A D WeiV Communication Application for Balances/Scales Using Bluetooth Installation Guide
- June 9, 2024
- A D
Table of Contents
- A D WeiV Communication Application for Balances/Scales Using Bluetooth
- About This Manual
- License Agreement
- Software Download
- About the Application
- Features
- Supported OS/Supported Models
- How to Use
- Details of the Screen
- INSTRUCTION
- The Scan Screen
- How to Operate
- Advanced Functions
- Automatic Recover after Disconnection
- Troubleshooting
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
A D WeiV Communication Application for Balances/Scales Using Bluetooth
About This Manual
- No parts of this manual may be reprinted, copied, modified, or translated without the written permission of A&D Company, Limited.
- The contents of this manual are subject to change without notice.
- Please contact A&D if you notice any uncertainty, errors, omissions, etc. in this manual.
License Agreement
- Copyrights for “A&D WeiV” are owned by A&D Company, Ltd.
- Reproduction of “A&D WeiV” without prior written consent from A&D is prohibited.
- “A&D WeiV” specifications and this manual are subject to change without notice.
- “A&D WeiV” is intended for the transmission of data from an A&D counting scale to a smartphone or tablet. Do not use it for any other purpose.
- A&D Company, Ltd. bears no liability for direct, indirect, special, or consequential damages resulting from any defect in the “A&D WeiV” program or this manual, even if advised of the possibility of such damage. Furthermore, A&D assumes no liability for claims of rights from third parties. Concurrently, A&D assumes no liability whatsoever for software or data losses.
- The Bluetooth® word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by A&D is under license.
- iOS is an operating system name of Apple Inc., and it is a trademark or registered trademark of Cisco in the U.S. and other countries and is used under license.
- Apple, the Apple logo are trademarks of Apple Inc., registered in the U.S. and other countries.
- App Store is a service mark of Apple Inc., registered in the U.S. and other countries.
- Android™, Google Play and the Google Play logo are trademarks of Google LLC., registered in the U.S. and other countries.
Software Download
A&D WeiV can be downloaded from the App Store or Google Play.
- App Store: https://apps.apple.com/app/a-d-weiv/id6443930190
- Google Play: https://play.google.com/store/apps/details?id=jp.co.aandd.balanceapp&hl=en
About the Application
This application, A&D WeiV, enables wireless connection (using Bluetooth) between electric balances or scales (hereinafter referred to as “weighing devices”) manufactured by A&D and tablets or smartphones (hereinafter referred to as “terminals”), and it receives and saves data (hereinafter referred to as “weighing data”) received from weighing devices.
Features
- Enables terminals to receive weighing data or Good Laboratory Practice (GLP) / Good Manufacturing Practice (GMP) compliant reports.
- Sends commands to weighing devices and controls them.
- Has a repeat function that sends commands per specified time.
- Outputs weighing data after adding date, time, or number.
- Shares weighing data with other applications and saves in an appropriate format.
Supported OS/Supported Models
- Supported OS
- Android 9.0 or later
- iOS 14.0 or later
- Supported models (as of January 2023)
Models with which the Bluetooth communication interface option OP-27 (hereinafter referred to as “the option”) is usable.
Models | Necessary options |
---|---|
FZ-i/FX-i series |
GXA-27
FZ-iWP/FX-iWP series
GX-A/GF-A series
GX-AWP/GF-AWP series
HR-AZ/HR-A series
GX-M/GF-M series
FG-CWP series| FG-27CWP
HV-C/CP, HW-C/CP series| HVW-27C
HV-CWP/HW-CWP series| HVW-27CWP
SC/SE series| SCE-27
Models with built-in Bluetooth
Models | Necessary options |
---|---|
BA-T series |
None (Usable without options)
SH-AWP-BT/SJ-AWP-BT series
Bluetooth converter AD-8529PC-W is not usable with A &D WeiV.
How to Use
When Using the Bluetooth Communication Interface Option
Setting up the DIP switches
Set up the DIP switches on the option board to enable bidirectional
communication. For the details, refer to the instruction manual of each option
board.
- Disconnect the AC adapter or remove batteries from the weighing device.
- Following the steps indicated in the instruction manual of the option board, remove the board from the weighing device.
- Turn off the DIP switches (to enable bidirectional communication).
- Attach the option board to the weighing device again, as indicated in the instruction manual of the option board.
- Connect the AC adapter to or put in the batteries in the weighing device.
When Using on Models with Built-In Bluetooth
Setting the Weighing Device (for the BA-T Series)
- Activate the weighing device and select the menu for setting Bluetooth by pressing the MENU key.
- Set the Bluetooth mode to Bluetooth serial, and the Data format to A&D standard format.
| Name| Preset value (setting range)
---|---|---
(1)| Bluetooth mode| Bluetooth keyboard,| Bluetooth seriall|
(2)| Connection status| -
(3)
|
Bluetooth data format
| A&D standard format , DP format, KF format, MT format,
NU format, NU2 format,
CSV format,
Setting the Weighing Device (for the SH-AWP-BT/SJ-AWP-BT Series)
Bluetooth is automatically set when the weighing device is activated.
Connecting a Terminal to the Weighing Device
- Make sure that the Bluetooth function on the terminal is on.
- Turn on the power of the weighing device. With a weighing value being shown, tap the icon for A&D WeiV installed on the terminal and activate the application. After it is activated, it shows a list of connectable weighing devices on the Scan screen.
- Select and tap the weighing device to be connected.
- If the appropriate weighing device is not shown, swipe down the screen to re-scan.
- The terminal asks for pairing. Tap OK.
Depending on the manufacturing date of models and option boards, a number other than the serial number of the weighing device may be shown.
- If the terminal is already paired with the weighing device, unpair (delete the device) on the setting screen of the terminal.
- If the problem persists, turn on the power of the weighing device again. For details of other cases and actions to take, refer to “5. Troubleshooting”.
Details of the Screen
The Main Screen
- Weighing result
- Go to the Scan screen
- Model name/serial number
- Entry field for commands
- Send a command
- Repeat function
- Add time/date/number
- RE-ZERO, TARE
- Logging data
- Clear/share weighing data
INSTRUCTION
- Weighing result Displays the weighing result received in the A&D standard format. The weighing result is not displayed if it is in other than the A&D standard format. (Weighing data in (9) is displayed.)
- Go to the Scan screen Tapping this disconnects the connection to the weighing device, and returns to the Scan screen.
- Model name/serial number Displays the model name and serial number of the weighing device that is connected. Model names or serial numbers are not displayed when the HV-27C, HV-27CWP, or SHAWP- BT/SJ-AWP-BT series are connected.
- Entry field for commands Shows the Q command by default. As soon as a command is sent, weighing data is output. When the entry field is tapped, the keyboard appears and you can change the command. For available commands, refer to the instruction manual of the weighing device to be used.
- Send a command When Command is tapped, the command entered is sent.
- Repeat function When this function is enabled, the command entered in (4) is repeated at a designated interval (seconds). 1 sec is displayed as a default. Tap the number to change it. (999 sec at a maximum, every 1 second) As a guide, keep the total number of data to 3000 at a maximum. Otherwise, the Share may not function.
- Add time/date/number Adds time, date, or number to weighing data. When data to be added is tapped, it is added. Time, date, and number are also added to weighing data that is retrieved before it is tapped.
- RE-ZERO, TARE The display of the weighing device shows 0 when these are tapped, and (1) in the main screen is cleared. The Z command is sent when RE-ZERO is tapped. The T command is sent to the weighing device when TARE is tapped. TARE does not operate with models that have no tare key The weighing result is displayed again when the Q command is tapped with the Command
- Logging data Logs and displays weighing data. When time, date, or number is added, the items selected in (6) are displayed separated with commas after weighing data. You can see weighing data that is not shown in the screen by scrolling down. Model name is displayed in the first line and serial number in the second when the screen is shifted from the Scan screen to the main screen (they are not displayed on some models).
- Clear or share the weighing data The following message appears when Clear is tapped.
- Weighing data in (9) is cleared if OK is tapped.
- Weighing data in (9) is not cleared if Cancel is tapped, and the main screen is shown again.
By tapping Share, you can share weighing data in (9) with another application and save it.
The Scan Screen
If Bluetooth communication cannot be detected after the Scan screen is displayed, the screen does not change to the main screen even if the weighing device is tapped.
How to Operate
Basic Operation
This section describes how to log the weighing data on the main screen after the weighing device is connected.
The weighing device should show the weighing result (weight should be displayed).
- With nothing placed on the weighing device, tap RE-ZERO. The weighing device shows 0.00 g (the number of digits shown varies depending on the model).
- When using tare, place a tare weight and tap TARE. The weighing device shows 0.00 g (the number of digits shown varies depending on the model).
- Place objects on the weighing device, and then tap Command with Q shown in the Command Data. A value is displayed and recorded in the weighing result in (1) and logging data in (9).
- Repeat step 3 above.
- Once weighing is complete, tap Share.
- From the list of application that appears, tap and open an application such as Mail or Notes. The contents of the weighing data are shown in the application.
- You can mail or save the data with the application.
- Exit the application, and return to the main screen of A&D WeiV.
- To delete the weighing data, tap Clear and then tap OK in the message screen that appears.
- To exit the screen, disconnect the communication with the weighing device by tapping Scan to return to the Scan screen. Then, exit A&D WeiV.
Advanced Functions
Adding Time/Date/Number
To add time, date, or number to weighing data, tap among Time, Date, or No. shown in Data. The item for the button tapped is added to weighing data. It can be used in step 3 to step 4 in “4.1. Basic Operation”. The item selected above is added to past data as well. To disable it, tap the item again.
Repeat Function
This function is helpful for weighing at a regular interval and for using the application as an external indicator while logging. It can be used in step 3 to step 4 in “4.1. Basic Operation”.
- Tap the number (default: 1) shown in Manual/Repeat.
- Select the number of seconds from the list, and then tap OK. The number can be selected in increments of 1 second.
- When Repeat is turned on, the repeat function automatically runs with the command (Ex.: Q) set in Command Data at a designated interval.
- To turn off the repeat function, tap the button next to Repeat.
Changing Commands
-
Tapping a command (Ex: Q) in Command Data enters the edit mode.
-
Enter a command that can be used with a weighing device.
For available commands, refer to the instruction manual of each weighing device. Commands including controlling codes such as(ASCII: 1Bh code) are not usable. -
Either tap Command or enable Repeat to run the command.
Automatic Recover after Disconnection
When connection to a weighing device is disconnected, part of the screen temporarily darkens, and the following operations are disabled. Once it is connected again, the darkened area is brightened, and the operations are automatically recovered.
Troubleshooting
Issue | Where to check | Cause | Action to take |
---|
Connection to a weighing device fails (A device is not selectable in the Scan
screen)| The screen for setting terminals| Bluetooth is turned off.| Turn on
Bluetooth in the terminal.
Pairing is not turned off after previously connecting a weighing device to A&D
WeiV.
Pairing is registered in the terminal settings without using A&D WeiV.
| Restart A&D WeiV after cancelling pairing with the terminal.
The weighing device to be connected is paired with an another terminal.|
Unpair the terminal that has been
connected. Then, connect to A&D WeiV in the terminal to be connected.
A weighing device other than the one to be connected is paired.| Go to the
Scan screen and tap an appropriate weighing device.
Option board| The DIP switches are not set to enable bidirectional
communication (the switches are not turned off).| As described in “2.1. When
Using the Bluetooth Communication Interface Option”, set the DIP switches to
enable bidirectional communication (turn off both
switches).
Settings screen on weighing devices| (With the BA-T series) Bluetooth is not set up correctly.| As described in “2.2.1. Setting Up a
Weighing Device (for the BA-T Series)”, reset the Bluetooth settings.
The Scan screen on A&D WeiV| Bluetooth connection with the weighing device was not ready when A&D WeiV was scanning pairable
devices.
| Swipe down the Scan screen to refresh the screen.
“A&D_BT” is not shown in the list of weighing devices.| The Scan screen on A&D
WeiV| Depending on terminals’ OS versions or manufacturing date of option
boards, only alphanumeric characters may be shown.| Tap what is displayed to
show the main screen. Check if the model name and the serial number shown in
the main screen are same as that of the weighing device to
be connected.
The main screen partly darkens| The main screen on A&D WeiV, weighing devices|
Bluetooth communication with the weighing device is disconnected.| If not
automatically recovered, check if the power of the weighing device is turned
on.
The operation does not proceed according to the designated commands| The main
screen on A&D WeiV, weighing devices| Bluetooth communication with the
weighing device is disconnected.| Tap Command again to send commands. If
the problem persists, check if the power of the weighing device
is turned on.
Weighing devices| The weighing device is not showing a weighing result.| Set
to show weighing result on the weighing device.
The settings of the weighing device are not correct.| Check the function
settings of the weighing device.
Read User Manual Online (PDF format)