nVent RAYCHEM S-20 Splice Kit Instruction Manual

June 10, 2024
nVent RAYCHEM

nVent RAYCHEM S-20 Splice Kit Instruction Manual
nVent RAYCHEM S-20 Splice Kit

Assembly Instructions

Assembly Instructions
Assembly Instructions
Assembly Instructions

*BTV/QTVR (Hazardous area)**

| ATEX / UKEX| IECEx
---|---|---
BTV| SGS20ATEX0048X / BAS21UKEX0497X| IECEx BAS.06.0043X
II 2 G Ex 60079-30-1 eb IIC T6 Gb| Ex 60079-30-1 eb IIC T6 Gb
II 2 D Ex 60079-30-1 tb IIIC T80°C D| Ex 60079-30-1 tb IIIC T80°C Db
II 2 G Ex 60079-30-1 eb mb IIC T6 Gb| Ex 60079-30-1 eb mb IIC T6 Gb
II 2 D Ex 60079-30-1 mb tb IIIC T80°C Db| Ex 60079-30-1 mb tb IIIC T80°C Db
Tmin –60°C| Tmin –60°C
QTVR| SGS20ATEX0050X / BAS21UKEX0498X| IECEx BAS.06.0045X
II 2 G Ex 60079-30-1 eb IIC T4 Gb| Ex 60079-30-1 eb IIC T4 Gb
II 2 D Ex 60079-30-1 tb IIIC T130°C Db| Ex 60079-30-1 tb IIIC T130°C Db
II 2 G Ex 60079-30-1 eb mb IIC T4 Gb| Ex 60079-30-1 eb mb IIC T4 Gb
II 2 D Ex 60079-30-1 mb tb IIIC T130°C Db| Ex 60079-30-1 mb tb IIIC T130°C Db
Tmin –60°C| Tmin –60°C
| BE.8.B.01728/21
1 Ex e IIC T Gb X Ex tb IIIC T Db X
TЕМП ОКР СРЕДЫ –60 to +56°C

North America

BTV

| Class/division when| Zone when installed with S-20
---|---|---
installed with S-20|
cCSAus Certificate 1333271| cCSAus Certificate 1333271
Class I Division 2 Group| US: Class I Zone 1 AEx eb IIC T6
A,B,C,D| Gb Zone 21 AEx tb IIIC T85°C Db
Class II Division 2 Group| Canada: Ex 60079-30-1 IIC
E, F,G| T6 Gb
Class III T6| Ex 60079-30-1 IIIC T85°C Db

QTVR

| cCSAus Certificate 1333271| cCSAus Certificate 1333271
Class I Division 2 Group| US: Class I Zone 1 AEx eb IIC
A,B,C,D| T4 Gb Zone 21 AEx tb IIIC
| T135°C Db
Class II Division 2 Group| Canada: Ex 60079-30-1 IIC
E, F,G| T4 Gb
Class III T4| Ex 60079-30-1 IIIC T135°C Db
Um= 277 V max.|

Hazardous area

WARNING: Please make sure the installation is carried out in clean, dry conditions and all cable ends are protected from moisture. Follow instructions carefully.

WARNING: The purchaser should make the manufacturer aware of any external effects or aggressive substances that the equipment may be exposed to.

Specific conditions of use

Maximum exposure temperature: 110°C (230ºF)
Minimum exposure temperature: –60°C (–76ºF)
Minimum installation temperature: –20°C (–4ºF)
Maximum current: 35A (QTVR)

For use with the heating cable types as shown in the table

  • Refer to installation manual. A ground fault circuit interrupter shall be used with this device.
  • Earth fault equipment protection is required for each circuit.
  • De-energise circuits before installation or servicing.
  • Keep ends of heating cables and kit components dry before and during installation.
  • The electrically conductive covering of this heating cable shall be connected to a suitable earthing terminal.
  • The presence of the heating cables shall be made evident by the posting of caution signs or markings at appropriate locations and/or at frequent intervals along the circuit.
  • The insulation resistance of the heating cable shall be measured and recorded after installation and shall not less than 20Mohm.
  • Persons involved in the installation and testing of electric trace heating systems shall be suitably trained in all special techniques required.
  • Installation shall be carried out under the supervision of a qualified person.

Assembly Instructions
Assembly Instructions
Assembly Instructions
Assembly Instructions
Assembly Instructions
Assembly Instructions
Assembly Instructions
Assembly Instructions
Assembly Instructions
Assembly Instructions
Assembly Instructions
Assembly Instructions
Assembly Instructions
Assembly Instructions
Assembly Instructions
Assembly Instructions
Assembly Instructions
Assembly Instructions
Assembly Instructions
Assembly Instructions
Assembly Instructions
Assembly Instructions
Assembly Instructions
Assembly Instructions
Assembly Instructions
Assembly Instructions
Assembly Instructions
Assembly Instructions
Assembly Instructions
Assembly Instructions
Assembly Instructions

België/Belgique
Tel +32 16 21 35 02
Fax +32 16 21 36 04
salesbelux@nVent.com

Bulgaria
Tel +359 5686 6886
Fax +359 5686 6886
salesee@nVent.com

Česká Republika
Tel 420 602 232 969
czechinfo@nVent.com

Denmark
Tel +45 70 11 04 00
salesdk@nVent.com

Deutschland
Tel 0800 1818205
Fax 0800 1818204
salesde@nVent.com

España
Tel +34 911 59 30 60
Fax +34 900 98 32 64
ntm-sales-es@nVent.com

France
Tél 0800 906045
Fax 0800 906003
salesfr@nVent.com

Hrvatska
Tel +385 1 605 01 88
Fax +385 1 605 01 88
salesee@nVent.com

Italia
Tel +39 02 577 61 51
Fax +39 02 577 61 55 28
salesit@nVent.com

Lietuva/Latvija/Eesti
Tel +370 5 2136633
Fax +370 5 2330084
info.baltic@nVent.com

Magyarország
Tel +36 1 253 7617
Fax +36 1 253 7618
saleshu@nVent.com

Nederland
Tel 0800 0224978
Fax 0800 0224993
salesnl@nVent.com

Norge
Tel +47 66 81 79 90
salesno@nVent.com

Österreich
Tel 0800 29 74 10
Fax 0800 29 74 09
salesat@nVent.com

Polska
Tel +48 22 331 29 50
Fax +48 22 331 29 51
salespl@nVent.com

Republic of Kazakhstan
Tel +7 7122 32 09 68
Fax +7 7122 32 55 54
saleskz@nVent.com

Россия
Тел +7 495 926 18 85
Факс +7 495 926 18 86
salesru@nVent.com

Serbia and Montenegro
Tel +381 230 401 770
Fax +381 230 401 770
salesee@nVent.com

Schweiz/Suisse
Tel. 41 (41) 766 30 80
Fax 41 (41) 766 30 81
infoBaar@nVent.com

Suomi
Puh. 0800 11 67 99
salesfi@nVent.com

Sverige
Tel +46 31 335 58 00
salesse@nVent.com

Türkiye
Tel +90 560 977 6467
Fax +32 16 21 36 04
salesee@nVent.com

United Kingdom
Tel 0800 969 013
Fax 0800 968 624
salesthermalUK@nVent.com

©2022 nVent. All nVent marks and logos are owned or licensed by nVent Services GmbH or its affiliates. All other trademarks are the property of their respective owners. nVent reserves the right to change specifications without notice. RAYCHEM-IM-EU1600-S20-ML-2205

nVent.com/RAYCHEM

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

nVent RAYCHEM User Manuals

Related Manuals