INTRODUCTION

The H12VSENSORPIR is a motion sensor that dims lighting from high to low based on movement. This slim, low-profile sensor is designed for installation inside the bottom of a light fixture body. The sensors use infrared sensing technology that reacts to changes in movement within the coverage area. Once the sensor stops detecting movement and the time delay elapses lights will go rom high to low mode and eventually to an OFF position if it is desired. Sensors must directly “see” motion of a person ormoving object to detect them, so careful consideration must be given to sensor luminaire placement and lens selection. Avoid placing the sensor where obstructions may block the sensor’s line of sight.

SPECIFICATIONS

  • Power supply: 12V-24V DC, >30mA
  • Dim control output: 0-10V, max. 25mA sinking current
  • Remote range: 50ft. (15m) indoor, no backlight
  • Dim control output_: 0-10V
  • Detection radius: 20%/50%/75%/100%(1-8m)
  • Mounting height: Max 40ft.(12meters)
  • Time setting: 10s/1min/5min/10min/15min/20min/30min/60min
  • Light-control: 24H/10LUX/30LUX/50LUX
  • Temperature: -4°F +140°F (-20°C +60°C)
  • IP rating: IP65

WARNING

NOTE: Warm up time is 40 seconds. After initial connection the fixture will stay on for 40 seconds and then transition to normal operation mode.
NOTE: Factory default settings: Sensitivity: 100%; Hold time: 5min; Daylight sensor: On; Dimming level: 306; Dimming time: 60 min.
NOTE: If any settings are change by the remote control, the LED indicator on the sensor will flash as confirmation.

Function Description

The sensor allows for an intermediate dimmed level before full switch off. This function is also determined by available ambient light. Adjustable settings include High end brightness trim, Detection sensitivity, Hold time, Stand-by time, Stand- by dimming level, and Daylight sensor setting

NICOR H12VSENSORPIR Low Voltage Passive Infrared Sensor
3

Daylight Sensor Function

To enable the daylight sensor press on the remote control

NICOR H12VSENSORPIR Low Voltage Passive Infrared Sensor
4

Settings on this demonstration:

  • Hold-time: 30min
  • Setpoint on: 50lux
  • Setpoint off: 300lux
  • Stand-by Dim: 10%
  • Stand-by period: +o

(when the daylight sensor is enabled, the stand-by time locks at +o)

Power on

NICOR H12VSENSORPIR Low Voltage Passive Infrared Sensor
5

SENSOR COVERAGE

NICOR H12VSENSORPIR Low Voltage Passive Infrared Sensor
6

INSTALLATION INSTRUCTIONS

Low voltage passive infrared sensor

  • MODEL: H12VSENSORPIR

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

NICOR User Manuals

Related Manuals