Product Specifications

Model No.| HV1842T| HV1842RGBW
Name| Split
Material| 316 Stainless Steel
Colour| Stainless Steel
IP Rating| IP67
Input Voltage| 12v DC
Protection Class| % (Low Voltage)
Lamp Base| Built-In LED
Lamp Wattage| I x 5w
Colour Temp| TRI Colour – 3000k, 4000k, 5500k| RGBW (RGB + 3000K)
Lumens| 4001m, 430lm, 4501m| 1951m (3000k)
CRI| > 80
Wiring| Parallel
Dimmable| No| Yes with RGBW Controller
Warranty| 3 Years Replacement*

Dimensions

HAVIT Lighting HV1842T Split Inground Light

Adequate Drainage

HAVIT Lighting HV1842T Split Inground Light - fig 1

Important Safety Issues:

  • This product must be installed by a qualified electrician according to AS/NZS 3000.
  • Ensure all electrical mains are disconnected before any installation.
  • Modification of this product will void any warranty.
  • Havit Lighting does not take responsibility for wrong installation, incorrect use, or use of installation material that does not belong to the system.
  • When installing low voltage fittings, the Voltage to fitting must be within +or- 5% of the voltage required, if not within this allowance warranty will be voided.
  • Aluminum and 304SS fittings must not be installed within 5km of any saltwater environments.
  • All 316 stainless steel fittings must have regular cleaning maintenance to avoid any tea staining from forming on the fitting. (Warranty does not cover Tea Staining)
  • All o-rings and seals must be in place correctly to maintain a warranty
  • When installing inground light fittings, Adequate drainage must be allowed to prevent fittings from sitting in water for a long period of time, if no drainage is allowed, the Warranty will be voided, See sample adequate drainage diagram for correct installation method.
  • This form may be updated at any time due to product improvements, please check the online installation form for the most current version.

Steps for Installation: HV1842T

  1. Make sure that the electrical circuit is free of voltage (master switch off)
  2. Make a hole where the fitting is to be placed using dimensions provided on line drawings, making sure adequate drainage is allowed.
  3. Insert the canister, and ensure that the top is level with the ground or floor. Failure to do so will void the warranty.
  4. Using an appropriate I 2v DC LED Driver – DO NOT CONNECT LIGHT FITTING DIRECTLY TO 240V
  5. Connect the cable – If more than one fitting is installed, wiring must be done in parallel.
  6. Strip back the cable on both fitting and cable run and twist the positive cables together. Then connect neutral cables together
  7. Solder all joins using solder and either a heat gun or butane gas torch.
  8. Cover connections using an adhesive-lined heat shrink or gel cap to make the connection watertight. Failure to do this will void the warranty.
  9. Heat the heat shrink or crimp the gel cap making sure all connections are covered.
  10. Make sure the seals are still in place and screws are tight to avoid any water penetration.
  11. Fitting is preset to 3000k, locate cap on the bottom of fitting and remove by twisting anti-clockwise, Slide switch to desired color temperature, and Reattach cap making sure it is tight. 1
  12. Insert fitting into the canister.
  13. Apply silicon around the edge of the fitting to prevent any water from getting inside to electrical connections.
  14. All connections must be carried out carefully, inspect all contacts before switching back on the electric circuit.

Steps for Installation: HV1842RGBW

  1. Make sure that the electrical circuit is free of voltage (master switch off)

  2. Make a hole where the fitting is to be placed using dimensions provided on line drawings, making sure adequate drainage is allowed.

  3. Insert the canister, and ensure that the top is level with the ground or floor. Failure to do so will void the warranty.

  4. Connect the cable –

  5. Use an appropriate 12v DC LED Driver and RGBW LED Controller- DO NOT CONNECT LIGHT FITTING DIRECT TO 240V

  6. Do this by stripping back the cable on both fitting and cable run and twisting the cable together making sure all colors are correctly joined to the correct colour-
    • Black= Positive
    • Red = Red
    • Green = Green
    • Blue = Blue
    • White = White

  7. Solder all joins using solder and either a heat gun or butane gas torch.

  8. Cover connections using an adhesive-lined heat shrink or gel cap to make the connection watertight. Failure to do this will void the warranty.

  9. Heat the heat shrink or crimp the gel cap making sure all connections are covered.

  10. Connect cable run to RGBW Controller.

  11. Connect the RGBW Controller to a 12v DC LED Driver.

  12. Apply silicon around the edge of the fitting to prevent any water from getting inside to electrical connections.

  13. All connections must be carried out carefully, inspect all contacts before switching back on the electric circuit.

Steps for Installation: HV1842-F-SH

  1. Remove nuts on the back of the fitting and set aside
  2. Remove cover and replace with security face
  3. Reattach nuts and tighten making sure seals are still in place
  4. Insert fitting into the canister
  5. Insert screws and tighten

Must be installed by a licensed electrician

Contact  Details:
143 Beauchamp Road
Matraville NSW 2036
Australia
Tel: 02 9381 8300
Fax: 02 9666 8881
Email: sales@havit.com.au
Web: www.havit.com.au

**Warranty Terms & Conditions*** ****
![HAVIT Lighting HV1842T Split Inground Light -

additional](https://manuals.plus/wp-content/uploads/2022/08/HAVIT-Lighting- HV1842T-Split-Inground-Light-additional.jpg)
https://havit.com.au/pages/warranty-terms-and-conditions| https://havit.com.au/

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Havit Lighting User Manuals

Related Manuals