Schneider Electric LC2D A Series TeSys Deca Reversing Contactor Instruction Manual

June 10, 2024
Schneider Electric

schneider electric logoElectric LC2D A Series TeSys Deca Reversing Contactor
Instruction Manual
LC1DppApp / LC1DppA3pp / T02DN13pp
LC2DppApp / LC2DppA3pp / T02DN23pp

LC2D A Series TeSys Deca Reversing Contactor

Schneider Electric LC2D A Series TeSys Deca Reversing Contactor - assembly
1

DANGER
HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH
Disconnect all power before servicing equipment.
Failure to follow these instructions will result in death or serious injury.Schneider Electric LC2D A Series TeSys Deca Reversing Contactor -
assembly 2Schneider Electric LC2D A Series TeSys Deca Reversing
Contactor - assembly 3Schneider Electric LC2D A Series TeSys Deca Reversing
Contactor - assembly 4Schneider Electric LC2D A Series TeSys Deca Reversing
Contactor - assembly 5

WARNING
HAZARD OF FIRE OR ELECTRIC SHOCK
On contactors connected to a feeder circuit, it is mandatory to install large spacing adapters GV3G66 on top and bottom connections of the contactor to respect UL and  CSA requirements in North America.
Failure to follow these instructions can result in death, serious injury, or equipment damage.Schneider Electric LC2D A Series TeSys Deca Reversing
Contactor - assembly 7Schneider Electric LC2D A Series TeSys Deca Reversing
Contactor - assembly 8

AC/DC:

  • use of this product in EMC environment B may require mitigation measures to avoid unwanted disturbance.
  • full open AC at 10%Us.

WARNING

HAZARD OF FIRE OR ELECTRIC SHOCK (FOR CONTACTOR WITH UL HI-FAULT SHORT CIRCUIT CURRENT RATINGS ONLY)

  • The opening of the branch-circuit protective device may be an indication that a fault current has been interrupted.
  • To reduce the hazard of fire or electric shock, current-carrying parts and the other components of the controller should be examined and replaced if damaged.
    Failure to follow these instructions can result in death, serious injury, or equipment damage.

Additional
ratings| Lighting
Tungsten| Lighting
Ballast| DefLill e Purpose ratings, 3Phase,
Load wiring: breaking all lines| Elevator Duty HP ratings
(except .D and .W DC coil)| High-Fault SCCR
Class J Fuse| High-Fault SCCR
with CB
---|---|---|---|---|---|---
Device| 600 V| 600 V| FLA| LRA| 1Ph
120 V| 1Ph
240 V| 3Ph
200 V| 3Ph
230 V| 3Ph
480 V| 3Ph
600 V| 600 V| 480 V| 600 V
240 V| 480 V| 600 V
LC1D40A| 60 A| 60 A| 40 A| 240 A| 200 A| 160 A| –| 5hp| 10hp| 10hp| –| –| 100 kA| 100 kA| 50 kA
LC1D50A| 70 A| 70 A| 50 A| 300 A| 250 A| 200 A| 3hp’| 7.5hp| 15hp| 15hp| 25hp| 30hp| 100 kA| 100 kA| 50 kA
LC1D5OANR,| –| –| –| –| –| –| –| –| –| –| –| –| 100 kA| 100 kA| 50 kA
LC1D65A/80A| 70 A| 80 A| | 390 A| 325 A| 208 A| 3hr| 10hp| 15hp| 20hp’| 25hp| 30hp| 100 kA| 100 1(A| 50 kA

Refer to information on device label when ordering replacement parts.

The product’s manufacture date is coded PPYYWWD, where:

  • PP: plant code
  • YY: year of manufacture
  • WW: week of manufacture
  • (D: weekday of manufacture (Monday = 1))

LC1D A6

Schneider Electric LC2D A Series TeSys Deca Reversing Contactor - assembly
9

DANGER
HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH
Disconnect all power before servicing equipment.
Failure to follow these instructions will result in death or serious injury.

Schneider Electric LC2D A Series TeSys Deca Reversing Contactor - assembly
10Schneider Electric
LC2D A Series TeSys Deca Reversing Contactor - assembly
11Schneider Electric
LC2D A Series TeSys Deca Reversing Contactor - assembly