/NZS, BS EN and UL 471.
- International standards for electromagnetic compatibility/emissions: CISPR 14-1, and the equivalent county-specific standards including AS/NZS CISPR and BS EN 55014-1.
- Essential safety requirements: AS/NZS 3820 and AS/NZS 4417
- Energy efficiency for refrigerated appliances: MEPS (Australia/New Zealand)
- Please contact FPG to discuss your requirements for meeting country-specific standards.
Improvements
- AMBIENT CABINETS – SPECIFICATIONS
- Ongoing Development
- FPG reserves the right to change specifications and construction, as part of ongoing product improvement.
ELECTRICAL CIRCUIT DIAGRAMS
- Model: IN 3A06-SQ
- Inline 3000 Square Series, 600mm Ambient Cabinet
- Model: IN 3A09-SQ
- Inline 3000 Square Series, 900mm Ambient Cabinet
- Model : IN 3A12-SQ
- Inline 3000 Square Series, 1200mm Ambient Cabinet
- Model: IN 3A15-SQ
- Inline 3000 Square Series, 1500mm Ambient Cabinet
SPARE PARTS
Cabinet Serial Number
When ordering spare parts, it is important to quote the Serial Number printed
on the label fixed to the control panel. This will enable FPG to trace details
of the build specification of your particular cabinet, and hence ensure that
spare parts are fully compatible.
To satisfy warranty conditions, and ensure optimum performance, use only FPG-
supplied spare parts.
Part Description | FPG Part No. |
---|---|
Main & Light Switch, EGO | 14372 |
Fuse Link (5A, 250V, Slow Blow) | 13330 |
Knob (light switch) | 14374 |
Ant-surge Thermistor 10 Ohm 3A | 22354 |
24V 60W LED power supply | 21613 |
36V 100W LED power supply | 25922 |
24V 12W Fan power supply | 25184 |
LED Driver 700mA | 25762 |
Polycarbonate Light Cover 1120mm | 18113 |
Polycarbonate Light Cover 720mm | 18114 |
Top Light Replacement Kit for 3A06 (Sliding Door / Fixed Front) | 69964 / 69862 |
Shelf Light Replacement Kit for 3A06 | 70321 |
Top Light Replacement Kit for 3A09 (Sliding Door / Fixed Front) | 70357 / 69861 |
Shelf Light Replacement Kit for 3A09 | 69402 |
Top Light Replacement Kit for 3A12 | 70378 |
Shelf Light Replacement Kit for 3A12 | 70380 |
Top Light Replacement Kit for 3A15 (Sliding Door / Fixed Front) | 70382 / 70381 |
Shelf Light Replacement Kit for 3A15 | 70383 |
Extraction Fan 24Vdc | 28390 |
- Location of Glass Parts
- In the following table, handed glass parts are labeled as viewed from the REAR of the cabinet.
Part Description | FPG Part No. |
---|---|
All glass parts are double glazed | |
LH Square DG End Glass Replacement Kit | 70367 |
RH Square DG End Glass Replacement Kit | 75992 |
600 Square DG Fixed Front Glass Replacement Kit | 75986 |
600 Square DG Top Glass Replacement Kit | 75941 |
Rear Inner Sliding Door (600) | 69165 |
Rear Outer Sliding Door (600) | 69166 |
Front Inner Sliding Door (600) | 69167 |
Front Outer Sliding Door (600) | 69168 |
900 Square DG Fixed Front Glass Replacement Kit | 75988 |
900 Square DG Top Glass Replacement Kit | 75983 |
Rear Inner Sliding Door (900) | 69407 |
Rear Outer Sliding Door (900) | 69408 |
Front Inner Sliding Door (900) | 69844 |
Front Outer Sliding Door (900) | 69032 |
1200 Square DG Fixed Front Glass Replacement Kit | 75989 |
1200 Square DG Top Glass Replacement Kit | 75984 |
Rear Inner Sliding Door (1200) | 69018 |
Rear Outer Sliding Door (1200) | 69019 |
Front Inner Sliding Door (1200) | 73488 |
Front Outer Sliding Door (1200) | 73489 |
1500 Square DG Fixed Front Glass Replacement Kit | 75990 |
1500 Square DG Top Glass Replacement Kit | 75985 |
Rear Inner Sliding Door (1500) | 73494 |
Rear Outer Sliding Door (1500) | 73495 |
Front Inner Sliding Door (1500) | 73492 |
Front Outer Sliding Door (1500) | 73493 |
Slide-in rubber door seal | 11424 |
Qlon door seal | 12922 |
Product Manual for Inline 3000 Square Series Ambient Cabinets | 26114 |
MECHANICAL DRAWINGS
Dimensions
AMBIENT CABINETS – MECHANICAL DRAWINGS
- Cabinet Variants
- Sliding doors can be fitted to the front and back of the cabinets.
- Fixed glass can be fitted in place of doors at the front
- IN-3A06/15-SQ Fixed Front In counter mounting
- IN-3A06/15-SQ Sliding Door In Counter mounting
- IN-3A06/15-SQ Fixed Front On counter mounting
- IN-3A06/15-SQ Sliding Door On counter mounting
- In line with our policy to continually develop, improve and support our products, Future Products Group Ltd reserves the right to change specifications and design without notice.
- Have a question? Please email us at support@fpgworld.com or visit WWW.FPGWORLD.COM for full contact details for your region.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>