Enerdrive EPC2000 Epro Combi Inverter Charger Instruction Manual
- June 9, 2024
- Enerdrive
Table of Contents
DC to AC true sinewave inverter programmable
automatic battery charger automatic transfer switch Installation Guide and
Safety Information
EPC 2000-12 to EPC 3500-24
EPC2000 Epro Combi Inverter Charger
- Please read this document very carefully to avoid product malfunction, shock and/or fire hazards!
- This document provides a brief overview of a stand alone product installation. For long term safe and trouble free operation, it is very important to read the enclosed owner’s manual as well!
Safety Information:
Please read this document very carefully to avoid equipment malfunction, shock
and/or fire hazards!
WARNING
-
To reduce the risk of electrical shock, do not expose to rain, snow, spray, moisture, excessive pollution and condensing circumstances. To reduce the risk of fire hazards, do not cover or obstruct the ventilation openings or expose the charger to dusty environments. Install only in a well ventilated room.
-
The installation of must be performed by qualified personnel and in accordance with local electrical regulations. Make sure to correctly size AC and DC wiring, in order to withstand the maximum currents that could flow through these wires. Take care of a solid installation of all wiring and anchor wiring were possible to add a degree of strain relieve. Never operate when the wiring is undersized or damaged.
-
Except for the connection compartment, this product may never be opened or disassembled by anyone other than authorized and trained personnel. There are no user serviceable parts inside .
-
To reduce the risk of electrical shock, disconnect from all AC and DC lines and wait for at least 1 minute, before performing any maintenance, removing the connection compartment cover, storing or transporting of. Switching the power switch of to the off (O) position, will not be sufficient to reduce the risk of electrical shock since the internal circuits remain energized.
-
To reduce the risk of electrical shock, must be provided with a permanent safety earth ground connection to the AC input ground terminal, and/or the external grounding point at the bottom of . Never operate when the AC input ground terminal is not connected or when there is a chance that the grounding connection might be impaired.
-
To reduce the risk of electrical shock, a Ground Fault Circuit Interruptor (GFCI) must always be installed in the AC supply circuit. Make sure can be disconnected from the AC supply circuit by installing an appropriate double pole AC switch.
-
To reduce the risk of explosion, never use in locations where there is danger of gas- or dust explosions or where ignition protected equipment is mandatory. Never install directly on top of the battery or vice-versa.
-
Working in the vicinity of lead-acid batteries is dangerous. Batteries generate explosive gases during normal operation. Therefore, it is of utmost importance that each time before servicing in the vicinity of the battery, that you read all enclosed manuals and follow the instructions exactly.
CAUTION -
Always disconnect the AC supply before making or breaking the connections to the battery.
-
This product is intended for charging LEAD-ACID batteries (flooded, GEL, AGM and any other lead acid derivatives) and to supply consumers that are attached to these batteries in fixed installations. This product is capable to charge Lithium based batteries as well. Please contact Enerdrive for more information. Do not attempt to charge batteries based on other chemistries or non rechargeable batteries with this charger. This may result in bursting batteries and can cause personal injuries and other damage.
-
Always install a correctly sized external DC fuse or circuit breaker as close as possible to the battery terminals.
-
To reduce the risk of battery explosion, follow these instructions and those published by the battery manufacturer and the manufacturer of any unit you intend to use in the vicinity of the battery. Review cautionary markings on these products.
-
The use of any attachments or spare parts not recommended or sold by Enerdrive, may result in risk of fire, electric shock or injury to persons.
-
If this product is protected against reverse polarity by an internal fuse. This fuse can only be replaced by authorized personnel.
WARNING: GENERAL BATTERY PRE-CAUTIONS
- Have someone within range of your voice or close enough to come to your aid when you work near a lead-acid battery.
- Have plenty of fresh water and soap nearby in case battery acid contacts skin, clothing, or eyes.
- Wear proper, non-absorbent gloves, complete eye protection, and clothing protection. Avoid touching your eyes and wiping your forehead while working near batteries.
- If battery acid contacts skin or clothing, wash immediately with soap and water. If acid enters your eye, immediately flood it with running cold water for at least 15 minutes and get medical attention immediately.
- Never smoke or allow a spark or flame near batteries.
- Use extra caution to reduce the risk of dropping a metal tool on the battery. It could spark or short circuit the battery or other electrical parts and could cause an explosion.
- Remove all personal metal items, like rings, bracelets, and watches when working with batteries. Batteries can produce a short circuit current high enough to weld metal to skin, causing a severe burn.
- If you need to remove a battery, always remove the ground terminal from the battery first. Make sure all accessories are off so you don’t cause an arc.
- Never charge a frozen battery.
- Make sure the area around the battery is well ventilated while charging. Make sure the voltage of the battery matches the output voltage of the battery charger. Study all battery manufacturer’s recommendations for further specific precautions such as whether equalization is acceptable for your battery or not, and recommended rates of charge.
UNPACKING
The package should contain the following items :
-
ePRO Combi Inverter Charger
-
Wall bracket
-
Temperature sensor (3m)
-
This Installation Guide and
Safety Information -
Owner’s manual
-
Charger warning stickers
-
2 x M10 crimp terminals
-
7 x Mounting screws
CAUTION
After unpacking, check if the product shows any mechanical damage. Never use
the product when the enclosure shows any visual damage caused by harsh
handling, or when it has been dropped accidentally. Contact your local
supplier for further information.
MOUNTING
The schematic on the right shows a typical standalone installation. No
guarantees are given on the compliance of any local electrical regulations.
Please make sure that the complete installation is made in accordance to all
locally applicable electrical regulations.
This Class I product must be earthed! Always connect the PE wire or chassis
ground screw between the fans to your central ground (vehicle chassis,
grounding system of your boat etc.)
This product is equipped with a ground relay that automatically connects the
output Neutral to the chassis (PE) in inverter mode (AC transfer switch is
open). When AC is present at the input, the ground relay will open just before
the AC transfer switch closes. This behaviour enables correct operation of an
earth leakage circuit breaker (GFCI/RCD) that is connected to the output.
To reduce the risk of explosion, never use this product in locations where
there is danger of gas- or dust explosions or where ignition protected
equipment is mandatory. Never install the charger directly on top of the
battery or vice-versa.
Always connect the negative (-) cable directly on the negative terminal of the
battery, or on the “load side” of a current shunt. Always keep positive and
negative cables close to each other to minimize electromagnetic fields. Double
check for correct polarity, before connecting the battery cables to the
battery!
Heavy load hazard. Take care when lifting the unit by yourself. The use of two
people to lift and mount the unit is preferred. Make sure that the wall can
easily support a load of 20 kilos. Use appropriately sized screws. Mount the
inverter/charger before connecting any wires or cables.
WIRING DETAILS
Notes:
- Please consult the following table to determine the correct battery cable size for each model. The given cable sizes are valid for cables installed in free air. Using a smaller cable size or a longer cable may cause the inverter to shutdown under heavy load. Fire and burning hazards are present if the battery cables are insu!ciently sized for the expected current. Battery cable lengths longer than 3 meters, are not recommended.
- The AC input must be protected by a fuse or magnetic circuit breaker (MCB) rated at 30A or less and wiring must be sized accordingly (the* local regulations). If the A( input supply is rated at a lower value. the fuse or 1/4B should be down sized accordingly.
- An earth leakage circuit breaker with over current protection (RCBO) rated to support the expected load, must be included in series with the AC output The AC output wiring must be sized accordingly. Please take into account that with the AC Power Boost feature enabled, the ePRO Combi can add roughly 12A to the output during periods of peak power demand. Assuming a maximum transfer switch utilization, the total output current can reach a level of 30A + 12A = 42A. Therefore the maximum RCBO rating is 40A.
- Programmade relay 1 is configured standard as an alarm relay. This means that it will be activated once the ePRO Combi shuts down and jumps to an error mode. Relay 2 will be activated only a few minutes after the AC supply has become available. In case of battery operation, Relay 2 will deactivate immediately. This can be used to switch less alma I AC loads (i.e. electric boiler, aircon) on and off that are allowed to be supplied by the mains or generator only. Always include a 16A fuse in senes with the programmable relay contacts.
- The requited contact specifications for the trigger switches are 5V/5mA. The required contact specifications for the remote switch are 60V/10rnA. The maximum wire length between the switch and the ePRO Combi is 30nt The remote switch will only operate when the main on/olt switch is either in position I or
- The battery temperature sensor must be attached to the main battery. An optional remote control will only operate when the main on/off switch is either in position I or II. In this case the power switch on the remote control panel will be used to turn the ePRO Combi on and off.
- The secondary charger output is limited to approximately 4A and has a slightly lower output voltage compared to the main battery connection. This output is intended to maintain the capacity of a starter battery and is diode isolated from the main connection. A battery fuse of WA should be installed in this line. A wire size of at least 2.5mm’ should be used for this output